Loading…
Loading…
Tender Value
Refer Docs
Closing Date
22 Jun 2026, 5:30 amDue tomorrow
Similar tender results from the same govt authority in the past 3 years.
NHIT Southern Projects Private Limited
Unit 325, 3rd Floor, D21 Corporate Park, Sector 21, Dwarka, Dhulsiras, New Delhi-110077
Request for Proposal (“RFP”) issued by NHIT Southern Projects Private Limited (NSPPL) for the engagement of an agency/firm to undertake the renovation of toll plazas at the Bareilly–Sitapur project of NSPPL.
NSPPL/FY26-27/RFP/ Toll Plaza Renovation-BSRP
NSPPL/FY26-27/RFP/ Toll Plaza Renovation-BSRP
RFP
Bareilly, Uttar Pradesh
8 Jun 2026
8 Jun 2026
22 Jun 2026
This item includes the supply, fabrication, and installation of Heavy duty aluminum (100mmx 50mmx 3mm) Partion Wall comprising frames and shutters, as per the approved architectural and engineering drawings. Aluminum sections shall conform to IS 733 and IS 1285, made from grade 6063 T5, and black powder-coated to a minimum thickness of 50 microns. EPDM rubber/neoprene gaskets and silicon sealants, as per IS 15477, shall be used for sealing and water resistance at all junctions. 6mm thick float glass panelling shall be used for panneling work. The make for aluminum sections shall be or equivalent to Jindal or Hindalco standard sections. In case the material is procured from a manufacturer other than Jindal or Hindalco, approval shall be sought from the Engineer-in-Charge, and any material benefit should be passed on to the client. Frames and shutters shall be fixed using dash fasteners and stainless steel screws. Accessories like cleat angles, aluminum beading, heavy-duty 5" hinges (3 numbers), tower bolts, door locks, door handles, glass Panel are included in the rate. All work complete in all respect. Fabrication shall begin only after approval of shop drawings by the Engineer-in-Charge. Measurement and Payment will be based on Sqm Basis
Repairing, Replacement of Existing aluminum doors, windows, and ventilators aluminum section. Replacement of aluminum section shall be matched with existing existing aluminum section. The work shall be including of removal of exsting damed alumunim section, fixing of new aluminum section, replacement of existing EPDM rubber, replacement of damaged cleat angles, aluminum beading, hinges, tower bolts, window locks, handles if any required shall be including in the rate. Payment will be based on the sqm, sqm shall be calcuated in opening portion of Doors and windows.
This item includes the supply, fabrication, and installation of Heavy duty aluminum (100mmx 50mmx 3mm) aluminum doors, windows, and ventilators, comprising frames and shutters, as per the approved architectural and engineering drawings. Aluminum sections shall conform to IS 733 and IS 1285, made from grade 6063 T5, and black powder-coated to a minimum thickness of 50 microns. EPDM rubber/neoprene gaskets and silicon sealants, as per IS 15477, shall be used for sealing and water resistance at all junctions. 6mm thick float glass panelling shall be used for panneling work. The make for aluminum sections shall be or equivalent to Jindal or Hindalco standard sections. In case the material is procured from a manufacturer other than Jindal or Hindalco, approval shall be sought from the Engineer-in-Charge, and any material benefit should be passed on to the client. Frames and shutters shall be fixed using dash fasteners and stainless steel screws. Accessories like cleat angles, aluminum beading, heavy-duty 5" hinges (3 numbers), tower bolts, door locks, door handles, glass Panel are included in the rate.This item also covers the replacement of damaged aluminum doors, windows, and ventilators, with no extra payment for dismantling or stacking materials within the premises. All work complete in all respect. Fabrication shall begin only after approval of shop drawings by the Engineer-in-Charge. Measurement and Payment will be based on Sqm Basis
Supply and fixing the granite stone of approved shade for jambs/cills of doors & windows of the builing(location specified herein below),complete in all respects with finishing work, as per the direction of the engineer in charge. Specifications: - Material: 18mm thick granite stone - Width: 1 foot (approximately 305 mm) Locations: - All doors: head and jamb (3 sides) - All windows: Cill, jamb, and head (4 sides) Inclusions: - Supply of granite stone in approved shade. - Cutting and shaping of stone to fit the specified locations. - Fixing of stone at the specified locations. - Completing all necessary finishing work. -2mm Chamfering of open edges.
Providing and fixing of Automatic door closer with approved good quality of brand etc., (Brand : Godrej)
All charges for providing and fixing of vertical executive curtains with scope including manpower , machinaries , tools & tackles , transportations etc.,
Toll Booths:
Replacement of Existing ACP with 4mm ACP sheet at Toll Booth. The work including of supply and fixing of new ACP sheet, Removal of existing ACP sheet, all work complete
Replacement of 6mm Toughened Glass and Repair of Aluminium Frame for Toll Plaza Booth Window This item covers the replacement of a 10mm thick toughened glass pane and the repair of the aluminium frame for a toll plaza booth window. The glass shall be of IS 2553 (Part 2) compliant quality, assumed to be 1.5m x 1.5m in size, fixed using silicone sealant and appropriate fasteners. The damaged aluminium section will be replaced with Grade 6063 or equivalent aluminium as per IS 733, with welding, grinding, and finishing of the frame to ensure strength and stability. The work includes necessary labor, scaffolding, and the cleaning of the glass after installation. Transport and handling costs for materials and access equipment are included, assuming typical site conditions and access for the work. Payment will be based on the sqm basis of windows replaced. Any variation in glass size or frame profile will be addressed through mutual agreement. This item excludes additional work such as replacement of other frames or glass beyond the specified scope. All work will conform to IS 2553 and IS 733, and the installation will follow standard practices for toll booth windows in India. The unit of measurement is Sqm with all materials, labor, and transportation included.
PAINTING WORKS:
Providing and Applying Primer, Putty, and Emulsion Paint to Interior Surfaces (Building) This item covers the preparation and application of 1 coat of putty (1mm thickness), 1 coat of primer, and 2 coats of Apcolite Premium Emulsion or an equivalent emulsion paint in the approved shade ( off-white with blue bands) to the interior surfaces of the building. The work includes thorough cleaning of the surface to remove dirt, dust, oil, grease, efflorescence, and any other contaminants. After cleaning, the surface will be treated with 1mm thick putty to smoothen the surface, followed by the application of a coat of primer and two coats of emulsion paint. The work will be completed as per MoRTH Clause 800, CPWD Specifications 500, and the directions of the Engineer-in-Charge. The final price includes the cost of all materials (primer, putty, emulsion paint), labor for surface preparation, cleaning, application of putty, primer, and paint, transportation of materials to the site, overheads, profit, and any required machinery for application. Relevant Standards: MoRTH Clause 800: Painting and Surface Finishing Work CPWD Specification 500: Finish for Internal Walls, including Use of Putty and Emulsion Paint IS 15489: Code of Practice for Painting of Concrete Surfaces IS 5410: Specification for Weather-Resistant Paints for Exterior Use (for the use of emulsion)
Providing and Applying Primer and Weatherproof Paint to Exterior Surfaces (Building) This item includes the preparation and application of 1 coat of primer and 2 coats of weatherproof paint in the approved shade((off-white with blue bands)) to the exterior surfaces of the building. The work involves thoroughly cleaning the surface to remove all dirt, dust, oil, grease, efflorescence, and other contaminants that could affect paint adhesion. After cleaning, a coat of primer is applied, followed by two coats of weatherproof paint, ensuring a durable and uniform finish. The work will be carried out in accordance with MoRTH Clause 800, CPWD specifications, and the directions of the Engineer-in-Charge. The final price includes the cost of all materials (primer, weatherproof paint), labor for surface preparation, cleaning, application of primer and paint, transportation of materials to the site, overheads, profit, and any required machinery for application. Relevant Standards: MoRTH Clause 800: Painting and Surface Finishing Work CPWD Specification 305: Surface Preparation and Painting Work for Exterior Surfaces IS 5410: Specification for Weather-Resistant Paints for Exterior Use
Providing and applying two coats enamel paint (First Quality of Asian/Berger/Nerolac) This item includes the preparation and application of 2 coats of synthetic enamel paint in the approved shade to the Kerb surfaces. The work involves thoroughly cleaning the surface to remove all dirt, dust, oil, grease, efflorescence, Soil and other contaminants that could affect paint adhesion. After cleaning two coats of synthetic enamel paint, ensuring a durable and uniform finish. The work will be carried out in accordance with MoRTH Clause 803, and the directions of the Engineer-in-Charge. The final price includes the cost of all materials, labour for surface preparation, cleaning, application of paint, transportation of materials to the site, overheads, profit, Safety during the work and any required machinery for application. Relevant Standards: MoRTH Clause 803: Painting and Surface Finishing Work
Application of Synthetic Enamel Paint over Steel Structure (Old Surface) This item includes the removal of old paint, surface preparation, and the application of one coat of red oxide primer and two coats of synthetic enamel oil paint on steel surfaces like sheets, trusses, and supporting posts. The old paint shall be removed using manual means or mechanical methods such as wire brushing, scraping, or buffing, as per IS 1477 (Part 1). The surface shall be cleaned of rust, loose paint, and contaminants. Material Specifications Primer: Red oxide primer of approved make (e.g., Asian or equivalent), applied at a thickness of 25-30 microns. Paint: Two coats of synthetic enamel oil paint (e.g., Asian or equivalent), applied at a thickness of 35-40 microns per coat, in the approved shade. Compliance and Quality Control Work must comply with IS 1477 (Part 1) for surface preparation and IS 2395 for paint application. The finish must be free of defects and verified by the Engineer-in-Charge. Measurement and Payment Measurement shall be based on the area of steel surfaces to be painted. The rate includes all labor, materials, and surface preparation. No separate payment will be made for paint removal.
Application of Synthetic Enamel Paint over 100 mm dia MS Pipe safety Pipe for Booth This item includes the removal of old paint, surface preparation, and the application of one coat of red oxide primer and two coats of synthetic enamel oil paint on steel surfaces like sheets, trusses, and supporting posts. The old paint shall be removed using manual means or mechanical methods such as wire brushing, scraping, or buffing, as per IS 1477 (Part 1). The surface shall be cleaned of rust, loose paint, and contaminants. Material Specifications Primer: Red oxide primer of approved make (e.g., Asian or equivalent), applied at a thickness of 25-30 microns. Paint: Two coats of synthetic enamel oil paint (e.g., Asian or equivalent), applied at a thickness of 35-40 microns per coat, in the approved shade. Compliance and Quality Control Work must comply with IS 1477 (Part 1) for surface preparation and IS 2395 for paint application. The finish must be free of defects and verified by the Engineer-in-Charge. Measurement and Payment Measurement shall be based on the RMT of steel Pipe to be painted. The rate includes all labor, materials, and surface preparation. No separate payment will be made for paint removal.
MS Round pipe railing 50mm dia MS Pipe re-painting with scope including 2 coats of enamel paints: Post height 1.3m This item includes the removal of old paint, surface preparation, and the application of one coat of red oxide primer and two coats of synthetic enamel oil paint on steel surfaces like sheets, trusses, and supporting posts. The old paint shall be removed using manual means or mechanical methods such as wire brushing, scraping, or buffing, as per IS 1477 (Part 1). The surface shall be cleaned of rust, loose paint, and contaminants. Material Specifications Primer: Red oxide primer of approved make (e.g., Asian or equivalent), applied at a thickness of 25-30 microns. Paint: Two coats of synthetic enamel oil paint (e.g., Asian or equivalent), applied at a thickness of 35-40 microns per coat, in the approved shade. Compliance and Quality Control Work must comply with IS 1477 (Part 1) for surface preparation and IS 2395 for paint application. The finish must be free of defects and verified by the Engineer-in-Charge. Measurement and Payment Measurement shall be based on the RMT of steel Pipe to be painted. The rate includes all labor, materials, and surface preparation. No separate payment will be made for paint removal.
MISCELLANEOUS WORKS:
1st Class Brick Masonry Work in Cement Mortar 1:3 This item includes the construction of brick masonry using 1st class burnt clay bricks, laid in cement mortar of mix ratio 1:3 (Cement: Sand), for foundations, walls, piers, columns, and other structures as per the approved drawings and technical specifications, from ground level till plinth and in superstructure above plinth level up to floor five level. The work includes thoroughly soaking the bricks in water for a minimum period of one hour prior to laying them to ensure proper bonding and to achieve maximum strength. The work shall also involve the protection of the green structure from rain during curing by suitable coverings. Curing of the masonry shall be done for a minimum period of 7 days as per standard practices to ensure the proper hydration and strength development of the mortar and masonry. The work excludes the cost of pointing, plastering, or any additional finish unless specified otherwise. The work shall be executed in accordance with the relevant CPWD and IS specifications. The final price includes the cost of procurement of 1st class bricks, cement, sand, and other necessary materials, including royalty charges, transportation to site, soaking of bricks, labor, machinery, curing, and all overheads and profit. The cost does not include pointing, plastering, or any decorative finishes unless specified separately. Safety measures and quality checks shall be implemented during all stages. Relevant Standards: CPWD Specification No. 6.4 (Brick Masonry Work) MoRTH Clause 1300 (Brick Masonry Work)
Plaster (20 mm Thick in Two Layers with Waterproofing Compound) The work includes 20 mm thick external plaster in two layers as per CPWD Clause 13. cement mortar 1:3 (1 cement: 3 fine sand) applied. The work includes raking joints, cleaning, surface preparation, uniform application of both layers, curing as specified, and ensuring a smooth finish. The cost includes all materials (cement, sand, waterproofing compound, water), labor, curing, scaffolding, and quality checks. Measurement shall be in Sqm of finished plastered area. The work shall conform to IS 1661:1980 and CPWD specifications. Rate is applicable from plinth level to floor five level.
Providing and laying integral cement‑based waterproofing treatment with brick‑bat coba over RCC slab and parapet walls up to 300 mm heights, as per CPWD Spec 22.7: including surface cleaning , scrapping, cleaned neatly of all morter dropping, loose material with brooms/cloth,first slurry coat (2.75 kg/m²), laying 25–115 mm brick‑bats with 1:5 mortar bed and waterproofing compound, second slurry coat after 2 days, finishing layer of 20 mm cement mortar (1:4) with fibreglass cloth membrane and 300×300 mm surface pattern, complete curing and testing (ponding for 14 days). Rate to include all materials, waterproofing compound, fibreglass, labour, curing, testing, and no deductions for openings up to 0.40 m².
Plain Cement Concrete M-15 Grade in Open Foundation All charges for supply & placing of Plain Cement Concrete (M-15 grade) in open foundations as per approved drawings and technical specifications, conforming to MoRTH Sections 1500, 1700, and 2200. The mix shall use aggregates of size not exceeding 20 mm, with a workable slump suitable for PCC. The thickness of PCC shall be as specified in drawing. Concrete placement shall ensure a free-fall height of less than 1.5 m to prevent segregation, compacted using mechanical vibrators to achieve proper consolidation. The work includes the preparation of the foundation surface, leveling, placing concrete, and finishing exposed surfaces to achieve the required levels and smoothness. Adequate curing, as per approved methods, shall be carried out for at least 7 days to attain the desired strength. Sampling and testing shall follow relevant IS codes, including IS 456 and IS 516, to ensure compliance with quality standards. The rate shall include all costs associated with labor, material, machinery, batching, transporting, placing, compacting, curing, sampling, testing, and incidental works. Shuttering costs, where required, are also deemed included in the rate of PCC. The work shall be executed with due diligence, adhering to environmental and safety measures, and ensuring compliance with the project’s specifications and MoRTH standards.
All charges for supply & placing of RCC (M-25 grade) in open foundations- All charges for providing and placing RCC M25 grade concrete for foundations as per approved drawings and technical specifications, conforming to MoRTH Sections 1500, 1700, and 2200. The concrete shall be produced using a batch mix plant, transported via transit mixers, and placed in position using appropriate equipment. The mix design, including approved admixtures, shall be submitted for approval by the Engineer-in Charge (EIC) before production. Aggregates shall not exceed a maximum size of 20 mm, and the concrete shall have a workable slump suitable for RCC. Concrete placement shall ensure a free-fall height of less than 1.5 m to avoid segregation and be compacted using mechanical vibrators for proper consolidation. The rate includes all formwork/shuttering costs to support concrete placement, which must ensure safety and stability. Adequate curing shall be performed for at least 7 days, following approved methods, to meet specified strength and durability. Quality control measures include sampling, testing, and certification as per IS codes like IS 456 and IS 516 to verify strength and compliance. Environmental, material handling, and safety protocols shall be adhered to during execution. All incidental costs related to labor, material, machinery, and overheads are deemed included in the scope of work. Refer MoRTH's specification 1500, 1700& 2200. IS Codes: - IS 456
Supplying, fabricating, and erecting mild steel structural frame for DG shed & Car Parking Shed using ISMC/ISA/SHS/RHS sections for columns, trusses, purlins, rafters, and other members; including cutting, welding, grinding, hoisting, and alignment; fixing columns in cement mortar (1:3) in prepared foundations; providing and fixing MS bracings, stiffeners, cleats, base plates, and other necessary fittings; applying one coat of red oxide primer followed by two coats of synthetic enamel paint; and supplying and fixing 0.50 mm thick color-coated galvanized/MS roofing sheets including ridge, overlap, self-drilling screws, washers, and all necessary accessories — complete in all respects as per drawings, specifications, and instructions of the Engineer-in-Charge.
Reinforcement Steel: All charges for providing, cutting, bending, transporting, and tying reinforcement steel of designation TMT FE 500 as per IS 1786 for construction work. The vendor shall supply all necessary steel and 18gauge black annealed binding wire. Reinforcement steel bars are to be cut, bent, and tied per approved bar bending schedules and structural drawings, ensuring precise dimensions and placements. Steel bars shall be securely tied at all intersections using 18-gauge black annealed binding wire to maintain stability during concrete placement. Laps shall conform to MoRTH specifications and as directed in drawings, with no separate payment for laps or overlaps as per MoRTH Clause 1600. Proper clear cover shall be maintained with spacers and chairs as per drawings and CPWD standards. Steel will be measured by weight in kilograms, excluding binding wire and without allowances for overlaps or wastage. The scope of work includes supply, handling, and on-site quality assurance for positioning, alignment, and compliance with specifications and as directed by EIC. Safety measures and quality checks shall be implemented during all stages, ensuring high-standard reinforcement for structural integrity. Reinforcement bars from the approved make shall only be used.
Supplying and fixing 0.50 mm thick color-coated galvanized/mild steel (MS) roofing sheets over the structural steel frame, including necessary overlaps, ridges, hips, valleys, and fixing with self-drilling screws with neoprene washers. Also includes providing and fixing of mild steel bracings, stiffeners, cleats, and other associated accessories for proper anchorage and structural stability. Complete in all respects as per approved drawings, specifications, and directions of the Engineer-in-Charge.
Repairing of water leackage in toilet blocks, admin building & pantry as per requirements including all manpower & consumable charges.
Repairing of water leackage with slicon in Toughened glass as directed by site Incharge including manpower , machinaries , tools & tackles ,transportation etc.,
Providing & Fixing of 75mm Dia PVC Pipe All charges for providing and fixing a 75 mm diameter PVC pipe, conforming to IS 4985 standards, for non-pressure applications as per CPWD specifications. The pipe shall be of approved make and capable of withstanding the required loads. The installation will involve securing the pipe along the specified alignment with corrosion-resistant clamps and fasteners, placed at intervals not exceeding 1 meter, or as directed by the Engineer-in-Charge. The rate shall cover all necessary accessories, including bends, joints, fittings, overlaps, and any cutting or jointing required to complete the installation. The entire system, including pipe layout, fittings, and alignment, must be leak-proof and installed as per drawings. Payment will be made on a running meter (RM) basis, which includes the pipe, clamps, fittings, bends, joints, overlaps, and all associated work, with no separate payment for bends, joints, or overlaps. The rate shall also include labor, transportation, and the necessary installation work to meet specifications. Pipe from the approved make shall only be used.
Supply of Unskilled Labour Supply of unskilled labour for assisting in various site activities such as cleaning, material handling,, shifting of equipment, scaffolding support, , site maintenance, and other general tasks as directed by the Engineer-in-Charge. Labour shall be physically fit and available for work during specified site hours.The rate includes the provision of standard Personal Protective Equipment (PPE) such as safety helmet, high-visibility jacket, safety shoes, gloves, and dust mask, ensuring compliance with safety norms.
Toll plaza Boundary
Construction of boundary wall using precast and prestressed concrete panels of size 2.4 m × 0.3 m × 0.05 m in M-30 grade concrete (1:1.5:3 mix) and precast concrete columns of size 0.15 m × 0.15 m × 2.7 m (including 0.6 m embedded below ground level and 2.1 m above ground level), including: Excavation and concrete work for grouting of columns in position Fixing of precast panels into grooves of the columns to form a rigid wall Applying two coats of primer and paint on the front face of the wall panels All labour, materials, tools and plants, equipment, transportation, scaffolding, and all other incidental works required Complete in all respects as per approved drawings, specifications, and instructions of the Engineer-in-Charge Unit: Running Meter (Rm)
Supply & fixing of MS railing Tubular Steel Railing on Medium Weight steel channel (ISMC series) 100mm X 50mm (Providing fixing eracting 50mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC Series) 100mm X 50mm . 1.2 meters high above ground. 2m centre to center.
Supply and fixing of MS round hollow 50 mm dia pipe in railing at pipe damage and Missing location including painting ,cutting in required size, labour , material and all consumables etc.
Toll Plaza main Gates and DG room Gate
Supplying and fixing of motorized sliding MS gate including all labor, materials, lead, lift, etc., complete, as per the following specifications: Gate Dimensions: 7 feet height, 18 feet total width, with 13 feet sliding on rollers and 5 feet openable manually. 1 -Entry gate Bareilly End (clear Opening size 6.5m *2.8 m) 2 -Main Centre Entry Gate Toll plaza (Clear Opening size 7.5m *2.8 m) 3-Entry Gate Sitapur End (Clear Opening size 5.5m *2.8 m) 4-DG Set Room (Clear Opening size 4.5m *2.8 m) Material Specifications: Frame: Mild Steel (MS), IS 2062, Grade A, with thickness 2.5 mm (or as per load-bearing requirements), ensuring structural integrity and durability. Slats/Panels: Mild Steel sheets of 1.6 mm thickness, welded for a rigid structure. Roller System: Heavy-duty MS rollers, 50 mm diameter, designed for smooth operation, mounted on a mild steel rail (size: 100 x 50 mm) to ensure stability and ease of movement. Motor: 1 HP capacity, single-phase motor, suitable for sliding gates, including necessary wiring and connections. The motor’s specifications are given as broad guidelines; final motor specifications shall be confirmed based on the actual drawings submitted by the vendor for approval before fabrication. Openable Section: The 5 feet section shall be manually operable with necessary hinges and locks. Painting: Two coats of high-quality oil-based paint in approved shade for corrosion resistance and aesthetic finish. Installation: Gate to be fixed with MS anchor bolts to a concrete foundation. The rail system and rollers shall be aligned and levelled for smooth movement, as per approved installation methodology. Testing and Commissioning: The gate, motor, and sliding mechanism will undergo functional testing, ensuring proper operation and smooth sliding. Safety: Compliance with relevant safety standards during installation and operation. Exclusions: Remote control, automatic locks, intercom systems, safety sensors, or any additional automation are excluded from the rate and shall be paid separately. Cost includes all labor, materials, transportation, tools, fabrication, welding, grinding, polishing, painting, and installation, including foundation works, anchor bolts, and necessary accessories. The provision of the motor, testing, and commissioning as per the approved drawings and specifications. Gate frame, slats/panels, roller system, and associated hardware. IS Codes: IS 2062: Specification for mild steel material. IS 1038: Design and performance standards for motorized gates. IS 6911:2017: For fabrication and welding of stainless steel, if used for any small components (in case of mixed materials).
Tiles
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Providing and laying Vitrified tiles of 20 mm thick in floor in different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and fixing Heat Resistant Terrace Tiles of 20 mm thick with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and laying Vitrified Skirting tiles of 20 mm thick in different sizes , with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Flushing Cistern P.V.C. 10 lts capacity (low level) (White) (with fittings, accessories and flush pipe)-jaquar or any make equivalent required
Vitreous china squatting plate urinal with top inlet including CI bracket C.P. brass waste 32 mm.-jaquar or any make equivalent required
Vitreous china wall hanging wash basin 450x300 mm with 15 mm C.P. brass tap with elbow operation lever including all fitting ,labour and others consumables like water outlet pipe ,CI Bracket C.P. brass waste 32 mm etc. -jaquar or any make equivalent required
15 mm C.P.brass tap
Jet Spay Faucet
Towel Rod
Towel Ring
Paper holder
Supply and Fitting of PVC Pipe 1" of make Astral & supreme
Supply and Fitting of PVC Pipe 2" of make Astral & supreme
Providing and fixing of rainwater down-take pipe of PVC 100 mm Dia for Admin building rain water drainage, including necessary fittings such as elbows, bends, couplers, shoes, clamps, and fasteners. The pipe shall be fixed to the building using suitable brackets/clamps at regular intervals not exceeding 1.5 meters, ensuring proper alignment and slope for effective drainage. The work includes cutting, jointing, sealing with solvent cement (for PVC), including fixing of all accessories . All work to be completed as per relevant IS codes and direction of Engineer-in-Charge.
Repairing of water leackage in toilet blocks, admin building & pantry as per requirements including all manpower & consumable charges. (50 Nos)
Complete work for providing water supply connection from submersible pump to overhead tank using 1.5” (40 mm) diameter PVC pipe (6 kg/cm²), including supply and laying of pipe, elbows, tees, ball valve, foot valve (if required), fittings, saddles, clamps, drilling, sealing, testing, and commissioning with all necessary labour and materials.
Complete work for laying and connecting 100 mm dia PVC waste water pipeline from Traffic Aid & Medical Aid Building to septic tank, including excavation, sand bedding, supplying and laying of pipe and fittings ( tees,(2 nos) elbow (6 nos), reducers, cleanouts), leak-proof jointing with solvent cement, core-cutting at tank inlet, sealing, testing and commissioning with all required labour, materials, and tools
Supply, installation, testing, and commissioning of ceiling fans, electrical switches, batten lights, ceiling lights, and other related electrical accessories at designated locations as per the instructions of the Engineer-in-Charge, complete in all respects.
Supply and fixing of ceiling light ( LED Type,22 watt, 230 V,round/square panel type
supply and fixing of Modular MCB 32 A for AC ( SP,10KA ISI marked)
Supply and fixing of 12 -module Modular switch board
Supply and fixing of 8 -module Modular switch board
Supply and fixing of 6 -module Modular switch board
Supply and fixing of 3 -module Modular switch board
Supply and Fixing of 16 A Socket ( Modular Type)
Supply and Fixing of 16 A Switch ( Modular Type)
Supply and Fixing of 6 A Socket ( Modular Type)
Supply and Fixing of 6 A Switch ( Modular Type)
Supply and fixing of fan regulator( Modular,5 step)
Supply and fixing of blank plate for unused module slots
Supply and Fixing of MCB Box for 3 phase distribution system
Supply and fixing of indicator lamp ( neon type,modular, 230v)
Supply and fixing of 4 Module Modular switch Board
Supply and Fixing of Exhaust Fan ( 230 mm seep,230 V, Plastic boady)
Supply and Fixing of Wall Mounted Fan ( 400 mm seep,230 V, Plastic boady, oscillating type)
Supply and fixing of LED bulb 10 W, B22 Base,6500 K cool white
Wall Conduit wiring with grove cutting & Fixing of PVC conduit ( 20 mm ) excluding wire
Supply and Fixing of GI metal Box 12 Module including slot cutting
Supply and Fixing of Round electrical Junction Box ( PVC) including slot cutting
Supply and fixing of 32 amp MCB in existing MCB box
Supply and fixing of Batten light ( LED tube light ,50Watt with metal body
Supply and fixing of Ceilling fan 1200 mm sweep,230v , double ball bearing, ISI marked
Supply of copper conductor PVC insulated wire of 1.5 sq.mm (Red), in standard bundle/coil of 90 meters length, to be laid at specified locations as directed by Engineer-in-Charge.
Supply of copper conductor PVC insulated wire of 2.5 sq.mm (Red), in standard bundle/coil of 90 meters length, to be laid at specified locations as directed by Engineer-in-Charge.
Supply of 25 mm diameter flexible round PVC electrical conduit pipe, including provision of all necessary conduit accessories such as bends, clamps, couplers, saddles, junctions, and other required fittings, for unforeseen or contingent electrical wiring installations. Materials to be supplied and laid at site locations as per actual requirements and directions of the Engineer-in-Charge, ensuring proper alignment, secure mounting, and compliance with relevant electrical standards and specifications, complete in all respects.
Supply of 25 mm conduit tube, including provision of all necessary conduit accessories such as bends, clamps, couplers, saddles, junctions, and other required fittings, for unforeseen or contingent electrical wiring installations. Materials to be supplied and laid at site locations as per actual requirements and directions of the Engineer-in-Charge, ensuring proper alignment, secure mounting, and compliance with relevant electrical standards and specifications, complete in all respects.
Description
Breadth
First floor:
Control Room
Ground Floor:
Operation Manager Room
Admin Room
Miscellaneous
Unforseen partition work in admin building
Description
Breadth
Ground floor:
Plaza Manager Room
Reception Area
Admin Room
Store Room
First Floor:
Electrical Meter ROOM :
LT ROOM :
MEDICAL AID ROOM :
SECURITY ROOM :
WEIGH BRIDGE BUILDING
HIGHWAY MINI NEST :
Description
Breadth
Ground floor:
Admin Room
Operation manager Room
Reception area hall
Traffic Aid Post
First Floor:
Total>>>>
Description
Breadth
Ground floor:
Pantry Room
Toilet
Manager Room
Entrance gate
Store Room
Admin room
Outer toilet
Medical Aid Post
Traffic Aid Post
Description
Breadth
Description
Breadth
Lane Booth Cabin Repair/Rreversible Lane Booth Repair-Repair of booth cabins including ACP sheet & Toughened Glass window with scope including materials , manpowers,Transportations etc.,
ACP panel repair including frame etc Consider 30% of total area
Glass Repair/Replacement including frame etc Consider 20% of total area
Description
Breadth
Fabrication of work station
Fabrication and Fixing of Work station 1st Floor maintenance room
Fabrication and Fixing of Work station Ground Floor admin room
Storage cabinet
Fabrication and Fixing of Storage cabinet 1st Floor maintenance room
Fabrication and Fixing of Storage cabinet 1st Floor maintenance room
Storage Almirah
Fabrication and Fixing of Storage Almirah of full lenth 1st Floor maintenance room and Ground Floor
Description
Breadth
Route Marker NH30 Reflective sticker only-Supply and fixing of Retro reflective sticker TYPE 11 The scope includes crane charges during fixing on canopy , materials, manpower , ideal charges if any etc, Route Marker NH30 sticker only
Public Toilet Sign Board with NHAI Logo and Route marker sign-Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of TYPE 11 (Make : 3M Only) reflective sheeting vide clause 801.3 /IRC, fixed over aluminium sheeting, 1.5 mm thick and fixed in toilet building walls.
Extra wide /Oversized vehicle Lane Sign Board with NHAI Logo and Lane1-Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of TYPE 11 (Make : 3M Only) reflective sheeting vide clause 801.3 /IRC, fixed over aluminium sheeting, 1.5 mm thick and fixed in canopy lane 1. frame.
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of TYPE 11 (Make : 3M Only) reflective sheeting vide clause 801.3 /IRC, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post85 & 100 x 6 mm firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) Scope including 10 years of 3M Warrnety ceritificate.
Supply & fixing of Two way Hazard Marker Size- 950*450 with Either side sign Size-600*600 with base plate 450 *450 mm anchoring on Concrete
Madatory Signbaord Stop : OCTAGONAL Size : 750 mm
TOLLPLAZA ADMIN BUILDING (EXTERIOR)
Description
Breadth
Ground floor:
Van Room
Cashup Room
Admin Room
Gallery
Plaza Manager Room
Reception Area
Pantry Area
Toilet Gents
Front Window Deduction
Gents Toilet Outside
Store Room
First Floor:
UPS Room
Server Room
Gallery
Electrical Meter ROOM PAINTING:
LT ROOM PAINTING:
DG ROOM PAINTING:
MEDICAL AID ROOM PAINTING:
SECURITY ROOM PAINTING:
WEIGH BRIDGE BUILDING PAINTING:
HIGHWAY MINI NEST PAINTING:
TOILET BLOCK PAINTING:
NORMAL BOOTH PAINTING:
REVERSABLE BOOTH PAINTING:
Tunnel Painting
Description
Breadth
Electric Pole painting
Painting Of transformer and Transmission Electic pole Of Toll plaza premises upto 11 m Height
Description
Breadth
Providing and fixing of M25 Grade drainage slab with scope including materials , manpower, transportations etc.,
Providing and fixing of MS structural members for Car & DG Shed with scope including materials , manpower, transportations etc.
DG Shed
MS 75mm sqare heavy duty
50 mm square longitudinal truss
50 mm square longitudinal truss
Car Parking Shed
Supply & Fixing of GI sheet for DG shed & Car Parking shed with scope including materials , manpower, transportations etc.,
Dismantling of RCC/PCC upto 100mm
Toilet Block Misc. Items
Water Cooler
Exhaust Fan
Supply of Unskilled Labour
Brick works : Unforseen repairing work
M15 Concrete : Unforseen repairing work
Door Closer for Admin Buildings etc.,
Repairing of water leackage in Toughened glass of Control room
Down Take pipe for toll plaza canopy with elbow
Foundation Concrete M-15
DG shed
Car shed
Description
Breadth
Edge Plants for beautification
Plants for Toll Island
Executive In door Plants
Executive Out door Plants
Supply of fox tail palm trees for entrance/exit gates
Description
Breadth
Toll Separator Kerb, Crash Barrier & Bullnose Painting
Separator
Bullnose
Safety pipe railing 100mm dia MS Pipe re-painting with scope including 2 coats of enamel paints:
MS Round pipe railing 50mm dia MS Pipe re-painting with scope including 2 coats of enamel paints: Post height 1.3m
MS Parking Shed re-painting with scope including 2 coats of enamel paints
For 2 nos
Application of 2 coats enamel paint on Roller shutter on Van room with scope including paint , manpower, tools & tackles etc.,
Tunnel Booth Stairs Painting
Description
Breadth
Description
Breadth
Casting of RCC new jercy crash barrier for traffic channelization at Toll plaza . (M-25)
Steel
Description
Breadth
Precast and prestressed boundary wall including paiting in front face
MS Round Pipe Railing in plaza premises in damaged/gap location including painting
Supply of MS round PIPE of 50 mm dia for railing including enamel painting two coats
Description
Breadth
Toll plaza Entry /Exit gates
Excavation in granular and all types of soils
PCC for Open foundation work M-15
Column wall footing- M25
Column wall RCC -M25
Steel
Supply of MS gate for Entry/Exit and DG room
Entry gate Bareilly End (clear Opening size 6.5m *2.8 m)
Main Centre Entry Gate Toll plaza (Clear Opening size 7.5m *2.8 m)
Entry Gate Sitapur End (Clear Opening size 5.5m *2.8 m)
DG Set Room (Clear Opening size 4.5m *2.8 m)
Description
Breadth
Chequerred Tiles
Providing and fixing of Terra Cotta Checkerd Tiles in Drain cum footpath and Public toilet Area.
Providing and fixing of Checkerd Tiles Under DG shed
Providing and fixing of Checkerd Tiles in Drain cum footpath and Public toilet Area.
Highway Nest
Providing and fixing of Heat Resistence Tiles in plaza admin building with scope including materials , manpower, transportations etc.,
Terrace Area
Providing and fixing of Floor Tiles with scope including materials , manpower, transportations etc.,
Stair Case Tiles
Providing and fixing of Skirting Floor Tiles with scope including materials , manpower, transportations etc.,
Mini Nest Floor Tiles Skerting
Supply & Fixing of Granite Stone Furnished with moulding (polished) above 0.50 sqm slab 18mm thick as per standard specifications.
Description
Breadth
Vertical Column
Top Truss Member
Diagonal Truss Member
Bottom Truss Member
Description
Breadth
Flushing Cistern P.V.C. 10 lts capacity (low level) (White) (with fittings, accessories and flush pipe)
Vitreous china squatting plate urinal with top inlet including CI bracket C.P. brass waste 32 mm.
Vitreous china wall hanging wash basin 450x300 mm with 15 mm C.P. brass tap with elbow operation lever including all fitting ,labour and others consumables like water outlet pipe ,CI Bracket C.P. brass waste 32 mm etc.
15 mm C.P.brass tap
Jet Spay Faucet
Towel Rod
Towel Ring
Paper holder
PVC Pipe 1"
PVC Pipe 2"
Down Take pipe with elbow for admin and Traffic Aid building & Public Toilet Blocks
Water Supply Connection to over head tank of traffic Aid Building from submersible point
Description
Server Room no. 4 (First Floor)
Ceiling Light
Ceiling fan
6 Modular Switch Board
3 Modular Switch Board
16 Amp Socket
16 Amp Switch
6 Amp Socket
6 Amp Switch
Regulator
Blank
Batten light
UPS Room ( ATMS)
MCB Box
12 Modular Switch Board
LED Bulb
Ceiling Light
16 Amp Socket
16 Amp Switch
6 Amp Switch
Wall Mounted Switch Board
Batten light
Control Room No. 3
12 Modular Switch Board
Ceiling fan
Ceiling Light
Switch Board with 3 Socket
6 Modular Switch Board
3 Modular Switch Board
Batten light
6 Amp Switch
6 Amp Socket
16 Amp Socket
16 Amp Switch
Regulator
Blank
Modular MCB- 32 Amp for AC
Wall conduiting with groove cutting
GI metal box 12 Module
Round electrical junction box
Gallery - First Floor
Ceiling Light
LED Bulb
12 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Blank
Wall conduiting with groove cutting
GI metal box 12 Module
Round electrical junction box
Room No. 2 (First Floor)
Modular MCB
12 Modular Switch Board
6 Modular Switch Board
LED Bulb
Ceiling fan
6 Amp Switch
6 Amp Socket
16 Amp Socket
16 Amp Switch
Blank
Ceiling Light
Regulator
Room No. 1 (First Floor)
12 Modular Switch Board
6 Modular Switch Board
3 Modular Switch Board
Regulator
Ceiling Light
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Batten light
Room No. 5 (First Floor)
12 Modular Switch Board
6 Modular Switch Board
3 Modular Switch Board
Regulator
Ceiling Light
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
LED Bulb
Modular MCB- 32 Amp for AC
Room No. 6 (ATMS Room)
12 Modular Switch Board
6 Modular Switch Board
3 Modular Switch Board
Ceiling fan
Regulator
Ceiling Light
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Batten light
Wall Mounted 12 Modular Switch Board
Indicator
16 Amp Socket
16 Amp Switch
Modular MCB- 32 Amp for AC
Wall conduiting with groove cutting
Round electrical junction box
UPS Room TMS (First Floor)
3 Modular Switch Board
6 Modular Switch Board
16 Amp Switch
6 Amp Switch
Blank
Batten light
Modular MCB- 32 Amp for AC
Ground Floor
Description
HR Room (Ground Floor)
12 Modular Switch Board
6 Modular Switch Board
3 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Regulator
Ceiling Light
Batten Light
Blank
VAN Room (Ground Floor)
12 Modular Switch Board
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Ceiling fan
Regulator
Ceiling Light
Batten Light
Blank
Cash Room (Ground Floor)
6 Modular Switch Board
3 Modular Switch Board
6 Amp Switch
6 Amp Socket
Ceiling fan
Batten Light
Wall Mounted Junction Box
Reception Hall
12 Modular Switch Board
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Ceiling Fan
Regulator
Ceiling Light
LED Bulb
4 Modular Switch Board
Blank
Round Sheet
Ceiling Light
Additional Wiring Required
Pantry Room (Ground Floor)
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
Exhaust Fan
Batten Light
Men's Toilet (Inner Building)
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
Exhaust Fan
Batten Light
Women's Toilet (Inner Building)
4 Modular Switch Board
16 Amp Socket
6 Amp Switch
Batten Light
Men's Toilet (Outer Building)
6 Modular Switch Board
6 Amp Socket
6 Amp Switch
Exhaust Fan
Batten Light
Store Room (Outer Building)
6 Modular Switch Board
3 Modular Switch Board
4 Modular Switch Board
Batten Light
16 Amp socket
16 Amp switch
6 Amp Socket
6 Amp Switch
Regulator
Manager's Room
12 Modular Switch Board
6 Modular Switch Board
4 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Ceiling fan
Regulator
Ceiling Light
Batten Light
Blank
Wiring Required
Medical Aid Post
8 Modular Switch Board
16 Amp switch
6 Amp Socket
6 Amp Switch
Ceiling fan
Ceiling Light
Exhaust Fan
Holder
Traffic Aid Post
8 Modular Switch Board
16 Amp switch
6 Amp Socket
6 Amp Switch
Ceiling Light
Exhaust Fan
Holder
Exhaust Fan
32 Amp MCB
Guard Room
8 Modular Switch Board
16 Amp socket
Regulator
Regulator
32 Amp MCB
25 Amp MCB
DG Room
Batten Light
Wiring + Conduiting
6 Amp Switch Board
4 Modular Switch Board
Blank
LT Room
8 Modular Switch Board
6 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Holder
32 Amp MCB
Meter Room
8 Modular Switch Board
6 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Holder
32 Amp MCB
25 Amp MCB
Regulator
Toilet Block BHS
8 Modular Switch Board
3 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Batten Light
Ceiling Light
Exhaust Fan
Regulator
32 Amp MCB
MCB Box Missing
Static Weigh Bridge BHS
6 Modular Switch Board
3 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Blank
25 Amp MCB
32 Amp MCB
LED Bulb
Highway Mini Nest BHS
12 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Batten Light
LED Bulb
Blank
Wall Mounted Fan
All Booths
Guard Room
Highway Nest Mini
Control Room
Cash Up Room
Static Weigh Bridge
Description of work
Partition Wall
This item includes the supply, fabrication, and installation of Heavy duty aluminum (100mmx 50mmx 3mm) Partion Wall comprising frames and shutters, as per the approved architectural and engineering drawings. Aluminum sections shall conform to IS 733 and IS 1285, made from grade 6063 T5, and black powder-coated to a minimum thickness of 50 microns. EPDM rubber/neoprene gaskets and silicon sealants, as per IS 15477, shall be used for sealing and water resistance at all junctions. 6mm thick float glass panelling shall be used for panneling work. The make for aluminum sections shall be or equivalent to Jindal or Hindalco standard sections. In case the material is procured from a manufacturer other than Jindal or Hindalco, approval shall be sought from the Engineer-in-Charge, and any material benefit should be passed on to the client. Frames and shutters shall be fixed using dash fasteners and stainless steel screws. Accessories like cleat angles, aluminum beading, heavy-duty 5" hinges (3 numbers), tower bolts, door locks, door handles, glass Panel are included in the rate. All work complete in all respect. Fabrication shall begin only after approval of shop drawings by the Engineer-in-Charge. Measurement and Payment will be based on Sqm Basis
Doors and Windows
Repairing, Replacement of Existing aluminum doors, windows, and ventilators aluminum section. Replacement of aluminum section shall be matched with existing existing aluminum section. The work shall be including of removal of exsting damed alumunim section, fixing of new aluminum section, replacement of existing EPDM rubber, replacement of damaged cleat angles, aluminum beading, hinges, tower bolts, window locks, handles if any required shall be including in the rate. Payment will be based on the sqm, sqm shall be calcuated in opening portion of Doors and windows.
This item includes the supply, fabrication, and installation of Heavy duty aluminum (100mmx 50mmx 3mm) aluminum doors, windows, and ventilators, comprising frames and shutters, as per the approved architectural and engineering drawings. Aluminum sections shall conform to IS 733 and IS 1285, made from grade 6063 T5, and black powder-coated to a minimum thickness of 50 microns. EPDM rubber/neoprene gaskets and silicon sealants, as per IS 15477, shall be used for sealing and water resistance at all junctions. 6mm thick float glass panelling shall be used for panneling work. The make for aluminum sections shall be or equivalent to Jindal or Hindalco standard sections. In case the material is procured from a manufacturer other than Jindal or Hindalco, approval shall be sought from the Engineer-in-Charge, and any material benefit should be passed on to the client. Frames and shutters shall be fixed using dash fasteners and stainless steel screws. Accessories like cleat angles, aluminum beading, heavy-duty 5" hinges (3 numbers), tower bolts, door locks, door handles, glass Panel are included in the rate.This item also covers the replacement of damaged aluminum doors, windows, and ventilators, with no extra payment for dismantling or stacking materials within the premises. All work complete in all respect. Fabrication shall begin only after approval of shop drawings by the Engineer-in-Charge. Measurement and Payment will be based on Sqm Basis
Supply and fixing the granite stone of approved shade for jambs/cills of doors & windows of the builing(location specified herein below),complete in all respects with finishing work, as per the direction of the engineer in charge. Specifications: - Material: 18mm thick granite stone - Width: 1 foot (approximately 305 mm) Locations: - All doors: head and jamb (3 sides) - All windows: Cill, jamb, and head (4 sides) Inclusions: - Supply of granite stone in approved shade. - Cutting and shaping of stone to fit the specified locations. - Fixing of stone at the specified locations. - Completing all necessary finishing work. -2mm Chamfering of open edges.
Providing and fixing of new door closer with approved good quality of brand etc., (Brand : Godrej)
All charges for providing and fixing of vertical executive curtains with scope including manpower , machinaries , tools & tackles , transportations etc.,
Toll Booths:
Replacement of Existing ACP with 4mm ACP sheet at Toll Booth. The work including of supply and fixing of new ACP sheet, Removal of existing ACP sheet, all work complete
Replacement of 6mm Toughened Glass and Repair of Aluminium Frame for Toll Plaza Booth Window This item covers the replacement of a 10mm thick toughened glass pane and the repair of the aluminium frame for a toll plaza booth window. The glass shall be of IS 2553 (Part 2) compliant quality, assumed to be 1.5m x 1.5m in size, fixed using silicone sealant and appropriate fasteners. The damaged aluminium section will be replaced with Grade 6063 or equivalent aluminium as per IS 733, with welding, grinding, and finishing of the frame to ensure strength and stability. The work includes necessary labor, scaffolding, and the cleaning of the glass after installation. Transport and handling costs for materials and access equipment are included, assuming typical site conditions and access for the work. Payment will be based on the sqm basis of windows replaced. Any variation in glass size or frame profile will be addressed through mutual agreement. This item excludes additional work such as replacement of other frames or glass beyond the specified scope. All work will conform to IS 2553 and IS 733, and the installation will follow standard practices for toll booth windows in India. The unit of measurement is Sqm with all materials, labor, and transportation included.
PAINTING WORKS:
Providing and Applying Primer, Putty, and Emulsion Paint to Interior Surfaces (Building) This item covers the preparation and application of 1 coat of putty (1mm thickness), 1 coat of primer, and 2 coats of Apcolite Premium Emulsion or an equivalent emulsion paint in the approved shade ( off-white with blue bands) to the interior surfaces of the building. The work includes thorough cleaning of the surface to remove dirt, dust, oil, grease, efflorescence, and any other contaminants. After cleaning, the surface will be treated with 1mm thick putty to smoothen the surface, followed by the application of a coat of primer and two coats of emulsion paint. The work will be completed as per MoRTH Clause 800, CPWD Specifications 500, and the directions of the Engineer-in-Charge. The final price includes the cost of all materials (primer, putty, emulsion paint), labor for surface preparation, cleaning, application of putty, primer, and paint, transportation of materials to the site, overheads, profit, and any required machinery for application. Relevant Standards: MoRTH Clause 800: Painting and Surface Finishing Work CPWD Specification 500: Finish for Internal Walls, including Use of Putty and Emulsion Paint IS 15489: Code of Practice for Painting of Concrete Surfaces IS 5410: Specification for Weather-Resistant Paints for Exterior Use (for the use of emulsion)
Providing and Applying Primer and Weatherproof Paint to Exterior Surfaces (Building) This item includes the preparation and application of 1 coat of primer and 2 coats of weatherproof paint in the approved shade((off-white with blue bands)) to the exterior surfaces of the building. The work involves thoroughly cleaning the surface to remove all dirt, dust, oil, grease, efflorescence, and other contaminants that could affect paint adhesion. After cleaning, a coat of primer is applied, followed by two coats of weatherproof paint, ensuring a durable and uniform finish. The work will be carried out in accordance with MoRTH Clause 800, CPWD specifications, and the directions of the Engineer-in-Charge. The final price includes the cost of all materials (primer, weatherproof paint), labor for surface preparation, cleaning, application of primer and paint, transportation of materials to the site, overheads, profit, and any required machinery for application. Relevant Standards: MoRTH Clause 800: Painting and Surface Finishing Work CPWD Specification 305: Surface Preparation and Painting Work for Exterior Surfaces IS 5410: Specification for Weather-Resistant Paints for Exterior Use
Providing and applying two coats enamel paint (First Quality of Asian/Berger/Nerolac) This item includes the preparation and application of 2 coats of synthetic enamel paint in the approved shade to the Kerb surfaces. The work involves thoroughly cleaning the surface to remove all dirt, dust, oil, grease, efflorescence, Soil and other contaminants that could affect paint adhesion. After cleaning two coats of synthetic enamel paint, ensuring a durable and uniform finish. The work will be carried out in accordance with MoRTH Clause 803, and the directions of the Engineer-in-Charge. The final price includes the cost of all materials, labour for surface preparation, cleaning, application of paint, transportation of materials to the site, overheads, profit, Safety during the work and any required machinery for application. Relevant Standards: MoRTH Clause 803: Painting and Surface Finishing Work
Application of Synthetic Enamel Paint over Steel Structure (Old Surface) This item includes the removal of old paint, surface preparation, and the application of one coat of red oxide primer and two coats of synthetic enamel oil paint on steel surfaces like sheets, trusses, and supporting posts. The old paint shall be removed using manual means or mechanical methods such as wire brushing, scraping, or buffing, as per IS 1477 (Part 1). The surface shall be cleaned of rust, loose paint, and contaminants. Material Specifications Primer: Red oxide primer of approved make (e.g., Asian or equivalent), applied at a thickness of 25-30 microns. Paint: Two coats of synthetic enamel oil paint (e.g., Asian or equivalent), applied at a thickness of 35-40 microns per coat, in the approved shade. Compliance and Quality Control Work must comply with IS 1477 (Part 1) for surface preparation and IS 2395 for paint application. The finish must be free of defects and verified by the Engineer-in-Charge. Measurement and Payment Measurement shall be based on the area of steel surfaces to be painted. The rate includes all labor, materials, and surface preparation. No separate payment will be made for paint removal.
Application of Synthetic Enamel Paint over 100 mm dia MS Pipe safety Pipe for Booth This item includes the removal of old paint, surface preparation, and the application of one coat of red oxide primer and two coats of synthetic enamel oil paint on steel surfaces like sheets, trusses, and supporting posts. The old paint shall be removed using manual means or mechanical methods such as wire brushing, scraping, or buffing, as per IS 1477 (Part 1). The surface shall be cleaned of rust, loose paint, and contaminants. Material Specifications Primer: Red oxide primer of approved make (e.g., Asian or equivalent), applied at a thickness of 25-30 microns. Paint: Two coats of synthetic enamel oil paint (e.g., Asian or equivalent), applied at a thickness of 35-40 microns per coat, in the approved shade. Compliance and Quality Control Work must comply with IS 1477 (Part 1) for surface preparation and IS 2395 for paint application. The finish must be free of defects and verified by the Engineer-in-Charge. Measurement and Payment Measurement shall be based on the RMT of steel Pipe to be painted. The rate includes all labor, materials, and surface preparation. No separate payment will be made for paint removal.
MS Round pipe railing 50mm dia MS Pipe re-painting with scope including 2 coats of enamel paints: Post height 1.3m This item includes the removal of old paint, surface preparation, and the application of one coat of red oxide primer and two coats of synthetic enamel oil paint on steel surfaces like sheets, trusses, and supporting posts. The old paint shall be removed using manual means or mechanical methods such as wire brushing, scraping, or buffing, as per IS 1477 (Part 1). The surface shall be cleaned of rust, loose paint, and contaminants. Material Specifications Primer: Red oxide primer of approved make (e.g., Asian or equivalent), applied at a thickness of 25-30 microns. Paint: Two coats of synthetic enamel oil paint (e.g., Asian or equivalent), applied at a thickness of 35-40 microns per coat, in the approved shade. Compliance and Quality Control Work must comply with IS 1477 (Part 1) for surface preparation and IS 2395 for paint application. The finish must be free of defects and verified by the Engineer-in-Charge. Measurement and Payment Measurement shall be based on the RMT of steel Pipe to be painted. The rate includes all labor, materials, and surface preparation. No separate payment will be made for paint removal.
MISCELLANEOUS WORKS:
1st Class Brick Masonry Work in Cement Mortar 1:3 This item includes the construction of brick masonry using 1st class burnt clay bricks, laid in cement mortar of mix ratio 1:3 (Cement: Sand), for foundations, walls, piers, columns, and other structures as per the approved drawings and technical specifications, from ground level till plinth and in superstructure above plinth level up to floor five level. The work includes thoroughly soaking the bricks in water for a minimum period of one hour prior to laying them to ensure proper bonding and to achieve maximum strength. The work shall also involve the protection of the green structure from rain during curing by suitable coverings. Curing of the masonry shall be done for a minimum period of 7 days as per standard practices to ensure the proper hydration and strength development of the mortar and masonry. The work excludes the cost of pointing, plastering, or any additional finish unless specified otherwise. The work shall be executed in accordance with the relevant CPWD and IS specifications. The final price includes the cost of procurement of 1st class bricks, cement, sand, and other necessary materials, including royalty charges, transportation to site, soaking of bricks, labor, machinery, curing, and all overheads and profit. The cost does not include pointing, plastering, or any decorative finishes unless specified separately. Safety measures and quality checks shall be implemented during all stages. Relevant Standards: CPWD Specification No. 6.4 (Brick Masonry Work) MoRTH Clause 1300 (Brick Masonry Work)
Plaster (20 mm Thick in Two Layers with Waterproofing Compound) The work includes 20 mm thick external plaster in two layers as per CPWD Clause 13. cement mortar 1:3 (1 cement: 3 fine sand) applied. The work includes raking joints, cleaning, surface preparation, uniform application of both layers, curing as specified, and ensuring a smooth finish. The cost includes all materials (cement, sand, waterproofing compound, water), labor, curing, scaffolding, and quality checks. Measurement shall be in Sqm of finished plastered area. The work shall conform to IS 1661:1980 and CPWD specifications. Rate is applicable from plinth level to floor five level.
Providing and laying integral cement‑based waterproofing treatment with brick‑bat coba over RCC slab and parapet walls up to 300 mm heights, as per CPWD Spec 22.7: including surface cleaning , scrapping, cleaned neatly of all morter dropping, loose material with brooms/cloth,first slurry coat (2.75 kg/m²), laying 25–115 mm brick‑bats with 1:5 mortar bed and waterproofing compound, second slurry coat after 2 days, finishing layer of 20 mm cement mortar (1:4) with fibreglass cloth membrane and 300×300 mm surface pattern, complete curing and testing (ponding for 14 days). Rate to include all materials, waterproofing compound, fibreglass, labour, curing, testing, and no deductions for openings up to 0.40 m².
Plain Cement Concrete M-15 Grade in Open Foundation All charges for supply & placing of Plain Cement Concrete (M-15 grade) in open foundations as per approved drawings and technical specifications, conforming to MoRTH Sections 1500, 1700, and 2200. The mix shall use aggregates of size not exceeding 20 mm, with a workable slump suitable for PCC. The thickness of PCC shall be as specified in drawing. Concrete placement shall ensure a free-fall height of less than 1.5 m to prevent segregation, compacted using mechanical vibrators to achieve proper consolidation. The work includes the preparation of the foundation surface, leveling, placing concrete, and finishing exposed surfaces to achieve the required levels and smoothness. Adequate curing, as per approved methods, shall be carried out for at least 7 days to attain the desired strength. Sampling and testing shall follow relevant IS codes, including IS 456 and IS 516, to ensure compliance with quality standards. The rate shall include all costs associated with labor, material, machinery, batching, transporting, placing, compacting, curing, sampling, testing, and incidental works. Shuttering costs, where required, are also deemed included in the rate of PCC. The work shall be executed with due diligence, adhering to environmental and safety measures, and ensuring compliance with the project’s specifications and MoRTH standards.
Supplying, fabricating, and erecting mild steel structural frame for DG shed & Car Parking Shed using ISMC/ISA/SHS/RHS sections for columns, trusses, purlins, rafters, and other members; including cutting, welding, grinding, hoisting, and alignment; fixing columns in cement mortar (1:3) in prepared foundations; providing and fixing MS bracings, stiffeners, cleats, base plates, and other necessary fittings; applying one coat of red oxide primer followed by two coats of synthetic enamel paint; and supplying and fixing 0.50 mm thick color-coated galvanized/MS roofing sheets including ridge, overlap, self-drilling screws, washers, and all necessary accessories — complete in all respects as per drawings, specifications, and instructions of the Engineer-in-Charge.
Supplying and fixing 0.50 mm thick color-coated galvanized/mild steel (MS) roofing sheets over the structural steel frame, including necessary overlaps, ridges, hips, valleys, and fixing with self-drilling screws with neoprene washers. Also includes providing and fixing of mild steel bracings, stiffeners, cleats, and other associated accessories for proper anchorage and structural stability. Complete in all respects as per approved drawings, specifications, and directions of the Engineer-in-Charge.
Repairing of water leackage in toilet blocks, admin building & pantry as per requirements including all manpower & consumable charges.
Providing & Fixing of 75mm Dia PVC Pipe All charges for providing and fixing a 75 mm diameter PVC pipe, conforming to IS 4985 standards, for non-pressure applications as per CPWD specifications. The pipe shall be of approved make and capable of withstanding the required loads. The installation will involve securing the pipe along the specified alignment with corrosion-resistant clamps and fasteners, placed at intervals not exceeding 1 meter, or as directed by the Engineer-in-Charge. The rate shall cover all necessary accessories, including bends, joints, fittings, overlaps, and any cutting or jointing required to complete the installation. The entire system, including pipe layout, fittings, and alignment, must be leak-proof and installed as per drawings. Payment will be made on a running meter (RM) basis, which includes the pipe, clamps, fittings, bends, joints, overlaps, and all associated work, with no separate payment for bends, joints, or overlaps. The rate shall also include labor, transportation, and the necessary installation work to meet specifications. Pipe from the approved make shall only be used.
Supply of Unskilled Labour Supply of unskilled labour for assisting in various site activities such as cleaning, material handling,, shifting of equipment, scaffolding support, , site maintenance, and other general tasks as directed by the Engineer-in-Charge. Labour shall be physically fit and available for work during specified site hours.The rate includes the provision of standard Personal Protective Equipment (PPE) such as safety helmet, high-visibility jacket, safety shoes, gloves, and dust mask, ensuring compliance with safety norms.
All charges for repairing of canopy Drainage rainwater-charges for repairing of canopy Drainage rainwater collective line leakage (U shape type in GI Sheet)
Repair of damaged PQC around toll booths using microconcrete- Repair of damaged PQC around toll booths using microconcrete including dismantling of esisting pqc upto 100 mm depth,surface cleaning,application of bonding agent( Nito Bond EP orEquivalent) placing of non shrink micro concrete ,curing,surface finishing,and disposal of debris including all material,labours,tools, machinery, transportation etc as per the direction of EIC.
All charges for supply & placing of RCC (M-25 grade) in open foundations- All charges for providing and placing RCC M25 grade concrete for foundations as per approved drawings and technical specifications, conforming to MoRTH Sections 1500, 1700, and 2200. The concrete shall be produced using a batch mix plant, transported via transit mixers, and placed in position using appropriate equipment. The mix design, including approved admixtures, shall be submitted for approval by the Engineer-in Charge (EIC) before production. Aggregates shall not exceed a maximum size of 20 mm, and the concrete shall have a workable slump suitable for RCC. Concrete placement shall ensure a free-fall height of less than 1.5 m to avoid segregation and be compacted using mechanical vibrators for proper consolidation. The rate includes all formwork/shuttering costs to support concrete placement, which must ensure safety and stability. Adequate curing shall be performed for at least 7 days, following approved methods, to meet specified strength and durability. Quality control measures include sampling, testing, and certification as per IS codes like IS 456 and IS 516 to verify strength and compliance. Environmental, material handling, and safety protocols shall be adhered to during execution. All incidental costs related to labor, material, machinery, and overheads are deemed included in the scope of work. Refer MoRTH's specification 1500, 1700& 2200. IS Codes: - IS 456
Reinforcement Steel: All charges for providing, cutting, bending, transporting, and tying reinforcement steel of designation TMT FE 500 as per IS 1786 for construction work. The vendor shall supply all necessary steel and 18gauge black annealed binding wire. Reinforcement steel bars are to be cut, bent, and tied per approved bar bending schedules and structural drawings, ensuring precise dimensions and placements. Steel bars shall be securely tied at all intersections using 18-gauge black annealed binding wire to maintain stability during concrete placement. Laps shall conform to MoRTH specifications and as directed in drawings, with no separate payment for laps or overlaps as per MoRTH Clause 1600. Proper clear cover shall be maintained with spacers and chairs as per drawings and CPWD standards. Steel will be measured by weight in kilograms, excluding binding wire and without allowances for overlaps or wastage. The scope of work includes supply, handling, and on-site quality assurance for positioning, alignment, and compliance with specifications and as directed by EIC. Safety measures and quality checks shall be implemented during all stages, ensuring high-standard reinforcement for structural integrity. Reinforcement bars from the approved make shall only be used.
Toll plaza Boundary
Construction of boundary wall using precast and prestressed concrete panels of size 2.4 m × 0.3 m × 0.05 m in M-30 grade concrete (1:1.5:3 mix) and precast concrete columns of size 0.15 m × 0.15 m × 2.7 m (including 0.6 m embedded below ground level and 2.1 m above ground level), including: Excavation and concrete work for grouting of columns in position Fixing of precast panels into grooves of the columns to form a rigid wall Applying two coats of primer and paint on the front face of the wall panels All labour, materials, tools and plants, equipment, transportation, scaffolding, and all other incidental works required Complete in all respects as per approved drawings, specifications, and instructions of the Engineer-in-Charge Unit: Running Meter (Rm)
Toll plaza bounfencing work providing and fixing of diamond type fencing 3 mm with supporting angle in space of center to center 3m with scope including all materials, manpower, machineries etc size 282m* 2.7m
Supply & fixing of MS railing Tubular Steel Railing on Medium Weight steel channel (ISMC series) 100mm X 50mm (Providing fixing eracting 50mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC Series) 100mm X 50mm . 1.2 meters high above ground. 2m centre to center.
Supply and fixing of MS round hollow 50 mm dia pipe in railing at pipe damage and Missing location including painting ,cutting in required size, labour , material and all consumables etc.
Toll Plaza main Gates
Supplying and fixing of motorized sliding MS gate including all labor, materials, lead, lift, etc., complete, as per the following specifications: Gate Dimensions: 7 feet height, 18 feet total width, with 13 feet sliding on rollers and 5 feet openable manually. 1-Entry gate Bareilly End (clear Opening size 6.5m *2.8 m) 2- Main Centre Entry Gate Toll plaza (Clear Opening size 7.5m *2.8 m) 3-Entry Gate Sitapur End (Clear Opening size 5.5m *2.8 m) 4-DG Set Room (Clear Opening size 4.5m *2.8 m) 5-MS Tunnel booth stair Covers of Size ( 1.5*1.2)m (14 Nos) Material Specifications: Frame: Mild Steel (MS), IS 2062, Grade A, with thickness 2.5 mm (or as per load-bearing requirements), ensuring structural integrity and durability. Slats/Panels: Mild Steel sheets of 1.6 mm thickness, welded for a rigid structure. Roller System: Heavy-duty MS rollers, 50 mm diameter, designed for smooth operation, mounted on a mild steel rail (size: 100 x 50 mm) to ensure stability and ease of movement. Motor: 1 HP capacity, single-phase motor, suitable for sliding gates, including necessary wiring and connections. The motor’s specifications are given as broad guidelines; final motor specifications shall be confirmed based on the actual drawings submitted by the vendor for approval before fabrication. Openable Section: The 5 feet section shall be manually operable with necessary hinges and locks. Painting: Two coats of high-quality oil-based paint in approved shade for corrosion resistance and aesthetic finish. Installation: Gate to be fixed with MS anchor bolts to a concrete foundation. The rail system and rollers shall be aligned and levelled for smooth movement, as per approved installation methodology. Testing and Commissioning: The gate, motor, and sliding mechanism will undergo functional testing, ensuring proper operation and smooth sliding. Safety: Compliance with relevant safety standards during installation and operation. Exclusions: Remote control, automatic locks, intercom systems, safety sensors, or any additional automation are excluded from the rate and shall be paid separately. Cost includes all labor, materials, transportation, tools, fabrication, welding, grinding, polishing, painting, and installation, including foundation works, anchor bolts, and necessary accessories. The provision of the motor, testing, and commissioning as per the approved drawings and specifications. Gate frame, slats/panels, roller system, and associated hardware. IS Codes: IS 2062: Specification for mild steel material. IS 1038: Design and performance standards for motorized gates. IS 6911:2017: For fabrication and welding of stainless steel, if used for any small components (in case of mixed materials).
Tiles
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Providing and laying Vitrified tiles of 20 mm thick in floor in different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and fixing Heat Resistant Terrace Tiles of 20 mm thick with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing and laying Vitrified Skirting tiles of 20 mm thick in different sizes , with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
ADMIN BUILDING:Sanitary and Plumbing Fittings-
Flushing Cistern P.V.C. 10 lts capacity (low level) (White) (with fittings, accessories and flush pipe)
Vitreous china squatting plate urinal with top inlet including CI bracket C.P. brass waste 32 mm.
Vitreous china wall hanging wash basin 450x300 mm with 15 mm C.P. brass tap with elbow operation lever including all fitting ,labour and others consumables like water outlet pipe ,CI Bracket C.P. brass waste 32 mm etc.
15 mm C.P.brass tap
Jet Spay Faucet
Towel Rod
Towel Ring
Paper holder
Supply and Fitting of PVC Pipe 1" of make Astral & supreme
Supply and Fitting of PVC Pipe 2" of make Astral & supreme
Repairing of water leackage in toilet blocks, admin building & pantry as per requirements including all manpower & consumable charges. ( 30 points)
Providing and fixing of rainwater down-take pipe of PVC 100 mm dia. for canopy drainage, including necessary fittings such as elbows, bends, couplers, shoes, clamps, and fasteners. The pipe shall be fixed to the buildings using suitable brackets/clamps at regular intervals not exceeding 1.5 meters, ensuring proper alignment and slope for effective drainage. The work includes cutting, jointing, sealing with solvent cement (for PVC), including fixing of all accessories and making connections to the stormwater drain or surface outlet. All work to be completed as per relevant IS codes and direction of Engineer-in-Charge.
Electrcial Works-
Supply, installation, testing, and commissioning of ceiling fans, electrical switches, batten lights, ceiling lights, and other related electrical accessories at designated locations as per the instructions of the Engineer-in-Charge, complete in all respects.
Supply and fixing of ceiling light ( LED Type,22 watt, 230 V,round/square panel type
supply and fixing of Modular MCB 32 A for AC ( SP,10KA ISI marked)
Supply and fixing of 12 -module Modular switch board
Supply and fixing of 8 -module Modular switch board
Supply and fixing of 6 -module Modular switch board
Supply and fixing of 3 -module Modular switch board
Supply and Fixing of 16 A Socket ( Modular Type)
Supply and Fixing of 16 A Switch ( Modular Type)
Supply and Fixing of 6 A Socket ( Modular Type)
Supply and Fixing of 6 A Switch ( Modular Type)
Supply and fixing of fan regulator( Modular,5 step)
Supply and fixing of blank plate for unused module slots
Supply and Fixing of MCB Box for 3 phase distribution system
Supply and fixing of indicator lamp ( neon type,modular, 230v)
Supply and fixing of 4 Module Modular switch Board
Supply and Fixing of Exhaust Fan ( 230 mm seep,230 V, Plastic boady)
Supply and Fixing of Wall Mounted Fan ( 400 mm seep,230 V, Plastic boady, oscillating type)
Supply and fixing of LED bulb 10 W, B22 Base,6500 K cool white
Wall Conduit wiring with grove cutting & Fixing of PVC conduit ( 20 mm ) excluding wire
Supply and Fixing of GI metal Box 12 Module including slot cutting
Supply and Fixing of Round electrical Junction Box ( PVC) including slot cutting
Supply and fixing of 32 amp MCB in existing MCB box
Supply and fixing of Batten light ( LED tube light ,50Watt with metal body
Supply and fixing of Ceilling fan 1200 mm sweep,230v , double ball bearing, ISI marked
Supply of copper conductor PVC insulated wire of 1.5 sq.mm (Red), in standard bundle/coil of 90 meters length, to be laid at specified locations as directed by Engineer-in-Charge.
Supply of copper conductor PVC insulated wire of 2.5 sq.mm (Red), in standard bundle/coil of 90 meters length, to be laid at specified locations as directed by Engineer-in-Charge.
Supply of 25 mm diameter flexible round PVC electrical conduit pipe, including provision of all necessary conduit accessories such as bends, clamps, couplers, saddles, junctions, and other required fittings, for unforeseen or contingent electrical wiring installations. Materials to be supplied and laid at site locations as per actual requirements and directions of the Engineer-in-Charge, ensuring proper alignment, secure mounting, and compliance with relevant electrical standards and specifications, complete in all respects.
Supply of 25 mm conduit tube, including provision of all necessary conduit accessories such as bends, clamps, couplers, saddles, junctions, and other required fittings, for unforeseen or contingent electrical wiring installations. Materials to be supplied and laid at site locations as per actual requirements and directions of the Engineer-in-Charge, ensuring proper alignment, secure mounting, and compliance with relevant electrical standards and specifications, complete in all respects.
Description
Breadth
Providing and fixing of M25 Grade drainage slab with scope including materials , manpower, transportations etc.,
Providing and fixing of MS structural members for Car & DG Shed with scope including materials , manpower, transportations etc.
DG Shed
MS 75mm sqare heavy duty
50 mm square longitudinal truss
50 mm square longitudinal truss
Car Parking Shed
Supply & Fixing of GI sheet for DG shed & Car Parking shed with scope including materials , manpower, transportations etc.,
DG Shed
Car Parking Shed
Dismantling of RCC/PCC upto 100mm
Canopy
Toilet Block Misc. Items
Supply of Unskilled Labour
Brick works : Unforseen repairing work
M15 Concrete : Unforseen repairing work
Door Closer for Admin Buildings etc.,
Down Take PVC pipe 100 mm dia for toll plaza canopy and toilet blocks , Traffic aid post with elbow
Repairing of canopy drainage rain water collective line leakage
Toll Booth Lane PQC Repair with Micro concrete
MS Tunnel booth stair Covers of Size ( 1.5*1.2)m
Foundation Concrete M-15
DG shed
Car shed
Description
Breadth
Toll Separator Kerb, Crash Barrier & Bullnose Painting
Separator
Bullnose
Safety pipe railing 100mm dia MS Pipe re-painting with scope including 2 coats of enamel paints:
MS Round pipe railing 50mm dia MS Pipe re-painting with scope including 2 coats of enamel paints: Post height 1.3m
MS Parking Shed re-painting with scope including 2 coats of enamel paints
For 2 nos
Tunnel Booth Stairs Painting
Description
Breadth
Vertical Column
Top Truss Member
Diagonal Truss Member
Bottom Truss Member
Description
Breadth
First floor:
Control Room
Ground Floor:
Reception Room
Description
Breadth
Ground floor:
Reception Room
Gents Toilet
POS Room
First Floor:
Stairs Window
Electrical Meter ROOM :
LT ROOM :
DG Room:
MEDICAL AID ROOM :
SECURITY ROOM :
WEIGH BRIDGE BUILDING
HIGHWAY MINI NEST :
Description
Breadth
Ground floor:
Traffic Aid Post
First Floor:
Total>>>>
Description
Breadth
Ground floor:
Pantry Room
Entrance gate
Gents Toilet
Ladies Toilet
Public toilet
Medical Aid Post
Traffic Aid Post
Description
Breadth
Description
Breadth
Lane Booth Cabin Repair/Rreversible Lane Booth Repair of booth cabins including ACP sheet & Toughened Glass window with scope including materials , manpowers,Transportations etc.,
ACP panel repair including frame etc Consider 30% of total area
Glass Repair/Replacement including frame etc Consider 20% of total area
Description
Breadth
Fabrication of work station
Fabrication and Fixing of Work station 1st Floor maintenance room
Fabrication and Fixing of Work station Ground Floor admin room
Storage cabinet
Fabrication and Fixing of Storage cabinet 1st Floor maintenance room
Fabrication and Fixing of Storage cabinet 1st Floor maintenance room
Storage Almirah
Fabrication and Fixing of Storage Almirah of full lenth 1st Floor maintenance room and Ground Floor
Description
Breadth
Fastage lane Reflective sticker only-Supply and fixing of Retro reflective sticker TYPE 11 The scope includes crane charges during fixing on canopy , materials, manpower , ideal charges if any etc, Route Marker NH30 sticker only
Public Toilet Sign Board with NHAI Logo and Route marker sign-Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of TYPE 11 (Make : 3M Only) reflective sheeting vide clause 801.3 /IRC, fixed over aluminium sheeting, 1.5 mm thick and fixed in toilet building walls.
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of TYPE 11 (Make : 3M Only) reflective sheeting vide clause 801.3 /IRC, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post85 & 100 x 6 mm firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) Scope including 10 years of 3M Warrnety ceritificate.
Supply & fixing of Two way Hazard Marker Size- 950*450 with Either side sign Size-600*600 with base plate 450 *450 mm anchoring on Concrete
Madatory Signbaord Stop : OCTAGONAL Size : 750 mm
TOLLPLAZA ADMIN BUILDING (EXTERIOR)
Description
Breadth
Ground floor:
Gallery
POS Room
Reception Area
Pantry Area
Toilet Gents
Toilet Ladies
Gents Toilet Outside
First Floor:
UPS Room
Server Room
Gallery
Staircase Area
Electrical Meter ROOM PAINTING:
LT ROOM PAINTING:
DG ROOM PAINTING:
MEDICAL AID ROOM PAINTING:
SECURITY ROOM PAINTING:
WEIGH BRIDGE BUILDING PAINTING:
HIGHWAY MINI NEST PAINTING:
TOILET BLOCK PAINTING:
NORMAL BOOTH PAINTING:
REVERSABLE BOOTH PAINTING:
Tunnel Painting
Description
Breadth
Electric Pole painting
Painting Of transformer and Transmission Electic pole Of Toll plaza premises upto 11 m Height
Description
Breadth
Edge Plants for beautification
Plants for Toll Island
Executive In door Plants
Executive Out door Plants
Supply of fox tail palm trees for entrance/exit gates
Description
Breadth
Reception Room
Cash Room
POS Room
Description
Breadth
Casting of RCC new jercy crash barrier for traffic channelization at Toll plaza . (M-25)
Steel
Description
Breadth
Precast Boundary wall
Provding and fixing of diamond type fencing in plaza premises & transformer and electric area fencing
MS Round Pipe Railing in plaza premises in damaged/gap location including painting
Supply of MS round PIPE of 50 mm dia for railing including enamel painting two coats
Description
Breadth
Toll plaza Entry /Exit gates
Excavation in granular and all types of soils
PCC for Open foundation work M-15
Column wall footing- M25
Column wall RCC -M25
Steel
Supply of MS gate for Entry/Exit and DG room
Entry gate Bareilly End (clear Opening size 6.5m *2.8 m)
Main Centre Entry Gate Toll plaza (Clear Opening size 7.5m *2.8 m)
Entry Gate Sitapur End (Clear Opening size 5.5m *2.8 m)
DG Set Room (Clear Opening size 4.5m *2.8 m)
Entry gate Bareilly End (clear Opening size 5m *2.8 m)
Entry Gate Sitapur End (Clear Opening size 5m *2.8 m)
Description
Breadth
Chequerred Tiles
Providing and fixing of Terra Cotta Chequerred TilesTiles in Drain cum footpath and Public toilet Area.
Providing and fixing of Terra Cotta Chequerred TilesTilesin Drain cum footpath and Public toilet Area.
Heat Resistance Tiles
Terrace Area
Floor Tiles
Gents tolet Admin Building
Supply & Fixing of Granite Stone Furnished with moulding (polished) above 0.50 sqm slab 18mm thick as per standard specifications.
Description
Room No. 1 (First Floor)
Room No. 2 (First Floor)
Regulator
Batten Light
Blank
Air Conditioner
Wiring + Conduit
25amp Modular MCB
Control Room No. 3 (First Floor)
12 Modular Switch Board
8 Modular Switch Board
6 Modular Switch Board
3 Modular Switch Board
Ceiling Fan
Batten Light
6 Amp Switch
6 Amp Socket
16 Amp Socket
16 Amp Switch
Regulator
Blank
Air Conditioner
Wiring + Conduit
25amp Modular MCB
Metal Box (8x6)
Room no. 4 (First Floor)
Ceiling Fan
Air Conditioner
8 Modular Switch Board
6 Modular Switch Board
16 Amp Socket
16 Amp Switch
6 Amp Socket
6 Amp Switch
Regulator
Blank
Batten Light
25amp Modular MCB
Room No. 5 (First Floor)
8 Modular Switch Board
6 Modular Switch Board
Air Conditioner + Wiring + Conduit
25amp Modular MCB
Ceiling Fan
Regulator
Batten Light
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Blank
Room No. 6 (ATMS Room)
12 Modular Switch Board
6 Modular Switch Board
Ceiling Fan
Regulator
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Air Conditioner
Wiring + Conduit
25amp Modular MCB
UPS Room (ATMS First floor)
6 Modular Switch Board
6 Amp Socket
6 Amp Switch
Air Conditioner
Wiring + Conduit
25amp Modular MCB
UPS Room (TMS)
6 Modular Switch Board
6 Amp Socket
6 Amp Switch
Air Conditioner
Wiring + Conduit
25amp Modular MCB
Gallery - First Floor
Batten Light
3 Modular Switch Board
6 Amp Switch
6 Amp Socket
Blank
Room -1 (Ground Floor)
Wiring + Conduit
Wiring + Conduit
Room No. 2 (Ground Floor)
Wiring + Conduit
16 Amp Socket
6 Amp Switch
6 Amp Socket
MCB Box
63 Amp MCB
32 Amp MCB
Room No. 3 (Ground Floor)
Air Conditioner
Wiring + Conduit
25amp Modular MCB
12 Modular Switch Board
6 Modular Switch Board
Ceiling Fan
6 Amp Switch
6 Amp Socket
16 Amp Socket
16 Amp Switch
Blank
Batten Light
Regulator
Reception Hall
12 Modular Switch Board
6 Modular Switch Board
8 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Ceiling Fan
Regulator
Batten Light
Blank
Air Conditioner
Wiring + Conduit
25amp Modular MCB
GI Metal Box 12 Module
Gallery (Ground Floor)
Batten Light
3 Modular Switch Board
6 Amp Switch
6 Amp Socket
Blank
Pantry Room
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Exhaust Fan
Batten Light
Blank
Cash Room
Batten Light
Air Conditioner
Ceiling Fan
8 Modular Switch Board
6 Modular Switch Board
3 Modular Switch Board
Wall mounted Ceiling Fan
16 Amp Switch
16 Amp Socket
6 Amp Switch
6 Amp Socket
Regulator
Blank
Men's Toilet (Inner Building)
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Switch
Exhaust Fan
LED Bulb
Women's Toilet (Inner Building)
4 Modular Switch Board
16 Amp Socket
6 Amp Switch
LED Bulb
Men's Toilet (Outer Building)
3 Modular Switch Board
6 Amp Switch
Blank
LED Bulb
POS Room
8 Modular Switch Board
6 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Batten Light
Blank
Air Conditioner
Wiring + Conduit
25amp Modular MCB
Medical Aid Post
12 Modular Switch Board
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Regulator
Indicator
Exhaust Fan
LED Bulb Holder
Batten Light
Traffic Aid Post
12 Modular Switch Board
6 Modular Switch Board
16 Amp Switch
16 Amp Socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Regulator
Indicator
Exhaust Fan
LED Bulb Holder
Batten Light
Guard Room
8 Modular Switch Board
16 Amp socket
Regulator
Regulator
Ceiling Fan
32 Amp MCB
25 Amp MCB
DG Room
Batten Light
Wiring + Conduit
6 Amp Switch Board
4 Modular Switch Board
Blank
LT Room
8 Modular Switch Board
6 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Holder
32 Amp MCB
Meter Room
8 Modular Switch Board
6 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Holder
32 Amp MCB
25 Amp MCB
Regulator
Toilet Block BHS
8 Modular Switch Board
3 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Tube Light
Exhaust Fan
Regulator
32 Amp MCB
MCB Box Missing
Static Weigh Bridge BHS
6 Modular Switch Board
3 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Blank
25 Amp MCB
32 Amp MCB
LED Bulb
Highway Mini Nest LHS
12 Modular Switch Board
16 Amp switch
16 Amp socket
6 Amp Socket
6 Amp Switch
Ceiling Fan
Tube Light
LED Bulb
Blank
Wall Mounted Fan
Flexible Pipe
Description
Breadth
Flushing Cistern P.V.C. 10 lts capacity (low level) (White) (with fittings, accessories and flush pipe)
Vitreous china squatting plate urinal with top inlet including CI bracket C.P. brass waste 32 mm.
Vitreous china wall hanging wash basin 450x300 mm with 15 mm C.P. brass tap with elbow operation lever including all fitting ,labour and others consumables like water outlet pipe ,CI Bracket C.P. brass waste 32 mm etc.
15 mm C.P.brass tap
Jet Spay Faucet
Towel Rod
Towel Ring
Paper holder
PVC Pipe 1"
PVC Pipe 2"
Down Take PVC pipe 100 mm dia for toll plaza admin and toilet blocks , Traffic aid post Guard Room,DG Room etc with elbow
Repairing of water leackage in toilet blocks, admin building & pantry as per requirements including all manpower & consumable charges.(30 Points)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
metadata.json
RAW_JSON
RFP - Toll Plaza Renovation BSRP NSPPL 08.06.2026.pdf
TENDER_DOCUMENT • 6.49 MB
Annexure C3 BOQ - Faridpur Toll Plaza Renovation Sitapur Bareilly Project_.xlsx
BOQ_DOCUMENT • 0.60 MB
Annexure C3 BOQ - Maigalganj Toll Plaza Renovation Sitapur Bareilly Project_.xlsx
BOQ_DOCUMENT • 0.59 MB
Download all tender documents and submit your bid