Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC | ₹1.5 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹1.7 Cr+₹20.5 L (13.4%)Rejected-AOC | ₹1.7 Cr+₹20.5 L (13.4%) | 2 | Rejected-AOC L2 |
Tender Value
₹1.6 Cr
EMD Value
₹50,000
Closing Date
11 Jan 2024, 3:00 pmClosed
SUPERINTENDING ENGINEER
PH CIRCLE, KWA, MALAPPURAM
Jal Jeevan Mission (JJM)-CWSS to Ponnani and adjoining Panchayaths Phase 2 -Eletrification of SCADA system and Pumpsets in WTP at Nariparamba - Package 7A
2024_KWA_639898_1
SE/PHC/MPM/RE266/2023-24
Open Tender
Civil Works - Water Works
Item Rate
120 days
Nariparamba
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,520
₹50,000
16 May 2024
4 Jan 2024
12 Jan 2024
4 Jan 2024
11 Jan 2024
4 Jan 2024
Amount
Electrification of Pumpsets
OD100254/2023-2024:3.3KV VCB PANEL- Supply Erection and commissioning of 3.3KV, 630A,250 MVA Vacuum Circuit Breaker Cubical type dust and Vermin proof free standing floor mounting panel board as per technical specifications consisting of the following complete with all interconnection, painting and control wiring etc., as per Electrical inspectorate`s standard and specifications. INCOMMER –3.3KV, 630A,250 MVA Vacuum Circuit Breaker 1NOS OUT GOING –3.3KV, 630A,250 MVA Vacuum Circuit Breaker 5NOS
OD100253/2023-2024:3.3KV VCB PANEL COUPLING EXISTING 3.3KV MULTI PANEL- Supply Erection and commissioning of 3.3KV, 630A,250 MVA Vacuum Circuit Backer Cubical type dust and Vermin proof free standing floor mounting panel board as per technical specifications consisting of the following complete with all interconnection, painting and control wiring etc., as per Electrical inspectorate`s standard and specifications. Additional 3.3KV, 630A,250 MVA Vacuum Circuit Backer 1NOS out going for new panel power supply
OD100252/2023-2024:3.3 KV , 150 KVAR HT APFC PANEL - supply erection and commissioning of 150 KVAR HT APFC Cubical type dust and Vermin proof free standing floor mounting panel board as per technical specifications consisting of the following complete with all interconnection, and control wiring etc., as per Electrical inspectorate`s standard and specifications. for power factor between 0.95-1 - INCOMMER –3.3KV, 630A,ISOLATOR 1NO CAPACITOR – 75 Kvar 2 NOS & REACTOR 2SET
OD100251/2023-2024:3.3 KV FCMA STARTER - (for 3.3kv motor ) supply Erection and commissioning of 3.3 KV FCMA STARTER Cubical type dust and Vermin proof free standing floor mounting panel board as per technical specifications consisting of the following complete with all interconnection, and control wiring etc., as per Electrical inspectorate`s standard and specifications 3.3 KV FCMA STARTER suitable for newly supplied HT Motor (110 to 135 KW)
OD100250/2023-2024:HV CABLE LAYING- Supply and Laying of power cable of best conductivity Al, conforming to relevant BIS , in ground level including clamping in the existing cable duct. 3C X240 sq.mm 11KV XLP
OD100257/2023-2024:HV CABLE LAYING- Supply and Laying of power cable of best conductivity Al, conforming to relevant BIS , in ground level including clamping in the existing cable duct. 3C X 120 sq.mm 11KV XLP
OD100249/2023-2024:HC Cable termination:: Supply and Fixing of heat shrinkable type 11KV Indoor cable termination for 3C X 240 Sqmm XLPE cables
OD100267/2023-2024: Supply and Fixing of heat shrinkable type 11KV Indoor cable termination for 3C X 120 Sqmm XLPE cables
OD100266/2023-2024:EARTH GIRDS - Laying/fixing of earthling conductor of copper strips/wires including necessary earthling, trenches, jointing as per IS 3043/87 in trenches walls, pulling through pipes etc. Copper Flat 25x 3mm
OD100265/2023-2024:CABLING - Laying the following sizes of PVC/ APVC AL cables for working voltage up to 11000V through trench/pipes/cable tray/clamped on wall wherever necessary with all protections as per is specifications 2CoreX2.5 Sqmm copper cable
OD100264/2023-2024:CABLING - Laying the following sizes of PVC/ APVC AL cables for working voltage up to 11000V through trench/pipes/cable tray/clamped on wall wherever necessary with all protections as per is specifications 6CoreX2.5 Sqmm copper cable
OD100263/2023-2024:TERMINATION - Terminating the following sizes of PVC, APVC AL cable working voltage up to 1100V using cable gland and socket including gland earthling 2CoreX2.5 Sqmm copper cable
OD100262/2023-2024:TERMINATION - Terminating the following sizes of PVC, APVC AL cable working voltage up to 1100V using cable gland and socket including gland earthling 6CoreX2.5 Sqmm copper cable
OD100261/2023-2024:Drawing and Documentation- Preparation of all drawings, submitting and getting approval from Electrical inspectorate submitting of completion certificates and arranging inspection ,inspectorate Etc. and commissioning of the whole installation in the premises All statutory payments reimbursed on production of the owner
Electrification of SCADA System
OD100533/2023-2024:CABLING- Supply Laying the following sizes of XLPE UG AL cables for working voltage up to 1100V through trench /pipes /cable tray/clamped on wall wherever necessary with all protections as per is specifications 3x10 Sq mm
OD100532/2023-2024:TERMINATION- Supply Terminating the following sizes of XLPE UG AL cable working voltage up to 1100V using cable gland and socket including gland earthling 3x10 Sq mm
OD100531/2023-2024:V DB (vcdb for valve control supply) Supply Installation of VDB MCB /4way/DB with 1No /40A 4pole 100mA / 300mA RCCB as incoming and following SP MCB as outgoings complete. 6 AMPS - 3p 4 No
OD100530/2023-2024:V DB (vcdb for valve control supply) Supply Installation of VDB MCB /12way/DB with 1No 63 A/40A 4pole 100mA /300mA RCCB as incoming and following SP MCB as outgoings complete. 6 AMPS -1p 6 No 6 AMPS - 3p 10 No
OD100539/2023-2024:Cable tray- Supply and fixing 1.6 mm GI perforated cable try for cable laying, vertical and horizontal position sporting 100mm x 50 mm welding with painting
OD100538/2023-2024:Cable tray- Supply and fixing 1.6 mm GI perforated cable try for cable laying, vertical and horizontal position sporting welding with painting 150mmx50mm
OD100537/2023-2024:Cable tray- Supply and fixing 1.6 mm GI perforated cable try for cable laying, vertical and horizontal position sporting welding with painting 200mmx50mm
OD100536/2023-2024:Cable tray- Supply and fixing 1.6 mm GI perforated cable try for cable laying, vertical and horizontal position sporting welding with painting 300mmx50mm
OD100552/2023-2024:Scada (1.0 x3core normal cable) Carrying out wiring from Scada control board to control valve board using 3core 1runs of 0.5 sq.mm copper wire PVC insulated copper wire through pvc conduit along with all accessories ( for Scada) Shielded type
OD100551/2023-2024:Scada (1.0 x8core normal cable) Carrying out wiring from Scada control board to control valve board using 8core 1runs of 0.5 sq.mm copper wire PVC insulated copper wire along with all accessories ( for Scada)Shielded type
OD100550/2023-2024:Scada (0.5 x18core normal cable) Carrying out wiring from Scada control board to control valve board using 18core 1runs of 0.5 sq.mm copper wire PVC insulated copper wire through pvc conduit along with all accessories ( for Scada)Shielded type
OD100549/2023-2024:Scada (0.5 x3/core signal cable) Carrying out wiring from Scada control board to controlvalve board using 3core 1runs of 0.5 sq.mm copper wire PVC insulated copper wire along through pvc conduit with all accessories ( for Scada) Shielded type
OD100548/2023-2024:Scada (0.5 x8core signal cable) Carrying out wiring from Scada control board to control valve board using 8core 1runs of 0.5 sq.mm copper wire PVC insulated copper wire through pvc conduit along with all accessories ( for Scada)Shielded type
OD100547/2023-2024:Scada (1.0 x18core signal cable) Carrying out wiring from Scada control board to control valve board using 10core 1runs of 0.5 sq.mm copper wire PVC insulated copper wire through pvc conduit along with all accessories ( for Scada) Shielded type
OD100546/2023-2024:Scada (2.5 x4core valve supply cable) Supply and Laying connecting and wiring from VCDB control board to control valve using 3core 1runs of 2.5 sq.mm copper wire PVC insulated through pvc conduit along with all accessories (for Scada)
OD100545/2023-2024:Transformer Oil filtaration machine transportation
OD100544/2023-2024:Transformer Oil filtaration
OD100543/2023-2024:1250 kVA 11kV / 3.3kV Transformer OLTC Overhauling including gasket replacement
OD100542/2023-2024:Silica Gel replacement for transformer breather
OD100650/2023-2024:Transformer oil supply
OD100649/2023-2024:750 kVA 11kV / 0.433kV Transformer OLTC Overhauling including gasket replacement
OD100648/2023-2024:Relay Testing - Low set earth fault relay
OD100647/2023-2024:Relay Testing - Restricted earth fault relay
OD100646/2023-2024:Relay Testing - Over Voltage relay
OD100645/2023-2024:Relay Testing - Motor protection relay
OD100644/2023-2024:8 CORE 0.5 SQMM SIGNAL CABLE
OD100643/2023-2024:3 CORE 0.5 SQMM SIGNAL CABLE
OD100642/2023-2024:3 CORE 1 SQMM NORMAL CABLE
OD100641/2023-2024:8 CORE 1 SQMM NORMAL CABLE
OD100640/2023-2024:18 CORE 0.5 SQMM SIGNAL CABLE
OD100639/2023-2024:18 CORE 1 SQMM NORMAL CABLE
SULAIMAN KAVUNGAL
Bidder Name
SULAIMAN KAVUNGAL
MIDLAND ENGINEERING AND CONTRACTING COMPANY
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .