Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-Finance | L1 | Accepted-Finance 1st LOWEST BIDDER | |
| 2 | L2₹3.6 L+₹67,650 (22.9%)Rejected-Finance | L2 | Rejected-Finance 2nd LOWEST BIDDER | |
| 3 | L3₹3.9 L+₹97,120 (32.9%)Rejected-Finance | L3 | Rejected-Finance 3rd LOWEST BIDDER | |
| 4 | L4₹3.9 L+₹99,140 (33.6%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L4 | Rejected-Finance 4th LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MODERN ELECTRICALS L2 | RAHUL TRADERS L1 | DAS ENTERPRISE L4 | CHAKRABORTY ELECTRIC L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 3.5 kW or higher based on latest ISEER rating 3.92 (BEE: 2 Star/2026) or higher, maximum power consumption 1360 Watts or less, minimum tonnage 1.1 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 550 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher.The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA14BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more] | 1 | Set | 59,999 ₹59,999 | 45,000 ₹45,000 Lowest | 65,000 ₹65,000 | 65,000 ₹65,000 |
| 2.00 | Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 5.2 kW or higher based on latest ISEER rating 3.84 (BEE: 2 Star/2026) or higher, maximum power consumption 1450 Watts or less, minimum tonnage 1.5 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 777 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher. The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA18BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more] | 2 | Set | 68,523 ₹1,37,046 | 52,000 ₹1,04,000 Lowest | 75,000 ₹1,50,000 | 75,000 ₹1,50,000 |
| 3.00 | Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 7.0 kW or higher based on latest ISEER rating 3.81 (BEE: 2 Star/2026) or higher, maximum power consumption 1800 Watts or less, minimum tonnage 2.0 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 777 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher. The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA24BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more] | 1 | Set | 79,653 ₹79,653 | 70,000 ₹70,000 Lowest | 85,000 ₹85,000 | 85,000 ₹85,000 |
| 4.00Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for the system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required [Cu. Pipe Make : Nippon/Mandev/Ryoku][Insulation Make-K-Flex/Accroflex/Suprime] | |||||||
| 4.01 | 6.35 mm dia (OD)with tube thickness0.8mm with 9mm thick nitrile insulation for liquid line for 2/1.5/1 Tr split AC Machine | 40 | RM | 595 ₹23,800 | 550 ₹22,000 Lowest | 550 ₹22,000 Lowest | 636 ₹25,440 |
| 4.02 | 15.9 mm dia (OD) with tube thickness 0.8 mm with 9 mm thick insulation for suction line for 2/1.5 Tr split AC machine | 40 | RM | 695 ₹27,800 | 670 ₹26,800 | 636 ₹25,440 Lowest | 725 ₹29,000 |
| 5.00Supply, laying and termination of 1.1 kv grade following size PVC insulated PVC sheathed unarmoured Copper Cable (Make:-Finolex/Havells/Polycab) Control Cabling from Condensing Unit to control panel | |||||||
| 5.01 | a) 4 core 2.5 sq.mm communication cable | 40 | Mtr | 375 ₹15,000 | 310 ₹12,400 Lowest | 325 ₹13,000 | 425 ₹17,000 |
| 6.00 | Installation Testing and Commissioning of wall mounted fixed speed split Air-Conditioners by making scaffolding arrangement as per site condition, incl.Supply & Charging of necessary Refrigerant, Outdoor brackets for holding and fixing the ODU, plates for fixing the IDU and connecting Control & power cabling & other necessary materials to complete the job. | 4 | Job | 239 ₹956 | 205 ₹820 Lowest | 230 ₹920 | 245 ₹980 |
| 7.00Supply & Installation of 6mm Nitrile Rubber insulated PVC / HDPE pipes of following sizes with fitting, accessories, bends, elbows, tees, flanges, U-trap, wall sleeves, hangers, supports, anchors etc for draining condensate water from indoor unit to the nearest drain point.[Make-Finolex/Suprime/Astral] | |||||||
Tender Value
Refer Docs
EMD Value
₹5,939
Closing Date
6 Jun 2026, 12:30 pmClosed
SE,SWEC,PWD, MIDNAPORE
GOVERNMENT OF WEST BENGAL OFFICE OF THE SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur
Construction (Civil and Electrical ) of a new two pump fire station (Gplus1 storied building with foundation of Gplus3 storied building ) at Manbazar in Purulia District--- SITC of Air-Conditioning System
2026_WBPWD_5014334_1
WBPWD/SE/SWEC/NIQ02/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,939
OFFICE OF THE SE,SWEC,PWD,MIDNAPORE
3 Aug 2026
22 May 2026
8 Jun 2026
22 May 2026
6 Jun 2026
26 May 2026
25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 3.5 kW or higher based on latest ISEER rating 3.92 (BEE: 2 Star/2026) or higher, maximum power consumption 1360 Watts or less, minimum tonnage 1.1 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 550 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher.The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA14BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more] | |||||
| 2Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 5.2 kW or higher based on latest ISEER rating 3.84 (BEE: 2 Star/2026) or higher, maximum power consumption 1450 Watts or less, minimum tonnage 1.5 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 777 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher. The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA18BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more] | |||||
| 3Supply and delivery of Fixed Speed 220V, 50Hz, Single Phase (with applicable tolerance) Room Air Conditioner fitted with rotary compressor and copper condenser and cooling coil having the following major specifications: Refrigerant R410A/R32, Capacitor Type P2, minimum cooling capacity 7.0 kW or higher based on latest ISEER rating 3.81 (BEE: 2 Star/2026) or higher, maximum power consumption 1800 Watts or less, minimum tonnage 2.0 TR (as per manufacturer’s standard) or higher with other modern features, and minimum room discharge air flow 777 CFM or higher.The unit shall be capable of operating satisfactorily at an ambient temperature of 50°C or higher. The unit shall comply with all latest amendments and modifications of IS 1391 (Part-I) and shall be supplied complete with remote control, necessary connection kit, piping kit and all standard accessories as provided with Outdoor Unit (ODU) and Indoor Unit (IDU) as per manufacturer’s standard. Make: Fujitsu General – ASGA24BMAA-B (R32) or equivalent model of Mitsubishi Heavy Industries / Mitsubishi Electric complying with the above specifications. [Standard warrenty by OEM should be provided for Machine 1Year or more , For Compressor 5 Years or more] | |||||
| 4Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for the system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required [Cu. Pipe Make : Nippon/Mandev/Ryoku][Insulation Make-K-Flex/Accroflex/Suprime] | |||||
| 4.01 | 6.35 mm dia (OD)with tube thickness0.8mm with 9mm thick nitrile insulation for liquid line for 2/1.5/1 Tr split AC Machine | - | RM | - | - |
| 4.02 | 15.9 mm dia (OD) with tube thickness 0.8 mm with 9 mm thick insulation for suction line for 2/1.5 Tr split AC machine | - | RM | - | - |
| 5Supply, laying and termination of 1.1 kv grade following size PVC insulated PVC sheathed unarmoured Copper Cable (Make:-Finolex/Havells/Polycab) Control Cabling from Condensing Unit to control panel | |||||
| 5.01 | a) 4 core 2.5 sq.mm communication cable | - | Mtr | - | - |
| 6Installation Testing and Commissioning of wall mounted fixed speed split Air-Conditioners by making scaffolding arrangement as per site condition, incl.Supply & Charging of necessary Refrigerant, Outdoor brackets for holding and fixing the ODU, plates for fixing the IDU and connecting Control & power cabling & other necessary materials to complete the job. | |||||
| 7Supply & Installation of 6mm Nitrile Rubber insulated PVC / HDPE pipes of following sizes with fitting, accessories, bends, elbows, tees, flanges, U-trap, wall sleeves, hangers, supports, anchors etc for draining condensate water from indoor unit to the nearest drain point.[Make-Finolex/Suprime/Astral] | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.58 MB
BOQ_5082426.xls
BOQ • 0.36 MB
othercorrigendum.pdf
PDF • 0.36 MB
datecorrigendum1.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .