Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-Finance H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | L1 | Accepted-Finance accepted being L1 | |
| 2 | L2₹21.4 L+₹4.7 L (28.3%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical CHANDIGARH 160009 | CHANDIGARH | CHANDIGARH | 160009 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹33,050
Closing Date
25 Mar 2021, 6:00 pmClosed
Executive Engineer, Electrical Division, HP.PWD M
Executive Engineer, Electrical Division, HP.PWD Mandi
Construction of Combined Office Building at Nerchowk, District Mandi HP SH Supply, Installation, Testing and Commissioning of Fire Alarm and Public addressable system therein
2021_PWD_45522_1
PW/MED/TA/NIT/ e-notice/20-21-7416-22 dt 01.03.21
Open Tender
Electrical Works
Item Rate
365 days
Nerchowk
Please refer to bid document
11 documents required · 11 mandatory
₹500
Executive Engineer, Electrical Division, HP.PWD M
₹33,050
12 May 2021
15 Mar 2021
26 Mar 2021
15 Mar 2021
25 Mar 2021
15 Mar 2021
Amount
Supply installation and Commissioning of UL 864 Listed and FM approved 10th edition 32 bit 2 Loops Analog addressable Fire Alarm System having the total panel capacity of 125 devices [Detector or device any combination]in each loop. The panel shall have a backlit 2"-x-4.3/4" backlit LCD Screen and the four way navigation push button at the top of the FACP. The panel shall have the capacity of strong up to 5000 events.The panel shall have multiple levels of password protection, automatic environmentalbe compensation for smoke detectors, Degrade mode operation, Polarity-insensitive detection circuits.support single-person Walk test, connectivity to aleased- line/city tie module. The panel shall disconnect back up, battery on the addressable FACP when its voltage drop below 19 VDC . The panel shall have a built in power supply of 170 Watts and battery charger. Battery chrger shall be able to charge the system batteries up to 33 AH .The panel shall have 240 V AC POWER SUPPLY, 24V SMF BATTERIES SUFFICIENT FOR 24 HOURS IN STANDBY AND 30 MINUTES IN ALARM COMPLETE AS PER SPECIFICATION. The panel shall have the capacity of connecting additional 15 panels or network terminals with redundancy in the network . The panel shall have the capacity of connecting maxinum 8 remote terminals or 8 remote display. The panel shall be approved by UL 864 10 th Edition listed ULC,FM,CSFM And NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. MAKE:- Siemens, Cerberus, Honeywell Notifier, Bosch.
Supply Installation and Commissioning of UL and FM approved repeater Panel. The Panel shall be able to give location of all fire and fault and isolation conditions of addressable units of main fire alarm panel via the address codes and also having remote- system - control capabilties. The panel shall have a 160 characters baklit LCD screen. Panel will show all details of above panels, complete the work upto the entire satisfaction of Engineer In Charge. MAKE:- Siemens, Cerberus, Honeywell Notifier, Bosch.
Supply Installation and Commissioning of UL and FM approved intelligent Addressable Multicriteria Detector having responsiveness of photoelectric,thermal [Rate of rise and fixed ] Builts in isolation [In built fault isolator in detector]ionization technology and false alarm resistance along with standard base. The detector shall be Polarity insensitive dust resistant photoelectric chamber, Automatic environment compensation ,Field programmable as rate of rise or fixed temprature. The detector shall have Tri-Color detector-Status light emitting diode [LED] with 360 degree view. The detector shall be approved by UL,ULC,FM,CSFM and NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. MAKE:- Siemens, Cerberus, Honeywell Notifier, Bosch.
Supply Installation and Commissining of UL Listed and FM Approved single action Manual Pull Station MCP shall be Built in isolation polarity insensitive, shock and vibration resistant,inbuilt isolator MCP shall be approved by UL,ULC,FM,CSFM and NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. MAKE:- Siemens, Cerberus, Honeywell Notifier, Bosch.
Supply Installation and Commissining of UL Listed and FM Approved intelligent Addressable Out put with one input module with Built in isolation having facility to activate sounders,AHU Tripping etc. Module shall be polarity insensitive, inbuilt isolator approved by UL,ULC,FM,CSFM and NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. MAKE:- Siemens, Cerberus, Honeywell Notifier, Bosch.
Supply of UL Listed and FM approved Line Isolator for isolating the section of Circuit incase of Short in the Addressable Loop wiring complete in all respect. MAKE:- Siemens, Cerberus, Honeywell Notifier, Bosch.
Supply Installation and Commissining of IEC60849 approved Glow Type EXIT/Stair/Emergency Exit Sign Board as finalized by Engineer in charge on both side showing marking [Runing Man,Arrow and Exist] and hanged with the ceiling with chain and faster complete the work up to the entire satisfaction of Engineerr in Charge. Make PES / HEINRICH / OMEX / COOPER / AGNI /Falcon.
Supply and Erection of PVC Insulated Two core FR Copper conductor cable ISI Marked in PVC Pipe recess/ Surface complete in all respect Make Finolex/Polycab/Plaza
Supply Installation and Commissining of Universal Power supply 24 V/5A shall be operated at 100-240 V AC, Out put Voltage 26 V to 29 V DC
Supply ,Installation, Testing,and Commoissioning of Voice Alarm Controller 8 - zone system controller : 8 Zone Paging System with pre-recorded messages for voice evacuation,Adopts LCD Screen for easy operation,Simple Integration with Fire Alarm Panels to activate EVAC / ALERT pre-recorded messages, Built in MP3 (USB) and FM /AM Fuctions, Built in Loud speaker for performing broadcast monitoring, with special monitoring volume control,1 line input, 1 microphone input, provides mix and emergency paging output modes, Provides 8 broadcast zone output function, the peak power of each zone is 400 W, and the total power of the all 8 zones is 1000W , 1 alarm aqctivation input. Make : Honeywell / JBL / Marten Audio.
Supply ,Installation, Testing,and Commoissioning Of 480 watts Power Amplifier : 100 V, 70V and 4- 16 Ohms transformer isoplated, Combination XLR / RCA Line in and Line out, LED status indicators, speaker output short circuit protection,Frequency response 60 Hz~15 KHz ( +- 3dB ), S/N >80db. Make : Honeywell / JBL / Marten Audio.
Supply, Installation and Commissioning of wall mount / ceiling speaker with 6 watt operation Make : Honeywell / JBL / Marten Audio.
Supply, Installation and Commissioning of 2 core 1.5 sqmm speaker cable. Make Finolex/Polycab/Plaza
Supply and Erection of PVC Pipe 25 Mm dia ISI marked [Medium] recessed in wall/ceiling etc the cosrt of PVC Bends. Inspection bends Iron Hooks,Iron hooks and cement concrete etc complete in all respect in all respect upto the entire satisfaction of engineer in charge of work Make BEC / Diplast / Polyplast.
Supply Installation Testing and Commissioning of 12U Standard Rack to place all equipment Make Valrack,Comrack,HCL
TARUN FIRE SYSTEM
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .