Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.5 L
EMD Value
₹2,912
Closing Date
6 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Electrification of School building old Block at HSS Nihama Kulgam
2025_PWDJK_299498_1
NIT No.Fresh/246/2025-26 Dt/30/12/2025
Open Tender
Electrical Works
Percentage
10 days
Nihama Kulgam
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹2,912
31 Dec 2025
31 Dec 2025
7 Jan 2026
31 Dec 2025
6 Jan 2026
31 Dec 2025
Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) excluding the cost of conduit.
Supply, Installation, Testing and Commissioning of 12W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro /eq. make to be approved by EIC).
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, reqd. long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete. USHA/Havells/Crompton/Phillips/bajaj/ equivalent make as directed by engineer incharge.
Supply and fixing of 6A/250 V AC fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena /eq. make to be approved by EIC).
Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required6 module (200mm x 75mm)
Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider/eq. make to be approved by EIC)
Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) excluding the cost of conduit.
Wiring for 5- 10A socket out lets for computer (inverter) with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required excluding the cost of conduit.
Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
Supply and fixing of 6 way (4+18), Double door surface/ recess mounting, Horizontal type, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB/eq. make to be approved by EIC)
Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/eq. make to be approved by EIC suitable for inductive load in the MCBdistribution board complete with necessary connections.
Supply, installation, testing and commissioning of 32A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/L&T/ABB/eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 40A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB /eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 100A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 100A 4Pole Connector inside PVC enclosure of Legrand/ Havells/ L&T/ABB/eq. make to be approved by EIC complete with necessary connections.
Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excluding the cost of conduit.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ).
2x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit
2x10 sq mm
Supplying and fixing of 25-32mm wide medium class PVC Casing Capping (channel) ( Anchor/ Ravindra/ Eq. make) along with accessories complete job.
Supply, laying, connecting and commissioning of 16 sq mm 2 core XLPE/ PVC Insulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground).
Earthing with Gl earth pipe 4.5 mtr. Long 40 mm dia. Including accessorles and providing masonry enclosure with cover plate having locking arrangements and watering pipe, trenching and filling with charcoal/coke and salt.
Providing and fixing of 25mmx5mm Gl strip on surface or in recess for extending the earthing from earth electrode to controlling panel in one rim to be laid through required dia. of PVC conduit.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.04 MB
BOQ_971616.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .