| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹15.2 L+₹51,752.03 (3.52%)Rejected-Finance 19 1 69 3 PLOT NO 17 NEW ADARSH COLONY BIDAR 585 401 | BIDAR | KARNATAKA | 585401 | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹15.7 L+₹1.0 L (7.09%)Rejected-Finance | L3 | Rejected-Finance Due to L3 | |
| 4 | L4₹16.0 L+₹1.3 L (8.87%)Rejected-Finance | L4 | Rejected-Finance Due to L4 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
26 Aug 2021, 6:00 pmClosed
GE AF BIDAR
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
PROVISION OF POL STORE, SPECIAL REPAIRS TO SWT AND CERTAIN REVENUE WORKS AT AFS BIDAR
2021_MES_445734_3
8277/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF BIDAR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF BIDAR
₹32,000
Yes
19 Oct 2021
10 Aug 2021
27 Aug 2021
10 Aug 2021
26 Aug 2021
12 Aug 2021
Amount
Excavation over area not exceeding 1.5m deep and getting out in soft disintegrated rock complete all as directed.
Excavation over area not exceeding 1.5m deep and getting out in hard / dense soil complete all as directed.
Removal of surplus excavated material to a distance exc 50m but n.exc 250m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
Use and waste of formwork to sides of concrete foundation footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundations, plinth beams and similar works vertical or for batter complete all as specified and directed.
Reinforcement for concrete with steel TMT bars, 10mm dia & over, cut to length, bent to required shape including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and as directed.
All as per item No 5 here in before but 6mm to 8mm dia bars.
All as per item No 5 here in before but 6mm to 10mm dia in stirrups.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), exc. 10cm in width and setting in mortar 1:4, complete all as specified & directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil.
Removal of surplus excavated material to a distance n. exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified.
Providing cement concrete 1:3:6 type C2 (using 40mm graded stone agg) in foundation, mass concrete and filiings.
Providing reinforced cement concrete 1 :1 1/2: 3 type A1 (using 20mm graded stone agg)as in footing, foundation, beams, plinth beams, base for columns and mass concrete etc.
Providing reinforced cement concrete 1 :1 1/2: 3 type A1 (using 20mm graded stone agg) as in columns .
Providing reinforced cement concrete 1 :1 1/2: 3 type A1 (using 20mm graded stone agg) as in Lintel beam, Roof beam, landings, balconies, canopies, desc slabs, slab supported on walls and shelves and the like.
Form work to sides of columns complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Form work rough finished surfaces to sides of soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves incl supports, overhangs etc also splays between floors and beams, etc.
Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface.
Providing cement concrete 1:4:8 type D2 (using 40mm graded stone agg), 100mm thick as in sub base in floor/paving etc.
Providing cement concrete 1:2:4 type B1 (using 20mm graded stone agg), 75mm thick as in floor/paving etc finishing even and smooth using extra cement.
75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement laid in alternate bays as in plinth protection complete all as specified and directed.
Pre-cast cement concrete block masonry with solid blocks built in PCC 1:3:6 (using 20mm graded stone aggregate), exc. 10cm in width and setting in CM 1:6, complete.
Rendering 15mm thick in cement mortar 1:4 finished even and smooth including supply and using water proofing compund as per manufacturer instruction.
Rendering 10 mm thick in cement mortar 1:6 finished even and smooth without using extra cement.
Rendering 5mm thick in ceiling in cement mortar 1:3 finished even and smooth without using extra cement.
Applying three coats of white wash including preparation of new plastered wall surface.
Applying three coats of white wash including preparation of new plastered ceiling surface.
Applying two coats of cement base paint over a coat of alkali resistant primer including preparation of surface.
Steel door including projecting type hinges, steel handle, claded by 1.25mm MS plain black sheet dovetailed or welded, MS sliding door bolt 300mm with hasps welded and 02 nos tower bolts 200mm long welded complete all as specified and directed.
Steel windows glazed, ordinary quality inluding glazing with 4.8mm thick glass with oil putty in square n exc 0.5sqm in each pane with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete.
Painting two coats of synthetic enamel paint (ordinary tint) over steel surfaces of any description, not otherwise described, over 10cm width or girth over a coat of primer.
Antitermite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured).
Antitermite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface.
Antitermite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area.
Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area).
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
Applying aluminium paint 2 coats over a coat of aluminium red oxide primer after preparation of surfaces of any description, over 10cm in width or girth, not otherwise described, all as specified and directed.
Preparation of existing wall surface (SWT) with wire brush and removing dead mortar and applying two coats of brush bond polymer water proofing chemical and 15mm thick rendering with cement mortar 1:4 by mixing chemicals with integral water proofing compound @ 100 ml per bag of 50 Kgs cement as per manufacturer specification and finally applying Kalai finishing complete all as specified and as directed by Engr-in-Charge . MAKE: Dr. Fixit/BASF/SBR/Armstrong
Preparation of existing floor surface (SWT) with wire brush and removing dead mortar and applying two coats of brush bond polymer water proofing chemical and laying 40mm thick average thickness of cement concrete 1:2:4 (using 6mm graded aggregate) ratio with integral water proofing compound @ 100 ml per bag of 50 Kgs cement as per manufacturer specification and finally applying Kalai finishing complete all as specified and as directed by Engr-in-Charge. MAKE: Dr. Fixit/BASF/SBR/Armstrong
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-incharge.
MS angle iron as in fencing post and covering of stating water tank including cutting tops to shape as directed, drilling holes,notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165.
Dismantling of wire mesh chain link fencing any type all as directed.
MS flat iron fillets (for securing chain link fencing) including all necessary drilling, bolting or riveting etc, all as directed.
Supply only Mild steel bolts machine made, with hexagonal or Square head one end and screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 5 cm and n,exc 10 cm long, dia of shank 5 to 10mm dia complete all as specified.
Supply only chain link MS galvanized fencing of any size or type all as specified and directed.
Fixing only Chain link fencing including lines wire, any mesh, ize and type to any type of standards, rails, straining bolts etc including provision of binding wire
Mild steel framed work in doors or gates of angle section with gusset plate braces etc complete drilled for fixing of steel sheeting including hooks etc conforming to Fe-410-0
Welding in repairs n.exc 25mm in length and thickness of metal to be welded n.exc 6mm all as specified and as directed by Engr-in-Charge
Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia and not exceeding 4 kg per square metre supplied and fixed in reinforcement complete.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thick (unreinforced) (below or above ground level) all as specified and as directed by Engineer-In- Charge.
Demolition of brick work/PCC block masonry built in cement mortar.
Plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone agg) as in coping and bed concrete for post of fencing with necessary form work.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement.
Laying only GI pipe 25mm dia bore, medium grade in trences with necessary fittings all as specified and directed. Note: GI Pipe will be issued under Schedule 'B' free for fixing / laying.
Laying only GI pipe 40mm dia bore, medium grade in trenches / on pole with necessary fittings all as specified and directed. Note: GI Pipe will be issued under Schedule 'B' free for fixing / laying.
M&L for Sub main wiring complete with 2 runs of 6 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor cable with one run of 6 Sqmm single core PVC insulated FRLS cable 1100 Volts grade, multistranded copper conductor cable as earth continuity conductor drawn through and including suitable size medium grade PVC conduit pipe and accessories concealed in surface / walls / floors / ceilings / roofs etc., including cutting grooves chases and finishing up matching with existing surface all as specified and as directed. NOTE: Two runs of 6 Sqmm copper conductor, One run of 6Sqmm copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts (for AC) complete all as specified and as directed.
Supply, install, connect, test and commissioning of inverter type Air conditioner Hi wall comprising of units Indoor & outdoor complete with cordless remote control unit, with inbuilt in air ioniser, Plasma filter for better indoor air quality,leakage detector etc with minimum 5 star rating and EER 3.2 of capacity 1.5 TR, inclusive of suction and discharge lines of suitable size and length of copper tube including necesary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket inclusive of suitable drain pipe for disposal of waste water upto groound level and testing ,neatly finishing the disturbed surfaces of walls to match with the surroundings complete all as directed.
Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor FRLS cable drawn in and including stove enamelled steel conduit alongwith 1.5 Sqmm PVC insulated stranded copper FRLS cable as earth lead complete on walls/ceilings for one light point controlled by one switch all as specified and as directed.
CMRI certified LED flame proof tube light fittings 1x16 / 20W for gas vapour of group IIA and zone 1 & 65 protection all as specified and as directed.
Flame proof switch rotary type with termination box in LM6, 16 Amps single pole 250V complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil.
Supply and spreading fine river sand in trenches for cushioning of under ground cable all as directed. Note: Only punned thickness will be measured and paid.
Unreinforced precast concrete cable cover class LV, Type I, flat, of size 250 mm x 150 mm x 40 mm for cable protection.
Supply, lay, connect, test and commisioning of LT XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor multistranded 10 Sqmm 2 Core, 1100 volts grade including connecting the cable ends to the LT Panel/ Transformer /LT OH lines and distribution board complete all as directed by Engineer-in-Charge.
MCB SP 6-32 amps, 'C' Curve, 10 KA, SP 240V complete all as directed by Engineer-in-Charge.
MCB SPN 6-32 Amps, 10 KA, 240V, complete all as directed by Engineer-in-Charge.
MCB DB SPN double door, 4 way 230 V neutral link, earth link complete all as directed by Engineer-in-Charge.
Earthing with GI earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground vertically to a depth of not less than 2.25m deep below normal ground level with top edge of the plate not less than 1.5m below ground level connected to GI earth wire of 4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanised including necessary earth work in any type of soil, PCC 1:3:6 type CI using 20mm graded stone aggregate earth chamber and 1:2:4 type B1 RCC cover 50mm thick with 6mm dia MS bars reinforcement complete all as shown in SSR Part- I electrical plate No 3. Note: Quoted rate deemed to include the cost of excavation and earth work PCC Chamber, funnel cover etc.
famous construction
m/s raghavendra kulkarni
AMAR CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .