| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹41.3 L+₹4.3 L (11.7%)Rejected-Finance 174 G 1 NETAJI COLONY BARANAGAR KOL 700090 | BARANAGAR | KOLKATA | WEST BENGAL | 700090 | L2 | Rejected-Finance Higher Quoted Rate | |
| 3 | L3₹41.9 L+₹4.9 L (13.2%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L3 | Rejected-Finance Higher Quoted Rate | |
| 4 | L4₹43.7 L+₹6.7 L (18.1%)Rejected-Finance 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L4 | Rejected-Finance Highest Quoted Rate | |
| 5 | Rejected-Technical 119 MANAHAR PUKUR ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | - | Rejected-Technical As per Technical Evaluation Summary Documents. |
Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
12 Jul 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, PWD, Kolkata Electrical Circle
P-16, India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Balance work of State Guest House on Plot No- IID by 41 and Premises no-04-4444, New Town, Kolkata-External electrical works including compound light, EI of Lift, EI of AC supply and installation of fittings and fixtures.
2022_WBPWD_386488_1
PWD/SE/KEC/NIT-09/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
New Town, Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹95,000
Office of the SE, PWD, Kolkata Electrical Circle
17 Nov 2022
22 Jun 2022
14 Jul 2022
22 Jun 2022
12 Jul 2022
6 Jul 2022
4 Jul 2022
Amount
PART A (Panel, Cable, Internal Wiring, Light Fitting and Allied Works) Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (Make- Havells/RR Kable/Finolex/Polycab/Gloster) [Schedule Page E 9, Item No C 1] (i) 3 x 22/0.3 (1.5 sqmm) (for point wiring of Light, Ceiling Fan, Exhaust Fan, SB Circuit etc)
Do----Do----Do (ii) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (for power point & high CFM exhaust fan wiring)
Do----Do----Do (iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For electric car charger point)
Do----Do----Do (iv) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (UPS DB to SPN, HTPN DB to SPN DBs, VTPN to Overhead pump)
Do----Do----Do (v) 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC ( VTPN to AC outdoor unit & VTPN to Kitchen HTPN DB)
Do----Do----Do (vi) 4 x 84/0.4 (10 sqmm) + 2 x 84/0.3 (6 sqmm) ECC (VTPN to HTPN DB which will be used for Pantry, conference & resturent)
Do----Do----Do (vii) 4 x 126/0.4 (16 sqmm) + 2 x 80/0.4 (10 sqmm) ECC (VTPN to AC Outdoor unit of Banquet hall and VTPN to Guest room HTPNs)
Do----Do----Do (viii) 2 x 80/0.4 (10 sqmm) + 1 x 80/0.3 (6 sqmm) ECC (VTPN to SPN DB which will be used for Admin room, lift lobby, security room etc at Ground floor)
Do----Do----Do (ix)2 x 126/0.4 (16 sqmm) + 1 x 80/0.4 (10 sqmm) ECC (VTPN to SPN DB which will be used for 1st floor utility rooms)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (For Kitchen Single phase equipments) (Make- Legrand/ ABB/ L & T)
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (For Kitchen 3 phase equipments) (Make- Legrand/ ABB/ L & T)
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. (For Kitchen area 3 phase equipment) (Make- Legrand/ ABB/ L & T)
Supplying and fixing following moduler Switch / Socket ,on the existing modular plate & switch box including connections but excluding modular plate as required. (Make- Legrand , Myrius/ Schneider, OPALE / Similar) (i) 6 A switch
Do----Do----Do (ii)16A Switch
Do----Do----Do (iii) 3 pin 6A socket
Do----Do----Do (iv) 6 pin 16A socket
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. [Schedule Page E 2, Item No 2b] 19 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. [Schedule Page E 2, Item No 4b] 25 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [PWD ELECTRICAL 2017 Page E 18 Item No. 10] (Make- Legrand , Myrius/ Schneider, OPALE / Similar)
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. (Make- Legrand , Myrius/ Schneider, OPALE / Similar) [PWD ELECTRICAL 2017 Page E 17 Item No. 1] (i) 4 Module (For Lighting, Power point etc.)
Do----Do----Do (ii) 6 Module (For Lighting,Power point etc.)
Do----Do----Do (iii) 8 Module (For Lighting,Power point etc.)
Do----Do----Do (iv) 12 Module (For Lighting,Power point etc.)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (As per model of switches)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [PWD ELECTRICAL 2017 Page E 16 Item No. 7] (i) 20mm size
Do----Do----Do (ii) 25mm size
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [PWD ELECTRICAL 2017 Page D 6, Item No 7] (Make- Legrand/ Siemens/ABB) (i) 6-32A SP MCB (For SPN DB Charging & UPS SPN DB Charging)
Do----Do----Do (ii) 40A SP MCB (For SPN DB Charging & Over Head Pump Power Supply)
Do----Do----Do (iii) 63A SP MCB (For Car Charging Point & Lift well power Point)
Do----Do----Do (iv) 6-32 A DP MCB (For SPN DB Incomer)
Do----Do----Do (v) 40A DP MCB (For SPN DB Incomer)
Do----Do----Do (vi) 63A DP MCB (For SPN DB Incomer)
Do----Do----Do (vii) 6-32A TP MCB (For Kitchen DB)
Do----Do----Do (viii) 40A TP MCB (For TPN Power Supply, Lift Power & PHE Panel)
Do----Do----Do (ix) 63A TP MCB (For UPS 3-Phase Power Supply & TPN Power Supply)
Do----Do----Do (x) 6-32A FP MCB
Do----Do----Do (xi) 40A FP MCB (For AC's Outdoor unit Power Supply)
Do----Do----Do (xii) 63A FP MCB (For AC's Outdoor unit Power Supply)
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. [PWD ELECTRICAL 2017 Page D 8 Item No. 10] (Make: Lagrand / ABB/ Siemens) (i) 200 Amp 4P MCCB (Incoming MCCB of VTPN)
Do----Do----Do (ii) 100 Amp 4P MCCB (Incoming MCCB of VTPN)
Do----Do----Do (iii) 125 Amp 4P MCCB (Incoming MCCB of VTPN)
Supplying and fixing double door 4 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [PWD ELECTRICAL 2017 Page D 11] (Make Lagrand / ABB / Siemens) Incoming- 100 Amp MCCB Outgoing- 63 Amp TP MCB (It will be used for all type of power points of this building)
Supplying and fixing double door 4 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [PWD ELECTRICAL 2017 Page D 11] (Make Lagrand/ ABB/ Siemens) Incoming- 63 Amp 4P MCCB Outgoing- 40 Amp TP MCB (It will used for utility power such as Lift & pump)
Supplying and fixing following Pop-up type flush-mounting boxes for furniture complete with connections, testing and commissioning etc. as required. (Make- Legrand) (For conference room, guest rooms etc) (i) 1 nos 6A Switch & socket ,Blank plate as required within 4 Module
Do----Do----Do (ii) 1 nos HDMI,USB charger -2 nos,DATA- 2 Nos complete with connection as required within 2x4 Module (for Admin, Office etc.)
Do----Do----Do (iii) 1 nos 16A Switch & socket ,Blank plate as required within 4 Module
Supplying and fixing Universal socket with Modular box,Cover plate complete with connections, testing and commissioning etc. as required. (a) 1 nos 6A Switch & Universal socket with interconnection complete(Modular box,cover plate,switch & socket) as required (for Banquet, Guest room, Admin etc)
Supply of following sizes 1.1 KV Grade Aluminium Armoured conductor, XLPE insulated, PVC inner sheathed, PVC type ST-2 outer sheathed and Galvanized wire/flat strip armoured LT Power Cables as per IS 7098 Part-I (latest edition) (Make-Havells/Gloster/Polycab/Currency) (i) 2 run 4 core 120 sq. mm (From LT Bulk Source to Main Panel)
Do----Do----Do (ii) 4 core 120 sq. mm (From LT Panel to 200Amp 8way VTPN DB)
Do----Do----Do (iii) 4 core 95 sq. mm (From LT Panel to fire cum panel)
Do----Do----Do (iv) 4 core 50 sq. mm (From LT Panel to 100Amp 4 Way VTPN DB & 125Amp 4 Way VTPN DB)
Do----Do----Do (v) 4 core 25 sq. mm (From VTPN to Water Pump panel, and VTPN to 2 nos Lifts)
Do----Do----Do (vi) 4 core 10 sq mm (For Compound illumination)
Supplying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor Armoured cable as per IS 7098(Part I ,1988).Laying of this cable should be laid direct in groundincluding excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (Make-Havells/Gloster/Polycab/Currency) (i) 4 core 6 sq. mm (For Ac ODU Units)
Supplying and fixing compression type gland complete with brass gland,brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: [PWD ELECTRICAL 2017 Page F 4.] (i) 4 core 120 sq. mm
Do----Do----Do (ii) 4 core 95 sq. Mm
Do----Do----Do (iii) 4 core 50 sq. Mm
Do----Do----Do (v) 4 core 25 sq. mm
Do----Do----Do (vi) 4 core 10 sq mm
Finishing the end of following XLPE/PVC armoured cable by crimping method incl. supplying and fixing solderless socket(Dowels make).tapes,anticorrosive paste & Jointing materials: PWD ELECTRICAL 2017 Page F5. (i) 4 core 120 sq. Mm
Do----Do----Do (ii) 4 core 95 sq. mm
Do----Do----Do (iii) 4 core 50 sq. mm
Do----Do----Do (v) 4 core 25 sq. mm
Do----Do----Do (vi) 4 core 10 sq mm
Laying of cable as below,on existing Cable Tray and binding with suitable size GI wire. PWD ELECTRICAL 2017 Page F3 Item No. 5 (i) Upto 50 sqmm (For different size of cables which will be draw from Panel to VTPN)
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Above 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. incl. Al painting of MS support. PWD ELECTRICAL 2017 Page D14 Item No. 34 With out angle iron support 150x50x1.25mm (18SWG)
Do----Do----Do With 25x25x3mm angle iron support 300x50x1.25mm (18SWG)
Supply of Decorative Ceiling fan anti dust coating (1200mm sweep) complete with accessories as required. (Make Havells-Enticer / Crompton High Speed Markle Prime / Orient Electric Kiara Shine). Excluding Fixing (at RECEPTION, SECURITY ROOM,GUEST ROOM ETC)
Supply of Heavy Duty Exhaust fan (450 mm sweep, 1400R.P.M) complete with accessories as required. (Make: EPC Heavy duty/Havells-Turbo force/ Crompton/USHA) (For Kitchen)
Supply of Heavy Duty Exhaust fan (300 mm sweep, 1400R.P.M) complete with accessories as required. (Make- EPC Heavy duty / Havells-Turbo force /Crompton/USHA/EPC) (For bathroom)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [PWD ELECTRICAL 2017 Page C 3 Item no 21a.]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter including Supply & Fixing louver shutter on wall with necessary Bolts & Nuts (for Al.) as per GS: PWD ELECTRICAL 2017 Page C 4 Item no 28 d. (i) 45 cm (18")
Do----Do----Do (ii) 30 cm(12")
Supply & installation of spot light beam angel not more than 36° & vertical tilt 270° or more, Wattage : 3 Watt, CCT : 3000K. Make: (Crompton CDR-210-03-30-SL-MWH/Philips Equivalent/Wipro Equivalent/Havells Equivalent/ Bajaj Equivalent)
Supply & installation of Spot Light beam angel not more than 36° & vertical tilt 270° or more, Wattage : 6/7 Watt, CCT : 3000K. Make: (Crompton CDR-211-06-30-SL-MWH/ Bajaj BRDCSL 7W LED WW/ Philips Equivalent/Wipro Equivalent/Havells Equivalent)
Supply & installation of Spot Light beam angel not more than 36° & vertical tilt 270° or more, Wattage : 12 Watt, CCT : 3000K. Make: (Crompton CDR-212-12-30-SL-MWH/Bajaj BRDCSL 12W LED WW/ Philips Equivalent/Wipro Equivalent/Havells Equivalent)
Supply & installation of Spot Light, Wattage : 18 Watt, CCT : 3000K. (Philips, Cat- COB Pro/Wipro, Cat- 3710/Crompton/Havells/ Bajaj BRDCSL 18W LED WW)
Supply & installation of SURFACE DOWN LIGHTER (Round/Squre), Wattage : 24Watt, CCT : 3000K/4000K. Make: (Philips/Wipro, EOS Square, Cat- LD66S-301-XX-65-SM/Crompton Eqivalent / Bajaj BPSLR Surface 24W LED NW RD SD)
Supply & installation of RECESSED DOWN LIGHTER (Round/Squre) , Wattage : 12Watt, CCT : 3000K/4000K. Make: (Philips-Cat No. SN250CLED125-6500 PSU WH/Wipro Equivalent, IrisNeo Nextgen, Cat LD95-141-XXX-65-G1/Crompton LCDEP-12-WW/ Bajaj BPSLR 12W LED NW RD SD)
Supply & installation of 300MM HEIGHT GLASS WITH BRASS FINISHED WALL LIGHT , dimmable , Wattage : 15Watt, CCT : 3000K. Make: (Philips, Model-Oriel Next, cat- 34142/Wipro Equivalent/Crompton Equivalent/Havells Equivalent)
Supply & installation of 600MM GLASS WITH Chrome/Brash finished WALL LIGHT, non-dimmable , Wattage : 25Watt, CCT : 3000K. (Philips, Model- Aquila LED Wall Light, Cat- 58158/Wipro Equivalent/Crompton Equivalent/Havells Equivalent)
Supply & installation of FOOT LAMP, Wattage : 3/4/5Watt, CCT : 3000K. Make: (Philips, Cat-58164/Wipro Equivalent/Crompton Equivalent/Havells Equivalent/ Bajaj 5w LED WW PRO)
Supply & installation of WARDDROBE LIGHT (under cabinet LED) 900MM, non-dimmable , Wattage : 12Watt, CCT : 3000K. Make: (HYBEC/ Philips Equivalent/Wipro Equivalent/Crompton Equivalent/Havells Equivalent/ Bajaj Equivalent)
Supply & Installation of TABLE LAMP WITH ARM, non-dimmable , Wattage : 10Watt, CCT : 3000K. Make: (Philips, Hint Table Lamp, Cat- 31438/Wipro Equivalent/Crompton Equivalent/Havells Equivalent)
Supply & fixing of of 36 watt system wattage 5700 K Colour Temperature, Cool Day Light Colour, recessed mounted IP 20 LED 2ft X 2ft luminaries having > 3600 lm system output. Luminary shall be made up of CRCA epoxy polyester powder coated housing. Luminaries shall have optical grade High Efficiency Translucent Optical component for very high efficiency with minimum glare. Driver output voltage shall be less than SELV limits for safe DC operation and maintenance. The Driver should be fully designed and manufacture in India. (Make- Wipro Equivalent, Elate- CRCO10R038HP57GL1/ Crompton Equivalent / Philips Equivalent/ Bajaj BZRSQL 36W LED GX)).
Electrical Panel: Supplying, installation, testing & commissioning of cubical type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates including cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 2500 Amp capacity extensible type TPN copper bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC busbar supports, with short circuit withstand capacity of 50 KA for 1 Sec., panel should be fabricated with 50mm x 50mm x 6 mm angle structure and the base should be fabricated with 40mm x 6 mm flat bars. Bottom base channel of the MS section is not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, the entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from the main bus bar to switch gears with the required size of Al. bus bars and control wiring with PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two halves, i/c providing the following switch gears :- (Make- L&T/Siemens /Schneider) (A) Incoming Arrangement: Supply & Installation of 415 V 4P 36KA 400 A MCCB with thermal release fixed type suitable for isolation with extended rotary handle and on/off/trip contact- 2 Nos. (1 nos for Incoming arrangement & 1 no for future DG source) ICS=100% ICU. Supply & Installation of 415V 4 pole 400 Amp on load changeover switch-1 no. (B) Bus Section: 500 V 600 A electrolyte grade tinned copper bus bar with vertical section of size 1 nos 100 mm x 10 mm for Phase RYB, & 1 Nos 50x10 mm for neutral bars & 50x 5 mm Copper Bar for earth. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. (C) Outgoing arrangement: (i) Supply & Installation of 415 V 4P 36KA 200 A MCCB with thermal release fixed type suitable for isolation with extended rotary handle and on/off/trip contact- 2 Nos. (1 no for AC & 1 no. spare) ICS=100% ICU (ii) Supply & Installation of 415 V 4P 36KA 160 A MCCB with thermal release fixed type suitable for isolation with extended rotary handle and on/off/trip contact- 1 No. (for fire pump panel) (iii) Supply & Installation of 415 V 4P 36KA 125 A MCCB with thermal release fixed type suitable for isolation with extended rotary handle and on/off/trip contact- 1 Nos. ICS=100% ICU (iv) Supply & Installation of 415 V 4P 36KA 100 A MCCB with thermal release fixed type suitable for isolation with extended rotary handle and on/off/trip contact- 3 Nos. (2 nos for VTPN DB & 1 no for spare) ICS=100% ICU (v) Spare Chamber for future use suitable for fixing upto 200Amp MCCB-2 nos.
PART- B (EI Work for VRF AC Machine & Ventilation System) Supplying and Fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make Siemens/ABB/Legrand) (i) 40A FP MCB ( For 12HP & 10 HP Outdoor Units)
Do----Do----Do (ii) 63A FP MCB (For 30 HP Outdoor unit)
Supply & fixing of 4 way PVC water proof (IP 65) 4P MCB encloser Box on wall (Make Legrand, Cat- 601996E/Similar) (For installation of 4 P MCB nearest to the outdoor units) PWD ELECTRICAL 2017 Page D 6, Item No 7
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For ductable/Cassette indoor units & 16 Nos Exhaust fan)
Supply & Fixing 240V, 25 A, 3 pin Modular type plug top with indicator (Legrand Myrius/OPALE/Crabtree/Schneider) & necy. PWD ELECTRICAL 2017 Page E 18, Item No9b Connections (For 18 nos VRF Indoor units and 2 nos Unitary type AC machines)
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand Myrius/OPALE/Crabtree/Schneider) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. PWD ELECTRICAL 2017 Page E 17, Item No 5b. (For 2 nos. unitary type AC machine)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius/OPALE/Crabtree/Schneider), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. PWD ELECTRICAL 2017 Page E 17, Item No 5b.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/RR) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC. PWD ELECTRICAL 2017 Page E 14, Item No 1
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC. PWD ELECTRICAL 2017 Page E 5, Item No 2
Part C: EI For 2 nos Lift: Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB),having a sensitivity current 300 mA in a SS MCB Encloser complete with connections, testing and commissioning etc. as required. (i) 40A FP MCB (ii) 300 mA RCCB (for Lift)
Supplying and fixing 2 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment with 16Amp DP MCB. (Make: Legrand / ABB / Siemens) PWD ELECTRICAL 2017 Page D- 9, D-6
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Legrand Myrius/OPALE/Crabtree/Schneider) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For shaft power points) PWD ELECTRICAL 2017 Page E 18, Item No9b.
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 9 watt LED lamp complete set. PWD ELECTRICAL 2017 Page D 13, Item No 23
S & Fixing fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit with L type MS Clamp as per GS. and connecting the length of PVC insulated wire and painting etc. with Supply, Fixing of 1 no LED tube 18 watt 2100 lumen [Crompton DIJB12LT8-20, LT8-18 865 (3)/Philips TMC 501 P 1xT-LED 22W P3241, MAS LED Tube 18W 2100LM 865 T8 (VE)] as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. (Make: Philips-Cat No- TMC 501-P1 X T- LED 22 Watt P3241/Bajaj/Wipro)(For lift head room)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. PWD ELECTRICAL 2017 Page J1
Excavation of soft soil for installation of Earth Electrode and filling & ramming. PWD ELECTRICAL 2017Pg.- G1,1a
Earthing with 50 mm dia GI pipe(By TATA-Medium GI) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. PWD ELECTRICAL 2017 Pg.- G1,2a
For providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe (2 nos. for each lift) PWD ELECTRICAL 2017 Pg.- G2,3a
S & drawing of 4 x 8 SWG G.I. wire from earth busbar on ground floor to lift well top busbar as per direction of the EIC. (For 2 No of lifts) PWD ELECTRICAL 2017 Pg.G2,5,a,iii
S&F earth busbar of galvanized (Hot Dip MS flat 40 mm x 6 mm of 0.5 mtr length on wall incl clearance 6 mm from wall incl. providing drilled 8 nos holes on the busbar complete with G.I. bolts nuts etc as per GS. PWD ELECTRICAL 2017 Pg.-G2,4,b
PART D: Compound Lighting System: Supplying and installation of GARDEN POLE LIGHT- (4M HIGH) : 1 X 36W LED WW,CCT : 3000K lumen effeciency ≥ 100 lm/watt with foundation nut bolt and accessories Make: Wipro Equivalent/Philips Equivalent/K-LITE [KP - ID - 4288 (Pole) + K - Lite ID - 5380 (light)] / Bajaj BGCPNP 45 LED WW (Light) + BJPL 014M ECO POLE (Pole)
Supply & Fixing of street light type 24 watt / 25 watt LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make: Philips, Cat- BRP042 P LED25 CW SLE S1 PSU GR P4210/Wipro/Crompton/ Bajaj ENXT P 25L WH PO PC SD)
Supplying and installation of SPIKE LIGHTS ,CCT : 3000K (to be fixed on 250x250 concrete block embedded in soil fill.) with all accessories as required. Make: Wipro/Philips, Cat- 31385/Crompton/ Bajaj BGSBL9W LED WW)
Supplying and installation of LED STRIP LIGHT with driver( Colour Warm White) Make: Philips, Model- SKYCove 5M WW/Wipro/Crompton/ Bajaj NXT 25W PROFESSIONAL LED STRIP IP20 WW + Driver
Supply, Installation, Testing & Commissioning of thermoplastic cable junction boxes (IP-66) junction box with knock outs for cable entry & terminal included (upto 4 sq.mm cable/wire) . (Make Hensel/Sintex). (for area lighting as per site requirement)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (Make- TATA/JINDAL) (i) 65 mm dia PWD ELECTRICAL 2017 Pg.-F-16, item 11
Sypply and Installation of 3ltr, 3KW instant Gyser including plumbing & elctrical connection as required (Make - Havells/venus/Crompton/Racold)
Sypply and Installation of 10ltr, 2KW storage Gyser (BEE 5 star rated) including plumbing & elctrical connection as required (Make - Havells/venus/Crompton/Racold)
KANJILAL and SONS
Prava Enterprise
MAHESWAR ELECTRICAL INDUSTRIES
technical_755986.pdf
PDF • 0.08 MB
techsummary_755986.pdf
PDF • 0.05 MB
finance_755986.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.03 MB
finsummary_755986.pdf
PDF • 0.54 MB
AOC-NIT09-22-23.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .