Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹8.3 L
EMD Value
₹16,555
Closing Date
20 Jul 2020, 4:00 pmClosed
Executive Engineer STD Ganderbal
Office of Executive Engineer STD Ganderbal
Realignment of 33KV Alasteng Power House Line passing through Breached spot at RD1550 of Sindh extension Canal
2020_PDD_99467_1
STD/GBL/11 of 2020-21
Open Tender
Electrical Works
Turn-key
20 days
Ganderbal
Refer SBD, DDUGJY Specifications, REC Drawings
7 documents required · 7 mandatory
₹1,000
Executive Engineer STD Ganderbal
₹16,555
22 Jul 2020
3 Jul 2020
21 Jul 2020
3 Jul 2020
20 Jul 2020
4 Jul 2020
3 Jul 2020 - 20 Jul 2020
Amount
Realignment of 33KV Alasteng Power House Line passing through Breached spot at RD1550 of Sindh extension Canal
Supply, Transportation, Erection, testing and commissioning of 11 mtr ST Pole ST-410 SP56 including loading, unloading and carriage upto siteexcavation of pit and Planting of Pole upto 1.8 Mtr in depth and refilling with boulders upto 1 feet as per REC standards (Specification and erection as per REC Drawings and DDUGJY Specifications)
Supply, transportation, fabrication, erection and commissioning of GI V cross-arm with top Bracket including clamp, 8 feet long or as per site requirement
Supply, transporation, fabrication, erection and commissioning of GI Channel X-arm including clamps and braces 10 feet long or as per site requirement
Supply, transportation, fixing, testing and commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm (Specification and erection as per REC Drawings and DDUGJY Specifications)
Supply, transportation, fixing, testing and commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm (Specification and erection as per REC Drawings and DDUGJY Specifications)
Supply, transportation, laying, stringing, testing and commissioninh of 200 mm² ACSR Conductor
Supply, transportation and fixing of PG Clamps for 200 mm² ACSR Conductor
Supply, transportation and fixing of Galvanized Nuts and Bolts. (Specification and erection as per REC Drawings and DDUGJY Specifications)
Supply, transportation and laying of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. (Specification and erection as per REC Drawings and DDUGJY Specifications)
Providing, transportation and laying of Cement bottoming 1:2:4 mix as per REC standards .6cum /pole (Specification and erection as per REC Drawings and DDUGJY Specifications)
Supply, transportation, fixing, testing and commissioning of Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete (Specification and erection as per REC Drawings and DDUGJY Specifications)
Supply, transportation and applying of Aluminium Paint
Supply, transportation and applying of Red Oxide
Dismantling of old line
Dismentaling of 11 Mtr ST Pole complete including breaking of cement bottoming if any.
Dismantling of 200 Sqmm ACSR Conductor
Dismantling of GI Channel X-arm including clamps and braces 5 feet long, 4No.
Dismamtling of 33 KV Pin Insulators
Manual carriage of above dismantled Material from Dismantling Site to Loading Site upto 1.5 KM
Motorised Carriage of Dismantled Material from loading site to Divsional Store
M/S SHEIKH ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .