Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAccepted-AOC 138 PURBA PALLY KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | ₹6.8 Cr | L1 | Accepted-AOC As per Technical and Financial Evaluation. |
| 2 | L2₹6.9 CrRejected-Finance 87 20 BOSE PUKUR ROAD KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | ₹6.9 Cr | L2 | Rejected-Finance L2, Financially disqualified |
| 3 | L3₹7.0 CrRejected-Finance | ₹7.0 Cr | L3 | Rejected-Finance L3, Financially disqualified |
| 4 | Rejected-Technical 14L TELEPARA LANE DHAKURIA KOLKATA 700 031 | KOLKATA | WEST BENGAL | 700031 | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | BISWAS ENGINEERING L3 | Bharat Construction L1 | M/S UDAYAN CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | TOTAL QUOTED AMOUNT | 1 | LS | 6,98,22,142 ₹7.0 Cr | 6,77,85,879 ₹6.8 Cr | 6,92,44,747 ₹6.9 Cr |
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
27 Jan 2026, 3:00 pmClosed
Superintending Engineer
DG Block, Sector- II, Salt Lake City, Kolkata-700091
Beautification and Upgradation in connection with construction of 20 cottages and 100 seated Tourist lodge at Gangasagar
2026_WBTDC_982604_1
NIT No.102/WBTDCL OF 2025-26 (Technical)
Open Tender
CIVIL AND ELECTRICAL WORKS
240 days
Gangasagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10 L
27 Apr 2026
2 Jan 2026
29 Jan 2026
2 Jan 2026
27 Jan 2026
2 Jan 2026
TOTAL QUOTED AMOUNT
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Fountain
Pumping Unit:440V/12.5Hp; S*D 100mm*100mm Openwell Monoblock Submersible Pumpset with Stainer at Suction end. Brand Kirloskar/ Texmo.
Control Panel: Metallic enclosur (Sheet Steel Enclosure duly powder coated) fitted with reputed electronic components namely Voltmeter, Ammeter, Onn-off switch, Fuse, Indicator & other essential accessories for ensuring safety/security of operator. Double door, Outdoor type.
Nozzle Part : Precession jet ring fountain nozzle / 0,5" Male / Female threated connection. Make Brass Position for 30ft dia pipe ring, Spacing 1 ft uniform all around the pipe ring.
a. Plumbing Part : 2" dia GI / UPVC Pipe with fittings & fixtures inclusive of grilling job with tap incorporation of tap at regular interval & other items as follows
b. Multiway pressure manifold duly powder coated GI make
c. 2" dia pipe ring Mean diameter 30 ft uniform (1 no) with drill & tap at regular interval of 12 inches all around inclusive of stand.
RGB LED water resistant Fountain light (S.S body), 12 Volt/ 18 Watt
Light Controller with SMPS (220V, 12V)
Electrical Submersible cable : 1.5mm * 4 core for interconnecting lumineries with panel with conduit pipe
4 mm * 3 core for interconnecting pumpset with panel with conduit pipe
25mm Alimunium armoured cable 3.5 core for interconnecting supply point with control panel.
Packing Charges & Freight Charges
Installation, Commissioning & Trial Run charges
Pumping Unit:440V /15 Hp; S*D 100mm*100mm Openwell Monoblock Submersible Pumpset with Stainer at Suction end. Brand Kirioskar/ Texmo.
Control Panel: Metallic enclosur (Sheet Steel Enclosure duly powder coated) fitted with reputed electronic components namely Voltmeter, Ammeter, Onn-off switch, Fuse, Indicator & other essential accessories for ensuring safety/security of operator. Double door, Outdoor type.
Nozzle Part : Precession jet ring fountain nozzle / 0,25" Male / Female threated connection. Make Brass Position for 14 ft dia & 12ftt dia pipe ring, Spacing 5 inch for 14ft dia pipe ring Spacing 6 inch for 12ft dia pipe ring
b. Centre Jet nozzle with ball Joint & fittings / fixtures
a. Plumbing Part : 1.5" dia GI / UPVC Pipe with fittings & fixtures inclusive of drilling job along with tap incorporation of tap at regular interval & other items as follows
b. Multiway pressure manifold duly powder coated GI make
c. 2" dia pipe ring Mean diameter 14 ft uniform & 12 ft uniform (1 no) with drill & tap at regular interval of 5 inches & 6 inches respectively all around inclusive of stand.
RGB LED water resistant Fountain light (S.S body), 12 Volt/ 18 Watt
Light Controller with SMPS (220V, 12V)
Electrical Submersible cable : 1.5mm * 4 core for interconnecting lumineries with panel with conduit pipe
4 mm * 3 core for interconnecting pumpset with panel with conduit pipe
Packing Charges & Freight Charges
Installation, Commissioning & Trial Run charges
ELECTRICAL
Supply & Fixing of Hooded type L.T Feeder pillar box of appropiate size & specification having rigid & self supportingstructure fabricated with sufficient no of MS angle(25x25x3mm),MS flat etc.The body and top portion will be fabricated by 3MM and 5M thick MS plate product and bottom portion by 10 MM thick. Cast Iron, double door arrangement with two handles to be done both on front and rear side and proper ventilation at the top of two sides is to be made by the close mash brush net. Provision of manual pad locking arrangement are to be provided on both door provision for earthing at both ends are to be provided. The MS portion will be painted by two courses of aluminium paint over one coat of RO primer, and CI portion will be painted by two coat of Block paint after finishing the surface properly and comprising following accessories as directed by EIC.(For Fountain Pump) Incoming- a) 415 V 53A 4PMCB (Legrand)- 1 (one) no. b) 415 V 53A 4bar Aluminium bus bar (Legrand)- 1 (one) no. Outgoing- a) 415 V 32A 4PMCB (Legrand)- 3 (Three) no. b) 415 V 4P ML3 contractor Block(LT Make)- 1 (one) no. c)Programmable time switch-234 hrs(LT Make)-1 nos.
Supply & Fixing of Hooded type L.T Feeder pillar box of appropiate size & specification having rigid & self supportingstructure fabricated with sufficient no of MS angle(25x25x3mm),MS flat etc.The body and top portion will be fabricated by 3MM and 5M thick MS plate product and bottom portion by 10 MM thick. Cast Iron, double door arrangement with two handles to be done both on front and rear side and proper ventilation at the top of two sides is to be made by the close mash brush net. Provision of manual pad locking arrangement are to be provided on both door provision for earthing at both ends are to be provided. The MS portion will be painted by two courses of aluminium paint over one coat of RO primer, and CI portion will be painted by two coat of Block paint after finishing the surface properly and comprising following accessories as directed by EIC.(For Ligtening Power) Incoming- a) 415 V 53A 4PMCB (Legrand)- 1 (one) no. b) 415 V 53A 4bar Aluminium bus bar (Legrand)- 1 (one) no. Outgoing- a) 415 V 32A 4PMCB (Legrand)- 3 (Three) no. b) 415 V 4P ML3 contractor Block(LT Make)- 1 (one) no. c)Programmable time switch-234 hrs(LT Make)-1 nos.
Supplying and fixing 415V 63A 4-Pol Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc including S&F sheet steel (16SWG) cable end box at both ends with power-coated painting as per GS.(Make-L&T/Simence/Havells/HPL)
Supplying and fixing 415V 32A 4-Pol Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc including S&F sheet steel (16SWG) cable end box at both ends with power-coated painting as per GS.(Make-L&T/Simence/Havells/HPL)
Supply and delivery of 1.1 KV great 4core 16sqmm XLPE/PVC Ar AI Cable as directed by EIC (Make-Polycab/Havells/RR kabel/ Gloster).
Supply and delivery of 1.1 KV great 4C x 16 sqmm XLPE-armoured Cable as directed by EIC (Make-Polycab/Havells/RR kabel/ Gloster).
Supply and delivery of 1.1 KV great 4C x 10 sqmm XLPE-armoured Cable as directed by EIC (Make-Polycab/Havells/RR kabel/ Gloster).(For Compound Light)
Finishing the end of above PVC insulated and unsheathed copper ware as per GS.i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply and fitting 3 m long aesthetically designed decorative hot deep galvanised mild steel step pole with grey powdered finish plasma cut and Dooly Kaempfer opening window of 300 x 110MM for terminal connection and mountain accessories compatible for above LED postop fitting as directed by EIC.(Make- As approved by EIC )
Foundation of above pole with base flange and foundation nuts, bolts, etc on RCC(4:2:1) step foundation having(L-450 mm x W-150 mm x H-450 mm) below the ground level and(L-300 mm x W-300 mm x H-150 mm) above ground level, including neatly cemented, finish(3MM thick) above ground level, including earthing connection, etc, and carriage of pole up to 1.6 km from the store to work side, including feeling up the pit with shifted Soil and rhyming properly as per direction of EIC.
Supply and fixing of 45W decorative circular LED postop light fittings with Di cost, aluminium body and copper pisi cover IP66 and IK07 rating till Amit varied environmental condition with necessary connection as per GS(make-Havells/Phillips/signify/Crompton)
Supply and deliver of 10 W decorative LED bullet in IP66 to ensure sustainable performance in all section, which keeps the surrounding lively, including Nursery interconnection as per GS(make-Havells/Phillips/signify/Crompton).
S &D of 9W decorative Spike LED light with compact lightweight energy saving IP66 spike like using COBLED as offered in mono rate, green blue and warm white colour in multipurpose application, including Srvr connection as per GS(make-Havells/Phillips/signify/Crompton).
S & F of 50 W, decorative LED area, light fitting and with environmental friendly new generation energy saving IP66PC diffuser, including nature, interconnection as per GS(make-Havells/Phillips/signify/Crompton).
Supply and fitting of flex strip LED in IP65 version 50M of each trip, which long system life of 5 0000 burning hours with mounting accessories, including AI channel, pisi, diffuser ladder cable and mounting clips as per direction of EIC.(Make-Phiulips/CG/Havells)
Supply and fitting of 50W decorative mono colour Jeta Quanto plus floodlight luminous with IP66 pressure cast aluminium body and clear pisi cover and standard Bengle of 30° aesthetic consistency in multipurpose application, including necessary connection as per GS.(Make: Havells/JETAQUANTOPLUSFLS50WLEDP30DPC/Philips/Crompton )
S&F of 20W decorative LED round type pendant light fitting, including Nursery proper connection as per direction of EI(Make-Phillips/Havells-LHEHBTP5UN1W020/Crompton/Bajaj/Wipro)
S &F of 12W, decorative LED line light fitting, including SI proper connection as per of EIC.(Make-Phillips/Havells-LHEUADP5UJ012/Crompton/Bajaj/Wipro)
Supply and delivery of single LED fitting (18 W, 230 V, 50 Hz, 4000 K, NW, THD< 10% built in 25KV SPD) with all accessories and one noise elite Tube as directed by EIC.[Make-Phillips, Havels, Bajaj,GG or as per EIC](luminous effect> 105 and< 120 lumen/watt. The LED luminaries and shall have BEE certificate.
Supply and delivery of 1200MM sweep 230 V AC ceiling fan, including blades, canopy, et cetera, with 18 inches down road(14SWG), fork(10SWG) heavy type insulated 3/8 inches bolt with not heavy type split pin, etc with safety wear, and PS2 type capacitor as directed by EIC[Make-Orient(1200 mm metallic bronze copper) or similar space of crompton/Havels(safety wear and S3/P2 capacitor)
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Pool,Gazebo & Bridge
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
(b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand.
Single brick soling with picked Jhama bricks including preparation of bed as necessary with cement-sand mortar properly filled up and poised with powdered earth and including necessary confine courses of single brick about below the outline of construction in layers when more than one layer is used, completes as per direction
Brick edging 75 mm wide with picked Jhama bricks, laid true to line and level including cutting necessary trench in soil or pit, and preparing bed and backing the bricks and repairing the trench (on both side of the edging) with spoils and ramming the same thoroughly complete as per direction. a) Brick on edge edging (250 mm) depth
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including steel Shuttering.(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Ground Floor.
(f) 25 mm to 30 mm shuttering without staging in foundation
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge annealed wire / welded for pile cage at every intersection, complete as per drawing and direction.tor steel/ Mild steel ( Tata/Sail/Rinl)a) In Foundation & Ground Floor
Providing Anti corrosive fusion bonded epoxy coating (FBEC) to reinforcement to IS 13620-1993(with fatest amendment) for a thickness of 100 microne to 300 microne aftercuring as per Annexture-A of IS13620(1993)(with letest amendment) and application of coating shouild be as per CI of IS:13620(1993)(with letest amendment) including preparation of surface,it also include the charges of all necessary tools and plants.This item shall be executed only after specific instruction of Superintending Engineer of the respective circle.
Cement concrete with graded balast(40mm size excluding shuttering) in ground floor as per relevant IS code.i) Pakur Variety.a)1:3:6
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS :456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in-charge. Consumption of cement will not be less than 450 kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job mix formula. In Ground floor & foundation. [Using concrete mixture] .Pakur Variety M 25 gradea) In Foundation & Ground Floor
Labour for chipping of concrete surface before taking up.
Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor
Supplying, fitting & fixing UPVC pipes A - Type and fittings conforming to IS:13592-1992 of all necessary sizes in cast iron collars, including cutting holes in walls, floor etc., cutting trenches in any soil through masonry concrete structure work etc. if necessary and mending wall/floor/column including jointing with jointing materails (Spun Yarn, Valmoid/Bitumen/ M. Sealer) complete.ii)110 mm
B)UPVC Fittings
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface].(ii) With 1:4 cement mortar - 15mm thick Plaster (a) In Ground Floor
10mm thick Plaster (a) In Ground Floor
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, neat planes and dressing with topping made with ordinary or white cement (as necessary) and matching dust/chips proportion (1:2), including smoothing, finishing and rubbing off corners, using grey cement: (iii) 35 mm thick (Drain, Steps)
Supplying, fitting & fixing of 2-Track/3-Track Aluminium sliding Window of all Aluminium sections, with window frame (top, bottom & sides), shutter (top, bottom, side & inter-member), fitted with clear/tinted glass (excluding cost of glass), complete as per architectural drawings and direction of Engineer-in-charge. (B) Minimum thickness Anodizing Film.Natural White
M.S.intrigated grill of approved design joints intrigated with steel window or ventilation ,joints continiously welded with M.S Flats and bars.s in ground floor.. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr a) In Ground Floor
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987;
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m i)other than colour decorative including white
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineerin- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor] iii) Mural Aligned/CAD Design type
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5. a) 25 mm thick Tiles as per IS: 1237-2012 for footpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department). (ii) Coloured Decorative
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper / Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. - One Coat with Solvent based interior grade Acrylic Primer.
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer c) Super Protective 100% Acrylic Emulsion. a) In Ground Floor
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC In Ground Floor: (a) One Coats
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) - Standard Quality.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(a) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
(a) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778:2007 with all necessary accessories, specials viz. socket,bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. A) For Exposed Work.I)CPVC Pipes Class-I,SDR-11. a) 15 mm dia
b)20 mm dia.
c) 25 mm dia.
d) 40 mm dia.
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). V) 40 mm dia.
vii) 25 mm dia.
Supplying,Fitting and fixing bib cock or stop cock.a) ii) Chromium Plated Bib Cock Long body with wall flange with aerator.
a)PTMT (prayah or Equavalent)
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (ii) Double Socketed 3 Meter Length (b) 110 mm
(B) Fittings ii) Plain Tee b) 110 mm
x) Bend 87.5º .(b) 110 mm
Xiii) Cross Tee. b) 110 mm
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground.b) 110 mm
(A) under ground.(ii) 110 mm dia.
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special per approved technology of Department of Science and Technology (DST) tosandwich core, so as to impart monolitaheic composite structure as safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Gate ,Land Development & Protection Work
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
(a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. {Payment will be made on profile measurement before and after the work). b)iii)With carried earth arranged by the contractor within a radius exceeding 56 kmn. but not exceeding 10 km. including cost of carried earth.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Bailling or pumping out water from foundation trenches.
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
Cement concrete with graded balast(40mm size excluding shuttering) in ground floor as per relevant IS code.i) Pakur Variety.a)1:3:6
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works.(upto roof of ground floor). Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.
(f) 25 mm to 30 mm shuttering without staging in foundation
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS :456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in-charge. Consumption of cement will not be less than 300 kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job mix formula. In Ground floor & foundation. [Using concrete mixture] .M 25 grade
Labour for chipping of concrete surface before taking up.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and a)For works in foundation and upto roof of ground floor. SAIL/TATA/RINL 2% of concrete vol 430.21
Providing Anti corrosive fusion bonded epoxy coating (FBEC) to reinforcement to IS 13620-1993(with fatest amendment) for a thickness of 100 microne to 300 micron aftercuring as per Annexture-A of IS13620(1993)(with latest ammendment) and application of coating shouild be as per CI of IS:13620(1993)(with latest ammendment) including preparation of surface,it also include the charges of all necessary tools and plants.This item shall be executed only after specific instruction of Superintending Engineer of the respective circle. NOTE:- 8mm , 10mm, 12mm, 16mm, (17.00+16.00+15.00+14.00)/4 = Rs 15.50 x 30% riverine = Rs 20.15
Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth
(b)In superstructure, groundfloor Entry gate and exit gate 2x1x4.500x0.250x4
Supplying, fitting & fixing UPVC pipes A - Type and fittings conforming to IS:13592-1992 with all necessary clamps nails,including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structure work etc. if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valmoid/Bitumen/ M- Seal etc) complete (A) UPVC Pipes ii)110 mm 16x6
B)UPVC Fittings c) Bend 87.5 degree ii)110 mm 16x3
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking or roughening of concrete surface,including throating, nosing and drip coursebwhere necessary (Ground floor). (i) With 1:4 cement mortar c)15mm thick G. Floor
10mm thick Plaster Ground Floor
(i) With 1:6 cement mortar (b) 20 mm thick plaster Retaining wall 1x1x101.000x1x1.500
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineerin- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor] iii) Mural Aligned/CAD Design type Inside water body 1x1x202.00x1x1.750
M.S gate of Jail type as per approved design made of strong M.S frame work, intermediate stiffeners and round/ square bars orangles. M.S. sheet (not less tyhan 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hganging arrangements, fitting and fixing complete as per direction of the Engineer-In -charge. In ground floor Gate @ 50 kg/sq 2x1x7.00x3x0.50 mt
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On steel or other metal surface. (iv) Two coats (with any shade except white)
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor roughening of concrete surface complete. Area of each Granite slab> 0.6 upto 1.0 square meter.(Using cement slurry at back side of granite @ 4.4 kg/sq,m & white cement slurry for joint filling @ 1.8 kg/sq.m) roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 sq.m
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m i)Other than colour decorative including white Wall of railing 1x2x90.000x1.00x0.750
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. a) 25 mm thick Tiles as per IS: 1237-2012 for footpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department). (ii) Coloured Decorative
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC (a) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer a) Super Protective 100% Acrylic Emulsion. Ground Floor (two coat)_
Boundary Wall
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
Cement concrete with graded balast(40mm size excluding shuttering) in ground floor as per relevant IS code.i) Pakur Variety.a)1:3:6
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS :456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in-charge. Consumption of cement will not be less than 300 kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job mix formula. In Ground floor & foundation. [Using concrete mixture] .M 25 grade
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and a)For works in foundation and upto roof of ground floor. SAIL/TATA/RINL 2% of concrete vol 430.21
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works.(upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation
c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor
Labour for chipping of concrete surface before taking up plastering work.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On steel or other metal surface. (iv) Two coats (with any shade except white)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking or roughening of concrete surface,including throating, nosing and drip coursebwhere necessary (Ground floor). (i) With 1:6 cement mortar (b) 20 mm thick plaster
(i) With 1:4 cement mortar b)15mm thick G. Floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC In Ground Floor .(a) One Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer a) Super Protective 100% Acrylic Emulsion. Ground Floor (two coat)_
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. {Payment will be made on profile measurement before and after the work). iii)With carried earth arranged by the contractor within a radius exceeding 5 kmn. but not exceeding 10 km. including cost of carried earth.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand.
Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS code.i) Pakur Variety.
Granular Sub-base with Graded Material: A. Plant Mix Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).(iii) Grading-III.
Water Bound Macadam Base Course:Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading inuniform thickness, hand packing, rolling withvibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up them interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (ii) Grading-I Aggregate (63 mm to 45 mm) Using Stone Screening Type B (11.2 mm).B.Manual Means
(iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm).B.Manual Means
C) Supplying and Laying in the specified pattern of interlocking Precast Concrete Blocks (ICBP) with concrete blocks (with Concrete Grade as specified as per Table 4 of IS: 15658 - 2006, manufactured from BIS licensed manufacturer), with spacer nib (small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. No. 1.2(a) of IS: 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per Cl No. 3.3 of IS: 15658) as per Table 2 of IS: 15658, with flexural strength/breaking load as per Annexure G of the prepared base course of specified CBR as per Table 4 of IRC SP-63 (2018) or else as mentioned in design and drawing. With a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP-63) and compacting the edges with cut blocks as per Cl. No. 8.7 of IRC SP 63 (2018) with proper confinement of bedding and joint filling sand, compaction leveling and filling up of the edge gap 60 mm thick, (ii) Coloured Decorative for approach & connective Road & Car parking
Security Kiosk
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand.
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures
Cement concrete with graded balast(40mm size excluding shuttering) in ground floor as per relevant IS code.i) Pakur Variety.a)1:3:6
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS :456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer- in-charge. Consumption of cement will not be less than 450 kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job mix formula. In Ground floor & foundation. [Using concrete mixture] .Pakur Variety M 25 gradea) In Foundation & Ground Floor
Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth
b) In superstructure,Ground Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including steel Shuttering.(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Ground Floor.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge annealed wire / welded for pile cage at every intersection, complete as per drawing and direction.tor steel/ Mild steel ( Tata/Sail/Rinl)a) In Foundation & Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface].(i) With 1:6 cement mortar - 20mm thick Plaster (a) In Ground Floor
(ii) 15mm thick Plaster
(ii) With 1:4 cement mortar -10mm thick Plaster
(ii) With 1:4 cement mortar -15mm thick Plaster
Neat Cement Punning about 1.5 mm thick in wall dado,window sill floor etc.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS code.i) Pakur Variety.
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
Supplying, fitting & fixing of 2-Track/3-Track Aluminium sliding Window of all Aluminium sections, with window frame (top, bottom & sides), shutter (top, bottom, side & inter-member), fitted with clear/tinted glass (excluding cost of glass), complete as per architectural drawings and direction of Engineer-in-charge. (B) Minimum thickness Anodizing Film.Natural White
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor roughening of concrete surface complete. Area of each Granite slab> 0.6 upto 1.0 square meter.(Using cement slurry at back side of granite @ 4.4 kg/sq,m & white cement slurry for joint filling @ 1.8 kg/sq.m) roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 sq.m
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special per approved technology of Department of Science and Technology (DST) tosandwich core, so as to impart monolitaheic composite structure as safisfy IS: 4020 door testing performance criteria.. (i) 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vii) 100mm. X 58mm. X 1.90mm.
Anodised aluminium barrel/tower/socket bolt (fullcovered) of approved quality manufactured from ex-truded section conforming to I.S.204/74 fitted andfixed with cadmium plated screws : (v) 100 x 63 x 3.2mm
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC In Ground Floor: (b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer a) Norma Acrylic Emulsion. a) In Ground Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper / Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. - One Coat with Solvent based interior grade Acrylic Primer.
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) - Standard Quality.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; i) 6mm thick clear glass.
Landscaping
Maintenance of Lawns or Turfing of Slopes Maintenance of lawns or Turfing of Slopes (rough grassing) for a period of one year including watering etc.
Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment).
Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%).
Spreading of sludge, dump manure/farm yard manure/ animel dung manure and good earth in required thickness. This includes supply of labour, tools & plants excluding materials.
Planting and Maintaining of Permanent Hedges (a)Planting permanent hedges including digging of trenches Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart. Both side of Emtrance Road 2x1x1.00x1x410.00
(b)Maintenance of Hedge for one year 2x1x1.00x1x410.00
Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc.
i) Furcaria veriegated 10-12 leaves in height 20-30cm in earthen pots of size 25cm
ix) Ficus bengalensis (variegated) of height 60-75cm in earthen pots size 30cm
xiv) Acalypha species ( Red/Green) of height 30cm-90cm in earthen pots of size 25cm.
xvi) Adenium obesum of height 90cm-60cm in earthen pots of size 25cm.
xxiii) Hibiscus Rosa Sinensis of height 90 cm to 60 cm in earthen pots of size 20 cm.
xvi) Areca Palm 4 - 5 suckers of height 90 cm to 105 cm in earthen pots of size 25 cm.
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree. only Both side of Road @ 4.0 m c/c plantation for 410 m road
Maintanance of trees for one year (Avenue Plants) including watering, trimming, manuring, spraying insecticide and guarding as required. This includes supply of labour, tools & plants including materials
Roof treatment
Roof treatment by application of non toxic polyurethane modified acrylic based single component (P.U Roof Coat) solvent free, cold applied polyurethane modified elastomeric waterproofing membrane with excellant UV resistant capacity as per ASTM D6083 & water based 100% acrylic elastomeric emulsion polymer latex coating used as protective coating for roof after preparing the surface by cleaning and repairing the roof cracks by cement & sand mortar (1:4) (preferably with anti-shrinkage mortar, etc. to be paid seperatly) if any, apply two coats along with a priming coat (two coats of PU Roof Coat and one of primer coat compatible with main product as per manufacturer's specification) and reinforced with or without 20 gsm Geotextile Fleece, including the cost of primer coat and base preparation, tools & plants but excluding the cost of scaffolding and staging complete as per direction of Engineer -in-Charge. (Note: If Geotextile Fleece not used, rate would be reduced by Rs 5 per Sq.m)
Electrical
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish.Average run 8 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.On Board
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make-L & T/Havells/Standard)
Supplying and fixing 415V, 32A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make-L & T/Havells/Standard)
415 V,100 Amp capacity 99.9%-99.5% electrolytic tinned 4 bar copper bus bar(size of flay 4 x 15 x 3 mm)/Equivalent size) mounted on non-hygroscopic percolin insulator/sheet having sufficient di-electric strenth duly wrapped with colour PVC tapes (Red,yellow,black & blue) for phases & neutral identification.-1set
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed,as per GS.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4C x 16 sqmm XLPE/PVC armoured cables as per GS
Finishing of the 4C x 16 following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials ,as per GS.
Laying of of the 4C x 16 sqmm XLPE/PVC armoured cables in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed,as per GS.
Supply & Fixing Finishing of the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket 4C x 6 sqmm (Dowels make), tapes, anticorrosive paste & jointing materials ,as per GS.
Supplying and fixing compression type cable end gland complete with finishing end by crimping method for the following size for 4C x 16 sqmm XLPE-A/AI armoured cables as per GS.
Laying of of the above 4C x 10 sqmm XLPE/Ar. AL cables in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed,as per GS.
Supplying and fixing compression type cable end gland complete with finishing end by crimping method for the following size for 4C x 10 sqmm XLPE-A/AI armoured cables as per GS.
Supplying and fixing Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket 4C X 10 sqmm(Dowels make), tapes, anticorrosive paste & jointing materials as per GS.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC(For compound light loop box to led fitting).
Fixing only above light fitting complete with all accessories by providing CC(6:3:1) base block dimension 0.45 x 0.45 x 0.60 mt. (0.3 Mtr. Above ground level),neatly cemented finish (3mm thick),without Loop Box as per GS.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. lengt
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wires as per direction of EIC.
upply & fixmg two pieces type fabricated beam to beam clamp (approx. length 2mtr.) made with 50 x 6mm MS strip suitable for fixing of special type of Fan Clamp and also tube light fitting to maintain uniform spacing, meluding S&F 4nos Nut-bolts for fixing of clamp on Iron T-section as per direction of EIC.
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required as per Direction of EIC.D) with 50mm dia GI Pipe.
Supplying & Fixing Gl waterproof type looping cable box size 200 x 150 x 100 mm deep having 4mm thick comprising of one 250 V 15 A Kit-kat fuse unit, one NL on porcelam insulator, one compression type brass cable gland for upto 2 core 16 sqmm PVC /A cable and having with lug,on steel tubular pole near base,including S&F 40x6mm thick,MS clamps with bolts,nuts etc. including painting with anticorrosive paint.
Earthing with 50mm dia. GI pipe 3.64mm thick x 3.04 Mtr. Long and 1 x 4 SWG GI(Hot Dip) wire (4 Mtr.) ,13 mm dia x 80 mm long Gl bolts, double nuts, double washers including S & F 15mm dia GI proptection(1Mtr. long) to be filled with bitumen partly under the ground level and partly above ground level; driven to an average depth of 3.65 Mtr. below the ground level as below By ISI-Medium GI Pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming (For Soft Soil).
Supply & fixing of 25 x 6 mm thick GI (Hot Dip) flat/ strips for Horizontal & Vertical on wall/floor with Gl shaddles as required including drilling holes, bolts, muts, washers, /and mending good the damages to building works (Page G-3/tem-5d)
Sub Total
Add GST @18% .
Sub Total
Add labour welfare Cass @ 1%
INR Five Crore Ninety One Lakh Eleven Thousand Three Hundred & Seventy One Only
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.94 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2396955.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid