Executive Engineer(E)
CTO Bldg ERnakulam
NIT for AC CLS North Parur
2021_BSNL_89908_1
18/ED/EKM/2021-22
Open Tender
Electrical Works
Item Rate
60 days
CTO Bldg Ernakulam
Please refer Tender documents.
2 documents required · 2 mandatory
₹1
BSNL
Yes
20 Oct 2021
29 Sept 2021
18 Oct 2021
29 Sept 2021
13 Oct 2021
29 Sept 2021
29 Sept 2021 - 13 Oct 2021
90 days
Amount
I Supply and ITC of AC units
Supplying of Ductable type Split AC Units having 3.0TR cooling capacity (9000 Kcal/hr), operating on 230V/415V, 50 Hz, A.C.supply, and nominal air flow not less than 1900 Cub. mtr/hr, with temperature control thermistor, remote control unit, filters, rotary / scroll/ reciprocating type compressor complete as per specifications, terms and conditions attached as required.The units shall have at least 24 months manufacturer's / Supplier's warranty (Panasonic / Universal comfort (Voltas) /Hitachi / LG / Carrier / Daikin / Mitsubishi /Samsung/ O-General/Videocon/ Blue star)
Supplying of 1.5 TR inverter type split AC unit 5 star as per BEE star operating on 230 V, 50 Hz single phase supply rating having nominal cooling capacity of 4500 Kcal/hr , minimum air flow volume (Wet CFM-High) of 450 and minimum Indian Seasonal Energy Efficient Ratio (ISEER) of 4.5 with temperature control thermistor, remote control unit, filters, rotary / scroll type compressor along with the copper pipe, suitable size of PVC insulated cord wire and PVC drain pipe including transportation, etc. complete as per specifications, terms and conditions attached as required. The units shall have atleast 24 months manufacturer's / Supplier's warranty ((Panasonic / Universal comfort (Voltas) /Hitachi / LG / Carrier / Daikin / Mitsubishi /Samsung/ O-General/Videocon/ Blue star))
II-ITC OF AC UNITS
Installation, Testing and commissioning of 3 TR ductable AC unit along with the copper piping, PVC drain pipe , wiring , thermal insulation and making opening on wall and making good the damages etc.,including mounting of indoor unit and outdoor units on existing angle iron frame work, pressure testing, vacuumising, topping up of additional gas in the refrigerant system, installation of all hardware items, etc as required.
Installation, Testing and commissioning of 1.5 TR split AC unit along with the copper piping, PVC drain pipe and wiring up to the standard length thermal insulation and making opening on wall and making good the damages etc.,including mounting of indoor unit with suitable arrangements and outdoor units on existing angle iron frame work, pressure testing, vacuumising, topping up of additional gas in the refrigerant system, installation of all hardware items, as required.
Steel work welded in built up sections/ framed work including cutting, welding, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel members of suitable dimensions etc. for fixing the AC units as required.
Supplying and fixing the following additional items suitable for the Ductable split type AC units (under Item.No.1), wherever required .
Suitable size of copper suction line, copper liquid line, along with thermal insulation tube made from Elastomeric foam based on synthetic rubber (nitrile butadiene rubber) for copper pipe, as required.
PVC insulated 3 core 4 sq mm /5 core 2.5 sq.mm ISI marked copper cord wire along with the refrigerant line/ on the surface as required
Supplying and fixing the following additional items suitable for the 1.5 TR ST AC units (under Item.No.2), over and above standard length supplied with the unit wherever required .
Suitable size of Copper pipes (hot gas and liquid line) including thermal insulation tube made from Elastomeric foam based on synthetic rubber (nitrile butadiene rubber) etc., as required.
Suitable size of PVC insulated 4 core 2.5 sq.mm ISI marked copper cord wire etc as reqd.
P/F 25mm dia PVC heavy guage pipe for draining condensate water from evaporator unit including fixing on surface/recess with necessary accessories like bends, couplers, Tees, etc., as required.
S/F of 63 mm dia rigid PVC Pipe 4 kg/cm2 with ISI marked pvc pipe with accessories for the protection of refrigerent pipe and cables etc i/c clamping on wall , testing, commissioning etc as reqd.
III Price schedule for AMC(Rate is for whole number of units).
Comprehensive Maintenance of 4 Nos 3 TR Ductable split ac unit etc as required. (As per specifications attached )
First Year (Under warranty)
Second Year (Under warranty)
Third Year
Fourth Year
Fifth Year
Comprehensive Maintenance of17 Nos 1.5 TR split ac unit etc as required. (As per specifications attached )
First Year (Under warranty)
Second Year (Under warranty)
Third Year
Fourth Year
Fifth Year
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .