Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance LAL BAZAR SRINAGAR SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹11.1 L
EMD Value
₹22,231
Closing Date
23 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE EP BSNL JAMMU
AS PER NIT
Provision of Electrical service connection for upper Shri Amarnath JI Yatra 2025 (SANJY 2025) sites
2025_BSNL_234210_1
05/CPPP/EE(EP)/SE (E)/BSNL/JMU/2025-26
Open Tender
Electrical Works
Item Rate
30 days
BALTAL
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
AO CASH O/O CGM BSNL JAMMU
₹22,231
Yes
26 May 2025
1 May 2025
26 May 2025
1 May 2025
23 May 2025
1 May 2025
Amount
Supplying, installation, testing and commissioning of Double door, weather proof, IP54 compliant, free standing, cubicle type Main Power Distribution Board fabricated out of 16 gauge CRCA sheet having compartmentalized design for housing various equipments, with Hut type Canopy top cover for snow / rain protection, suitable base frame made out of 50mm x 50mm x 5 mm angle iron and legs approx 1 mtr. height, having viewing windows for meters & indicators with safety mesh and acrylic cover with proper sealant (for snow/ rain protection) , 02 nos earth studs & painted with good quality powder coating paint of approved shade, sign writing, danger notice plate etc. complete with cartage upto motorable road i.e. Base camp Baltal/ Domail & thereafter head load i.e. manual cartage of Power Distribution Board (PDB) alongwith all accessories viz. Automatic Voltage regulator, Transformer Oil, Distribution Board etc. from Base Camp to individual SANJY-2025 site as mentioned below (Approximate head load distance also mentioned below), installation of PDB alongwith all accessories viz. Automatic Voltage regulator, Transformer Oil, Distribution Board etc. at respective sites by fixing the Angle Iron frame in ground by providing CC foundation as per site requirement including excavation etc. complete with testing and commissioning of PDB alongwith accessories at site and having following accessories installed in PDB at below mentioned sites :(BSNL Approved makes) i) 10-60 Amp., 1-phase ,Class 1.0, Base mounting type KWh Meter with LCD Display -01 no. ii) 100 amps, DP MCCB, 25KA -- 1 no. iii) 16/32 amps, DP MCB, C - Series -- 3 nos iv) 63 amps, DP MCB, C - Series -- 1 nos v) 100 amp. 415 Volts, Four Pole, open execution type Change over switch --01 no. vi) 10 KVA, Single Phase, 50 Hz. , On Load Stepless , Copper Wound , Oil Immersed , Naturally Cooled ,Continuous Duty Automatic Voltage Regulator Unit having Input Voltage Range :- 120 Volt To 280 Volt , Line To Neutral & Output Voltage :- 240 Volts + - 1% ( Line To Neutral ) Designed and Constructed confirming to IS : 9815 :Part-I/ 1994 , as per specifications attached & complete with following accessories :- a) 01 No. Single Phase On load Continuously Variable Voltage Copper Wound Auto Transformer of suitable rating alongwith primary & secondary windings wound on the Auto-Transformer & 01 No. motor as specified. b) First Filling Of High Quality Transformer Oil. c) LED display for input /output Voltage, current -- 01 Set. vii) 63 amp Double Pole, On Load, side handle type Changeover Switch in sheet steel enclosure -- 01 no. viii) Indication lamps -03 nos (For Mains supply incoming, DG supply incoming & outgoing supply indications) ix) 32 Amps, 3 pin metal Plug top & metal socket -- 01 set x) 20 Amps, 3 pin metal Plug top & metal socket -- 02 set
Railpathri (approx. 3 KM head load)
Bararimarg ( Approx. 6 KM head Load)
Lower Holy Cave ( approx. 10 Km head load)
Supplying, installation, testing and commissioning of Double door, weather proof, IP54 compliant, free standing, cubicle type Main Power Distribution Board fabricated out of 16 gauge CRCA sheet having compartmentalized design for housing various equipments, with Hut type Canopy top cover for snow / rain protection, suitable base frame made out of 50mm x 50mm x 5 mm angle iron and legs approx 1 mtr. height, having viewing windows for meters & indicators with safety mesh and acrylic cover with proper sealant (for snow/ rain protection) , 02 nos earth studs & painted with good quality powder coating paint of approved shade, sign writing, danger notice plate etc. complete with cartage upto motorable road i.e. Base camp Baltal/ Domail & thereafter head load i.e. manual cartage of Power Distribution Board (PDB) alongwith all accessories viz. Automatic Voltage regulator, Transformer Oil, Distribution Board etc. from Base Camp to individual SANJY-2025 site as mentioned below (Approximate head load distance also mentioned below), installation of PDB alongwith all accessories viz. Automatic Voltage regulator, Transformer Oil, Distribution Board etc. at respective sites by fixing the Angle Iron frame in ground by providing CC foundation as per site requirement including excavation etc. complete with testing and commissioning of PDB alongwith accessories at site and having following accessories installed in PDB at below mentioned sites :(BSNL Approved makes) i) 10-60 Amp., 1-phase ,Class 1.0, Base mounting type KWh Meter with LCD Display -01 no. ii) 125 amps, DP MCCB, 25KA -- 1 no. iii) 16/32 amps, DP MCB, C - Series -- 3 nos iv) 63 amps, DP MCB, C - Series -- 1 nos v) 100 amp. 415 Volts, Four Pole, open execution type Change over switch --01 no. vi) 15 KVA, Single Phase, 50 Hz. , On Load Stepless , Copper Wound , Oil Immersed , Naturally Cooled ,Continuous Duty Automatic Voltage Regulator Unit having Input Voltage Range :- 120 Volt To 280 Volt , Line To Neutral & Output Voltage :- 240 Volts + - 1% ( Line To Neutral ) Designed and Constructed confirming to IS : 9815 :Part-I/ 1994 , as per specifications attached & complete with following accessories :- a) 01 No. Single Phase On load Continuously Variable Voltage Copper Wound Auto Transformer of suitable rating alongwith primary & secondary windings wound on the Auto-Transformer & 01 No. motor as specified. b) First Filling Of High Quality Transformer Oil. c) LED display for input /output Voltage, current -- 01 Set. vii) 63 amp Double Pole, On Load, side handle type Changeover Switch in sheet steel enclosure -- 01 no. viii) Indication lamps -03 nos (For Mains supply incoming, DG supply incoming & outgoing supply indications) ix) 32 Amps, 3 pin metal Plug top & metal socket -- 01 set x) 20 Amps, 3 pin metal Plug top & metal socket -- 02 set
Sangam (Approx. 9 Km head load)
Upper Holy cave (Approx.14 Km head load)
Panjtarni-I ( Approx. 15 Km head load)
Panjtarni-II ( Approx. 15 Km head load)
Supplying and laying of multi stranded PVC insulated Aluminium Conductor Twin Flat sheathed 1.1 KV grade LT cable of 2 core 25 sq. mm Confirming to IS 694/1990 with latest amendments complete with cartage & head load upto SANJY 2025 upper sites, laying at site as per requirement ,complete with connections etc. as required.
Jaima Electricals (BID ID -854053)
AKHTAR ELECTRICALS (BID ID -850807)
SOWELL AGENCIES (BID ID -852613)
M.O.S ELECTRICALS (BID ID -852776)
M/S SHANDAR ENTERPRISES (BID ID -852939)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .