Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.7 L+₹38,480 (5.25%)Rejected-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.5 L+₹1.1 L (15.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.5 L+₹1.2 L (16.6%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
DAY TO DAY EM MAINT OF INTERNAL ELECTRIFICATIN, LIGHT FITTINGS FIXTURES ACCESSORIES AT CERTAIN OTM ACCN AT AFS MANDORE UNDER AGE EM, GE (AF) NO 02 JODHPUR
2023_MES_599938_1
8394/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (AF) No 02 Jodhpur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹20,000
Yes
27 Jul 2023
31 May 2023
28 Jun 2023
31 May 2023
26 Jun 2023
13 Jun 2023
7 Jun 2023 - 12 Jun 2023
Amount
Taking down copper/aluminium point wiring for (light, fan, bell, socket power socket etc.,)complete including fixture and fittings such as switches, sockets lamp holder bracket light fittings tube light fittings, regulators, ceiling rose , mirror light fitting , ceiling light fitting, fancy light fitting , fall ceiling light fitting bell/ buzzer and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of wall floor etc.
Taking down old U/S distribution boards complete and removing materials to store for keeping in safe custody or for taking credit.
M&L for point wiring complete with 1.5 Sqmm single core multi standard copper conductor PVC FLRS insulated unsheathed cable in and including PVC casing capping / PVC Conduit with accessories existing pressed steel terminal boxes (sunk in wall) including new 3.00 mm thick plastic laminated sheet top cover with 1.50 Sqmm insulated unsheathed PVC covered copper conductor for common earth and connecting to earth dolly for :-
One light point controlled by one, one way switch
One fan point controlled by one, one way switch
One bell point controlled by one bell push switch
One socket out let 5 Amps on the same board
One socket out 3 pin 5 Amps on the independent board.
All as per item No 3.00 here-in-before but with 2.5 Sq mm single core multi standard copper conductor cable for 6 pin 15 Amps socket out let on independent board.
S&F switch flush type 5 Amp, 240 V single pole one way ISI Marked.
S&F switch socket combination 2 in 1,5 Amps flush type
S&F switch socket combination outlet 6 pin ,6/16 Amps flush type
S&F ceiling rose, 3 Terminal Point/PVC/polycarbonate, isolated body.
S&F lamp holder, PVC /Polycarbonate type with back plate suitable for batten fitting complete with necessary wire connection etc.
M&L for sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar CL-IP-43 240 V, 8 way single pole & neutral link
All as per item No 10.00 here-in-before above but 12 way 240 V, Make : Standerd or equivalent make mentioned in appendix ‘B’.
All as per item No 10.00 here-in-before but 4 way 240 V,
M&L in replacement for MCB single pole 6-32 Amps, 240 V.
M&L in replacement for MCB single pole & neutral 32 to 63 Amps, 240 V.
M&L in replacement for MCB triple pole & neutral 63 Amps, 240 V
S&F in replacement 20 W LED batten (1.2 m) made of CRCA sheet housing with a PC glossy diffuser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified & directed. Make - Crompton Cat No LCTLN-20-WW or equivalent in Philips/Wipro.
S&F in replacement LED Recessed full it luminaire with glare free uniform illumination with longer life and less maintenances wattages in 2 ft x 2 ft not less than 100 lumen /watt, temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and as directed. Make - Crompton Cat No LCTLRNE -36-FO-CDL or equivalent in Philips/Wipro.
S&F in replacement LED Stud Bulk Head 10 watt fixture perfect interior and exterior application within car parks, walkway, stairwells, corridors, local authorities and housing association as well as commercial building including connection complete all as specified and directed by Engineer in Charge. Make – CG, cat ref no. LBHP-10-CDL or equivalent in Philips /Havells
S&F in replacement Building Security LED 45 Watt fixture made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection, commercial building including connection all as per complete all as specified and directed by Engineer in Charge. Make -Philips or equivalent in CG/ Havells.
S&F in replacement HERITAGE LED Post Ideal to light up parks, garden ways and heritage sites 20 Watts complete all as directed by Engr-in -Charge. Make :Crompton cat pat no -LPTH-20-CDL or equivalent in Havells/Bajaj
S&F in replacement of Inverted Tripod type LED bollard light 10 watt with soft light distribution complete all as directed by Engr-in -Charge Make :Crompton cat pat no -LBLSN-10-CDL or equivalent in Havells/Bajaj
NOTES FOR LED LIGHT FITTINGS & BULBS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
S&F in replacement GI Bracket for mounting street light fittings made out of light grade 32mm GI pipe and have angle of 120 degree including fixing arrangement complete all as specified and as directed by Engr-in-charge.
S&F in replacement elect bell AC 230 V single pole ISI Marked.
Taking down existing sub main wiring in casing capping/conduit pipe of any size complete.
S&F sub main wiring with 2 run of 6 Sqmm single core copper conductor cable drawn through in rigid PVC conduit ISI marked with fitting and 6.0 Sqmm single core copper conductor cable for continues earth wire all as directed.
Taking out existing earthing complete from site complete all as specified & directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick erraz directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in replacement mirror light fitting LED of 10 Watt 2 feet long complete 230V, 6000k rated CCT energy efficient with automatic ballast pen holders starters blocks, diffusers complete with all accessories including tube internally prewired and including connecting with twin core twisted flexible copper cable complete all as specified and as directed. Make -orient model no-LBLN-10-C /Bajaj/Crompton.
S&F in replacement fan electronic regulator 300w step type all as specified and as directed by Engr-in-Charge.
S&F in replacement PVC Casing/capping for electric wire installation complete all as specified and directed.
M&L for taking down ceiling fan and re-fixing the same after repair replacement of unserviceable other parts like clamps, nut, bolt, washer and locking arrangement, rubber reel, flexible wire, canopy, shaft, capacitor etc. testing complete all as specified and directed by Engineer-in Charge. Note:- (i) Replacement of unserviceable other parts like clamps, nut, bolt, washer and locking arrangement, rubber reel, flexible wire, canopy, shaft, etc. shall be inclusive in unit rate quoted. (ii) Unserviceable parts like bearing, bush and rewinding shall be measured & paid separately.
1200 mm (48") sweep.
1400 mm (56") sweep.
All as per item No. 32.00 here-in-before but exhaust fans of following sizes:-
230 mm (9") sweep
300mm (12") sweep
380/400mm (12") sweep
S&F Gun metal bush of ceiling fans any type of any sweep including cutting of grooves for fixing of bearing instead of bush any type/any size.
M&L for rewinding of burnt ceiling fan by opening covers of ceiling fan ,remove the burnt winding ,cleaning the slots and rewinding the fan with super enamelled copper wire of same wire gauge, varnishing after winding all as directed by Engineer-in-charge.
M&L of rewinding of burnt Exhaust fan motor size of 300/400 mm sweep fans by opening covers by unscrewing nuts/screws, cleaning the slots and rewinding the fan with super enamelled copper wire of same wire gauge complete call as directed by Engineer-in-charge.
S&F ball bearing of 1200 mm (48")/1400mm sweep Make: NBC/SKF/National suitable for ceiling fan.
S&F ball bearing of make: NBC/SKF/National any sweep suitable for exhaust fans/pedestal fans of any make & size.
S&F aluminum blades of 1200/1400 mm celling fans of complete all as specified and directed.
S&F oil type condenser of capacity 2.5 MFD, 230 volts AC including necessary soldering. Make : Usha/Bajaj/Unistar
All as per item No.40.00 here-in-before but capacity 4 MFD for exhaust fans/pedestal fans. Make: Jamco/GEC/Crompton
M&L for disconnecting, taking down and re-fixing the same after repair the geyser of any cap including striping, cutting the existing copper inner tank after welding, brazing and tightening the hold fast ,nuts, bolts, washer etc., complete and including making good to disturbed existing surface with plastering all as directed by Engr-in-Charge.
S&F in replacement heating element of Geysers of 2 KW rating required at site including rubber washers. Make : Theeta/ Recold/Bajaj (ISI Marked)
S&F in replacement thermostat for the Geyser of 25/50 ltr capacity ISI marked
S&F in replacement PVC heavy duty hot type connecting pieces nylon braided with brass adopters 600 mm/450 mm long and fixing in position suitable for Geyser of 25/50 Litre capacity.
S&F in replacement copper connection heavy duty hot type connecting with 02 Nos brass adopters and washer of size 600 mm/450 mm long and fixing in position suitable for geyser of 25/50 litre capacity.
S&F in replacement geyser indicator lamp square type/round type complete all as specified & directed.
Nvimal Engineers and Contractor
M/S VENUS BUILDER
Siddharth Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .