Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹43.7 L+₹3.7 L (9.34%)Rejected-Finance | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹45.0 L+₹5.0 L (12.5%)Rejected-Finance | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹45.1 L+₹5.1 L (12.8%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹45.2 L+₹5.2 L (13.0%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L5 | Rejected-Finance Rejected due to not being L1 |
| Sl No | Description | Qty | Unit | nexa L1 | N.O. Antony Contractors L3 | Oriental Constructions L10 | Linsta Services L7 | Aarjay Tech Engineering L8 | Classic Builders L11 | ZOOM ENTERPRISES L6 | WELTRONENGINEERINGSERVICES L4 | K A ANTONY & SONS L2 | ELAN ENGINEERS L5 | HEAVEN ENGINEERS AND CONTRACTORS L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending complaint including transportion of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration,checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at 'E' area at Naval Base during off hours (1700 hrs evening to 0900 Hrs morning ) on all working days all as specified and directed.
NOTE:-
(i) The contractor should display contact number at complaint cell to register users complaint.
(ii) The recovery of rupees 500 per complaint will be charged if contractor failed to attend that instipulated time period .
(iii) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly including in all aspects like labours, tool, transportation etc. | 300 | Per complaint | 110 ₹33,000 | 12 ₹3,600 | 12 ₹3,600 | 15 ₹4,500 | 30 ₹9,000 | 39 ₹11,700 | 9 ₹2,700 | 14 ₹4,200 | 36 ₹10,800 | 12 ₹3,600 | 8 ₹2,400 Lowest |
| 2.00 | Taking down copper/ aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light removing materials to store for keeping in safe custdoy for taking credit to match with existing suface all as specified and directed. | 360 | Per Point | 15 ₹5,400 Lowest | 30 ₹10,800 | 36 ₹12,960 | 50 ₹18,000 | 50 ₹18,000 | 39 ₹14,040 | 25 ₹9,000 | 38 ₹13,680 | 36 ₹12,960 | 40 ₹14,400 | 35 ₹12,600 |
| 3.00 | M&L for point wiring for one light with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit 20 mm dia medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed. | 200 | Per Point | 90 ₹18,000 Lowest | 320 ₹64,000 | 360 ₹72,000 | 350 ₹70,000 | 450 ₹90,000 | 359 ₹71,800 | 290 ₹58,000 | 324 ₹64,800 | 340 ₹68,000 | 330 ₹66,000 | 380 ₹76,000 |
| 4.00 | All as per item No. 3 here-in-before but for one fan point controlled by one push button on independent board complete all as specified and as directed. | 30 | Per Point | 100 ₹3,000 Lowest | 350 ₹10,500 | 380 ₹11,400 | 360 ₹10,800 | 400 ₹12,000 | 359 ₹10,770 | 330 ₹9,900 | 335 ₹10,050 | 340 ₹10,200 | 350 ₹10,500 | 360 ₹10,800 |
| 5.00 | All as per item No. 3 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed complete all as specified and as directed. | 10 | Per Point | 100 ₹1,000 Lowest | 360 ₹3,600 | 390 ₹3,900 | 370 ₹3,700 | 350 ₹3,500 | 359 ₹3,590 | 340 ₹3,400 | 345 ₹3,450 | 340 ₹3,400 | 360 ₹3,600 | 350 ₹3,500 |
| 6.00 | All as per item No. 3 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed. | 50 | Per Point | 100 ₹5,000 Lowest | 360 ₹18,000 | 370 ₹18,500 | 330 ₹16,500 | 320 ₹16,000 | 359 ₹17,950 | 340 ₹17,000 | 355 ₹17,750 | 340 ₹17,000 | 340 ₹17,000 | 370 ₹18,500 |
| 7.00 | All as per item No. 3 here in before but for one 5 pin 5 Amp socket outlet point on the same board complete all as specified and directed. | 20 | Per Point | 100 ₹2,000 | 90 ₹1,800 Lowest | 110 ₹2,200 | 100 ₹2,000 | 120 ₹2,400 | 209 ₹4,180 | 100 ₹2,000 | 98 ₹1,960 | 200 ₹4,000 | 110 ₹2,200 | 100 ₹2,000 |
| 8.00 | All as per item No. 3 here in before but using with 2.5 Sqmm copper conductor multistranded (FRLSH) PVC insulated, unsheathed cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheated cable as earth continity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed. | 50 | Per Point | 100 ₹5,000 Lowest | 410 ₹20,500 | 420 ₹21,000 | 400 ₹20,000 | 380 ₹19,000 | 439 ₹21,950 | 390 ₹19,500 | 412 ₹20,600 | 450 ₹22,500 | 420 ₹21,000 | 430 ₹21,500 |
| 9.00 | S&F in replacement Modular Bell push 6A, 1module, complete all as specified and directed. | 25 | Each | 30 ₹750 Lowest | 45 ₹1,125 | 45 ₹1,125 | 40 ₹1,000 | 50 ₹1,250 | 59 ₹1,475 | 40 ₹1,000 | 44 ₹1,100 | 50 ₹1,250 | 50 ₹1,250 | 40 ₹1,000 |
| 10.00 | S&F in replacement modular Fan Regulator, two module, electronic rotary, stepped type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed. | 50 | Each | 110 ₹5,500 Lowest | 290 ₹14,500 | 300 ₹15,000 | 280 ₹14,000 | 250 ₹12,500 | 289 ₹14,450 | 310 ₹15,500 | 291 ₹14,550 | 300 ₹15,000 | 300 ₹15,000 | 300 ₹15,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
11 Aug 2025, 6:00 pmClosed
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2025_MES_721471_1
8519_GENW
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹90,000
6 Nov 2025
19 Jul 2025
14 Aug 2025
19 Jul 2025
11 Aug 2025
4 Aug 2025
19 Jul 2025 - 4 Aug 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .