EO
Nabadiganta Bhavan, Street No. 21, GN-20, Nabadiganta Industrial Township, Kolkata-700091
Constructional work to provide its safety security arrangement system at south side and construction of duct with manhole including improvement of entry exit of non-conductivity cables to facilitate security an safety system at Town Hall at Secto
2026_MAD_1017006_1
WBMAD/NDITA/118/2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
Percentage
45 days
NDITA Area
Please refer tender documents
6 documents required · 6 mandatory
₹0
₹2.3 L
28 Feb 2026
28 Feb 2026
27 Mar 2026
28 Feb 2026
24 Mar 2026
28 Feb 2026
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. a) Pakur Variety
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roof. (a) upto 150 mm. thick
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof
Construction of Bamboo fencing with setting of Bamboo post of 75mm dia. @ 1500mm C/C and 600mm below the ground by digging hole in all sorts of soil and subsequent though repacking the same and clean height 900 mm from the ground level including the cost of one coat coal tarring the embedded portion of the Bamboo and walling made of crushed bamboo or split bamboo or bamboo twigs(kanchis) as directed and tied with necessary stiffeners of split bamboo(in pair) made of 75 mm doia. fitted and fixed including coast of nailling and complete with 2(Two) coats of synthetic enamel paint over a coat of wooden primer. Analyzed Rate
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS-6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.)
Anti termite treatment to back filling of the masonry foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 7.5 Litres per sq. m. of the vertical surface of the substructure for each side of the foundation.. The work shall be carried out as per specification described in 6.2.2. of code IS-6313 (part -II) 1981. (Mode of measurment will be vertical area treated.)
Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurement will be per Sq.m of plan area of plinth treated.) Ref:- PWD(B)2017 Schl. Pg-5 I-10(c)
Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS-6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated)
M.S structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental changes such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural tubular members as specified in relevant IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. Therates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. iii) for trusses spanning above 20.00 m and up to 30 .00m Ref:- PWD(B)2017 Schl. Pg-100, I-2(iii)
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (a) 25 mm thick plaster
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. (b) 50 mm thick interlocking designer concrete paver block M-30 grade for non-traffic zone,buiding premises,garden,parks,domestic drive as per IS: 15658- 2006(over 20-30 mm medium sand bed on 200mm thk bound granular /granular base course including cost of sand for sand bed but excluding cost of base course & subgrade preparation.) (i) Grey
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including screening of aggregates and granular materials, premixing the material with water at OMC in Wet Mix Plant, carriage of mixed material by tipper to site, laying in uniform layers with Paver in Sub- base / Base course on well prepared surface and compacting with Vibratory Roller to achieve the desired density, including supply of all materials, machinery, fuel and lubricants, including incidental costs for lighting, guarding, barricading, making earthen bundh to protect the edges including cost of quality control complete as per Clause 406 of Specifications for Road & Bridge Works of MoRT&H (5th Revision) Analysis rate based on PWD(R)2018,P-249, It-4.12 & 11th Corrzondam.
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concrete M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for at least 3 days including cost and carriage of all materials complete.
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping until hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Hire and labour charges for shoring work (including necessary close plank walling, farming, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-Charge for foundation excavation (vertical surface are in contact with support earth is to be measured.) (This item should be executed on specific direction of the Engineer in Charge). (a) Dept upto 1.5 m.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL (a) ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. i) Ground floor
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. Area of each Granite slab > 0.6 upto 1.0 square metre. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) 150 mm
Supply, installation, testing & commissioning of 1/2.8" CMOS, 2 MP vandal proof Dome camera, H265 or better video compression 2.8mm - 13.5mm focal length motorized zoom vari focal lens, 50mtr illumination distance, triple stream resolution, 3D DNR noise reduction, P-Iris support on VIF interio perability, 120 db WDR, built in micro SD/SDHC/SDXC storage card (256 GB), 12V DC, power supply, POE, S/N ratio >56dB 0.005 [email protected] or better min illumination, F 1.5 or better aperture, Auto/mannual gain control, O°C - 60°C operating conditions, IP67 & IK10 ingress protection, CE, FCC, BIS, UL certifications, professional intelligent - camera support Trip wire, intrusion. Make : TYCO/BOSCH/AVIGILION/MOBOTIX/INFINOVA.
Supply, installation, testing & commissioning of 1/2.8" CMOS, 2 MP vandal proof IR HD Bullet camera, H265 or better video compression 2.8mm - 13.5mm focal length motorized zoom vari focal lens, 50mtr illumination distance, triple stream resolution, 3D DNR noise reduction, P-Iris support 120 db WDR, ONVIF interoperability, built in micro SD/SDHC/XDXC minimum support-256G, 12V DC/POE power supply, S/N ratio >56dB, 0.005 [email protected] min illumination, F 1.5 or better aperture, Auto/mannual gain control, O°C - 60°C operating conditions, camera support Trip wire professional intelligent, IP67 & IK10 ingress protection, CE, FCC, BIS, UL certifications. Make : TYCO/BOSCH/AVIGILION/MOBOTIX/INFINOVA. Ref:- Work Order. 9500000335 dtd. 20.01.2022 (Sl No: 20) of G.M.(Electrical) / W.B.HIDCO
Supply, installation, testing & commissioning of General surveillance video recording management server & storage system support for 30 days of recording of whole cameras intel i5 processor, 8 SATA support/each SATA should support 18 TB HDD, videos input/output-900mbps or better, 7x24 operation support windows 10 or Linux 22.4 operating system, 32 GB or better memory, 1+1 redundant power, 3HDMI or higher, CE,BIS,FCC,UL certifications. Make : TYCO/BOSCH/AVIGILION/MOBOTIX/INFINOVA.
Cost of channel license for video management software for three years
Supply, installation, testing & commissioning of 8TB surveillance grade SATA Enterprise HDD. Make : Seagate/Water Digital/Toshiba
Supply, installation,testing & commissioning of PC mounted work station with 10th Generation/latest generation intel core i7 processor, 32GB DDR4 RAM, Dedicated non shared quadro T400 4GB GDDR6 Graphics card, operating system latest windows 11 Pro 64 Bit pre-loaded. Storage 512GB SSD+1TB SATA, Ports & connectors, 180W internal power supply upto 90% efficiency, active PFC. Make: Dell/Lenovo/HP
Supply, installation,testing & commissioning of layer -3 Fully managed switch having 24X10/100/1000 baseT PoE+ Copper Ports with 4 X Combo 1G SFP Slots & 4X10G SFP+Slots. Make: CISCO/Netgear/HP/Allied Telesis Ref: Earlier offered rate of M/s WEBEL for Town Hall Building vide offer no: DM/NWD/NDITA-NW/22-23/002 (Sl No: Active & Passive components-3) dtd. 27.03.2023
Supply, installation,testing & commissioning of 24 Port rack mount LIU Fully loaded with single Mode SC Adapters. Make: Molex/Panduit/Belden/Comscope/Siwmon
Supply, installation,testing & commissioning of 55" Full HD resolution LED with 3 X HDMI/Mini DP input inbuilt android, 2GB DDR3 RAM, 16GB ROM, mini 20W inbuilt speaker, BIS certification, min 400 Nits brightness, min 2.4 Ghz inbuilt WI-FI wall display unit including wall Petractable brackets, necessary cable, connectors as per direction of EIC. Make: LG/Samsung/Sony/Panasonic.
Supply, installation & commissioning of 9U (550mm width x 600mm depth) wall mount networking Rack with standard accessories with 2(two) nos. fan. Make : Tata/Net Rack/ValRack
Supply, installation & commissioning of 1GB single Mode Duplex Patch/SFP module. Make: CISCO/Netgear/HP/Allied Telesis
Supply, installation & commissioning of SC-LC FO Duplex Patch cord (3mtr. Length) Make: Molex/Panduit/Belden/Comscope/Siemon
Supply, installation & commissioning of of CAT RJ45 connectors/clip Make: ISI Standard reputed brand
Supply & drawing of CAT6 cable Make: Molex/Panduit/Belden/Comscope/Siemon
Supply, installation & commissioning of 3 core, 1.5 sqmm non armoured 100DV grade, FR PVC insulated & sheathed flexible unarmoured power copper cable. Make: havells/Finolex or any PWD approved brand.
Supply & installation/ drawing of 25mm dia hard PVC pipe/conduit or 3/4"/1.0" PVC casing with necessary accessories, supplying necessary saddle etc. as required.
Add GST@18% on Sl. No. 1 to 41
Add labour cess @1% on Sl. No. 1 to 42
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.57 MB
BOQ_2498708.xls
BOQ • 0.36 MB
FORM1C.pdf
Tender Documents • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .