AGE I R AND D KOCH
AGE I R AND D KOCHI, THRIKKAKARA,KAKKANAD, KOCHI 682021
REPAIR MAINTENANCE OF FIRE ALARM DETECTION SYSTEM AND LIGHTENING PROTECTION AT TECHNICAL BLDGS OF NPOL, KOCHI
2024_MES_668291_1
8306E8AGERDK
Open Tender
Electrical and Maintenance Works
Works
330 days
kakkanad
As per tender doucuments
6 documents required · 6 mandatory
₹500
Yes
₹17,000
Yes
15 May 2025
30 Aug 2024
28 Sept 2024
30 Aug 2024
25 Sept 2024
6 Sept 2024
Amount
Periodical service/ Comprehensive maintenance of fire Alarm /Detection system comprising of Fire alarm panels with battery backup, Manual Call Points (MCPs), Heat/Smoke detectors, Hooter/strobe, response indicators, Electric siren etc at following buildings complete including testing with smoke detector tester, functionality of all components, cleaning all devices, checking all control circuit and connection from sensor to microprocessor based fire alarm panel, for smooth functioning by employing skilled tradesmen. (Rate inclusive of any repairs involved and also replacement of unserviceable spares. Required spares shall be measured and paid separately under relevant items of this schedule as 'supply only').
Coop Bldg of NPOL
TIRC at Main Lab Bldg
MATS Lab Bldg
SONIC Lab Bldg
MS Lab Bldg
QS Lab Bldg
Main Lab Bldg
Note:- (i) Contractor shall maintain all the documents and produce to the concerned Engr-in- charge as and when required.
(ii) The contractor should attend any complaint / break down immediately at par of number of times on call basis
(iii) The technicians employed should be trained and having sound knowledge about fire detecting /Alarm system.
(iv) Checking the serviceability of smoke detector by creating the heat / smoke artificially at sensing range of smoke detector and rest the alarm panel after checking each smoke detector and also to check the indication of alarm panel as per Zone wise. Contractor shall give the demo and training for all duty staffs about the fire alarm system. The unit rate quoted is deemed to be included for the same
Note for Ser item No 1:- The contractor shall visit the site before quoting tender. The quoted rate is inclusive of replacement of all defective minor spare parts required for rectification of the system. Any other major parts contractor will bound to replace the same and extra payment in this regards paid to contractor. Rate for the same is inclusive in quoted rate. (ii) Contractor shall fully responsible for satisfactory performance of plant parameters during complete duration of contract period. During Comprehensive maintenance period any type of fault ( Minor) occurs in Fire Alam Control System shall attending and rectify it without cost. No payment is admissible in this account to contractor.
Supply only Digital Multi Sensor detector with smoke &heat combination, all as specified and directed. Make: Cooper/GST/System Sensor
Supply only Sounder cum strobe (Hooter). all as specified and directed
Supply only manual call point resettable type all as specified and directed.
Supply only Response Indicator all as specified and directed.
Supply only fire alarm 4 Zone panel including disconnecting all connections from existing panel and connect the same to new panel complete all as specified and directed.
Supply only fire alarm 8 Zone panel including disconnecting all connections from existing panel and connect the same to new panel complete all as specified and directed.
Supply only 1.5 Sqmm 2 core PVC insulated un sheathed FRLS multi stranded copper conductor Cable on wall/laying with suitable size of fixing arrangement all as specified and directed
Supply only battery 12 volt 7 AH for fire alarms and control panels including incoming and outgoing connection complete all as specified and directed.
Material and labour for checking of fire/ smoke detector by artificial means to check the serviceability of all detectors periodically & Submitted their test certificate to department complete all as specified and directed.
M & L for in replacement of Air termination, single pointed aluminium rod 12 mm dia and 300 mm long all as specified and directed by Engr-in-Charge.
M & L for in replacement of test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screwed all as specified and directed by Engr-in-Charge.
M & L for in replacement of galvanised iron strip 32 x 6 mm buried in ground with saddles and fixing screws etc for roof conductors and down conductors including removing and replacement of deteriorated SS bolts, nuts and washers as required at site etc in the existing GI strip of any size from the starting point to upto the end connected points all as specified and directed by Engr-in-Charge.
M&L Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron strip 25 X 4mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm GI tubing light grade and necessary fittings for protection of GI strip including laying of charcoal , dust and common salt, PCC 1:2: 4 type B 1 using 20 mm graded aggregate with earth pit with 40 X 40 X 6.0 mm MS angle iron frame RCC cover 40 mm thick (1:2: 4) Type C0 (using 12.50 mm graded stone aggregate) reinforced with 8 mm dia round bar @ 75 mm C/C both way with plastering 15 mm thick CM ( 1: 6) internally and up to 150 mm below ground level externally, PGI funnel with wire mesh, 20 mm dia medium grade GI pipe for watering complete and connected to earth test point including testing and taking out old earthing complete all specified and directed. Note: No JCB excavation permitted.
Materials and labour for repairing of the earthing complete with digging and filling the salt and charcoal 5-10kg and refiling sand including chamber plaster, providing the RCC cover of the required size including all necessary work as per direction complete all as specified & directed
Providing and fixing 25mm X 4mm G.I strip 40 mm dia G.I pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation, and refilling etc as required.
Supplying and laying 4 mm dia copper wire on surface or recess for loop earthing , including connection/ terminating with nut, bolt, spring, washer etc. as required complete all as specified & directed
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of existing lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. strip (with another copper/ GI strip base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
WELTRONENGINEERINGSERVICES (BID ID -3104604)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .