Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 CrAccepted-AOC D NO 55 41 18 1 DOCTOR S COLONY SEETHAMMADHARA VISAKHAPATNAM PIN 530013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹11.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹12.0 CrRejected-Finance MIG 2B 83 H NO 65 5 466 GULLAPALEM SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹12.0 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹12.0 CrRejected-Finance | ₹12.0 Cr | L3 | Rejected-Finance Being L3 |
| 4 | L4₹13.6 CrRejected-Finance | ₹13.6 Cr | L4 | Rejected-Finance Being L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not eeting eligibility criteria |
Tender Value
₹10.4 Cr
EMD Value
₹8.5 L
Closing Date
3 Jun 2024, 6:00 pmClosed
DDG AND CE
DGNP V Naval Base post Visakhapatnam 530014
AUGMENTATION OF ENGINEERING REPAIR FACILITY WITH ASSOCIATED WORKFLOW IMPROVEMENT MEASURES
2023_MES_628281_2
DDG CE V TOKEN 05 OF 2023 2024
Open Tender
Civil Works
730 days
VISAKHAPATNAM
As per NIT
7 documents required · 7 mandatory
₹3,000
DGNP
₹8.5 L
Yes
30 Aug 2024
6 May 2024
5 Jun 2024
6 May 2024
3 Jun 2024
20 May 2024
6 May 2024 - 15 May 2024
Amount
SCHEDULE "A" PART - I [CIVIL WORKS]
Taking down chowkats or frames not exceeding 1.5Sqm with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0Sqm with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down shutters only of any description not exceeding 1.0Sqm each, complete all as specified and as directed.
Taking down shutters only of any description exceeding 1.0Sqm but not exceeding 2.0Sqm each, complete all as specified and as directed.
Taking down shutters only of any description exceeding 2.0Sqm each, complete all as specified and as directed.
Taking down old unserviceable rolling shutter of any description and any size with all fittings, complete all as specified and as directed.
Demolition of cement concrete [unreinforced] in ground floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete [unreinforced] of any description in any position, not otherwise saperately provided for, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/loose soil, for foundation etc., or for shafts, wells, cesspits, manholes, pier holes, etc., complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in soft/loose soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance exceeding 5.0KM but not exceeding 15.0KM and depositing where directed (approved place by GVMC) at a level not exceeding 1.5m above the starting point, complete all as specified.
M&L for Moorum/Red bajri filling brought from out side MD land including filling in floors or pavings or in foundations laid in layers n.exc. 15cm thick spread, levelled and rammed including watering, complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil, including removal of the rubish outside MD land, complete all as specified and as directed by the Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30cm in depth, 1.5m in width as well as 10Sqm on plan) not exceeding 1.50 m in depth and including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as in all kind of soil, complete all as directed by Engineer-in-Charge.
Removal of excavated material [Soil] to a distance exceeding 1.5KM but not exceeding 5.0KM and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified.
M&L for Drilling or boring for 1000mm nominal dia bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials at a designated place as approved by GVMC outside MD land exc 10KM but not exc 15KM, complete all as specified and as directed.
All as per Serial Item No. 1.017 here in before but for 1000mm nominal dia through hard rock for founding depth (founding shall be as per IS), complete all as specified. Notes for Item Nos. 1.017 to 1.018:- (i) The depth of boring for piles shall be measured from existing ground level to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes. (iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in SSR Part-I specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
M&L for Cutting & Chipping of laitance concrete in piles above cut off level upto a maximum of 1m from cut off level and disposal to a distance of exc. 50m but n. exc. 250m and depositing where as directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 (using 40mm graded Granite stone aggregate) as in foundation, filling, mass concrete and underneath pile caps, suspended flooring/slab, beams, plinth protection, surface channels, drains etc. complete all as specified and as directed.
M&L for 200mm thick PCC 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in floor for ramp/platform, chequered finish, laid over and including 150mm thick PCC 1:4:8 type D2 (using 40mm graded granite stone aggregate) as in sub base, complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded hard granite stone aggregate) as in plinth protection, finished even and fair without using extra cement including making construction joints in 3metres interval and joint filled with sealing compound, complete all as specified and as directed.
M&L for Hardcore of gauge not exc. 63mm, broken stone or boulders, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
(vii) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made. (viii) Standard manufactured cover blocks as per IS should be used, Site cast cover blocks shall not be used. (ix) Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate/Lumpsum price quoted shall be deemed to include this aspect.
M&L for Reinforced Ready Mixed Cement Concrete M–40 Design Mix with admixture Auramix 400 of Fosroc or Smartcare maximo plast PX range of Asian Paints or equivalent, as in Foundations including Rafts, Footings, Foundation Beams, Plinth Beams, Bases for Columns etc., complete all as specified and as directed.
M&L for Reinforced Ready Mixed Cement Concrete M–40 Design Mix with admixture Auramix 400 of Fosroc or Smartcare maximo plast PX range of Asian Paints or equivalent, as in beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs and the like, complete all as specified and as directed.
Notes for item Nos. 1.027 and 1.028: (i) Minimum cement content shall be 400 Kg/Cu.m. of concrete for pile caps, suspended floor beams, slabs and footings, platform (Covered under item No.1.027) and cement content shall be 360 Kg/Cu.m. of concrete for M-40 using Portland slag cement with minimum slag content of 50% (fifty percent) for items covered under item No. 1.028. (ii) Design mix shall be as per IS-456-2000. Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mm to 100mm and maximum water cement ratio 0.4. (iii) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes. (iv) Reinforcement shall be measured and paid for separately. (v) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made. (vi) Standard manufactured cover blocks as per IS should be used, Site cast cover blocks shall not be used
Steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.
Steel formwork to sides of pillars, posts, struts, columns, stanchions and the like, for fair finished surfaces of concrete, complete all as specified and as directed.
All as per item No.1.030 here-in-before but to sides and soffits of floor or roof beams, cantilevers, bressummers, lintels, shelves, lintel beams, RCC bands, girders etc complete.
All as per item No.1.030 here-in-before but to fins, louvers, facia and similar articles, complete.
All as per item No.1.030 here-in-before but to sides and soffits of chajjas including supports overhangs etc., complete all as specified and as directed.
Steel formwork to sides, faces of vertical walls, water tanks, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter and the like for fair finished surfaces of concrete, complete all as specified and as directed by the Engineer-in-Charge.
Steel formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs etc. exc. 10cm but n. exc. 20cm wide for fair finished surfaces of concrete, complete all as specified and as directed.
M&L for Reinforcement using TMT CRS bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L for Reinforcement using TMT CRS bars of Grade Fe-500D of 5mm to 12mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified.
M&L for providing and installing MS liner fabricated out of plain MS plate, confirming to Fe-410-WB (Gde E-250 Quality B/BR), including rolling to required diameter welding the joints, strengthening wherever required, providing stiffeners, lifting hooks, including all T & P required, shifting the same from position to positions required, driving in true vertical alignment in position to the required level for piles, including applying one coat of primer with two coats of special bituminous paint on outer surfaces, complete all as specified and as directed. Note: MS liner shall be provided as mentioned in drawings. However, for payment purpose the depth / height of liner will be measured and paid up to cutoff level only irrespective of the depth provided for retaining concrete / bentonite slurry. The unit Rate / Lump sum price quoted shall be deemed to include for the same.
M&L for Precast cement concrete block masonry with solid blocks, using type B-1 (1:2:4), with 20mm graded stone aggregate, set in CM 1:6, complete all as specified and as directed.
M&L for Brickwork with Fly Ash Bricks, straight or curved on plan exceeding 6m mean radius, using modular bricks built in Cement Mortar 1:6, complete all as specified and directed.
M&L for Brick work using fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 including supply and fix 2 Nos of 8mm dia bars at every fourth course of brick work, complete all as specified and as directed.
M&L for Brickwork with Fly Ash Bricks, straight or curved on plan exceeding 6m mean radius, using modular bricks built in Cement Mortar 1:4, complete all as specified and directed.
M&L for PCC 1:2:4, Type B–1, using 20mm graded stone aggregate as in plinth courses, bed plates, kerbs, coping, haunching / benching etc., including necessary form work etc, complete all as specified.
M&L for Cutting into existing manholes for connecting new drains of 150mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, complete all as specified.
M&L Reinforced concrete pipes of 150mm bore, class NP2 laid and jointed and tested complete with collars, including testing, complete all as specified and as directed.
M&L for Precast Reinforced cement concrete (1:2:4), Type B-1, using 20 mm graded stone aggregate as in landings, precast cover slabs etc., set in CM 1:4, complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately.
M&L for Coloured Non skid ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exc. 0.06 Sq.m. but n. exc. 0.11 Sq.m, as in floors etc., laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed.
M&L for Coloured Non skid ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exc. 0.06 Sqm but n. exc. 0.11 Sqm, laid over and including 10mm thick backing coat in CM 1:3, set and jointed in neat cement slurry and pointed in coloured cement, as in skirting/dado etc., complete all as specified and as directed.
M&L for Machine cut kota stone slab 18-20mm thick as in floors, laid over and including 20mm thick screed bed or bedding layer in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and mirror polishing, complete all as specified and as directed.
M&L for Machine cut kota stone slab 18-20mm thick, as in vertical surfaces such as skirting/dado, laid over and including 15mm thick backing coat in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and mirror polishing, complete all as specifed and as directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and fair without using extra cement complete all as specified and as directed.
M&L for 15mm thick Rendering on fair faces of brick work or concrete surfaces in two layers as 10mm thick in cement mortar 1:6 followed by 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instructions and finish the surface even and smooth without using extra cement, complete all as specified and as directed. Note: Supply of WPC will be measured and paid separately.
M&L for Rendering 5mm thick in CM 1:3 as in ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
Supply only Integral Water Proofing Compound.
M&L for preparation of surfaces and applying three coats of white wash on newly plastered surfaces of ceilings, complete as specified and as directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over with and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, with and including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed.
M&L for applying two coats of distemper acrylic emulsion paint with and including a coat of wall care putty and priming coat of alkali resistant primer, with and including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed.
M&L for False ceiling with 6mm thick Non asbestos fibre cement building boards fixed with and including aluminium anodised snap grid of size 605mmx605mm consisting of 25X25X2mm aluminium angles and TEEs of size 25x25x2mm with galvanised wire of required length and 6mm dia GI hanger grid suspended from trusses/ ceiling and purlins not exceeding 1200mm c/c both ways, fixed to roof slab with 60mm long cleats of GI flat 40x3mm and 40mm long expansion hold fasteners 12.5mm dia, with and including applying two coats of oil bound distemper over a coat of primer, complete all as specified and as directed.
M&L for Factory made Machine pressed pre-cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thick, M-40 grade with grey cement and pigment, laid over and including 50mm thick sand filling over 150mm thick PCC 1:3:6 type C2 (using 40mm graded aggregate) as sub base over 100mm thick broken brick hard core of gauge n exc 63mm as base course, spread, levelled, rammed and watering, complete all as specified and as directed.
M&L for Precast PCC 1:2:4 type B0 (using 12.5mm graded granite stone aggregate) as in Kerb stones and the like with necessary form work and set in cement mortar 1:4, including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-In -Charge.
S&F Aluminium powder coated frame for doors, partitions, windows and ventilators with one or more rebates of extruded built up standard tubular and other section of approved make, according to IS 1868 (Thickness of powder coating not less than 50 micron) fixed with rawl plugs, screws or fixing with clamps or with expansion hold fasteners including necessary filling up of gaps of junctions at top, bottom and sides with required EPDM / PVC/neoprene gasket etc., aluminium sections should be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle, PVC/Neoprene gasket for glazing, paneling, aluminium anodised screws etc. complete all as specified and as directed.
S&F Powder coated aluminium window / ventilator shutters, side hung type without sash bars, with aluminium sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing and powder coated aluminium snap beading screws (thickness of powder coating not less than 50 micron) as per architectural drawings, complete all as specified and as directed. Note:- Only aluminium shutter for the doors/woindows/ ventilators shall be measured in sqm. All the aluminium fittings/fixtures such as butt hinges, tower bolts, handles etc, Pre-laminated particle board and sheet glass shall be measured and paid separately under relevant items
S&F Powder coated anodised aluminium decorative grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as per requirement and as directed by Engineer in-charge.
S&F Minimum 5.0mm thick sheet glass of ordinary quality of approved brand fixed in position with and including PVC/Neoprene gasket for glazing, glazing clips in doors, windows, partitions etc., as in squares not exc 0.50 Sqm in each pane etc., with all required accessories, complete all as specified and as directed by Engineer-in-charge.
S&F Minimum 5.0mm thick sheet glass of ordinary quality of approved brand fixed in position with and including PVC/Neoprene gasket for glazing, glazing clips in doors, windows, partitions etc., as in squares exceeding 0.50 Sqm in each pane etc., with all required accessories, complete all as specified and as directed by Engineer-in-charge.
S&F Solar control film 25micron reflective type sticked to glass panes, complete as per instructions of manufacturers, complete all as specified and as directed by Engineer-in-Charge.
S&F 12mm thick pre-laminated particle board, interior grade, pre-laminated on both sides with decorative choice lamination and fixed in aluminium partitions, doors shutters etc, fixed with and including 12mm thick rubber gasket, aluminium glazing clips, complete all as specified and as directed.
S&F Powder coated aluminium door shutters with aluminium sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing and powder coated aluminium snap beading screws (thickness of powder coating not less than 50 micron) as per architectural drawings, complete all as specified and as directed. Note:- Only aluminium shutter for the doors shall be measured in sqm. All the aluminium fittings/fixtures such as butt hinges, tower bolts, handles etc, Pre-laminated particle board and sheet glass shall be measured and paid separately under relevant items
S&F aluminium (die cast body) door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S&F Floor door stopper with rubber shoe 150/140mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed complete all as specified and as directed.
S&F 300mm long aluminium alloy, 16mm dia, anodised sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section and fixed, complete all as specified and as directed.
S&F Brass mortice locks, vertical type 100mm size 4 levers, complete all as specified and as directed.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel pin, anodized and fixed, type B-21 complete all as specified and as directed.
S&F 75mm size butt hinges, extruded aluminium alloy with galvanised mild steel pin, anodized and fixed, type B-21 complete all as specified and as directed.
S&F for 150mm long Extruded aluminium alloy handles with 25x3mm thick plate, fabricated type, anodised, complete all as specified and as directed.
S&F for 100mm long Extruded aluminium alloy handles with 25x3mm thick plate, fabricated type, anodised, complete all as specified and as directed.
S&F 150mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 100mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and as directed.
M&L Steel rolling shutters, gear operated type with ball bearings, bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple, 1.25mm lathe, guide channels and one shop coat of primer, including erecting in position, complete all as specified and as directed.
M&L Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50 mm x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply and fix in openings as per drawing complete all as specified and as directed by the Engineer-in-Charge
S&F Factory made solid panel PVC door shutter 30 mm thick consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame including builders hardware as per specification & drawing complete all as specified and as directed by Engineer-in-charge.
M&L Framed work such as grills, gratings, rungs etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder, framed baluster, walk ways, railings, and similar work confirming to Gde Fe-250 Quality B, complete all as specified and as directed.
M&L Framed work such as channel, angle, or tee sections, fixed independently with and including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, confirming to Fe-410-W (Gde E-250 quality A), complete all as specified and as directed.
S&F Galvanised steel water tubing 15mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid in floors and including testing, complete all as specified and as directed.
S&F Galvanised steel water tubing 20mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid in floors and including testing, complete all as specified and as directed.
S&F Galvanised steel water tubing 25mm bore dia, medium grade, conforming to IS:1239 (Part I) with and including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid in floors and including testing, complete all as specified and as directed.
S&F vitreous china Wash down water closet pan EWC (Pedestal pattern), white with 'P'or 'S' trap étc, including plastic water closet seat , closed pattern with flat bottom cover, mild steel chromium plated or aluminised hinging device, fixing bolts, etc including PVC valve less, syphonic action type low level flushing cistern 10 litres capacity, white with inlet ball valve, float and handle soft touch type including brackets, PVC flush pipe etc fixed with CP brass screws, complete all as specified and as directed. Make: JAQUAR Model No SLS-WHT 0318 or its equivalent as specified here in after.
M&L Toilet paper holder coloured of vitreous china box type fixed to walls with chromium plated brass screws, complete all as specified and as directed.
S&F ABS body Health faucet, CP with 1.2m long flexible type steel tube and wall hook, complete all as specified. Make: Jaquar Model No. ALD-573 or its equivalent as specified here in after.
S&F 250mm long aluminium alloy, 16mm dia, anodised sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section and fixed, complete all as specified and as directed.
S&F Towel rail 20mm dia, 600mm long, D type, stainless steel, chromium plated, completed all as specified. Make: Model No T6001A of Parryware or its equivalent as specified here in after.
S&F PVC connection (high density) 15mm bore 450mm with PTMT nuts both ends with rubber washer complete all as specified and as directed by Engineer-in-charge.
S&F chromium plated 15mm bore stop valves, fancy type, quarter turn, cast copper alloy, with long shank and cup (concealed), screwed down high pressure quarter turn screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer in charge.
S&F 15mm bore chromium plated pillar taps, fancy type, cast copper alloy, quarter turn, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by Engineer in charge.
S&F 15mm dia bore chromium plated bib taps, fancy type, cast copper alloy, quarter turn, screwed down screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F Powder coated aluminium window shutters, sliding type without sash bars, with aluminium sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing and powder coated aluminium snap beading screws (thickness of powder coating not less than 50 micron) as per architectural drawings, complete all as specified and as directed. Note:- Only aluminium shutter shall be measured in sqm. All the aluminium fittings/fixtures such as butt hinges, tower bolts, handles etc, Pre-laminated particle board and sheet glass shall be measured and paid separately under relevant items
Supply only Liquid Water Proofing Compound.
S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), three layered, 500 Litres capacity, hoisted and fixed in position all as specified in SSR Part I, with and including 20mm dia PTMT ball valve, complete all as specified and as directed by the Engineer-in-Charge.
S&F 40mm dia HDPE pipes fixed to walls or laid in floors as waste pipe including all fittings, complete all as specified and as directed.
S&F Vitreous china white half stall type urinal with grating and unions for discharge pipe line including 32 mm dia PVC polythene pipe of suitable length from the urinal to trap of below including necessary jointing, complete all as specified. Make: JAQUAR Model no URS-WHT 0701 or its equivalent all as specified and directed.
S&F Vitreous china wash hand basin flat back, white including brackets, cutting for and pinning in ends of brackets, 40mm dia CP brass waste fittings, complete all as specified. Make JAQUAR Model no FNS-WHT 0606 or its equivalent all as specified here in after.
S&F PVC (SWR) floor/nahani trap 100mm x 75mm size with grating including jointing to waste pipe with solvent cement, complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110mm size including jointing to waste pipe with solvent cement, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches and floors, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches and floors, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to wall with brackets, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to wall with brackets, complete all as specified and as directed.
S&F PVC (SWR) vent cowl suitable for 110mm bore pipes including jointing with solvent cement, complete all as specified.
S&F PVC (SWR) bend any radius suitable for 110mm bore pipes including jointing with solvent cement, complete all as specified.
S&F PVC (SWR) bend any radius suitable for 75mm bore pipes including jointing with solvent cement, complete all as specified.
M&L Concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid and tested, in PCC 1:3:6 type C2 using 40 mm graded aggregate for 150mm bore pipe, complete all as specified.
M&L for Coloured Glazed Ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exc. 0.06 Sq.m. but n. exc. 0.11 Sq.m, as in floors etc., laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed.
M&L for Coloured Glazed Ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exc. 0.06 Sqm but n. exc. 0.11 Sqm, laid over and including 10mm thick backing coat in CM 1:3, set and jointed in neat cement slurry and pointed in coloured cement, as in skirting/dado etc., complete all as specified and as directed.
Steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, waist slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of aluminium paint, complete all as specified and directed.
M&L for Reinforcement TMT CRS bars of Grade Fe–500D of 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M&L for applying two coats of distemper acrylic emulsion paint with and including preparation of old surfaces of any description, all as per manufacturer's instructions, complete all as specified and as directed.
M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm with and including preparation of old surfaces of any description, all as per manufacturer's instructions, complete all as specified and as directed.
Surface dressing not exceeding 15cm deep (averaging) and getting out in soft/loose soil, including removal of the rubbish to a distance exceeding 1.5KM but not exceeding 5.0KM, depositing where directed, complete all as specified and as directed by the Engineer-in-Charge.
SUB TOTAL OF SCHEDULE "A" PART - I
SCHEDULE "A" PART - II [INTERNAL ELECTRIFICATION]
Taking down carefully existing copper/aluminium point wiring with and including all fittings such as light fittings, socket, switches, ceiling roses, pendants, regulators, conduit etc., and making good disturbed surfaces of walls, floors to match with existing surface, complete all as specified.
Taking down carefully existing unserviceable DBs with MCBs, MCCBs etc., and including all fittings and making good disturbed surfaces of walls, floors to match with existing surface, complete all as specified.
Taking down carefully existing submain wiring with and including all fittings and making good disturbed surfaces of walls, floors to match with existing surface, complete all as specified.
Taking down carefully existing unserviceable light fitting of any type, including all fittings, complete all as specified.
Taking down carefully existing unserviceable exhaust / ceiling fans with and including all fittings and depositing to GE DM store yard, complete all as specified.
Taking down carefully existing unserviceable exhaust duct of any size with and including all fittings and depositing to users store yard, complete all as specified.
M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade conforming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed/surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS boxes, modular cover plates with frame for mounting modular switches thickness not less than 2mm, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan /bell point controlled by one way switch/MCB, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate.
All as per Serial Item No. 2.07 here-in-before but for light / fan point controlled by two way switch complete.
All as per Serial Item No. 2.07 here-in-before but for 3 pin 6Amp switch socket point, on same board, complete all as specified.
All as per Serial Item No. 2.07 here-in-before but for 3 pin 6Amp switch socket point, on independent board, complete all as specified.
All as per Serial Item No. 2.07 here-in-before but with 2.5Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 6/16Amp switch socket point, on independent board, complete all as specified.
S&F Modular switch 1 way 5/6A, 1 Module, 240 Volts, complete all as specified and as directed.
S&F Modular switch 1 way 15/16A, 1 Module, 240 Volts, complete all as specified and as directed.
S&F Modular Socket, 6A/16A, 2/3 pin combined multipurpose, 2 module, 240 Volts, complete all as specified and as directed.
S&F Modular Socket, 5/6A, 2/3 pin combined , 2 module, 240 Volts, complete all as specified and as directed.
S&F Modular Switch 2 way 5/6A, 1 Module, 240 volts, complete all as specified and as directed.
S&F Ceiling rose, 3 terminals PVC/Polycarbonate, 3 phase, isolated body, complete all as specified and as directed.
S&F Ceiling fan complete with blades, down rod as per site requirement to maintain 2.25m height from FFL and minimum 30cm clearance from ceiling roof, including electronic regulator step type and accessories, 230Volt, 1200mm sweep, minimum air delivery 210 CFM with service value 6.0BEE, with brushless direct current motor (BLDC), complete all as specified and as directed.
S&F Air Circulator fan 600mm sweep oscillation type of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable clamp, flexible cable suitable for 230volt, AC 50 HZ, complete all as specified and as directed.
S&F Exhaust fan, steel body, AC single phase, 230Volt, 450mm sweep, heavy duty, IP55, with blades, frame, louvers, wiremesh with all accessories and necessary PCC work, complete all as specified and as directed.
S&F Exhaust fan, steel body, AC single phase, 230Volt, 300mm sweep, heavy duty, IP 55, with blades, frame, louvers, wiremesh with all accessories and necessary PCC work, complete all as specified and as directed.
S&F of Industrial 12" portable blower fan 16" flexible duct, 2 speed, 1640 CFM, 3/8 HP, withstands - 20⁰ to 180⁰F temperature made of using durable steel housing, rubber feet on base to minimize noise and vibrations, ducting easily converts blower to an exhaust fan with convenient, flexible ducting, ducts are made with 2-ply reinforced polyvinyl, flame retardant ducts with and including quick-connect coupling for easy blower attachment, complete all as specified and as directed.
S&F LED light fitting 1 x 10w, 220volt, P.F>0.95, >100 lum/watt, bulkhead luminaries including LED light driver holder connecting with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. Make: Cat No. LBHP - 10 - CDL of CG / Cat No. LHEOALP7PZ6J010 of Havells or Equivalent make as specified here -in-after
S&F LED Building Security light fitting 40Watts, 230 volts, >100lum/W, with Suitable size GI bracket made out of 25/40mm GI pipe fixed with clamps, nuts&bolts etc., with IP 65/66 protection with LED lamp, driver, bracket with impact, corrosion resistant and all accessories, complete all as specified and as directed. Make: Cat. CIS-300-40-57-SL-DP-NGR for batten and LT8-20-865(2) for tube of Crompton or equivalent make as specified here-in-after.
S&F Energy saving, environmentally friendly & robust High bay light LED 80 Watt energy efficient fitting, P.F>0.95, >100 lum/watt, with and including LED light driver holder connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. Make: Cat No. LHELAAU7PG7S080 of Havells or Equivalent make as specified here -in-after.
S&F LED light fitting 1X20watt, 220Volt, >100 lum/W, PF>0.95, AC decorative box type with driver, holder, including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified. Make: Cat No. LHEBAAP7PW1W020 of Havells or Equivalent make as specified here -in-after
S&F LED luminaires 15 watt, 220Volt, >100 lum/W, PF>0.95, AC, round down light recessed type with high efficiency PMMA diffuser soft glare free light, complete with driver, holders & LED lamp and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified. Make: Cat No. LSCRM-15W-CDL of Crompton Greaves or Equivalent make as specified here -in-after
S&F LED highbay light fitting 200Watts, IP 66, 230 volts, >120lum/W, beam angle of ǿ 120°, AC recessed type with high Pressure Die Cast aluminum Housing and heat resistant complete with LED lamp, driver, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with all accessories, complete all as specified and as directed. Make: Cat No. CIP-326-200-57-60D-HL2-LM-NSG of Crompton Greaves or Equivalent make as specified here-in-after.
S&F Sheet metal enclosure Vertical TPN DB, 4 ways (4 incoming and 12 outgoing) with IP 54 protection, double door, sheet steel phosphetised powder painted with 200 amps rated copper busbar 415Volt, complete all as specified and as directed.
S&F Sheet metal enclosure MCB DB, double door, TPN 4 Way (8 incoming and 12 outgoing), IP-54 protection, sheet steel phospetised powder coated with 200 Amps rated copper bus bar 415 Volts, fixed in concealed position, complete all as specified and as directed.
S&F Sheet metal enclosure MCB DB, double door, TPN 6 Way (8 incoming and 18 outgoing), IP-54 protection, sheet steel phospetised powder coated with 200 Amps rated copper bus bar 415 Volts, fixed in concealed position, complete all as specified and as directed.
S&F Sheet metal enclosure MCB DB, double door, SPN 12 Way (2 incoming and 12 outgoing), IP-54 protection, sheet steel phospetised powder coated with 200 Amps rated copper bus bar 415 Volts, fixed in concealed position, complete all as specified and as directed.
S&F Sheet metal enclosure MCB DB, double door, SPN 8 Way (2 incoming and 8 outgoing), IP-54 protection, sheet steel phospetised powder coated with 200 Amps rated copper bus bar 415 Volts, fixed in concealed position, complete all as specified and as directed.
S&F Sheet metal enclosure MCB DB, double door, SPN 4 Way (2 incoming and 4 outgoing), IP-54 protection, sheet steel phospetised powder coated with 200 Amps rated copper bus bar 415 Volts, fixed in concealed position, complete all as specified and as directed.
S&F RCCB, 4Pole, 100Amp, 10kA, 415Volts, 100mA for earth leakage protection, with necessary connecting up in DB, complete all as specified and as directed.
S&F MCB TPN 100Amp, 10kA, 415Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F MCB TPN 63Amp, 10kA, 415Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F MCB TP 63Amp, 10kA, 415Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F MCCB TPN 63Amp, 16kA, 415Volt, 4 pole with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F RCCB, 4Pole, 63Amp, 10kA, 415Volts, 100mA for earth leakage protection, with necessary connecting up in DB, complete all as specified and as directed.
S&F MCB SPN 40Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F MCB SPN 10Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F MCB SP 06-40Amp, 10kA, 230Volt, C curve with necessary connecting up in MCB DB, testing and commissioning, complete all as specified and as directed.
S&F Sheet metal clad TPN enclosure with a 3 pin and earth plug & socket type, with and including one single pole MCB 20Amp, TP, 10kA, C series, 240Volt with connections, complete all as specified and as directed.
S&F Sheet metal clad TPN enclosure with a 3 pin and earth plug & socket type, with and including one single pole MCB 32Amp, TP, 10kA, C series, 240Volt with connections, complete all as specified and as directed.
S&F Sheet metal clad SPN enclosure with a 2 pin and earth plug & socket type, with and including one single pole MCB 20Amp, SP, 10kA, C series, 240Volt with connections, complete all as specified and as directed.
M&L for Circuit / Sub main wiring with two runs of 2.50Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 2.5 Sqmm as earth wire, drawn through and including rigid PVC conduit of suitable size (minimum 25mm dia), concealed /surface type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, complete all as specified and as directed.
All as per Serial Item No. 2.47 here- in-before but for two runs of 4.0Sqmm and one run of 4.0Sqmm as earth wire.
All as per Serial Item No. 2.47 here- in-before but for two runs of 6.0Sqmm and one run of 6.0Sqmm as earth wire.
All as per Serial Item No. 2.47 here- in-before but for four runs of 4.0Sqmm and one run of 4.0Sqmm as earth wire.
All as per Serial Item No. 2.47 here- in-before but for four runs of 6.0Sqmm and one run of 6.0Sqmm as earth wire.
All as per Serial Item No. 2.47 here- in-before but for four runs of 10.0Sqmm and one run of 10.0Sqmm as earth wire, complete all as specified. Note for Serial Item No. 2.47 to 2.52: Two/four runs of cable, one/two run of earth wire and one run of conduit shall be measured as one unit.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in bothways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
Design, Supply & installation of Air treatment Unit (for Pace maker 1 & 2) with pre-fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting with 18 SWG for room return air, fabricated from galvanized steel sheet, having zinc coating of 120 gm/sqm total on both sides, including all accessories such as hangers, supports, Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc., all as per IS: 655:1963 with required scaffolding work to install the ducts at site, complete all as specified and as directed.
M&L for Flame proof point wiring with 2.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade conforming to IS 694: 1977, drawn in and including stove enamelled steel conduit not less than 20mm bore, concealed / surface type, medium grade with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS boxes, modular cover plates with frame for mounting modular switches, including one run of 2.5 Sq.mm single core FRLSH PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan / socket point controlled by one one way switch, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate.
S&F Flame proof switch socket & plug combined in LM 6 cable termination box in LM6, 16Amp, 250Volt, double pole, complete all as specified.
S&F Flame proof exhaust fan, steel body, AC single phase, 230Volt, 450mm sweep, heavy duty with blades, frame, louvers, wiremesh epoxy powder coated finish, with all accessories and necessary PCC work, complete all as specified and as directed.
S&F Flame proof DB, double door, single pole and neutral 08 Way sheet steel phospetised powder coated with 200 Amps rated copper bus bar 240 Volts neutral link, with cast aluminium alloy LM-6 construction with IP-66 protection, fixed in concealed position, with and including one MCB SPN 63Amp, 10kA, C curve & one MCB SP 6-32Amp, 10kA, C curve, with internal & external earthing SS hardware, rotary type switch 6Amp in LM6 termination box, complete all as specified and as directed.
S&F Flame proof LED CLEAN ROOM light fitting 45Watt, High effciency long life LED with lumen efficiency of 120 lum/W, powered by an inetgaral isolated low THD electonic LED driver (SMPS based constant curent supply) with output short circuit protection, surge protection, wheather proof-IP66 degree of protection as per IEC 60529(2001), cast aluminium alloy LM6, outside light grey epoxy powder coating finish, neoprene rubber gasket stainless steel hardware with mounting arrangement, flat heat resistant clear toughened glass type-A, with glass opening of size 400mmx150mm with all accessories, complete all as specified and as directed.
Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 3.0core x 4.00Sqmm, with stranded copper conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified.
SUB TOTAL OF SCHEDULE "A" PART - II
SCHEDULE "A" PART - III [EXTERNAL ELECTRIFICATION]
Supply, installation, testing & commissioning of copper wound step down transformer, outdoor type complete with standard fittings, 3 phase, 1000KVA, 11/0.433KV, Dyn 11", OCTC (+7.5% to -7.5%@ 2.5%) natural ester oil cooled transformers, temp rise, impedance and losses shall conform to IS 1180- level III, radiators shall be hot dip galvanized (HDG) to avoid corrosion. HV cable box and LV cable box as per specifications, with and including civil foundation, fencing, aggregates filling and necessary safety arrangements as per OEM recommendations, complete all as specified and as directed. Notes: (i) Drawings shall be approved by Garrison Engineer. (ii) Foundation shall be as per manufacturers recommendation. (iii) The two winding power transformer shall be natural oil immersed conforming to IS-1180, Level-III and IEC-62770 standard for natural ester oil filled transformer. The equipment shall conform to latest applicable standards as follows: (a) IS:2026 for tests and tolerance on guaranteed particulars. (b) IS: 1180 for Losses and Impedance. (c) IS:3639 for fittings and accessories (d) IS : 2099 for bushing > 1000V (e) IS:7421 for bushing <1000V.
(f) IS:1271 for electrical insulation classified by thermal stability. Terminal Arrangement: (a) HV & LV Side: Cable Box (b) Quad fabricating cable box with five compression glands for PVC cable and one additional neutral terminal shall be bought out separately for earthing purpose on LV Side. (c) First filling of new transformer oil [IS-335 Marked]. filtered and tested up to 50 KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the contractor after filling the oil. (d) Transformer name plate shall be engraved with type of winding as "Copper" and winding mass separately.
Supply, laying, testing and commissioning of HT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 3.0core x 120.00Sqmm, with stranded aluminium conductor, 11000 volts grade, suitable for earthed system with and including connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified.
Supply, laying, testing and commissioning of HT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 3.0core x 240.00Sqmm, with stranded aluminium conductor, 11000 volts grade, suitable for earthed system with and including connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified.
S&F Touch proof Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm, complete all as specified.
S&F Touch proof Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm, complete all as specified.
S&F Touch proof Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm, complete all as specified.
Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric FR power cable [heavy duty] of size 4.0core x 16.00Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified.
Description all as per Serial Item No 3.07 here-in-before but for cable of size 4.0core x 10.00Sqmm
Description all as per Serial Item No 3.07 here-in-before but for cable of size 3.5core x 500.00Sqmm
Description all as per Serial Item No 3.07 here-in-before but for cable of size 3.5core x 400.00Sqmm
Description all as per Serial Item No 3.07 here-in-before but for cable of size 3.5core x 120.00Sqmm
Description all as per Serial Item No 3.07 here-in-before but for cable of size 3.5core x 70.00Sqmm
S&F Hot dipped Galvanised GI perforated cable tray of size 1000mm width x 100mm depth x 2mm thick, perforation not more than 17.5%, box type with cover and necessary bends, tees, angles, suspenders, supports for fixing etc., complete all as specified and as directed.
M&L for Dry river sand cushioning over and around the cable for cable protection in trenches, leveled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
M&L for Un-reinforced Precast Cement Concrete Cable Covers, Class LV, Type - 1 flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and as directed.
M&L for Un-reinforced Precast Cement Concrete Cable Covers, Class HV, Type - 1 flat, size 300mm X 180mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and as directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS. clamps, bolts and nuts of approved size, for HT 25x20cm, complete all as specified.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS. clamps, bolts and nuts of approved size, for LT, 20x15cm complete all as specified.
S&F Synthetic rubber insulating Mat of size 2.0m x 1.0m x 2.5mm thick, for electrical purpose as per IS 15652-2006, suitable for voltage upto 11KV, complete all as specified and as directed.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with and including HDPE pipe of 150mm bore of pipe suitable for 6 kgf/Sq.cm working pressure, complete all as specified and as directed.
M&L for RCC (M25) Cable route indicator of size 800mm x 400mm x 100mm thick, minimum 500mm height above GL, duly painted with two coats of super enamel yellow colour over a coat of primer, duly marked with red colour words such as HT 11KV / LT Cable 1.1KV cables as directed with and including grouting in PCC 1:2:4 (Type B1), necessary earthwork, complete all as specified and directed.
M&L for Earthing complete with Copper earth plate electrode 60cm X 60cm X 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 32mm bore GI pipe medium grade for GI wire protection and 32mmx6mm copper earth strip, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
S&F LED Building Security light fitting 150Watts, 230 volts, >100lum/W, with Suitable size GI bracket made out of 40mm GI pipe fixed with3Nos of clamps with nuts & bolts etc., complete with IP 65/66 protection with LED lamp, driver, bracket with impact and corrosion resistant and all accessories, complete all as specified and as directed. Make Cat No. ENDURAPEARL PLUSS L 150W LED 757 PASYTOPCLC of Havells or equivalent make as specified here-in-after.
Item No. 3.24 Contd.., Outgoing: (a) ACB 1000Amp, 4pole, 65kA, 415V, 50Hz with thermal magnetic release, MDO - 02 Nos (b) MCCB 630Amps, 4Pole, 50kA,415Volts with microprocessor release - 01No.
Supply, Installation, testing & commissioning of fully type tested HT 11kV, 25kA, VCB panel consisting of 01No HT VCB 630Amp, 11KV as incoming and 02No HT VCB 630Amp, 11KV as outgoing VCB, outdoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanishm suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, self supported insulated busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel construction with Aluminum Zinc not less that 3mm thickness for load bearing section and not less than 2mm thickness for non-load bearing and shall be totally dust and vermin proof, VCB panel conforming to IEC 62271-200 standards and IP 65 class of protection comprising necessary bus bars extension and connections and following protective and control devices as specified below. Circuit breakers shall be suitable for E2, M2, C2 duty, Vacuum interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the vacuum interrupter. Relay Panels shall have built in feature of condition, Thermal Environmental & Circuit Breaker Monitoring along with HMI as per specifications. The switch gear and control gear panels shall be of the fully arc proof for 25kA for 1 Sec, complete with the following:- Incoming Panel: 11kV 630Amps, 25kA for 3 Sec HT vacuum circuit breaker of outgoing conforming to the IEC 62271-200 - 1Nos with following accessories:
ii. Relay shall have web server (web HMI) feature to monitor and control using LAN. iii. Relay shall support customer defined programmable logic. iv. Relay shall have minimum 8 programmable LED. v. Phase over current (50/51), Directional phase over current (67), STOP switch on to fault (50HS), current unbalance (46), Thermal overload (49), Earth fault (50N/51N), Directional Earth fault (67N), Under voltage (27), over voltage (59), Zero sequence voltage protection (59 N), Frequency (81), Directional Power (32). auto reclose (79), circuit breaker failure (50BP), cold load pickup and magnetizing inrush, programmable stages(99), syncro check (25), CB wear. vi. The relay shall have 4CT and 4VT inputs. vii. The relay shall be provided with at least 16 digital inputs and 8 digital outputs and one self-supervision output. k. Master trip relay with Remote Reset - 1 No l. Trip circuit Supervision Relay - 1 No. or inbuilt in the main protection relay. m. High speed master trip relay. n. Air insulated rear end bottom entry cable box suitable for termination of XLPE cables. i. Spring charging handle. ii. Fully internal Arc tested for 25kA for 1 sec. iii. Manual closing/tripping of the CB with compartment door closed. iv. Short time rating for 3 Seconds as per IEC 62271.100 v. Mechanical endurance test - M2.
o. Breaker shall be provided with following features. i. Auxiliary switch 6 NO + 6NC contacts mounted on the draw out portion of the switchgear. ii. Position cell switch with 3NO + 1NC contact one each for test position and service position. p. Temperature sensor type TH110 or equivalent for cable & busbar chamber. q. 1 No. humidity sensor type CL110 or equivalent Outgoing Panel: 11kV 630Amps, 25kA for 3 Sec HT vacuum circuit breaker of outgoing conforming to the IEC 62271-200-2Nos with following accessories: a. 630 Amps Continuous high conductivity electrolytic copper bus bar of capacity as specified and for full voltage, phase identification made at the end by colored tape, bus bar shall be mounted on integral seal off bushing and interconnection with electrolytic grade copper with joints silver plated. b. Circuit breaker shall be mounted on withdrawable truck which shall roll out horizontally from service position to isolated position with ease. c. Motorized spring charged mechanism. d. Current transformer Indoor Single Phase Resin cast Ratio: 200-100/1-1A Core-1: 15VA class 0.5, Core - 2+B231:B232 15VA 5P10
h. Master trip relay with Remote Reset - 1 No i. Trip circuit Supervision Relay - 1 No. or inbuilt in the main protection relay and High speed master trip relay. j. PT Fuse failure shall be inbuilt in the main protection relay . k. Transformer fault alarm/ trip aux. relay for transformer feeder only. l. 8 window Annunciator with Hooter. m. Air insulated rear end bottom entry cable box suitable for termination of XLPE cables. i. Spring charging handle. ii. Fully internal Arc tested for 25kA for 1 sec. iii. Manual closing/tripping of the CB with compartment door closed. iv. Short time rating for 3 Seconds as per IEC 62271-100 v. Mechanical endurance test - M2. n. Breaker shall be provided with following features. i. Auxiliary switch 6 NO + 6NC contacts mounted on the draw out portion of the switchgear. ii. Position cell switch with 3NO + 1NC contact one each for test position and service position. o. Temperature sensor type TH110 or equivalent for cable & busbar chamber. p. 1 No. humidity sensor type CL110 or equivalent. q. EARTHING TRUCK FOR 11 KV:Bus side earthing truck - 01 No and cable side earthing truck - 01 No.
SUB TOTAL OF SCHEDULE "A" PART - III
SCHEDULE "A" PART - IV [FIRE ALARM AND FIRE DETECTION SYSTEM]
S&F Dry chemical powder extinguishers, 6Kg capacity, complete with intial charge, gun metal cap, discharge hose with nozzle wall fixing brackets etc., conforming to IS : 15683 with ISI mark, complete all as specified and as directed.
S&F CO2 fire extinguishers - 4.5 Kg capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets etc conforming to IS : 15683 with ISI mark, complete all as specified and as directed.
Supply installation and commissioning of repeater alarm panel for fire detection and alarm system suitable for GSM/GPRS/ necessary SCADA software complete all as specified and directed.
Supply and fixing of addressable dual action manual pull station- single action connected with back box, complete all as specified and as directed.
Supply and fixing loop sounder visual indicator controlled by full core protocol with fire control panel programme accordingly complete all as specified and as directed.
Item No. 4.07 Contd.., provision of CMS/ AD-NET software- to monitor and control the status of FACP from the window based system- with visual and sound alerts for the fire and faults conditions with three level multi user access, provision of protective cover, complete all as specified. Note: The rate quoted includes the followings:- 1. Supply and installation of 24V fault torrent network card with built in diagnostics and is fully monitored for both sort and open circuits between notes (To be installed in fire alarm panel) the maximum No network node is 200. 2. Fire detection and alarm system are to be connected with auto dialler for easy communication with pre recorded massage to stored phone numbers. - 01 set 3. Fire alarm panel is to be secured with suitable non conductive wooden with mica finish to protect from tempering. 4. All fire system should be distributed in Zones.
M&L for PVC insulated, Unsheathed, multistranded copper conductor armoured cable of size 2 core x 1.5 sqmm, 1100 Volts, FRLS Grade, ISI marked, drawn through and including heavy duty PVC conduit of suitable size with all accessories concealed, including all fittings, complete all as specified.
S&F TCP/ IP module (Ethernet Module) HiRS-485-module to provide communication between local network that uses the RJ45 communications protocol (TCP server & UDP) and fire alarm control Panel, complete all as specified.
S&F Addressable mini monitor module with back box for manual pull station, complete all as specified.
S&F Addressable control module for monitoring the field devices, complete all as specified.
S&F Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, complete all as specified.
S&F replay module capable of connecting fire fighting/ gases release panel along with integration, complete all as specified.
S&F of Multisensory detector comprises optical smoke and thermistor temperature sensors which give both a combined signal as well as a separate heat signal for improved false along with isolator modules as required. Positioning of multi sensor detectors complete all as specified and as directed. Operating voltage: 17-28V DC, Communications protocol: Honeywell / Notifier / Apollo / Series 90/XP95 5-9V peak to peak, Quiescent current: 500mµ peak Power-up surge current : 1mA, Maximum power-up time : 10s, Alarm LED current : 3.5 mA, Remote LED current : 4mA at 5V (measured across remote load), Clean level analogue value : 23 + 4/-0, Alarm level analogue value : 55 Alarm indicator : 2 Colourless light Emitting Diodes LEDs; illuminated red in alarm Optional remote LED, Dimensions: 100mm diameter 50mm height 58mm (height in base), Weight : Detector: 105g Detector in base: 160g Materials : Housing: White polycarbonate V-0 rated to UL94 Terminals : Nickel plated stainless steel smoke element only : Chamber configuration : Horizontal optical bench housing infra-red emitter and sensor, arrange radially to detect forward scattered light Sensor: Silicon PIN photo-diode complete all as specified and as directed.
Supply and installation of CMS software to monitor & control the status of the FACP from the windows based system with visual and sound alerts for the fire and fault conditions with three level multi users access, complete all as specified.
SUB TOTAL OF SCHEDULE "A" PART - IV
SCHEDULE "A" PART - V [REFRIGERATION & AIR CONDITIONING]
Supply, fixing and installation of Invertor type split AC [Indoor and Out door units] of capacity 2.0TR with in-built ioniser and plasma filter for better indoor air quality, with R-410A and minimum 5 star energy rating and EER 3.2, fixed with and including out door stand/brackets, copper condenser tubes, drain pipe, including drilling holes and making good the disturbed surface, with cordless remote control unit and testing on completion, complete all as specified and as directed.
S&F Voltage stabilizer 5KVA for automatic operation, three phase naturally air cooled indoor type and designed for input variation 340Volt to 460Volt, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
Supply, installation, commissioning of Water cooler electric driven (Single phase), fully stainless steel body having approx storage capacity of 120 litres nominal cooling capacity of 60 Litres per hour, using green refrigerant R134A having 2 nos faucets, complete all as specified and as directed.
M&L for Cutting existing CI/DI/GI pipes upto 200mm and reducing to required length in position with and including insertion of new tees, branches, etc., as required at site, and making good, complete all as specified and as directed.
S&F Galvanised steel water tubing 80mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, complete all as specified and as directed.
S&F Galvanised steel water tubing 50mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, complete all as specified and as directed.
S&F Galvanised steel water tubing 25mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, complete all as specified and as directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends, suitable for iron pipe of 50mm bore, complete all as specified and as directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends, suitable for iron pipe of 25mm bore, complete all as specified and as directed.
S&F Cast Iron Sluice valve suitable for 80mm bore pipe, conforming to IS:14846 or latest, flanged of class PN 1.6, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
M&L for DI Specials such as Bends , tapers any type, Tee pieces, single branch, "Y" junction, double branch, cross, collars, caps and plugs for connecting up to 150mm bore DI Pipe all as per IS:9523, complete all as specified and as directed. Note: Fittings shall be conforming to IS 9523:2000.
Design, supply, installation, testing and commissioning of water cooled screw chiller type compressor, Central A/C plant complete with all equipments and accessories of nominal capacity 3 x 160 TR each (Two Number working and one number standby), complete including all accessories all as specified and directed. Note:- Complete design of chilled water plant along with necessary calculations, duly depicting the components mentioned at particular specifications will be submitted by the contractor for approval of the Accepting Officer. A single line Diagram will also be submitted along with design for approval of the Accepting Officer. (a) CHILLER PACKAGE UNIT:- Micro processor controlled, factory assembled and factory tested water cooled Chiller package comprising of semi hermeticcally sealed screw type compressor using HFC-134-A/HFC-410-A/HFC-407-C of zero ozone depletion potential in single refrigeration circuits, Refrigerant driven with 2-pole squirrel cage induction motor 3 Phase 415V suitable for min 160 TR refrigeration capacity, water cooled condenser and DX cooler with thermostatic expansion valve complete with inbuilt control panel having microprocessor based control for operation of compressor, condenser, chillers having features of auto operation, min run time equalization, auto restart after power failure, built in time delay, fault diagnostic etc, complete with suitable capacity contactors duly pre wired and inter connected - 03 Nos.(2 working + 1 standby)
(b) CONDENSER WATER CIRCULATION SYSTEM:- comprising of the following :- (i) FRP induced draft cooling tower two in Nos of capacity: 800USGPM of above working plant capacity, complete installed on suitable RCC staging including PCC flooring in around the staging with spray section, honeycomb fill basin, fan, TEFC Motor, intake bird screen and other accessories (as per manufacturers tech specifications ) -02 Nos (Both will be working same time) (ii) PVC/HDPE make up water tank of 2Nos x 5000 ltr capacity each installed / placed on PCC/Brick staging/RCC of suitable load carrying capacity platform for makeup water requirement including brass float valve with polyethylene ball, over flow and drain arrangement incoming connection of GI pipe 25 mm dia medium grade from tank to tapping point - 01 Job. (iii) Energy efficient mono block type 3 phase electric driven pump sets working on 415V AC for re-circulation of chilled water of 100% plant capacity-03 Nos (02 working & 1 No standby) - 560 USGPM / 20 MTR HEAD- CONDENSER WATER (iv) condenser water piping of MS ERW Class 'B' of size 250 mm NB, 200 mm NB, 125mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden/Puff blocks, etc. as specified for interconnecting the cooling tower with condensers and pumps, make up water tank, drain pipe, complete with Y strainer, NRVs and butterfly valves - 01 Job. (v) Non chemical type on line scale preventer of size 250 mm as per the capacity of the condenser water pump flow all as specified - 2 Nos
(c) CHILLED WATER CIRCULATION SYSTEM :- Comprising of the following :- (i) Energy efficient mono block type 3 phase electric driven pump sets working on 415V AC for re-circulation of chilled water of 100% plant capacity-03 Nos (02 Nos working and 1 No standby) - 400 USGPM / 30 MTR HEAD- CHILLED WATER with ribbed rubber vibration isolation pads. Necessary pressure gauges on discharge of pump shall be provided at outlet of each pump- 03 Nos. (ii) chilled water piping of MS ERW Class 'B' of size 150mm NB, 100mm NB, 80mm NB with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, butterfly valve, NRV, Y-strainer etc. for interconnecting and thermally insulated with 75 MM thick EPS Pipe Section covered with 26 G Aluminium cladding all as specified including water flow switches and electrically operated modulating valve at each AHU - 01 Job with provision of connecting external/mobile chiller unit. (iii) Expansion tank of 2000 ltrs capacity made out of minimum 6mm thick MS sheet including connections and insulation with 50mm thick fibre glass wool covered with chicken wire mesh of density of 24 kg/cum finished with sand cement plaster including civil works and painting with 3 coats of cement based paint and epoxy paint and necessary piping, control valves on inlets and wash out, float valve etc -01 Job.
(d) AIR TREATMENT SYSTEM :- Comprising of the following:- (i) OUTDOOR AIR HANDLING UNIT (AHU):- Supply, installation, testing and commissioning of Double-skin type horizontal, floor-mounted, top/side discharge air handling units having corrossion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 43 mm double skin panel with pressure injected CFC & HCFC free PUF with 'k' value of 0.02 W/°C m & density 40 kg/cum, pre-coated pre-plasticized galvanized outer and inner skin 0.60mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward or backward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, chilled water coils with combination of 6 rows deep with anti-corrosion Aluminum fins, PVC Nylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers. Canopy for the AHU suitable for outdoor application. [a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc.
[e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/sq cm with SS sandwiched drain tray, etc. Capacity 80 TR-32000 CFM (Apx) - 04 Nos Heater Bank ( 18 KW ) (Apx) - 04 Nos [f] 3-way mixing valve of size 80mm NB, suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete with elastomeric thermal insulation of suitable thickness all as specified - 4 Nos [g] CL 150 rated ball valve of size 25mm NB, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fasteners and lever and screwed/socket weld end connection, etc. with accessories all as specified - 12 Nos
[h] Automatic air-vent valve having 19mm end connections with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air, complete all as specified - 10 Nos [j] Temperature gauge of 100 mm dia for temperature range 0°C to 100°C of glycerin filled bimetallic thermometer in compliance to EN 13190, having standard range 0°C to 60°C up to 400°C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc all as specified - 34 Nos [k] Pressure gauge of 100mm dia size for pressure range 0 psi to 200 psi of glycerin filled pressure gauge in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. all as specified - 20 Nos
Under deck insulation for outdoor type AHUs & Sun exposed slabs with Fire Retardant XPE closed cell of thickness 18mm with metalized polyester film and self adhesive backing with protection peel off paper. Removable supply air [SA] diffusers/grills with Damper of extruded aluminium sections duly powder coated with volume control damper, Removable Return air [RA] diffusers/grills of extruded aluminium sections duly powder coated with volume control damper, 18G galvanized sheet steel volume control duct damper, fresh air damper with GI bowl/ fittings and mosquito proof netting shall be provided for each AHU Room, complete all as specified and as directed. (f) ELECTRICAL DISTRIBUTION SYSTEM:- Comprising of the following:- (i) AC Plant Electrical panel board, Cubical type, floor mounted, vermi proof, dust proof CPRI approved, Indoor type, Powder Coated with seven tank process switch board panel made out of MS sheet not less than 16 SWG powder coated paint suitable for operation on 415 volt of 50 Hz AC supply internally wired with copper conductor wire, comprising of the following: (aa) Air insulated Aluminim bus bar of adequate size for phase and neutral. (ab) Main Incoming ACB and outgoing MCCBs of adequate capacity for chilled water pump sets, AHU blower motors, condenser, condenser fans. (ac) one digital electronic energy meter of suitable capacity.
(ad) Suitable capacity capacitor to be provided to maintain power factor minimum 0.98. The panel shall be designed and wired in such a manner that the starter for condenser water pump is powered first, after that the cooling tower motor shall be powered, then the chilled water pumps shall be powered and then chiller units should get the supply only if the condenser water pumps, cooling tower motor, and chilled water pumps are in ON condition. OUT GOINGS: for Chiller : 180 Amps, Four Pole MCCB -4 Nos, (3 W + 1 SB) for Cooling Tower: 63 Amps, Four Pole MCCB-3 Nos, (2 W+1 SB) for Pumps: 40 Amps, Four Pole MCCB-8 Nos, (6 W+2 SB) for AHU 11 KW - 40 Amps, Four Pole MCCB- 5 Nos (4 W+1 S) for Heater Bank : 18 KW 63 Amps, Four Pole MCCB - 5 No (4 W+1 S) (ii) AHU sub panel board of suitable size, factory made, CPRI type tested, outdoor type, 3.15 mm thick CRCA duly powder coated in compartmentalized construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, Heater Bank/Pan Humidifier, fire damper actuator motor, with required variable frequency drive, relays, timers, contactors, PT, push buttons, switches, internal wiring, etc., for 11KW AHU electrical panels - 04Nos
(18) The contractor shall visit the site, prepare and produce the actual heat load calculations to arrive at the actual capacity of the AC plant and connected accessories to the GE. (19) The tenderer need to submit the drawings for chiller units, AHUs, electrical panel etc., including all major components for approval of the Accepting Officer through GE before placing the order. The contractor should submit all the supporting caculations as well as OEM recommendations for all the motors, pumps, AHUs, cooling towers, De-humidifiers etc., to get the decide conditions in the specified space. (20) The inside design conditions required is temp 23 degree centigrade + OR - 2 degree centigrade, and relative humidity is 55% + or - 5%. (21) Plant room will be provided with necessary safety protection guidelines and SLD layout of complete chiller plant with all accessories.
SUB TOTAL OF SCHEDULE "A" PART - V
SRI SURYA PROJECTS
COMPRESSORS & CONTROLS
K KUMAR RAJA PROJECTS P LIMITED
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid