RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Advanced Bipolar And Ultrasonic Energy Generator ( 10 pieces ) Technical Specifications 1/9 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Performance Parameters System should have ultrasonic energy as well as Advance RF Energy/Bipolar energy device for cutting and tissue dissection and vessel sealing with a sinusoidal forced impedance output ` Yes * Mode of Provision of both Ultrasonic Energry and Radio Frequency energy Single generator unit Combining both Single generator unit Combining both The switch and control systems provided Single in case of single unit Single in case of single unit Type of activation available for operating ultrasonic energy and/or RF energy system as per requirement Both Hand Switch and Foot Switch Both Hand Switch and Foot Switch Should have the ability to change the power settings selections during the use Available Available Type of Display LCD LED
RequiredLCD Type of control Touch Screen Touch Screen Should have stand by mode to ensure safety Yes * System should'have onscreen graphical warning display system for generator overheating
Requiredgenerator software upgrade
Requiredhand piece errors and instrument errors Yes Yes
RequiredNo Consumable compatibility with surgery type allowing simultaneous cutting and coagulation of tissues Both open and Laproscopic Both open and Laproscopic 2/9 Should be compatible with integrated ultrasonic energy instruments which can simultaneously seal and transect vessels
Requiredlarge pedicles and vascular bundles with ultrasonic energy with system feedback Yes * The capacity of ultrasonic energy instruments for working with Up to and including 7 mm vessels Up to and including 7 mm vessels Should be compatible with integrated RF/bipolar instruments which can simultaneously seal and transect vessels
Requiredlarge pedicles and vascular bundles with RF energy with system feedback yes * The capacity of RF/Bipolar energy instruments for working with Upto and including 7 MM vessels Upto and including 7 MM vessels The frequency range of instruments ultrasonic device can power in KHZ 50-60 50-60 Nummber of power setting levels with power level display for ultrasonic energy instrument 5 5 Area of lateral thermal spread not to exceed 1 mm * Maximum shaft dimeter of ultrasonic instruments that can be connected 5mm 5mm Movement of shaft rotation for compatible energy consumables available during surgical procedures in degrees 360 degree 360 degree Total articulation ability (Left and 110 to 150 110 to 150 3/9 Right side of distal portion of shaft) for RF consumables during a laparoscopic surgery for enhanced flexibility and maneuverability Classifiction of System to provide adequate protection against electric shock Class 1 * Temperature control feedback mechanism available to achieve minimal thermal spread to be specified - * instrument recognition system Automatic instrument recognition Automatic instrument recognition
RequiredManual instrument recognition Interface modality for allowance of software upgrades USB USB The equipment shall conform to standards such as EN (IEC 606001-1-1-2
RequiredEN (IEC 606001-1-1-2) Yes * Should come equipped with system diagnostics and troubleshooting guide to pin point any problem in the system Yes Yes Well-equipped service centre should present in India with company trained OEM Enginee rs/Technicians approved by OEM Yes Yes Generator cart
Requiredoffered Yes Yes Adapters for ultrasonic and rafiofrequency instruments shall be supplied Yes Yes
RequiredNo Separate Hand piece (transducers) with various ultrasonic hand yes * 4/9 instruments of OEM used as per applicability in Open and laparoscopic surgeries to last for upto 90 cases Comprehensive Warranty in years for complete equipment which shall be from the date of installation
Requireddemonstration and training to consignee 5 1
Required2
Required3
Required4
Required5 Product Literature in original along with that of accessories and indigenous components if any to be supplied ( Photoc opies/computer generated copies are not acceptable) Yes Yes
RequiredNo " Comprehensive Maintenance Contract (CMC) which includes preventive maintenance including testing & calibration as per technical/service operational manual
Requiredabour and spares
Requiredafter satisfactory completion of Warranty period " 1 1
Required2
Required3
Required4
RequiredNo CMC after warranty Number of preventive maintenance visits during warranty period (Number per annum) 5 5 Certificate from OEM/principal regarding approval of service centre maintained by seller to be available Yes Yes
RequiredNo All software updates should be provided free of cost during warranty and CMC if Yes Yes 5/9 included "Complete technical training for personnel involved in the use and handling of the equipment on site at the buyer/consignee end immediately after its installation Yes * The unit shall be capable of being stored continuously in ambient temperature of 0 - 50 degree centigrade and humidity of 15-90% Yes * "The unit shall be capable of operating continuously in ambient temperature of 10 - 40deg C and relative humidity of 15-90%" Yes * Power supply 220-240 V AC
Required50 Hz single phase 220-240 V AC
Required50 Hz single phase Additional Parameters Ultrasonic 5 mm Laparoscopic hand activated curved tip coagulating probe supplied with maximum vessel sealing 0f 7mm 2 1
Required2 Ultrasonic 5 mm Laparoscopic hand activated curved tip coagulating probe supplied with maximum vessel sealing 0f 5 mm 2 1
Required2 Ultrasonic hand activated curved tip coagulating probe for open surgery supplied for up to 7mm vessel sealing 2 1
Required2 Ultrasonic hand activated curved tip coagulating probe for open surgery supplied for up to 5 mm vessel sealing 2 1
Required2 Advanced RF/Bipolar 5 mm Laparoscopic 2 1
Required2 6/9 hand activated curved tip coagulating probe supplied for up to 7mm vessel sealing Advanced RF/Bipolar 5 mm Laparoscopic hand activated curved tip coagulating probe supplied for up to 5 mm vessel sealing 2 1
Required2 Advanced RF/Bipolar hand activated curved tip coagulating probe for open surgery Suppliedfor 7mm vessel sealing" 2 1
Required2 Advanced RF/Bipolar hand activated curved tip coagulating probe for open surgery Suppliedfor up to 5mm vessel sealing 2 1
Required2 Main cable with power socket of standard indian make to be provided Yes Yes Suitable UPS with 30 min backup to be supplied with equipment Not supplied Not supplied Reports Certifications for product - * Certification no and date to be indicated - * Manufacturer should have ISO certification for quality standards Yes Yes ISO certification date and number (if no ISO certification provided then put NA) - * Complete system and all accessories except items like UPS
RequiredCable
RequiredAdapters etc should be from same or OEM Yes * * Specifications highlighted in bold are the Golden Parameters. 7/9 * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents