Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
19 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) TEZPUR
GE (N) TEZPUR co 99 APO
SPL REPAIR TO BLDG NO T-14 (COOK HOUSE) OF 4 CORPS CITS,SECT-V HARCHURA AND CERTAIN OTHER LBW/REV WORKS AT CHARDUAR AREAUNDER GE (NORTH) TEZPUR
2021_MES_423641_1
GE(N)/TEZ/2020-21/8459
Open Tender
Civil Works
Item Rate
240 days
GE (N) TEZPUR
As per tender docus
8 documents required · 8 mandatory
₹500
GE (N) TEZPUR
₹42,000
Yes
23 Mar 2021
19 Feb 2021
22 Mar 2021
19 Feb 2021
19 Mar 2021
5 Mar 2021
20 Feb 2021 - 27 Feb 2021
60 days
Amount
Note 1: (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Demolition of Wall and ceiling boards (fibre,pulp, insulation,etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level ) unreinforced complete all as specified and directed.
Demolition of brickwork masonry built in cement mortar including all quoins, arches pillars etc complete all as specified and directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed.
Dismantling of Asbestos cement (corrugated or semicorrugated etc) sheets in roof coverings complete all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins,etc under 40sqcm in section but framed work complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position unframed work as in purlins and rafters etc complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position but framed work as in wall plates / tie, lath guard frames etc complete all as specified and directed.
Dismantling boarding, any description, fixed any position with nails complete all as specified and directed.
Surface dressing n.exc 15cm deep soft/loose soil complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Taking down cement plaster of any description on brick or stone wall etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm with shutters from the frame (without taking off shutters from the frme ) complete all as specified and directed.
Taking down chowkats or frames not exc. 1.5 sq. m each with shutters from the frame (without taking off shutters from the frme) complete all as specified and directed.
Excavation in trenches, nexc 1.5 m wide and nexc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, Manhole, Pier Holes, etc nexc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete in all respect as specified and directed.
Excavation over areas, n exc 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n,exc 25 cm thick in soft /loose soil for sewage pipe line /manhole and cleaning the site complete all as specified and directed.
Removing excavated materials(Soil) n. exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for 100 mm thick cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in sub base under floor complete all as specified and as directed.
M&L for 75mm thick cement concrete type C-2,1:3:6(using 40mm graded crushed stone aggregate) as in plinth protection and foot path making finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 100/110 mm bore pipe cement concrete bed type 1:3:6 C2 (using 40mm graded crushed stone aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for PCC, 1:3:6 type C-2,(using 40mm graded crushed stone agg) as in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete type-C2 1:3:6 (40mm garaded crushed stone agg) in surface channle and drains complete all as specified and directed.
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) to receive the top layer of tiles complete all as specified and as directed.
M&L for 25mm thick Type B0,1:2:4 (using 12.5mm graded crushed stone aggregate) damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete complete all as specified and as directed.
M&L for RCC type B1,1:2:4 nominal mix(using 20mm graded crushed stone aggregate) in beams,cantilevers,bressummers,lintels over 1.5m span complete all as specified and as directed.
M&L for R.C.C 1:2:4 type B1 nominal mix (using 20mm graded crushed stone aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs complete all as specified and directed.
M&L for RCC 1:1.5:3 type A1 nominal mix ( using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in coping benching,bed plates and the similar including, wheathering,slightly rounded or chamfered edges and throating as directed including demolition of old and cleaning of surfaces complete all as specified and directed.
M&L for PCC type B-0. 1:2:4, 25mm thick (using 12.5mm graded crushed stone aggregate) as in floor finishes finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC type B-0. 1:2:4, 40mm thick (using 12.5mm graded crushed stone aggregate) as in floor finishes even and smooth using extra cement complete all as specified and directed.
M&L for cement concrete in foundations, filling and mass concrete 1:2:4 type B2 (using 40mm stobne agrregate) complete all as specified and directed
M&L for extra for forming fair finished drain or channel any girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed.
M&L for brickwork with sub class’B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for brick work with sub class’B’ bricks using old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for brickwork with sub class’B’ bricks, straight or curved on plan exc 6m mean radius in half brick work built in CM 1:4 complete all as specified and as directed.
Sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for rendering 10 mm thick plastering on fair faces of brickwork surfaces and making smooth and even surfaces without using extra cement in CM 1:6 complete all as specified and as directed.
M&L for rendering 10 mm thick, CM 1:6 on other than fair faces of brick work or concrete surfaces by making surfaces as to receive wall tiles etc complete all as specified and directed.
M&L for rendering 10 mm thick plastering but as in CM 1:4 on other than fair faces of brick work and 5mm thick floating/setting coat using water proofing compound over it complete all as specified and as directed.
M&L for rendering 15mm thick, CM 1:4 on fair faces of brick work or concrete surfaces by making surfaces even and smooth (mixed with water proofing compound @ 3% of weight of cement or as per manufacturer's instruction without using extra cement complete all as specified and directed. Note:- water proofing compound shall be measured & paid for separately under relevant item.
M&L for rendering 10 mm thick in CM 1:4 on one side of lathing and making surfaces even and smooth without using extra cement. complete all as specified and directed.
M&L for rendering 15 mm thick, CM 1:4 on other side of lathing by making surfaces even and smooth (mixed with water proofing compound @ 3% of weight of cement or as per manufacturer's instruction without using extra cement complete all as specified and directed. Note:- water proofing compound shall be measured & paid for separately under relevant item.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick wall finished even & smooth without using extra cement complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed.
M&L for rendering 10 mm thick screed bed on fair faces of brickwork surfaces in CM 1:3 to receive wall finishes complete all as specified and as directed.
Supply only water proofing compound complete all as specified and as directed.
Supply only liquid water proofing compouncomplete all as specified and directed.
M&L for Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.11sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L Non skid ceramic tile 7-8 mm thick area of each tile exc 0.11 Sqm but not exc 0.18 sqm in floor set and jointed in neat cement slurry and point in white cement to match colored tile over 20mm screed bed in CM 1:4 complete all as specified and directed.
M&L Non skid ceramic tile 7-8 mm thick area of each tile exc 0.11 Sqm but not exc 0.18 sqm in floor set and jointed in neat cement slurry and point in white cement to match colored tile on vertical surfces over 10mm thick plastered surface in CM 1:3 complete all as specified and directed.
M&L coloured glazed ceramic tiles 200x 300x7 mm thick, in vertical surfaces, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic colour tiles 400x400x7/8mm thick (Joint free tiles) as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone slab as in steps and risers /dado/skirting, 20-25mm thick over 20 mm thickcement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situationscomplete all as specified and directed.
S&F Fe 410-W(Gde-E250) roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed.
S&F for steel work in tubular trussess /posts including special shaped washers etc complete using ERW or including butt welded tubes confirming to IS 1161 - 1979 grade St -240 ( using m s pipe medium grade) complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F Mild steel TMT Bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
S&F mild steel plates (plain or chequered) channels , square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment confirms to Fe410-w (gde-E-250) quality B complete all as specified and directed.
S & F Mild steel screw bolts( up to 20mm dia) (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, lain angle cleats for securing purlinsdrilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for Formwork to rough finished edges of concrete flats soffits of suspended slabs flat or batter such as roof slabs, floor slabs and similar work not exceeding 200 mm thick complete all as specified and directed.
M&L for Formwork to sides of concrete foundation,footing bases of coloumns,raft and raft beams,sides and soffit s of foundation and plinth beam and similar work vertical or to batter complete all as specified and directed.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rein forced with M.S. square tube supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plaincolour PVC ‘C’ channel PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock and bottom rail on either side as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded. Sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing complete all as specified and directed.
M&L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of redoxide complete all as specified and as directed.
M&L for preparation of new plastered surface and applying two coats cement base paints on walls complete all as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new steel surfaces, width or girth exc 10 cm and applying two coats of synhetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, width or girth exc 10 cms and applying two coats of synhetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, width or girth exc 10 cms and applying one coats of synhetic enamel paint complete all as specified and directed.
M&L for Preparation of surface of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, width or girth not exc 10 cms and applying two coats of synhetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L for preparation of old Plastered surfaces of wall after complete removal of existing treatment and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed.
M&L for preparation of old Plastered surfaces of wall after complete removal of existing treatment and applying two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint complete all as specified and directed.
M&L for complete removal of existing treatment of walls and apply three coats of white wash complete all as specified and directed.
M&L for Preparation of new plastered surfaces of walls and apply three coat of white wash complete all as specified and directed.
M&L for Preparation of new plastered plastered/unplastered surfaces of ceilings and applying two coats of white wash.
S&F Butt hinges,medium weight cold rolled mild steel 100mm long (ISI marked) complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section 200mm long (ISI marked) complete all as specified and directed.
S&F Aluminium handles cast type anodised 150mm long (ISI marked) complete all as specified and directed.
S&F 500 litre capacity ,rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) in position all specified in SSR Part –I complete all as specified and directed.
M&L Ball valves (20 mm) high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms/ 50mm-1240 gms) complete all as specified and directed.
S&F 20mm dia stop cock of PTMT any colour high pressure screwed for iron pipe complete all as specified and directed.
S&F 15mm bore medium grade tubes, galvanized with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore medium grade tubes, galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F Vitreous China wash basin, white, flat back, size 630x450mm (flat back or angle back type) includingbrackets, cutting for and pinning 'in brackets waste coupling, waste pipe, grating complete all as specified and directed.
S&F Vitreous China Urinal, Half stall type, white (back or corner wall type) complete incl providing and fixing plugs beding urinal against wall in cm 1:2 security urinal plug with and incl 60mm long brass screws pointing around urinal back in cement fixing automatically flushing cistern with bracket, flush pipes grating and union for discharge pipe complete all as specified and directed.
S&F Vitreous China Urinal partition white of size 310X770mm complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with orwithout lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F 15mm bore stop valves/angle cock, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F cast copper alloy urinal spreader for fixing with 15 mm dia pipe complete all as specified and directed
S&F PVC connections 15mm size with PTMT nuts of length 300/450mm complete all as specified and directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F 75mm bore PVC ( SWR) pipes single socketed ,in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) bends of radius 75mm borecomplete all as specified and directed.
S&F PVC (SWR) junction single,(Single T) equal or unequal of radius 75mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding , joists, etc. In walls, ceilings, stanchions, beams, etc. Including all laps ,cutting and waste complete all as specified and directed.
M&L for Glass dividing strips, 3mm thick, 38mm wide and inserted in position to conform to design complete all as specified and directed.
M&L for second class hard wood wrought in scantling (timber fixed) complete all as specified and as directed.
M&L for boarding 50mm thick second class hardwood as in rafters, purline, joists of ceiling etc complete all as specified and directed.
M&L for boarding 50mm thick second class hardwood as in rafters, purline, joists of ceiling etc but except boarding complete all as specified and directed.
M&L for boarding 20mm thick second class hardwood as in eves boards in ceiling etc complete all as specified and directed.
S&F 4mm thick asbestos cement plain building boards, fixed to timber framework in ceiling with screws/ nailing complete all as specified and directed.
M&L for 2nd class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads (sectional area exc13 sq.cm & n exc 25 sq.cm) as in studs of ceiling / sunshed complete all as specified and directed.
M&L for 2nd class hard wood plain fillets ,square, rectangular or triangular in section, clean sawn,secured with nails or brads (sectional area exc 6sq cm & n exc 13 sq.cm) as in forking pieces in ceiling studs of ceiling/ mosquito proofing framing complete all as specified and directed.
S&F 2nd class H W plain fillets, square, rectangular or triangular in section, area exc 3 sq cm but not exc 6 sq cm, wrought secured with nails complete all as specified and directed.
S&F for second class Hard wood as in plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F 35mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels),with panels of timber flat on both sides(feather edged),or of veneered particle board medium density, wood particle board with commercial face veneers, fitted to chowkats complete all as specified and directed.
S&F 2nd class H/W glazed and skeleton shutters 35mm thick open rebated and prepared to received glass, without (sash bars), edges of framing plain , chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, Section 1 Clause 8.20 (a) complete all as specified and directed.
S&F 30mm thick glazed and skeleton shutters 2nd class hard wood , open rebated and prepared to receive glass, gauge etc divided into squares, with plain, cham-fered or rounded, mitred and rebated sash bars provided with stiles and rails as specified in SSR Part I ,section 8 clause8.20(b) complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane complete all as specified and directed.
S&F Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu.cm each complete all as specified and directed.
S&F 75mm medium weight ,cold rolled mild steel but hinges(ISI marked) complete all as specified and directed.
S&F 200mm long mild steel barrel tower bolts ,stove enamelled black, with bright bolt (ISI marked) complete all as specified and directed.
S&F 150mm long aluminum anodised barrel tower bolts ,of extruded section (ISI marked) complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy (ISI marked) complete all as specified and directed.
S&F 100mm aluminium handles,cast type, anodised (ISI marked) complete all as specified and directed.
M&L for reinforced concrete pipes, bore of pipe 600mm, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for reinforced concrete pipes, bore of pipe 450mm, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for 150mm thick boulder pitching, laid dry, hand with tightly complete all as specified and directed.
E/M PORTION
Taking down carefully aluminium conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. to match with the existing complete all as specified and directed.
M&L for point wiring of light/fan/bell controlled by one, one way switch using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, FRLS PVC insulated sheathed cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed terminal boxes confirming to IS-14772-20000 for mounting of switches/sockets/regulators/bell push etc and1.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc complete all as specified and directed.
M&L for point wiring for one 3 pin socket outlet 5 amps on independent board using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, FRLS PVC insulated sheathed cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed terminal boxes confirming to IS-14772-20000 for mounting of switches/sockets etc and1.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc complete all as specified and directed.
Ditto as per item No-137.00 here in before but for 5 Amps socket point on same board complete all as specified and directed..
M&L for wiring for one 3 pin socket outlet 15 amps on independent board using 2.5 Sq mm nominal cross sectional area multistranded copper conductor, FRLS PVC insulated sheathed cables in and including casing & capping of suitable size with fittings complete fixed to wall/ceiling including PVC closed terminal boxes confirming to IS-14772-20000 for mounting of switches/sockets etc and 2.5 Sq mm nominal cross sectional area multistranded copper conductor PVC insulated sheathed earth wire and connecting to earth dolly by means of screws, washers etc complete all as specified and directed.
S&F Polycarbonate Switch piano flush type, SP 6 Amps one way complete all as specified and directed.
S&F Polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch complete all as specified and directed.
S&F Polycarbonate switch socket out let 2 in 1 socket 5 pin, 5&15 amps flush type controlled by one 15 Amps switch complete all as specified and directed.
S&F ceiling fan regulator electronic type 240 volts ISI marked 5 steps and connecting complete all as specified and directed.
S&F in replacement wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver lamp type 20 watt 6000K 4 feet complete all as specified and directed. Make- Surya Roshni Cat Part No -SLE BTN T8 or Equivalent of (i) Bajaj (ii) Wipro (iii)Philips
S&F ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB DB double door 8 ways with 200 Amps rated bus bar SPN complete all as specified and directed.
S&F sheet metal enclosure for MCB DB single pole 12 ways double door all complete all as specified and directed.
S&F in repair MCBs SP 6-32 amps rating and to be housed in DBs catered here in before complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCBs are deemed to be included in unit rate of each MCB of any rating)
S& in repair MCB single pole and neutral(SPN) 6-32 Amps B series socket point on same board complete all as specified and directed.
S&F MCB TPN 63 Amps including making all necessary electrical connections all as required at site complete all as specified and directed.
S&F MCB SPN 40 Amps including making all necessary electrical connections all as required at site.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
M&L for submain wiring with two runs of PVC insulated multistranded, copper coductor of size 4 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 4 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 4sqmm cable and one run of 4sqmm earth cable including one run of casing capping shall be measured as one unit.
S&F in repairs for fan hook made out of mild steel flat iron of size 40mm x 5mm and 66 cm long including taking down old unserviceable fan hook complete all as specified and directed.
M&L for house service bracket (hook type) complete with 3 mtrs long GI pipe 40mm dia, medium grade, 2 Nos 90 degree MS hook and stay or gay on the wall by grouting cement mortar and make good on all disturbed surfaces complete all as specified and directed.
M&L for one twin core cable flat or circular, 1100 volts grade heavy duty cable, PVC insulated, with stranded aluminium conductor, size 10 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating in service hangers not more than 1 metre apart including 4mm GI suspension wire, and including taking down of unserviceable service connection complete all as specified and directed.
Taking down old/defective ceiling fans of any size/sweep and transproting these to MES store yard for deposition and supply & fixing ceiling fans 1200mm sweep complete including provision of PVC insulated copper multi starnded three core flexible cable for making necessary electrical connections from ceiling rose to connector all as required at site complete all as specified and directed.
S&F in replacement of bracket for street light fitting fabricated with 1200 mm long and 40 mm bore medium grade GI pipe bent to shape as required and fixed in position including necessary clamps,nuts,bolts & washer complete all as specified and directed.
S&F connecting new generation energy saving environment friendly long life LED street light made up of pressure die cast aluminium housing with high power LEDs as light source and lens embedded PC cover with IP-66 protection and impact resistance of IK07 having 35 watt 5700K LED with prewired and necessary mounting and connecting arrangement to overhead street light feeder complete all as specified and directed including taking down of old/unsv street light fitting of any description complete all as specified and directed. Make- Phillips Cat Part No - BRP050 LED 036 CW R1 MF PC S1 PSU GR or Equivalent of (i) Bajaj (ii) Wipro (iii)SURYA ROSHNI LTD
M&L earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common saft filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron light grade pipe 15mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in Electrical Plate No 3 of SSR 2009( Part-I) complete all as specified and directed.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws type 410 SP-55 (11 meter long) complete all as specified and directed.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws type 410 SP-64 (12 meter long) complete with CI base plate and finial including foundation and coping complete all as specified and directed.
S&F PVC pole mounted junction box protection class IP66/67 weather proof for outdoor installation with hinged door including knockout of cable entry of size 155x210x92mm and connection of LT cable any size with suitable size lugs/thimbles and nut,bolts and washer including necessary fixing arrangement with MS clamp of suitable size including nuts and bolts complete all as specified and directed. Make-Hensel Model No-KF1616B or its equivalent.
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated of size 16 Sq mm cross sectional area, 4 core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutlistranded, heavy duty 1100 Volts grade complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated of size 10 Sq mm cross sectional area, 2 core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutlistranded, heavy duty 1100 Volts grade complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items).
S&F LED flood light Luminare with ultra sleek light weight and with secondary optic, made out of pressure die cast housing with IP 65 protection 150 watt complete all as specified and directed. Make- Phillips Cat Part No - BVP122 LED150 CW HE SY 20' FGXTFCL S4 or Equivalent of (i) Bajaj (ii) Havells india Ltd (iii)SURYA ROSHNI LTD
S&F LED flood light Luminare with ultra sleek light weight and with secondary optic, made out of pressure die cast housing with IP 65 protection 105 watt complete all as specified and directed. Make- Phillips Cat Part No - BVP122 LED105 CW HE AK 55' FGXTFCL S4 or Equivalent of (i) Bajaj (ii) Havells india Ltd (iii)SURYA ROSHNI LTD
M&L 1.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed drawn through pipe or fixed with poles for necessary electrical connections of street light fittings complete all as specified and directed.
M&L for Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat with red oxide Zn Chromium and two coats of synthetic enamel paint complete all as specified and directed.
S&F air cooled split unit air conditioner electric driven single phase of capacity of 2 TR, 3 star rated with rotary compressor,copper condensing coil having cooling capacity 6200W or more, air flow in 2 way direction with minimum indoor noise level, air filter remote and manually opereted having first fill of latest refrigerant including fixing charges, making necessary holes for piping/cables and mounting bracket nuts,bolts and washers as required at site complete and making good disturbed surfaces of walls etc to match the existing and testing on completion all as specified and directed. Note: Cost of extra copper pipes of any size of any length to connect the indoor and outdoor units shall be deemed included in unit rate quoted by the contractor and no extra cost shall be paid for the same.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.
M&L for river sand,granular sized, washed and screened dried completely free from harmful and organic matters for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete all as specified and directed. Note:-Only punned thickness after specified compaction shall be considered for measurement and payment.
M&L for laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection complete all as specified and directed.
M/S L N ENTERPRISE
M/s Adil Construction
M/S BHAGWATI CONSTRUCTION CO.
M/s Brahamaputra Wood Industries
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .