| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.2 LAccepted-AOC | ₹64.2 L | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹65.5 L+₹1.3 L (2.04%)Rejected-Finance | ₹65.5 L+₹1.3 L (2.04%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹67.5 L+₹3.3 L (5.15%)Rejected-Finance DOOR NO 65 4 426 2 SANTHIGIRI COLONY GAJUWAKA POST GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530026 | ₹67.5 L+₹3.3 L (5.15%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹74.4 L+₹10.2 L (15.8%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | ₹74.4 L+₹10.2 L (15.8%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹77.2 L+₹13.0 L (20.2%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹77.2 L+₹13.0 L (20.2%) | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹81 L
EMD Value
₹1.5 L
Closing Date
24 May 2021, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to Building No P 316 at NAD Visakhapatnam
2021_MES_437044_1
82134 / E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class C Category a i
8 documents required · 8 mandatory
₹1,000
Garrison Engineer Naval Depot
₹1.5 L
Yes
26 Jul 2021
19 Apr 2021
31 May 2021
19 Apr 2021
24 May 2021
10 May 2021
19 Apr 2021 - 26 Apr 2021
Amount
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Taking down Ventilators of any description not exceeding 1.00 Sq.m each complete all as specified and as directed.
Taking down Ventilators of any description exceeding 1.00 Sq.m but not exceeding 2.00 Sq.m each complete all as specified and as directed.
Taking down Shutters of any description exceeding 1.00 Sq.m but not exceeding 2.00 Sq.m each complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 35mm thick, Second Class Hard Wood, Plain framed, Panelled Shutter [Two Panel] with Lock Rail and Panel of 9 mm BWP Commercial Ply or 12 mm Veneered Particle Board with Commercial Veneering on both faces, the size of Rail and Stile as per IS – 1003 [Part – I], Kiln Seasoned and Chemically Pressure treated and fitted to Chowkats complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator frames, Partitions with one or more rebates including jointing cleat for fixing, glazing clips, rubber beading etc complete all as specified and as directed. Note: The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I.
S & F Aluminium Powder Coated [Minimum 50 Micron thick] Sections as in Doors, Window and Ventilator Shutters, Sidehung type, without sash bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Aluminium Powder Coated Snap Beading, Screws, Aluminium Powder Coated Fittings such as Peg Stays 150mm Long [1 No], Hinges, Type B-21 100mm Long [2 Nos], Suitable Handle [1 No] per Shutter complete all as specified and as directed. Note: [a] Supply only panel inserts of Glass / Particleboard / Gauze will be measured and paid separately. [b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless steel Friction Hinges and fixing only of panel inserts of glass / particle board / gauge etc.
Supply only 5mm thick tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 including Powder Coated Aluminium Channel of size 30 X 12 X 1.5mm for fixing Deco Grill complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F 100 mm size, Butt hinges, Extruded Aluminium alloy with galvanised mild steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M & L for PCC 1:3:6, Type C-1, using 20 mm graded stone aggregate as in Bed blocks and Bed plates including weathering, slightly rounded or chamfered angles and throating, necessary form work etc complete all as specified and directed.
S & F Door Closer Hydraulically Regulated, Designation No. 2 universal type, suitable for door shutters of 701 mm to 850 mm in width and of weight between 36 to 60 Kg of aluminium body complete all as specified and as directed.
Dismantling of Structural Steel work including Doors, Gates etc but excluding framed trusses complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings [exclusive of steel sheeting or other covering, running rails and guides] and hanging, also fastening and fixing complete all as specified and as directed.
M & L for Welded steel wire fabric of weight not exceeding 4 Kg per Sq.m fixed to steel or wooden members with suitable fixtures complete all as specified and as directed.
S & F in repairs Steel rolling shutters, thickness of laths of 1.25 mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, Gear operative type with bevel gear box and crank handles complete all as specified and as directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F for pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile or Sinusoidal Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering including dismantling of existing sheets complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Plastic emulsion paint over a coat of alkali resistant primer complete all as specified and as directed.
M & L for preparation of newly plastered wall / Ceiling surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on Wall / Ceiling surfaces complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description including PCC padding of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only Liquid Water Proofing Compound [ISI marked] of approved make.
S & F Seamless Calcium Silicate False Ceiling made out of 12mm thick, 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having Phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer and including Frame Work using GI perimeter channels of 0.55 mm thick, having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, fixed to wall with nylon sleeves and screws at 450 mm intervals, GI intermediate channels of size 45 mm X 15 mm X 0.90 mm supported with GI ceiling angles of size 25 mm X 10 mm X 0.55 mm fixed to soffits with steel expansion fasteners / GI cleats at 1220 mm intervals, ceiling section of 0.55 mm thick having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channel with connecting clips and in direction perpendicular to the intermediate channels at 457 mm centre to centre including Dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 350 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth with out using extra cement and providing 6mm thick joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
M & L for 50mm thick, PCC 1:2:4, Type B-1, using 20mm graded aggregate as in Floors / Hard standing / Path / Plinth protection etc. surface finished even and smooth with out using extra cement complete all as specified and as directed.
M & L for 2mm thick Antistatic flooring mat as per BS: 2050/1078 specifications ocean blue shade using approved quality adhesive and copper grid of size 1.0mx1.0m using fine quality copper strip of size 25x3mm duly connecting the strip to earth of the building for proper electrostatic discharge complete all as specified and as directed by Engineer-in-Charge.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
Taking down or up steel tubing and connections for 25 mm bore of pipe complete all as specified and as directed.
S & F 25 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Taking down or up steel tubing and connections for 20 mm bore of pipe complete all as specified and as directed.
S & F 20 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Taking down or up steel tubing and connections for 15 mm bore of pipe complete all as specified and as directed.
S & F 15 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F in repairs white Vitreous China Squatting Pan "Orissa Pattern" of size 580 mm X 440 mm with integral foot rests and 'P' or 'S' Trap including provision of lime concrete bedding and 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc., grating and union for discharge pipe, CP screws etc. complete all as specified and as directed.
S & F in repairs Stainless Steel, Tubular Towel Rail, D Type, 600 mm long between flanges complete complete all as specified and as directed.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repairs 125mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
S & F in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Floors, Treads of Steps, Window Cills, Cooking Platform etc., and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for 100 mm thick, PCC 1:3;6, Type C-2, using 40 mm graded stone aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for Sand filling as in Sand Bed to Inter Locking Paving Blocks including filling interstices complete all as specified and as directed.
M & L for Inter Locking Paving Blocks of 80mm thick, made with M40 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern, shape and size conforming to IS - 15658 set in floors complete all as specified and directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Taking down Ceiling Fan / Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning, rewinding of Motor using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and replacement of Spares such as Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required complete all as specified and directed. Note- The rate of all spares, rewinding of ceiling fan/ exhaust fan motors and painting shall be deemed to have been included in unit rate quoted.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 71 above but for One 3 pin Socket Outlet 5 Amps on independent Board complete all as specified and as directed.
All as per Serial Item No. 71 above but for One 3 pin Socket Outlet 5 Amps on the Same Board with other switches complete all as specified and as directed.
All as per Serial Item No. 71 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
M & L for Sub main wiring with 5 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 6 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 7 runs of 2.5 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 3 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 4 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 20 mm dia PVC Conduit will be measured as one unit
S & F in repairs Flame proof Switch Socket & Plug combination in LM6 cable termination box in LM6, single pole, 16 Amps, 250 Volts, 2P + Earth complete all as specified and as directed.
S & F in repairs TP & N Enclosure with 3 Pole and Earth Metal Plug & Socket for incorporating TP MCB complete including One MCB, TP, 63 Amps, 415 Volts complete all as specified and as directed.
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating DP MCB complete including One MCB, DP, 32 Amps, 240 Volts complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, IP-42 rated, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. Note: The Contractor shall make good the disturbed surfaces to match with existing & the rate of the same shall be deemed to have been included in unit rate quoted.
S & F in repairs MCB DB, TPN, 4 Way, 240 Volts, with DIN Channel, IP-42 rated, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. Note: The Contractor shall make good the disturbed surfaces to match with existing & the rate of the same shall be deemed to have been included in unit rate quoted.
S & F in repairs MCCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCCBs and including one MCCB, FP, 125 Amps, 16 KA, 415 Volts, 50 Hz complete all as specified and as directed. Note: The Contractor shall make good the disturbed surfaces to match with existing & the rate of the same shall be deemed to have been included in unit rate quoted.
S & F MCB, SPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB, TPN, 125 Amps, 35 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCB, TP, 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F Energy efficient Sleek LED Mirror Light Fitting of not less than 1000 Lumens, Surface / Recess mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 2' X 2' Grid False Ceiling of not less than 5000 Lumens output, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Taking down Light Fittings of any description, any type and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including cleaning and minor repairs complete all as specified and as directed.
S & F Energy efficient & Long life Building Security Light Luminaire, of not less than 4500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Supply, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
Supply, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. including taking down old LT Cables of any description complete all as specified and as directed.
S & F in repair Earth continuity Conductor or main earthing lead made of Copper Strip of size 20 X 3mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Earth continuity conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repair Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable etc complete all as specified and as directed.
S & F in repair of Junction Box 20mm dia (1 to 4 way) complete all as specified and as directed.
Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified and as directed.
S & F in repairs Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs GI pipe, 40mm dia, Medium grade for earthing lead protection etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
S & F in repairs DLP PVC adaptable Trunking System complete of size 105 X 50 mm including base, covers, partitions, trunking, body joint cover, all finishing accessories and mounting wiring accessories, end caps, T Bend, Flat Angle, Internal and External Bends complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 20 X 3mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Hard / Dense soil for laying Cables etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supply and lay Bricks, common burnt clay building bricks, sub–class "B", Designation 75 in trenches for cable protection complete all as specified and as directed.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
ARCHANA ENGINEERING ENTERPRISES
K K INFRA
Mavee Syndicate
GS ENGINEERS
ALLURI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .