Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance 0 GHAIR SALAWAT KHAN RAMPUR RAMPUR RAMPUR RAMPUR UTTAR PRADESH 244901 | RAMPUR | UTTAR PRADESH | 244901 | L1 | Accepted-Finance L1 | |
| 2 | L2₹2.1 L+₹10,498 (5.28%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹2.1 L+₹12,477 (6.28%)Accepted-Finance | L3 | Accepted-Finance L3 |
Tender Value
₹2.2 L
EMD Value
₹4,000
Closing Date
5 Apr 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, Rampur
Office of the Superintending Engineer, EDC, Rampur
60/2022-23(EDCR) Construction of line for Separate industrial feeder under EDD-I, Rampur and Construction of new line to eliminate overloading 100 KVA TF under EDD-Milak, Rampur
2023_PVVNL_781237_2
60/2022-23(EDCR)
Open Tender
Electrical Works
Lump-sum
45 days
Office of the Superintending Engineer, EDC
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
SE, EDC, Rampur
₹4,000
19 Aug 2023
28 Mar 2023
5 Apr 2023
28 Mar 2023
5 Apr 2023
28 Mar 2023
Amount
Carriage of the following material from Store Centre, Rampur to work site including loading & unloading.
11 Mtr Long ST pole
8.5 PCC Pole
11/0.4 Kv 25 KVA Transformer
11 KV Cable 3x185 Sqmm
11 KV Cable jointing kit 3x185 sqmm
ACSR Weasel Conductor
ACSR Dog Conductor
Scrap ACSR Conductor old and used (from site to Store)
a) Single support Excavation of foundation Pit in size of 75x45cm having depth of 1/6th of the full length of the support(pole), providing and laying of stone pad (300x300x75 mm) in the Bottom of the pit. Erection of support(pole) complete with fixing of 11 KV V-type cross-Arms and other accessories by providing clamps made of MS flat of size 65x65xc6 mm with Nuts & Bolts, as per RESPO Norms.
8.5 Mtr long PCC pole
11 Mtr Long ST pole
b) Double Pole structure
8.5 Mtr long PCC pole
Grouting of support in CC 1:4:8(cement, sand & 40 mm. brick ballast) Grouting will be done in the block of size 45x45cmx1/6th of full length of the support upto ground level, 30 cm plinth above the ground level with CC 1:3:6 (cement, course sand and stone grit) with muffing. The work includes back filling and proper ramming etc. a) Single support
8.5 Mtr long PCC pole
11 Mtr Long ST pole
b) Double Pole structure
8.5 Mtr long PCC pole
Grouting of Stay Rods(20x1800)mm including all work of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:8(cement, sand, 40mm brick ballast) including back filling of soil and proper ramming etc.
Earthing of support with MS Earth Rod of (20x2500)mm long including excavation of pit and driving MS Rod 3.0 M apart from support and 0.5 M below the ground level and connecting below the earth electrodes with the help of GI wire No. 8SWG and earthing lugs
Fixing, tightening and nozelling of stay wire with stay rod with the pole of required tension by providing stay clamps.
Fixing, tightening of Pin Insulator with Pin on pole as required.
Fixing, tightening of Disc Insulator with Pin on pole as required.
Laying, sagging, stringing and binding with jumpering etc of ACSR Weasel Conductor with Jumpering as per RESPO Norms and as per direction of Supervising Engineer.
Laying, sagging, stringing and binding with jumpering etc of ACSR Dog Conductor with Jumpering as per RESPO Norms and as per direction of Supervising Engineer.
Laying, sagging, stringing and binding with jumpering etc of 11 KV Cable 3x185 Sqmm with the help of Cable jointing Kit 3x185 sqmm as required as per RESPO Norms and as per direction of Supervising Engineer.
Installation of 11/0.4 KV 25 KVA Transformer including earthing and making connection etc.
Providing and fixing of Danger board with clampas per direction of Supervising Engineer.
Digging of trench and laying 11 kv cable under ground at road crossing as per direction of Supervising Engineer.
Providing and fixing GI Pipe 6" Dia for underground 11 KV cable as per direction of Supervising Engineer
Providing and fixing Clamps for GI Pipe 6" Dia
Providing and fixing Barbed Wire
Providing and fixing F Bracket with bolts and nuts
Providing and fixing of clamp holding X-Arm with Nut and bolts
Providing and fixing of clamp with Nut and bolts
S A TRADERS
Krishna Electricals
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .