Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-Finance HOUSE NO 2 FIRST FLOOR IN FRONT KIRPAL BAGH ASHRAM ISHWAR COLONY NEAR BHAMASHAH MARG DELHI 110009 | NORTH WEST | DELHI | 110009 | L1 | Accepted-Finance YES | |
| 2 | L2₹50.5 L+₹12.5 L (32.8%)Accepted-Finance | L2 | Accepted-Finance YES |
Tender Value
₹41.8 L
EMD Value
₹83,700
Closing Date
29 Jun 2020, 11:00 amClosed
P K Gupta Addl CCE
Chief Construction Engineer (RandD) Central Rao Tula Ram Marg Behind Army HQ Camp Delhi Cantt 110 010
WIDENING OF A1 ITM ROAD MULLINGAR TO CHAR DUKAN (BY REPLACING PARAPET WITH RAILING) AND PROVISION OF LIGHTENING CONDUCTOR IN TECHNICAL AREA AT ITM, MUSSOORIE
2020_DRDO_563577_1
CCE(RandD)C/DIR/RandM/ITM/WKS
Limited
Civil Works
Item Rate
180 days
Mussoorie
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
Chief Construction Engineer (RandD) Central
₹83,700
Yes
5 Aug 2020
8 Jun 2020
30 Jun 2020
9 Jun 2020
29 Jun 2020
10 Jun 2020
Amount
Part I :-
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : (a) In cement mortar
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (a) 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (a) Hard rock (blasting prohibited)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (a) M.S. tube
Applying priming coat: (a) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (a) 600 mm dia RCC pipes
Shifting of Street light pole and handing over to the users. (5 Nos.)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (a) Thermo-Mechanically Treated bars. Fe-500 D confirming to IS :1786
Part II :-
Supply, installation, testing and commissioning ESE (Early Streamer Emission) lightening Conductor of Steel body for Radius protection of 107m in level IV (Model LAP BX175) tested in accordance with NFC 17-102-2011 standard, tested for 115 KA short circuit impulse current, temperature, test of -40 to 120 degree centigrade, advanced triggering time test upto 96 microseconds all as specified by the manufacturers of approved make and all as directed by the Engineer-in-Charge. (Note: The lighting conductor will be fixed on GI Mast or on top of building. The cost of GI mast shall be paid separately)
Supplying and laying of 1x70 Sq .mm. copper flexible cable armoured cable as per direction of Engineer-in-charge.
Supply & installation of 70 Sq .mm. Copper flexible End Termination including all accessories complete as required as per direction of Engineer-in-charge.
Supply and fixing of GI Mast made of GI sheet as per standard design suitable for fixing of lightening conductor of the following height including cost of foundation.
15 Meter
09 Meter
06 Meter
Supply, installation, testing and commissioning of Lightning Strike recorder (6 digits Display) of non-resettable type in an IP 67 enclosure with the minimum sensitivity of 1500 A & maximum capacity of 220 KA (8/20 microsec waveform) tested as per IEC 60-1:189 as per direction of Engineer-in-charge. Model: ERICO, Indelec, Tercel or equivalent
Supply, installation, testing and commissioning of advance maintenance free Chemical Gel Earthing of Copper Tub 3 meter long 50mm dia fill with good conductive compound proper welded with the suitable terminal for connecting of your strip or cable along with a highly conductive, Non-corrosive, Non-magnetic material called EEM-BFC [Ground Resistance Improvement Powder]. The EEM-BFC Compound powder is also put around the electrode in earth pit in the form of slurry with 2bag 25 Kg of earthling backfill compound.
Supply and making Test clamp including all accessories complete as required.
Supply and fixing installation accessories like fasteners U clamps, ring fastener and staywire insulator including all accessories complete as required.
LAVANYA CONSTRUCTION PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .