Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC AVAS VIKAS NANDANPURA JHANSI UP 284003 | JHANSI | UTTAR PRADESH | 284003 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹48.9 L+₹1.4 L (2.95%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹50.2 L+₹2.6 L (5.55%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹50.3 L+₹2.8 L (5.94%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹51.0 L+₹3.5 L (7.41%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
20 Jan 2024, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
REPAIR/REPLACEMENT OF INTERNAL WIRING, LIGHT FITTINGS, SWITCH GEARS, AND OTHER ALLIED WORKS FOR MD ACCN AND OTM ACCN AT NAA UNDER GE (N) TEZPUR
2024_MES_635590_1
GE(N)/TEZ/2023-2024/8792
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (NORTH) TEZPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹96,000
14 Feb 2024
3 Jan 2024
22 Jan 2024
3 Jan 2024
20 Jan 2024
15 Jan 2024
Amount
Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point or buzzer controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc complete all as specified and as directed.
M & L for point wiring with 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25/32 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, PVC terminal box and PVC board making good disturbed surface to match with the existing surface for one light /fan/bell point controlled by one switch complete all as directed by Engineer-In-charge.
All as per item 2.0 above but for One 3 pin socket outlet 5 Amps on same board complete all as specified and as directed.
All as per item 2.0 above but for One 3 pin socket outlet 5 Amps on indpendent board complete all as specified and as directed.
All as per item No.2.0 above but with 2.5 sqmm single core multistranded copper conductor FRLSH cable for 3/5 pin 5/15 Amp socket outlet on independent board complete all as specified and as directed.
S&F in replacement switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed.
S&F in replacement of switch socket combination 2 in one, 5 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
S&F in replacement of switch socket combination 2 in One , 5/6 pin, 5/6/16 Amps flush type complete all as specified and directed.
S & F in replacement of socket out let, 5 pin 5 Amps flush type complete all as specified and directed.
S & F in replacement of ceiling rose polycarbonate type three terminals complete all as specified and directed.
S & F in replacement LED bulb of 10W with Lumen output 950 lm and Colour Temp 6500K B22 type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed.
S&F in replacement LED bulb of 7 W with Lumen output 950 lm and Colour Temp 6500K B22 type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed.
S&F in replacement LED Tube light luminaires, 20-22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of from connector and ceiling rose, complete all as specified and directed.
S&F in replacement mirror light batten type 11 W 230V AC, 50Hz, Pf >0.98, THD <10% on wall complete all as specified and directed by Engineer in charge.
S&F in replacement of LED bulk head wall light fixture 6 Watt , pressure die cast housing , IP 66 protection and IK 09 impact resistance suitable for surface and wall mounting complete all as specified and as directed.
S & F in replacement LED recess mounted (2'x2' size flat panel) luminaire which provide soft light and glare free symmertical illumination suitable for armstrong/grid ceiling of 36Watt,(Lumen output not lessthan 3600) complete all as specified and directed.
S&F in replacement LED tube rod 18 W with high efficacy, lumen output not lessthan 105 lm/W (4 feet), made of crystal glass, high lumen output, and operated in single phase, 230 volts, 50HZ, suited for installation in existing tubelight luminaire with G13 lamp holders complete all as specified and directed.
S&F in replacement ultra bright LED PLL with high efficacy 18 W operated in single phase, 230 volts, 50HZ, suited for installation in existing 2G11 lamp holders complete all as specified and directed.
S&F in replacement new generation energy saving and environmental friendly long life 15 W LED wall/building security light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed .
S & F in replacement new generation energy saving and environmental friendly long life 25W LED wall street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed.
Supply and fix electric water heater storage type steel/thermoplastic polymer body(as directed by Engineer-In-charge) with stainless inner tank capacity 25 litres, heating element of 2 KW, BEE 5 star rated with all accessories such as safety valve , thermostat , NRV , connection pipe , nut bolt with metalic anchor fasterner etc for fixing on wall & testing complete all as specified and directed by Engineer-In-charge. Note:1. Warranty of 2 year on geyser and 07 year on geyser tank shall be submitted by the contractor. 2. Old unserviceable Geyser to be deposited to MES store yard.
Supply and fix electric water heater storage type steel/thermoplastic polymer body(as directed by Engineer-In-charge) with stainless inner tank capacity 50 litres, heating element of 2 KW, BEE 5 star rated with all accessories such as safety valve , thermostat , NRV , connection pipe , nut bolt with metalic anchor fasterner etc for fixing on wall & testing complete all as specified and directed by Engineer-In-charge. Note:1. Warranty of 2 year on geyser and 07 year on geyser tank shall be submitted by the contractor. 2. Old unserviceable Geyser to be deposited to MES store yard.
Taking down burnt/unserviceable sub main wiring any size complete and making good disturbed surfaces of walls all as specified and directed.
Supply and draw submain wiring with two single core 4 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor on wall surface PVC casing caping medium grade of 20-25 mm wide, with double locking type including 4 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC casing caping on walls and making good disturbed wall surfaces matching with the existing shade / tint are deemed to be included in the rates quoted.
Supply and draw submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor on wall surface PVC casing caping medium grade of 20-25 mm wide, with double locking type including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete. Note:- Cost of PVC casing caping on walls and making good disturbed wall surfaces matching with the existing shade / tint are deemed to be included in the rates quoted.
M&L for sub main wiring with three single core 10 Sqmm FRLSH copper conductor cable PVC insulated and unsheathed stranded incl drawing through concealed on wall surface PVC casing caping medium grade of 20-25 mm wide, with double locking type with all accessories like bend,Tee , junction incl 01x 10 Sqmm FRLSH PVC insulated unsheathed copper conductor cable as earth wire all as specified Note- Three run of 10 sq mm and one run of 10 sq mm PVC insulated copper wire and one run of PVC casing caping shall be measured as one unit
Taking down main switches and DBs of any type and make including wooden board/ junction box and making good disturbed surfaces of wall , floor etc complete all as specified and as directed.
Supply and fixing single pole and neutral enclouser with a two pin and earth plug and socket complete with one pole MCB 20 Amps complete all as spd and directed.
S & F sheet metal enclosure double door for MCB DBs SPN 8 way 240 V, complete flush mounted all as specified and as directed.
M&L for sheet metal enclosure MCB DBs SPN , 12 way 240 V, with 100 A rated bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed.
M&L for sheet metal enclosure for Ekinox TPN DB-VTPN 4 way 415 V, double door , 200 A copper bus bar , IP 43 , including 125 Amp MCCB as incomer as flush mounted complete all as specified and as directed.
M&L for sheet metal enclosure for Ekinox TPN DB-VTPN 4 way 415 V, double door , 200 A copper bus bar , IP 43 , including 63 Amp MCCB as incomer as flush mounted complete all as specified and as directed.
M&L for sheet metal enclosure TPN DB- 4 way 415 V, double door , 100 A copper bus bar , IP 43 , MCB as incomer as flush mounted complete all as specified and as directed.
S&F MCB single pole (SP) 40 Amps, 240 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed.
S&F MCB DP 40 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed.
S&F MCB 4 Pole 63 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed.
S&F MCB 4 Pole 40 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 15 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as shown on electrical plate No. 3 of SSR part - I , including taking out old U/s complete alll as specified and directed .
PURBANCHAL BUILDERS
Purbanchal Construction Co
HEMONTA DAS
SONI ENTERPRISE
Sibson Constructions And Co
M/S MOHANPASARI
D G Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .