Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 LAccepted-AOC 1ST FLOOR SAKTHI BUILDING SOUTH OF STONE BRIDGE IRON BRIDGE 688011 | ALAPPUZHA | ALAPPUZHA | KERALA | 688011 | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.0 L+₹29,690 (10.8%)Rejected-Finance M C ROAD KOTTAYAM KERALA 686001 | KOTTAYAM | KERALA | 686001 | 2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹8,200
Closing Date
13 Feb 2023, 3:00 pmClosed
Assistant Executive Engineer
O/o The Assistant Executive Engineer Electronics Sub Division Kottayam
Revamping of Existing LAN System in Principal Agriculture Office Kottayam and Supply and installation of Local Area Network system in Principal Agriculture Office (Annex) Kottayam
2023_PWD_553203_1
123/AEEELSKTM/2022-23
Open Tender
Miscellaneous Works
Item Wise
45 days
Kottayam
Please refer Tender documents.
9 documents required · 9 mandatory
₹780
₹8,200
22 Jun 2023
27 Jan 2023
16 Feb 2023
27 Jan 2023
13 Feb 2023
27 Jan 2023
Amount
Part I: Revamping of of Existing LAN System,in Principal Agriculture Office Kottayam. Supply,Installation,Testing and Commissioning of Layer 2 manageable 24 port Ethernet Switch with 10/100/1000 ports and 2 Gig SFP and with Life time warranty. Accepted Make: Cisco/HP/Netgear
Supply and Configuration of 8Port Gigabit POE Switch populated with minimum 2 SFP ports. Accepted Make: Netgear/Cisco/HP
Supply and fixing CAT-6 24 Port Enhanced Modular type Patch Panel for interconnecting servers and clients, including termination charges. Accepted Make: Amp/Molex/Legrand/Honeywell
Repair and minatanance of faulty IO boxes, damaged RJ45 jack with replacement of new RJ45 jack for inter connection of nodes and switches, including termination charges and testing of new node points and making permanent labeling on the I/O box and on the patch panel. Accepted Make: Amp/Molex/Legrand/Honeywell *rate includes extra care handling, and labour charge,
Dismantling of existing 9 U rack, including installation of existing 24 port swichs (2 Nos) pach pannels (2 Nos), Network Terminating Unit, Power strip etc into the new 12U Rack. *rate includes extra care handling, and labour charges.
Supply and Fixing 19" 12U Wall Mount Rack for switches with cable manager and hardware mounting kit, necessary power strip Accepted Make:Valark/Netrack/HCL
Supply and fixing CAT-6 Information Outlet with spring shutter front access for inter connection of nodes and switches, including termination charges. Testing of new node points and making permanent labeling on the I/O box and on the patch panel. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply and Installation of Wi-Fi Access Points :- Indoor- Dual Band - Dual concurrent radio controller based thin access point with smoke detector appearance- Two (WAN/LAN) 10/100/1000BASE-T Gigabit Ethernet (RJ-45) ports 2x2 with 2 streams of data (2.4 Ghz and 5 Ghz), Multi -User MIMO, WiFi Protected Access (WPA, WPA2), PoE power option with virtual controller software and should be supplied with connecting CAT 6 patch cords, and should be properly fixed as per site requirement, other accessories including AC power adaptor, Wall mounting Kit, etc. Warranty: 3 years onsite. Accepted Make: Netgear/Cisco/HP
Supply, laying, testing, certification and documentation of CAT 6, 1Mtr standard factory crimped patch cord. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply, laying, testing, certification and documentation of CAT 6, 2Mtr standard factory crimped patch cord. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply, laying, certification and documentation of CAT-6, 4 pair UTP cable through the existing conduit / casing and capping as required. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply and fixing of 20 mm PVC conduits/ casing and capping with specials confirming to ISI standard on surface using suitable size fixtures spacing not exceeding 50 cm including making good the damage colour washing etc as required. Preferred make: Toms/Balco/Espee
Supply and fixing of 25 mm PVC conduits/ casing and capping with specials confirming to ISI standard on surface using suitable size fixtures spacing not exceeding 50 cm including making good the damage colour washing etc as required. Preferred make: Toms/Balco/Espee
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Accessories including External Angle 90°,Flat Angle 90°/TEE,Internal Angle 90°, Internal Coupler,Flat cross,End Cap,Flanged Coupler, Joint cover,Cable Retainer,Wall plate for internal angle etc. Preferred Make: MK/OBO/Legrand
Testing, Commisionning, labeling and Fine tunning of the entire Network system
Part II:Installation of Local Area Network system in Principal Agriculture Office (Annex) Kottayam. Supply,Installation,Testing and Commissioning of Layer 2 manageable 24 port Ethernet Switch with 10/100/1000 ports and 2 Gig SFP and Life time warranty. Accepted Make: Netgear/Cisco/HP
Supply and fixing CAT-6 24 Port Enhanced Modular type Patch Panel for interconnecting servers and clients, including termination charges. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply, Installation, Testing and Commissioning of Optical Transceiver, eSFP, GE, Single-mode Module suitable for the above switch with necessary LC/UPC pigtails, LIU box and including Splice Tray and Cable spool and termination as required. Accepted Make: Netgear/Syrotech/Goip/DNC
Supply and installation of SC-LC 3Mtr SM Fiber duplex patch Cord Accepted Make: Norden/DNC
Supply and Fixing 19" 9U Wall Mount Rack for switches with cable manager and hardware mounting kit Accepted Make: Valark/Netrack/HCL
Supply and fixing CAT-6 Information Outlet with spring shutter front access for inter connection of nodes and switches, including termination charges. Testing of new node points and making permanent labeling on the I/O box and on the patch panel. Accepted Make:Amp/Molex/Legrand/Honeywell
Supply, laying, testing, certification and documentation of CAT 6, 1Mtr standard factory crimped patch cord. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply, laying, testing, certification and documentation of CAT 6, 3Mtr standard factory crimped patch cord. Accepted Make:Amp/Molex/Legrand/Honeywell
Supply, laying, certification and documentation of CAT-6, 4 pair UTP cable through the existing conduit / casing and capping as required. Accepted Make:Amp/Molex/Legrand/Honeywell
Supply and fixing of 25 mm PVC conduits/ casing and capping with specials confirming to ISI standard on surface using suitable size fixtures spacing not exceeding 50 cm including making good the damage colour washing etc as required. Preferred make: Toms/Balco/Espee
Supply and Drawing of 6 Core single mode Low Water Peak Outside plant (OSP) OFC having LSZH sheath, conforming to ITU-T G.655, IEC 60794-1 : 2001, IS 13882 (Part 1/Sec 1) : 1999 etc. Accepted Make: Amp/Molex/Legrand/Honeywell
Supply and fixing of 20 mm PVC conduits/ casing and capping with specials confirming to ISI standard on surface using suitable size fixtures spacing not exceeding 50 cm including making good the damage colour washing etc as required. Preferred make: Toms/Balco/Espee
Supply and configuration of 1 KVA UPS with minimum 168 VAH. battery 1 Year OEM Warranty for UPS and 3 year for batteries. Accepted make:Numeric/Igatech/Hykon/ V Guard
Demolishing of concrete floor having 24x.05x.05m(LxBxH) size for laying 25mm PVC conduit including recondtioning of the floor with ceramic tile/ concrete as required
Avalon systems & services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .