| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.6 L+₹966.15 (0.17%)Accepted-AOC | L2 | Accepted-AOC L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Contract Registration Certificate expired |
| Sl No | Description | Qty | Unit | ABDUL LATHIEF L1 | SHAHUL HAMEED.KA L2 |
|---|---|---|---|---|---|
| 1.00Re Construction of compound wall | |||||
| 1.00 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 6.64 | cum | 2,017 ₹13,392.88 | 2,016 ₹13,386.24 Lowest |
| 1.00 | 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) | 12.95 | cum | 7,901 ₹1,02,317.95 | 7,900 ₹1,02,305 Lowest |
| 1.00 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | 1.85 | cum | 9,933 ₹18,376.05 | 9,932 ₹18,374.2 Lowest |
| 1.00 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 7.4 | sqm | 365 ₹2,701 Lowest | 365 ₹2,701 Lowest |
| 1.00 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 148 | kilogram | 106.5 ₹15,762 | 106 ₹15,688 Lowest |
| 1.01 | 50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete | 10.18 | cum | 6,469 ₹65,828.54 | 6,468 ₹65,818.37 Lowest |
| 1.01 | 50.6.3.1:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete | 2.12 | cum | 7,294 ₹15,499.75 | 7,293 ₹15,497.63 Lowest |
| 1.01 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 178.11 | sqm | 350 ₹62,339.2 Lowest | 350 ₹62,339.2 Lowest |
| 1.01 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | 178.11 | sqm | 76.5 ₹13,625.57 Lowest | 76.56 ₹13,636.25 |
Tender Value
₹5.9 L
EMD Value
₹14,726
Closing Date
7 Aug 2025, 1:00 pmClosed
The Assistant Engineer
The Assistant Engineer, LSGD Section, Mannancherry Grama Panchayat, LSGD Section, Mannancherry Grama Panchayat
Annual Plan-Mannancherry GP -2025-26-Re construction of Compound wall and Maintenance of North aryad UPS in ward -10-Pro No -315/26-General Civil Work
2025_LSGD_776034_2
CELSGD/TR/69022/2025_5_1_1/1
Open Tender
Repair and Maintenance Works
Item Rate
180 days
Mannancherry Grama Panchayat
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,300
Yes
₹14,726
Yes
24 Sept 2025
30 Jul 2025
9 Aug 2025
30 Jul 2025
7 Aug 2025
30 Jul 2025
Amount
Re Construction of compound wall
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.6.3.1:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD130086/2025-2026:Providiing ACP cladding and fixed in aluminium frames and necessary clips and hooks etc complete with ACP sheet 3mm thick aluminium frame strips fixed in steel frames aluminium frame 25x25mm rubber beading and necessary clips and hooks labour etc complete as per the direction of departmental officers at site.
OD130121/2025-2026:Supplying and fixing Stainless steel lettering 304 grade 22 guage & 3D & to the existing frame work including fitting charge rate for 25 cm hight and 4cm bold and above
OD130122/2025-2026:Supplying and fixing Stainless steel lettering 304 grade 22 guage & 3D & to the existing frame work including fitting charge rate for 15 cm hight and 4cm bold above
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD122839/2025-2026:Providing and fixing aluminium Trafold sheet pre coated (size, shape and pitch of corrugation as approved by Engineer-incharge) 0.30 mm or nearest available thickness,total coated 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and thickness with zinc coating 120 grams per sqm as per IS: 277, inpolyester top coat 15-18 microns. Sheet should have protective guard film of 25microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge.The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curvedsurfaces, excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required.
OD130128/2025-2026:Dismantling and re setting on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
OD130137/2025-2026:Laying on departmental roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern set in cement mortar 1:3 including finishing edges (Item 12.49 modified)
OD130138/2025-2026:Supplying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern (modified 12.49)
OD130139/2025-2026:Supplying pressed roof clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern at site including all charges (Item 12.48 modified).
SHAHUL HAMEED.KA (BID ID -2278019)
Bidder Name
ABDUL LATHIEF
SHAHUL HAMEED.KA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1278201.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .