Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
4 Jul 2022, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Special repairs/replacement of internal and external electrification of X Ray department of 150 GH and certain sanctioned work at Rajouri under GE 862 EWS
2022_MES_528467_1
GER-22/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹72,000
Yes
5 Aug 2022
4 Jun 2022
6 Jul 2022
4 Jun 2022
4 Jul 2022
21 Jun 2022
Amount
Sch 'A' Part-I (B/R works) Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness (below or above the ground level ) complete all as specified and directed.
M&L for plain cement concrete type B-1 (1:2:4), (using 20 mm graded stone aggregates) in surface channels and drains complete all as specified and directed.
M&L for formwork to edges of concrete flats, breaks in floor, opening in concrete walls, floors and roof and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 20cm wide with rough finished surfaces of concrete complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed. (Note:- Inner girth only measured)
M&L for pre-cast cement concrete type B-1, 1:2:4 ( using 20mm graded stone aggregate) as in manholes cover set in cement moter (1:6) complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer including preparing surface of cement base even and smooth with wall care putty complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick/concrete surfaces using water proofing compound as per manufacturers instruction, finished even and smooth without using extra cement complete all as specified and directed. (Cost of the water proofing compound included this item).
M&L for glazed ceramic coloured tiles of size 350x 250x7mm or 450x350x7mm thick, (premium quality) on vertical surface such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10 mm thick backing layer of cement plaster in cement mortar (1:4) complete all as specified and as directed.
M&L for Machine cut kota stone slab(mirror polished) flooring 18-20mm thick in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:4) complete all as specified and directed.
M&L for 20mm thick granite stone slab (of any type) work (table rubbed and polished) in cooking platforms, in steps, pillars, window cills, etc, laid over 15mm thick bedding in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite slab, rounding edges etc complete all as specified and directed.
S&F for 100mm bore PVC waste and vent pipes in any length with or withour ears with cement joints laid in floors complete as all specified and directed.
M&L for PCC (1:3:6), type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes of 100mm bore pipe including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
S&F for assembled ready to use rectangular stainless steel (Grade 304) kitchen plate rack with 3-4 shelves, enclosed four sides by SS plain sheet, 0.6 mm squre support pipes, dedicated holes for spoon, pegs etc cover all size 600mmx1200mmx250mm of standard pattern complete all as specified and directed.
S&F for sink with drainage board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in CM to dwarf wall or including fixing cantilever brackets and connecting union to pipe, over all size 495mm x 420mm, bowl size 410mm x 330mmx 160mm complete all as specified and directed.
Demolition of RCC roofs floors (other than ground floors) beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement and disposal of rubbish out of MoD land complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F for 20 mm bore GI tubing (medium grade) with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F for 15 mm bore GI tubing (medium grade) with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed.
M&L for 20mm dia (internal) gun metal, glove or gate valve with iron wheel head, screwed on both sides for iron pipes complete all as specified and directed.
M&L for 15mm dia bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe complete as in repair as in repair all as specified and directed.
S&F for 15mm bore fancy type chromium plated angle valves, cast copper alloy with crutch or butterfly handle screwed for iron pipe or for brass ferrule and fixed complete as in repair all as specified and directed.
S&F for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
Excavation over area exc. 1.5 m depth and 1.5 width for foundation etc in hard/dense soil and getting out complete all as specified and directed.
M&L for PCC (1:4:8), type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
M&L for PCC (1:3:6), type C-1 (using 20 mm graded stone aggregate) as in bond stone in stone walling set in Cement mortor (1:6) complete all as specified and directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar (1:4) complete all as specified and directed.
M&L for hand packing with broken stone or boulders (any thickness) at back of wall over arches etc and raising or lowering to the reqd level complete all as specified and directed.
M&L for 75mm dia PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints, laid in trenches or in floor, or as in weep hole complete all as specified and directed.
M&L for 75mm thick PCC type C-2, (1:3:6) (using 40mm graded stone aggregate) as in sub base of flooring/ hard standing/pavings finished even and smooth without using extra cement complete all as specified and directed.
M&L for surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, drilling for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:6) other than fair faces of stone/brick surface, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening complete all as specified and directed.
M&L for 4mm thick designer cement fibre ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions complete all as specified and directed.
M&L for joint, channel, angle, MS tubular pipes or tee sections fixed independenetly with or without connecting plates, cut to ordinary lengths i.e within 20mm of the length given complete all as specified and directed.
S&F for Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
M&L for plates(plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes without any attachement complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long and shank 10mm dia complete all as specified and directed.
M&L for preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 Mpa as in ridges, hips, valley gutters, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S& F for stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for 12mm thick veneered decoarative plywood, grade 1 (with BWR rasin) with (with BWR resin) with decorative face veneers on both faces, fixed with screws to timber/steel frame work complete all as specified and directed.
M&L for hard core of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed.
M&L for 1.25mm thick mild steel plain sheet in wall cladding, steel gates and similar work cut to size holes punched including round headed screw clout nialsa or rivet and fixed to steel framing plain 40mm lap joints with reveted or welded seams including bending or turning up mitred angle etc complete all as specified and directed.
M&L for 50mm thick PCC type C-1, (1:3:6) (using 20mm graded stone aggregate) as in plinth protection, finished even and fair, without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed. (Note:- Inner girth only measured)
M&L for 100mm thick cement concrete type B-2 (1:2:4) using 40mm graded stone aggregate as in hard standing and footpaths complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC casing & caping of 25mm width (Medium grade double locking system) complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 59 above but for one 5 pin 5 Amp socket outlet on same board controlled by one 6 amp switch complete all as specified and directed.
Description all as per Serial item No 59 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one 6 amp switchcomplete all as specified and directed.
Description all as per Serial item No 59 above but for one 6 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for Switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
M&L for switch socket combination, 6 pin 5 amp flush type complete all as specified and directed.
M&L for Switch socket combination, 6 pin, 5 Amp and 16 Amp, 230 volts, 2 in 1 flush type complete all as specified & directed.
M&L for socket 5 pin, 5 Amp flush type complete all as specified & directed.
M&L for Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Supply and fixing in replacement Lamp holder insulated body PVC/ Polycabonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 15 watt complete all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete all as specified and directed. (Make :- Havells cat No LHEXAPP7IN1W020 or equivalent in Crompton/Philips)
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion earthing complete all as specified.
S&F for High efficacy 2'x2' recess LED flat panel light 36W LED 6000K edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size (Make :-Havells, Cat part PLUTONEO02X2PLR34WLED840S or equivalant of Crompton Greaves /Philips
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed. (Make :- Havells Cat part No HEXAFT10WLED857SSYMBOPC or equivalant of Crompton Greaves /Philips)
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
S&F for factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distribution board 12 way painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 160 Amps, FP, rating upto 36 KA and MCCB as outoing and complete with including 200 Amps rated copper busbar, neutral bar, earth bar, conneting cable links with and including top bottom removeable gland plate complewte with IP 66 protection complete all as specified and directed. (Note:- MCCBs will be measured separately.)
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 08 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 40 amps, with rupturing capacity 25 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB triple pole and neutral 415 volts any rating 63 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
S&F for exhaust fan of 300mm sweep, heavy duty, 900 RPM electrical operated 230 Volts AC single phase with metal body with all accessories and louver tec complete all as specified and directed.
M&L for Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
S&F for sheet metal enclosure single pole and neutral with two pin and earth plug and AC socket with one single pole MCB 20 amp complete as in repair all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. (Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for MCCB triple pole & neutral 415 Volt any rating from 100 amps adjustable type with rupturing capacity 35 KA, including providing thimble for out going cable complete all as specified and directed
Supply, Laying, connecting and testing of service cable of size 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete all as specified and directed.
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. The minimum depth height width of panel is 450x1200x1200 mm respectively, minimum claerance from ground level is 450 mm complete all as specified and comprising :- (a) MCCB, 200 Amps, FP, 36 KA, 415 volts, 50 Hz - 01 No (Adjustable type) (b) MCCB, 100 Amps, FP, 36 KA, 415 volts, 50 Hz - 03 Nos (Adjustable type) (c) MCB, 32 Amps, SPN, 10KA, 415 volts, 50 Hz, "C" Series - 5 Nos (d) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (e) LED phase indication lamps RYB-01 set (f) Aluminium bus bar TPN 600 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for foundation, laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for 50mm bore GI tubing light grade with fittings in replacement laid for protection of cable undre road crossing fixed to wall or pole complete all as specified and directed.
Supply, install, fixing, testing and commissioing of water coole fully stainless steel body, electric driven single phase, 230V, 50Hz having storage capacity 150/150 ltrs/hr and nominal cooling including suitable float valve and stainless steel water tap and making pipe line connection complete all as specified and directed.
Supply, install, fixing, testing and commissioing of water coole fully stainless steel body, electric driven single phase, 230V, 50Hz having storage capacity 80/80 ltrs/hr and nominal cooling including suitable float valve and stainless steel water tap and making pipe line connection complete all as specified and directed.
Supply, fix, testing and commissioning refrigrator, electric driven (single phase), double door cooling capacity upto 195 litres. BEE 4 star rated, copper coil fixed with invertor compressor, with automatic defrost arrangement and metalic colour including all accessories complete all as specified and directed.
Supply, fix, testing and commissioning refrigrator, electric driven (single phase), double door cooling capacity upto 310 litres. BEE 3 star rated, copper coil fixed with invertor compressor, with automatic defrost arrangement and metalic colour including all accessories complete all as specified and directed.
Supply, fix, testing and commissioning refrigrator, electric driven (single phase), double door cooling capacity upto 340 litres. BEE 3 star rated, copper coil fixed with invertor compressor, with automatic defrost arrangement and metalic colour including all accessories complete all as specified and directed.
S&F for deep freezer invertor technologu of capacity 320 ltrs double door, metal top, 240 volts, 50 Hz, with asthetic soft look design, castor wheels, CFC free insulation, door lock with R-134 refrigarent, precoated body finish with accessories complete all as specified and directed
Supply, installation, testing and commssioning of wall mounted split type air conditioner 1.5 TR capacity of inverter technology including cooling and heating mode for all weather condition with cordless remote control, single phase 240 volts complete with all accessories such as indoor and outdoor unit and refrigernet tubing of adequate length as required as site, indoor mounting plate, drain pipe of suitable size brought to ground level from any height includintg making cable connection by providiing three core 4 sqmm copper conductor cable PVC insulated, sheathed of adequate length as required at site and initial filling of refrigerant gas drain pipe and cables etc and making the round hole on existing wall of any type and making good the disturbed surface by matching with existing adjoining surfaces complete all specified and directed.
Supply, installation, testing and commssioning of wall mounted split type air conditioner 2.0 TR capacity of inverter technology including cooling and heating mode for all weather condition with cordless remote control, single phase 240 volts complete with all accessories such as indoor and outdoor unit and refrigernet tubing of adequate length as required as site, indoor mounting plate, drain pipe of suitable size brought to ground level from any height includintg making cable connection by providiing three core 4 sqmm copper conductor cable PVC insulated, sheathed of adequate length as required at site and initial filling of refrigerant gas drain pipe and cables etc and making the round hole on existing wall of any type and making good the disturbed surface by matching with existing adjoining surfaces complete all specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
S&F for voltage stabilizer 10 Amps, Single phase, 240 volts, AC, 50 Hz of working range 170 volts-270 volts, time delay 3 minutes +/- 2.5 %, wall mounting type, capacity of 2 KVA complete as and when complete damage and non repairable as in reapir all as specified and directed by GE as and when required. (Make - V-guard, Model No VG400AC or equivalent model of Sen & Pandit/ Hitachi/Blue star)
S&F for voltage stabilizer 12.5 Amps, Single phase, 240 volts, AC, 50 Hz of working range 170 volts-270 volts, time delay 3 minutes +/- 2.5 %, cooled indoor type, capacity of 4.0 KVA complete as and when complete damage and non repairable as in reapir all as specified and directed by GE as and when required. (Make - V-guard, Model No VG500AC or equivalent model of Sen & Pandit/ Hitachi/Blue star)
S&F for voltage stabilizer 12.5 Amps, Single phase, 240 volts, AC, 50 Hz of working range 170 volts-270 volts, time delay 3 minutes +/- 2.5 %, collded indoor type, capacity of 5 KVA complete as and when complete damage and non repairable as in reapir all as specified and directed by GE as and when required. (Make - V-guard, Model No VG500AC or equivalent model of Sen & Pandit/ Hitachi/Blue star)
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .