-: SCHEDULE –A :-
Name of Work: “Annual Maintenance contract for execution of emergency civil
work, misc. work, addition alteration etc.in DGVCL Corporate office”
Note:- The contractor should make their own arrangement for loading, unloading and cart-
ing of the above mentioned material
CONDITIONS FOR MATERIALS SUPPLIED BY THE CONTRACTOR
1 The above material shall be brought by the contractor to meet with the
requirement of the contract.
2 Cement & steel will be allowed to use in the contract and for allied connected
works with the prior approval of the Engineer - In -Charge.
3 The Steel material will be brought by the contractor on weight basis .However
measurement for the work done will be on Linear measurement basis by
calculating weight as per the sectional measurement as per IS.
4 Wastage steel scrap will not be counted left out after the completion of the work.
5 The contractor will be allowed to take away the wastage of steel scrap after
completion of work with permission in writing from E.I.C.
6 Cement shall be counted 20 bags to one M.T.
7 Empty cement bags is not to be returned to the DGVCL and contractor will be
allowed to take away with permission in writing from Engineer -In -Charge.
8 Necessary Electrical power connection shall be given to contractor by DGVCL on
Addl. Chief Engineer (P),
Sign. Of Contractor
(With rubber stamp/seal of the company)
DAKSHIN GUJARAT VIJ COMPANY LIMITED
SPECIAL CONDITIONS FOR USE OF CEMENT IN WORK:
1. The rates in Schedule-‘B’ are inclusive of cement cost. Contractor has to purchase fresh
43 / 53 grade cement confirming to as per IS 8112 -1991 or PPC (Fly ash Based)
confirming to IS-1489 (Part-I) of approved brand by DGVCL.
2. Contractor has to construct pucca godown at site of work so that cement bags be
properly preserved to avoid damage due to any kind of water. DGVCL will in no way
responsible for any damage, loss or theft of the same.
3. Contractor has to bring sufficient quantities of cement bags and at no time less than
(two hundred) bags to maintain progress of work. The work should not suffer for want
4. Cement should give the required strength of cement concrete.
5. To bring sufficient & timely cement at site is full responsibility of contractor. Nothing
extra will be paid on account of any reason to maintain progress of works and to
complete the works in schedule time.
6. Contractor has to submit material A/c consumption of cement used with every bill. In
case of not submitting the same, bill will not be passed. Party has to submit the copy of
cement / purchase bill along with each RA Bill/Final Bill.
7. Empty cement bags are not to be returned to the corporation and contractor will be
allowed to take away with permission of in writing from Engineer-in-charge.
8. Contractor is fully responsible for safety of cement at site; nothing will be paid extra on
account of safety.
9. If DGVCL’s authorized representative wants to check cement stock at site. Contractor
has to allow for the same at any time.
10. Contractor has to maintain day to day cement consumption balance account at site.
11. As far as possible, contractor has to maintain supply of cement of only one brand &
grade through out the work and on account of closer/shortage of approved brand,
cement of other brand in accordance of condition No. (1) will be allowed by Engineer
12. Contractor will be allowed to carry out work only after physical verification of cement
brought at site.
13. Contractor shall have to use PPC (Fly Ash based) preferably as per the relevant I.S.
14. The cement consumption will be considered as per the standardized norms of state
P.W.D. and accordingly the required quantity of cement shall have to be brought by the
contractor and has to use the cement accordingly. Contractor should not use less than
the prescribed quantities of cement even in the case of mix design recommends lower
quantity. Nothing will be paid extra for over consumption.
Signature Of Contractor Addl. Chief Engineer (P),
Approved name of Manufacturers: Allowing to use steel / cement being supplied by
contractors in civil works
The list of adopting cement and steel of companies / suppliers / manufacturers are shown be-
Following companies / brands are approved for providing and supplying the cement and steel
to be used in concerned tender works where the contractor has to bring the same at his own
(A) Name of Manufacturer of Cement
1. Narmada Cement Company Ltd.
2. Ambuja Cement Co. Ltd.
3. Saurashtra Cement & Chemicals.
4. Siddhi Cement
6. L & T Cement (Ultratech)
7. Shri Digvijaya Cement Co. Ltd.
8. Binani Cement
9. Sanghi Cement
10. Laxmi Cement
11. Vikram Cement
12. Jay Pee Cement
13. HI Bond Cement
14. Coromondal King Cement
15. A.C.C. Cement
16. Wonder Cement
17. Kamal Cement
(B) Names of Manufacturer / Supplier of structural Steel / Coils / Bars etc. for
the structural / Pipes / reinforcement etc.
Steel Authority of India
Tata Iron & Steel Co. Ltd.
M/s. Nilkanth Concast PVT. Ltd.
M/s. Hans Inspat Ltd.(Barnala TMT)
Kamdhenu TMT Sariya
ASR Multi Metals Pvt. Ltd.
Vishal ISPAT, Vapi(Sarv Shakti TNT Bar)
Ashiana Rolling Mills,(Friend steel TMT bar)
Gujarat NRE Cock Ltd., Kutch(NRE TMT Bar)
Utkarsh Bar PVT Ltd., Rajkot.(Utkarsh TMT Bar)
M/s. H. k. Ispat Private Limited (KOTHI GOLD 500 TMT Bar)
Structural Steel
1. Steel Authority of India
2. Tata Iron & Steel Co. Ltd.
3. ESSAR Steel Ltd.
5. Shah Alloys Ltd, Ahmedabad.
(C) Instruction for Materials :
1. The contractor shall submit entry details of cement & steel along with challan
duly endorsed by Security Department to E.I.C. for record and verification with
each R.A. Bill.
(a) All the Cement (53 / 43 grade) should be as per relevant IS (latest revision)
(b) Steel with necessary Certificate
(c) All material shall be got tested in Govt. approved laboratory by contractors at
their cost and after acceptance only material will be allowed to be utilized.
SIGNATURE OF CONTRACTOR Addl. Chief Engineer (P),
(With Rubber Stamp & Date) DGVCL Corporate Office, Surat.
Name of work : ARC for Civil Maintenance work for "Execution of misc. mainten-
nace work from below mention items list for Corporate office Building and campus,
Canteen building, Training centre building under Corporate office DGVCL.
Description Unit Rate
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the ex-
cavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting
2 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(B) Dense or Hard soil
Excavation for foundation upto 1.5 m depth including sorting
3 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(C) Hard Murrum
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the ex-
cavated stuff upto 50 Meter lead.(D) Soft rock not requiring
Excavation for foundation upto 1.5 m depth including sorting
5 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(E) Hard Rock
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(B) Dense or
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(C) Hard
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead. (D) Soft
rock not requiring Blasting
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(E) Hard
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm.
in depth consolidating each disposited layer by ramming and
Filling in plinth with sand under floors including watering
11 ramming, consolidating and dressing complete
Filling in foundation and plinth with murrum or selected soil in
12 layers of 20cm. thickness including watering, ramming and
consolidating etc. complete.
Filling in foundation and plinth with brick Bats Chhara in layers
13 of 20cm. thickness including watering, remming and consoli- Cu.mt
dating etc. complete.
Excavation for foundation upto 1.5 m depth including sorting
14 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting
15 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(B) Dense or Hard soil
Excavation for foundation upto 1.5 m depth including sorting
16 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(C) Hard Murrum
Excavation for foundation for depth from 3.0 m to 5.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(A) Loose or
Excavation for foundation for depth from 3.0 m to 5.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(B) Dense or
Excavation for foundation for depth from 3.0 m to 5.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing of the excavated stuff upto 50 Meter lead.(C) Hard
Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm.
in depth consolidating each disposited layer by ramming and
Filling in plinth with sand under floors including watering
21 ramming, consolidating and dressing complete
Filling in foundation and plinth with murrum or selected soil in
22 layers of 20cm. thickness including watering, ramming and Cu.mt
consolidating etc. complete.
Filling in foundation and plinth with brick Bats Chhara in layers
23 of 20cm. thickness including watering, remming and consoli- Cu.mt
dating etc. complete.
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles)
and getting out the soil and disposal of the surplus excavated
soil as directed within a lead of 50 Meter for following diame-
ter of pipes.(i)200 mm
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles)
and getting out the soil and disposal of the surplus excavated
soil as directed within a lead of 50 Meter for following diame-
ter of pipes.(ii) 250 m
Extra for under reaming inside the bore Holes for under
26 reamed piles of following Diameter.(i) 200 mm
Extra for under reaming inside the bore Holes for under
27 reamed piles of following Diameter.(ii) 250 mm
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the ex-
cavated stuff upto 50 Meter lead.(A) Loose or soft soil (EXE-
CUTED WITH MANUAL LABOUR)
Excavation for foundation upto 1.5 m depth including sorting
29 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(B) Dense or Hard soil
Excavation for foundation upto 1.5 m depth including sorting
30 out and stacking of useful materials and disposing off the ex- Cu.mt
cavated stuff upto 50 Meter lead.(C) Hard Murrum
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(A) Loose or
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(B) Dense or
Excavation for foundation for depth from 1.5 m to 3.0 m in-
cluding sorting out and stacking of useful materials and dis-
posing off the excavated stuff upto 50 Meter lead.(C) Hard
Providing and laying in foundation and plinth / under floors
lime concrete with hand broken stone aggregates 40mm nom-
inal size and 40% mortar comprising of 1-Lime putty : 2-Fine
sand and curing complete excluding cost of formwork.
Providing and laying in foundation and plinth / under floors
lime concrete with graded brick aggregates 40 mm nominal
size and 40% mortar comprising of 1-Limeputty : 2-Fine sand
and curing completeexcluding cost of formwork.
Providing and laying cement concrete 1:3:6 (1-Cement : 3-
coarse sand : 6- hand broken stone aggregates 40 mmnomi-
nal size) and curing complete excluding cost of formwork in
(A) Foundation and Plinth
Providing and laying cement concrete 1:4:8 (1- Cement : 4-
coarse sand : 8- hand broken stone aggregates 40 mm nomi-
nal size) and curing complete excluding cost of formwork in
(A) Foundation and Plinth
Providing and laying cement concrete 1:3:6 (1- Cement : 3-
Coarse sand : 6- crushed stone aggregates 20 mm nominal
size) and curing complete including cost of formwork in (A)
Wall Caps / Coping
Providing and laying cement concrete 1:5:10 (1- Cement : 5-
Coarse sand : 10- hand broken stone aggregates 40 mm nom-
inal size) and curing complete excluding cost of formwork in
(A) Foundation and Plinth
Providing and laying cement concrete 1:3:6 (1- Cement : 3-
Coarse sand : 6- Graded brick bat aggregate 40mm normal
size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
Providing and laying cement concrete 1:4:8 (1- Cement : 4-
Coarse sand : 8- Graded Brick bats aggregate 40mm normal
size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
Providing and laying cement concrete 1:2:4 (1- Cement : 2-
Coarse sand : 4- graded stone aggregates 20 mm nominal
size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
Providing and laying cement concrete 1:2:4 (1- Cement : 2-
Coarse sand : 4- graded stone aggregates 20 mm nominal
43 size) and curing complete excluding cost of formwork in Cu.mt
(B)Independent piers, columns, and pillars, upto floor two lev-
Providing and laying cement concrete work 1:2:4 (1- Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm nominal
44 size) and curing complete excluding cost of formwork and re- Cu.mt
inforcement for reinforced concrete work in (A) Foundations,
footings, Base or columns and Mass concrete
Providing and laying cement concrete work 1:2:4 (1- Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm nominal
size) and curing complete excluding cost of formwork and re-
inforcement for reinforced concrete work in (B) Slabs, landing,
shelves, Balconis , Lintels, Beams, Girders and Cantilever upto
floor two level.
Providing TMT Bar FE 415 reinforcement for R.C.C. work in-
46 cluding bending, binding and placing in position complete upto Kg
floor two level
Extra for additional lift of reinforcing steel for all R.C.C. work
above floor two level.
roviding throating or plaster drip and moulding to R.C.C.
Providing upto floor two level precast cement concrete jali or
grill 1:2:4 mix (1- Cement : 2- coarse sand : 4-graded stone
49 aggregate 6mm nominal size) reinforced with 1.6 mm dia. Mild Sqm
steel wire including roughening,cleaning, fixing and finishing in
cement mortar 1:3 and curing complete. (A) 50mm thick
Providing upto floor two level precast cement concrete jali or
grill 1:2:4 mix (1- Cement : 2- coarse sand : 4-graded stone
50 aggregate 6mm nominal size) reinforced with 1.6 mm dia. Mild Sqm
steel wire including roughening,cleaning, fixing and finishing in
cement mortar 1:3 and curing complete.(E) 100mm thick
Providing and laying controlled cement concrete M.150 for
curing complete excluding cost of formwork and reinforcement
for reinforced concrete work in (B) Walls, from top of founda-
tion level upto floor two level
Providing and laying controlled cement concrete M.150 for
curing complete excluding cost of formwork and reinforcement
52 for reinforced concrete work in (C) Slabs, landing, shelves, Cu.mt
Balconies, Lintels, Beams, Girders and Cantilever upto floor
Providing and laying controlled cement concrete M.150 for
curing complete excluding cost of formwork and reinforcement
for reinforced concrete work in (D) Columns, Pillars posts and
struts upto floor two level.
Providing and laying controlled cement concrete M.200 and
curing complete excluding the cost of formwork and rein-
forcement for reinforced concrete work in (A) Foundations,
footings, Base of columns and Mass concrete
Providing and laying controlled cement concrete M.200 and
curing complete excluding the cost of formwork and rein-
forcement for reinforced concrete work in (B) Walls, from top
of foundation level upto floor two level
Providing and laying controlled cement concrete M.200 and
curing complete excluding the cost of formwork and rein-
56 forcement for reinforced concrete work in (C) Cu.mt
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and
Cantilever upto floor two level.
Providing and laying controlled cement concrete M.200 and
curing complete excluding the cost of formwork and rein-
forcement for reinforced concrete work in (D) Columns, Pillars
posts and struts upto floor two level.
Providing and laying controlled cement concrete M.250 and
curing complete excluding the cost of formwork and rein-
forcement for reinforced concrete work in (A) Foundations,
footings, Base of columns and Mass concrete.
Providing and laying controlled cement concrete M.250 and
curing complete excluding the cost of formwork and rein-
forcement for reinforced concrete work in (B) Walls, from top
of foundation level upto floor two level
Providing and laying controlled cement concrete M.250 and
curing complete excluding the cost of formwork and rein-
60 forcement for reinforced concrete work in (C) Cu.mt
Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and
Cantilever upto floor two level.
Providing and laying controlled cement concrete M.250 and
curing complete excluding the cost of formwork and rein-
forcement for reinforced concrete work in (D) Columns, Pillars
posts and struts, upto floor two level.
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(A)
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B)
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(C)
Extra for brick work in superstructure above plinth level upto
floor two level (A) Modular
Extra for brick work in superstructure above plinth level upto
floor two level (B) Conventional
Extra for brick work in superstructure above plinth level upto
floor two level(C) Fly Ash Bricks
Half brick masonry in common brunt clay building bricks hav-
ing crushing strength not less than 35 Kg/Sq.Cm. in Cement
mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and
plinth (A) Modular
Half brick masonry in common brunt clay building bricks hav-
ing crushing strength not less than 35 Kg/Sq.Cm. in Cement
mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and
plinth (B) Conventional
Half brick masonry in common brunt clay building bricks hav-
70 ing crushing strength not less than 35 Kg/Sq.Cm. in Cement Sqm
mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and
plinth (C)Fly Ash Bricks
Extra for half brick masonry in superstructure above plinth
71 level upto floor two level. (A) Modular
Extra for half brick masonry in superstructure above plinth
72 level upto floor two level. (B) Conventional
Extra for half brick masonry in superstructure above plinth
73 level upto floor two level. (C)Fly Ash Bricks
Precast concrete block masonry (including quoin blocks jamb
blocks closer etc.) with solid concrete blocks of approved size
74 made of cement concrete 1:3:6 mix (1- Cement : 3 coarse Cu.mt
sand: 6- graded stone aggregates of 20 mm and down grade)
in foundation and plinth cement morter 1:6
Providing and fixing 35 mm thick shutters for Doors, windows
and clear story windows including anodised alluminium butt
hinges with necessary screws.(A) Indian Teak Wood (1) Fully
Providing and fixing 35 mm thick shutters for Doors, windows
and clear story windows including anodised alluminium butt
hinges with necessary screws. (A) Indian Teak Wood (ii) Fully
Providing and fixing 35 mm thick shutters for Doors, windows
and clear story windows including anodised alluminium butt
hinges with necessary screws. (A) Indian Teak Wood(iii) Partly
panelled and partly glazed.
Providing and fixing 25 mm thick shutters for cupboards etc.
78 including anodised alluminium butt hinges with necessary
screws. (A) Indian teak wood. (ii) Fully Glazed.
Precast terrzo tiles 22mm thick with white, Black or white and
black marble chips of sizes upto 6mm, laid in floors, treads of
steps and landings on a bed of 25mm average thickness of
79 lime mortar 1:6 jointed with neat cement slurry mixed with Sqm
pigment to match the shade of tiles including rubbing and pol-
ishing complete with precast tiles of (1) Light shades using
Precast terrzo tiles 22mm thick with white Black or white and
black marble chips of sizes upto 6mm laid in floors, treads of
steps and landings on a bed of 25mm average thickness of
80 lime mortar 1:6 jointed with neat cement slurry mixed with Sqm
pigment to match the shade of tiles including rubbing and pol-
ishing complete with precast tiles of (1) Dark shades using
ordinary cement
Providing and laying white glazed tiles 6mm thick in flooring
treads of steps and landing laid on a bed of 12mm thick ce-
ment mortar 1:3 (1-cement : 3-coarse sand ) finishing with
flush pointing in white cement.
Providing and laying Ceramic tiles 6mm thick in flooring treads
of steps and landing laid on a bed of 12mm thick cement mor-
tar 1:3 (1-cement : 3-coarse sand ) finishing with flush point-
ing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24''
in flooring treads of steps and landing laid on a bed of 12mm
thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing
with flush pointing in white cement.
Providing and laying white glazed tiles 6mm thick in skirting
84 risers of steps and dedo on 10mm thick cement plaster 1:3 (1- Sqm
cement : 3-coarse sand) and jointed with white cement slurry
Providing and laying Ceramic tiles 6mm thick in skirting risers
85 of steps and dedo on 10mm thick cement plaster 1:3 (1- Sqm
cement : 3-coarse sand) and jointed with white cement slurry
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24''
in skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting
87 risers of steps and dedo on 10mm thick cement plaster 1:3 (1- Sqm
cement : 3-coarse sand) and jointed with white cement slurry
Providing and laying marble stone slab flooring over 20mm
(average)base of cement mortar 1:6 (1-cement : 6 coarse
88 sand) or L.M. 1:1.5(1- lime putty : 1.5 - coarse sand) laid and Sqm
jointed with gray cement slurry including rubbing and polish-
ing complete. (A) Marble slab 25mm thick
Providing and laying polished Kota stone slab flooring over
20mm (Average) thick base of cement mortar 1:6 (1-cement :
6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand)
laid over and jointed with grey cement slurry mixed with pig-
ment to match the shade of slab including rubbing and polish-
ing etc. complete. (A) 25mm thick
Providing and laying polished Kota stone slab flooring over
20mm (Average) thick base of cement mortar 1:6 (1-cement :
90 6-coarse sand) or L.M. 1.1.5 laid over and jointed with grey Sqm
cement slurry including rubbing and polishing etc. complete.
(B) 30 mm thick
Providing and laying polished kota stone slab 25mm thick in
risers of steps,skirting Dedo and pillars laid on 10mm thick
91 cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed Sqm
with gray cement slury mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete.
Providing and fixing pre-cast concrete kerb stone of gray ce-
ment based concrete block 30cm length,30cm height and
92 15cm thick of M250 grade concret as per approved design and Rmt
including excavation for fixing in proper line and level,filling
the joint with C:M 1:3 (1cement:3fine sand) etc complete.
Providing and fixing pre-cast Rubber Dye / steel Dye inter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
93 per approved design Confirming to IS 15658 : 2006 including Sqm
35 mm Sand layer for levelling and filling the joint with sand in
proper line and level as per guidlines of IRC : SP 63-2018 etc.
Providing and laying broken chine mosaic flooring for terrace
using 12 mm to 20 mm broken pieces of glazed tiles to be laid
over cement mortar 1:3 to plain or slope and to be tempered
94 to bring mortar creme out upto surface using white cement Sqm
including rounding off junctions and extending them upto
cm along the wall,clearing with water and oxalic acid etc. as
Providing corrugated G.I. sheet of class-3 roofing fixed with
glavanished iron J or L Hooks, Bolts and nuts 8mm diameter
95 with bitumen and G.I. limpet washer or G.I. limpet washer. Sqm
filled with white lead complete excluding the cost of purlins,
Rafters and Trusses.(1) 0.80 mm thick sheet.
Providing and fixing on wall face C.I. Rain water pipe including
filling the joints with spun yarn soaked in neat cement slurry
and cement mortar 1:2 (1- Cement : 2-fine sand) (A) 75 mm
Providing and Fixing 6 mm thick Lexan Polycarbonate multi
wall roofing sheet fixed with hilti screw and rubber silicon
sealer and alluminium strip of size 50 x 3 mm etc complete as
directed by Engineer in charge.
Providing and fixing eco-friendly light weight calcium silicate
false ceiling tiles having Tegular edge & 15 mm Thick Densi-
fied edges on the Tile Periphery for Extra Strength The Light
weight calcium silicate ceiling tiles shall have , light reflection
85% non-combustible as per B.S. 476 part IV, 100% humidity
resistance and also having thermal conductivity0.043° w/m
KC.for the best thermal Insulation . The Light weight calcium
Silicate tile shall be of approved texture Fine fissured/ Spin-
tone/Cosmos having NRC value of 0.5 & Globe having NRC
value of 0.75 NRC or equivalent of size 595 X 595 mm to be
laid on true horizontal level suspended inter locking metal grid
of hot dipped galvanized steel sections (galvanizing @120
grams per sqm including both side) consisting of main ‘T’ run-
ner suitably spaced at joints to get required length and size of
24X38mm made from 0.30 mm thick (minimum) sheet,
1200mm centre to centre, and cross ‘T’ of size 24X28mm
made out of 0.33mm (Minimum) sheet spaced 1200mm along
spaced between main ‘T’ at 600mm centre to centre to form
agrid of 1200X600mm and secondary cross ’T’ of length
600mm and size 24x28mm made of 0.30 mm thick (Minimum)
sheet to be interlocked at middle of the 1200X600mm panel to
98 form grid of size 600X600mm resting on periphery Sqm
walls/partitions on a perimeter wall angle pre-coated steel of
size (24X24X3000mm made of 0.40mm thick (minimum) sheet
with the help of rawl plugs at 450mm centre to centre with
25mm long dry wall screws @ 230mm interval and laying
15mm thick Densified edges light weight calcium silicate ceil-
ing tiles of approved texture (Fine Fissured/Cosmos/Spintone)
in the grid including, cutting /making opening for services like
diffusers, grills, light fittings, fixtures, smoke detectors etc.,
wherever required, Main ‘T’ runners to be suspended from
ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to
ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm
G.I. adjustable rods with galvanized steel level clips of size
85X30X0.8mm, spaced at 1200mm centre to centre long main
‘T’ bottom exposed with 24mm of all T-sections shall be pre-
painted with polyester baked paint, for all heights, as per
specifications, drawings and as directed by engineer-in-
charge.Note:- Only calcium silicate false ceiling area will be
measured from wall to wall. No deduction shall be made for
exposed frames/opening (cut outs) having area less than
sqm. The calcium silicate ceiling tiles shall have NRC. Value of
0.50 (Minimum) for Fine fissured/Spintone/Cosmos and
NRC for Globe, light reflection 85% non-combustible as per
B.S. 476 part IV, 100% humidity resistance and also having
thermal conductivity. 0.043° w/m KC.for the best thermal In-
Providing 10mm thick cement plaster in single coat on
brick/concrete walls for interior plastering upto floor two level
and finished even and smooth in (i)Cement mortar 1:3 (1-
Providing 15mm thick cement plaster in single coat on Rough
(Similar)side of single or half brick walls for interior plastering
upto floor two level and finished even and smooth in (i) Ce-
ment mortar 1:3 (1-cement:3-sand)
Providing 20mm thick cement plaster in single coat on single
or half brick walls for interior plastering upto floor two level
and finished even and smooth in (i) Cement mortar 1:3 (1-
Extra over items 58 to 64 for finishing with a floating coat of
neat cement slurry.
Distempeing (Two coats) with oil bound washable distemper
of approved brand and manufacture and of required shade on
wall surfaces to give an even shade, over and including a
103 priming coat with alkali resistance primer of approved brand Sqm
after thoroughly brushing the surface and other foreign matter
and also including preparing the surface even and sand par-
Distempeing (One coats) with oil bound washable distemper
of approved brand and of required shade on wall surfaces to
give an even shade, after thorouhly brushing the surface clean
of all grease dirt, loose pieces of scales and also including dis-
tempering with oil bound washable distemper of preparing the
surface even and smooth.
Extra over Item 44 to 46 for every subsequent coat of ap-
proved brand and manufacture.
Finishing wall with water proofing cement paint of on wall sur-
faces (Two coats) to give an approved brand and manufacture
106 and of required shape even shade after thoroughly brushing Sqm
the surface to remove all dirt and remains of loose powered
Extra over Item 51 for every subsequent coat of water proof-
107 ing cement paint of approved brand and manufacture.
Wall painting (two coats) with plastic emulsion paint of ap-
proved brand and manufacture on undecorated wall surface to
108 give an even shade including throughly brushing the surface Sqm
free from mortar droppings and other foreign matter and sand
papered smooth.
Extra over item 57 for every subsequent coat of wall painting
109 with plastic emulsion pain of approved brand.
Applying priming coat over new steel and other metel surface
after and including preparing the surface by throughly clean-
110 ing, oil,grease, dirt and other foreign matter and scoured with Sqm
brushes fine steel wood, scrapers and sand paper with ready
mixed priming paint brushing red lead.
Painting two coats (excluding priming coat) on new steel and
111 other metal surface with enamel paint, brushing, interior to Sqm
give an even shade including cleaning the surface an even
shade including cleanicn the surface of all dirt, dust and other
foreign matter.
Painting one coats (excluding priming coat) on previously
painted steel and other metal surface with enamel paint,
brushing to give an even shade including cleaning the surface
of all dirt, dust and other foreign matter.
Painting lines, deashes, arrows, letters etc on roads, Air fields
and like in two coats with road marking paint, brushing includ-
ing cleaning the surface of all dirt, dust and other foreign mat-
ter. (i) Over 10cm in width
Painting lines, deashes, arrows, letters etc on roads, Air fields
and like in two coats with road marking paint, brushing includ-
ing cleaning the surface of all dirt, dust and other foreign mat-
ter. (ii) Upto 10 cm in width
Demolition including stacking of serviceable materilas and dis-
115 posal of unserviceable materials with all lead and lift. (i) R.C.C. Cmt
Demolition of Brick work and stone masonry including stacking
116 of serviceable materilas and disposal of unserviceable materi- Cmt
als with all lead and lift.(ii) In Cement Mortar
Dismentaling tiled of stone floors laid in mortar including
117 stacking of serviceable materilas and disposal of unserviceable Sqm
materials with all lead and lift.
Dismentaling of sheet roofing including ridges, Hips, Valleys,
Gutters etc. stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(i) G.I.sheet roof-
ismentling steel work including distempering and stacking the
materials with all lead and lift.
Dismentling doors, windows, ventilators etc. (wood or steel)
shutters including chowkhats architraves, holdfasts and other
attachment etc. complete and stacking them within all lead
and lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling doors, windows, ventilators etc. (wood or steel)
shutters including chowkhats architraves, holdfasts and other
attachment etc. complete and stacking them within all lead
and lift.(ii) Exceeding 3 Sq.M. in area.
Dismentling C.I. pipes G.S.W.pipes abd A.C. rain water pipes
122 with fittings and clamps including stacking the materials with Rmt
all lead and lift ( for any dia, of pipe)
Dismantling santtary fittings like wash basin . W.C. pan Indian
123 and European type, flushing tank etc. including stacking the Each
materials with all lead and lift.
Scraping oil paint from steel and other metal surface and mak-
124 ing the surface even (with Hand Scraping.)
Removing and scraping of old deteriorated plaster of any
thickness fromm wall / R.C.C member including stacking of
serviceable material and disposal of unserviceable from site of
work with all lead and lift
Providing and fixing PUF Insulated continueous sandwich pan-
els for roofs of total thickness not less than 30 mm made out
from continue line method.Panel shall have 0.5 mm thick pre
coated GI sheet on both side of Polyurethane foam with ex-
ternal face being corrugated in shape for GI and PU foam both
material.The crest height of the panel shall be of 35mm mini-
mum wiht 250mm c/c pitch. The Precoated sheet shall be of
minimum 240 mpa steel grade confirming to IS 14246:1995
and shall have zinc coating of 120 gsm as per IS:277 , 5-7 mi-
crons epoxy primer on both side of the sheet and polyester
top coat 15-18 micron.The PPGI Sheet shall have protective
guard film of minimum 25 microns to avoid scratches wihile
trasportation.The roof panels are laid over a frame work of
trusses, columns and purlins fixed using 90mm self drilling
bolt with rubber washer including all types of flashings. PU
Foam must be self-extinguishing, fire retardant type having
minimum density of 40 Kg/Cu.mt.( +, - 2 Kgs) including
0.25mm craft paper edging,self tapping screws of required
length and nos.etc complete as per structural design and di-
rection of Engineer-in-charge.
Providing and fixing of Bottom and top U track for closing of
end joints for cut PUF panels of size of 52mm x 30mm with
5mm lipping on Both edges. The U track shall be made out of
0.5 mm thick pre coated GI sheet.The Precoated sheet shall
be of minimum 240 mpa steel grade confirming to IS
14246:1995 and shall have zinc coating of minimum 120 gsm
127 as per IS:277:1992 , 5-7 microns epoxy primer on both side of Rmt
the sheet and polyester top coat 15-18 micron. The PPGI
Sheet shall have plastic protective guard film of minimum
microns to avoid scratches during transportation. The U track
shall be fixed with suitable POP rivet with wall roof panels and
plinth with Expandable fastners with minimum spacing of
mm c/c. The Utrack shall be fixed
Cutting out cracks of roof terrace to V- section , cleaning out,
128 wetting , grouting with cement and sand slurry 1:3 (1-cement Rmt
Cutting out cracks roof terrace to V-Section cleaning out and
129 filling solidly with a hot mixture of bitumen and clean dry sand Rmt
(1:1 by weight)
Providing and fixing 1.20 Metre high fencing with 2.0 Metre
long M.S. Angle posts 40mm x 40 mm x6 mm and oil painting
3 coats fixed at 2.5 Mt,C/c. with five Horizontan lines and two
130 diagonals of galvanised steel barbed wire weighting 9.38 Kg. Rmt
per 100 Metre, strained and fixed to posts with G.I,staples in-
cluding fixing the postsin ground with 0.5 M x 0.5.M x 0.5 M.
block in C.C1:5:10 etc complete.
Constructing a cooking platform 60 cm. width and 70 cm high
resting on B.B.Masonry walls 23 cm.thick in C.M.(1:6) with (i)
131 Fixing or precast R.C.C.1:2:4) 8 cm. thick slab with marble Rmt
chips set in C.M. (1:6) (6mm thick terrazo) with plastering on
exposed faces walls in C.M. (1:4) etc complete
Applying general insecticide pest control treatment to floors,
cupboards etc including labour materials etc. complete. Using
132 Imidacloprid 30.5 SCas Per IS 6313 part -II( (0.075% concen- Sqm
tration by mass) is recommended 10.5ml chemical diluted with
5 liters of water application 0.5 litre chemical /Sqm of surface
is recommended as per I.S.
Carring out plinth treatment to post construction / existing
structure by spraying chemical solution for termite control
treatment including labour and material consistment with I.S.I
specification. Using Chlordene and Chiorpurfiles 20 EC. As Per
133 6131_paret-II Consentration Weight one percent is recom- Sqm
mended i.e one litre 20 EC chemical emulsion with 19 liter
give 1 % concrentration inclusive of one litre chemical emul-
sion appication at the rate of 5 Litre chemical / Sqm of surface
is recommended as per I.S
Providing erecting and fixing double coated ISI water tank of
134 required capacity each with all necessary fittings and connec- Litre
tion etc. complete on terrace
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside Dia.
135 Low densidy, complete with special falnge compression type Rmt
fittings, wall clipsetc. including making good the wall ceiling
and floor.(A) 20mm
Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside Dia.
136 Low densidy, complete with special falnge compression type Rmt
fittings, wall clipsetc. including making good the wall ceiling
and floor.(B) 25mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside Dia.
137 Low densidy, complete with special falnge compression type Rmt
fittings, wall clipsetc. including making good the wall ceiling
and floor.(C) 32mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside Dia.
138 Low densidy, complete with special falnge compression type Rmt
fittings, wall clipsetc. including making good the wall ceiling
and floor.(D) 40mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure polythene pipes of the following outside Dia.
139 Low densidy, complete with special falnge compression type Rmt
fittings, wall clipsetc. including making good the wall ceiling
and floor.(F) 75mm
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2
working pressure poluthene pipes of the following outside Dia.
140 Low densidy, complete with special falnge compression type Rmt
fittings, wall clipsetc. including making good the wall ceiling
and floor.(G)110 mm
Providing and fixing cast iron spigot and socket soil, waste and
141 ventilating pipes of the following nominal size.(B) 75mm dia.
Providing and fixing cast iron spigot and socket soil, waste and
142 ventilating pipes of the following nominal size.(C) 100mm dia
roviding and fixing in position cowel went to pipes.(B) 75mm
Providing and fixing in position cowel went to pipes.(C)
Providing and fixing cast iron (Spun) Nahni trap of the follow-
ing nominal diameter of self cleaning design with C.I. screaed
down or higned grating including cost of cutting and making
good the walls and floor 100mm inlet and 50mm outlet.(C)
Providing and fixing water closet squatting Pan (Indian type
W.C. Pan) size 580mm (Earthwork, bed concrete, foot reste
and trap to be measured and paid for separately) (A) Vitreous
China.(I) Long pattern = White colour
Providing and fixing wsh down water closet (European type,
W.C. Pan) with integral P or S trap including jointing the trap
147 with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand) Each
(Seal and cover to be measured and paid for separately)(A)
vitreous China Pattern :(i) in white colour
Providing and fixing 100mm size P or S trap for water closet
squatting pan including jointing the trap with the pan and soil
pipe in cement Mortar 1:1 (1-Cement : 1-Fine sand)(A) Vitre-
Providing and fixing G.I. inlet connection for flush pipe with
Providing and fixing washbasin with single hole for pillar tap
with C.I. or M.S. brackets painted white including sutting holes
150 and making good the same but excluding fittings.(A) Vitreous Each
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In
Providing and fixing Kitchen sink with C.I. or M.S. brackets,
painted white including cutting holes in walls and making good
the same but excluding fittings. (C) Vitreous China Sink.(i)
600mm x 450mm x 150mm size
Providing and fixing C.P. brass waste for washbasin or sink.
Providing and fixing M.I. fisher union for washbasin or sink.
Providing and fixing 600mm x 450mm bevelled edge mirrror of
superior glass mounted on 6mm thick A.C. sheet or plywood
sheet and fixing to wooden pluge with C.P. brass screws and
Providing and fixing C.P. brass towel rail comlete with C.P.
155 brass brackets fixed to wooden plugs with C.P. brass Each
scews.(B) 600mm x 20mm size
156 Providing and fixing toilet paper holder.(A) C.P. Brass Each
Providing and fixing screw down bib taps of following size.(A)
157 Brass screw down bib tap polished bright. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(A)
158 Brass screw down bib tap polished bright. (ii) 20mm dia.
Providing and fixing screw down bib taps of following size.(B)
159 Brass chromium plated screws down Bib Tap. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(B)
160 Brass chromium plated screws down Bib Tap. (ii) 20mm dia.
Providing and fixing screw down bib taps of following size.(C)
161 Gun metal screw down bib tap. (i) 15mm dia.
Providing and fixing screw down bib taps of following size.(C)
162 Gun metal screw down bib tap. (ii) 20mm dia.
Providing and fixing pillar tap, capstan head, screw down high
163 pressure with screws, shanks and back nuts. (i) 15mm dia.
Providing and fixing pillar tap, capstan head, screw down high
164 pressure with screws, shanks and back nuts. (ii) 20mm dia
165 Providing and fixing brass screw down stop tap.(A) 15mm dia. Each
166 Providing and fixing brass screw down stop tap.(B) 20mm dia. Each
167 Providing and fixing brass screw down stop tap.(C) 25mm dia. Each
Providing and fixing Gun metal check or non-return fullway
wheel valve.(A) 15mm dia.
Providing and fixing Gun metal check or non-return fullway
wheel valve.(B) 20mm dia.
Providing and fixing Gun metal check or non-return fullway
wheel valve.(C) 25mm dia.
Providing and fixing Gun metal check or non-return fullway
wheel valve.(D) 32mm dia.
Providing and fixing chromium plated brass half trun flush
172 cock of approved quality including fixing in pipe line etc. com- Each
plete.(i) 20mm dia.
Providing and fixing chromium plated brass half trun flush
173 cock of approved quality including fixing in pipe line etc. com- Each
plete.(ii) 25mm dia.
Providing and fixing chromium plated brass half trun flush
174 cock of approved quality including fixing in pipe line etc. com- Each
plete.(iii) 32mm dia
Providing and fixing Urinal or approved quality including
conecting the Urinal with waste pipe , tap etc. complete.(A)
White earthenware flat back or corner type size 430mm x
Providing and fixing Urinal of approved quality including con-
176 nection with trap and with integral longitudinal flush pipe.(A) Each
Squating plate pattern white earthenware 550mm x 300mm.
Providing and fixing ball cock of approved. quality as di-
rected.(A) Copper Metal (i) 25mm dia.
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size
178 having weight not less than 35Kg.
Providing and fixing G.I. Rain water spout of 50mm dia. and
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foun-
180 dation (NSF) seal for potable water of following dia. nominal Rmt
bore tube fittings and clamps including making good the wall,
ceiling and floor etc. complete.[A] 15 mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foun-
181 dation (NSF) seal for potable water of following dia. nominal Rmt
bore tube fittings and clamps including making good the wall,
ceiling and floor etc. complete. [B] 20 mm
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foun-
182 dation (NSF) seal for potable water of following dia. nominal Rmt
bore tube fittings and clamps including making good the wall,
ceiling and floor etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foun-
183 dation (NSF) seal for potable water of following dia. nominal Rmt
bore tube fittings and clamps including making good the wall,
ceiling and floor etc. complete. [D] 32mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foun-
184 dation (NSF) seal for potable water of following dia. nominal Rmt
bore tube fittings and clamps including making good the wall,
ceiling and floor etc. complete. [E] 40mm.
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation Foun-
185 dation (NSF) seal for potable water of following dia. nominal Rmt
bore tube fittings and clamps including making good the wall,
ceiling and floor etc. complete. [F] 50mm.
Providing laying and jointing in true line and level 15mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the
186 wall with the help of clamp at every two metre C/C or shall be Rmt
concealed as directed including necessary fittings etc. includ-
ing testing of pipe and joints and fixing the same with adhe-
sive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the
187 wall with the help of clamp at every two metre C/C or shall be Rmt
concealed as directed including necessary fittings etc. includ-
ing testing of pipe and joints and fixing the same with adhe-
sive solvent, including cost of all materials.
Providing laying and jointing in true line and level 32mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the
188 wall with the help of clamp at every two metre C/C or shall be Rmt
concealed as directed including necessary fittings etc. includ-
ing testing of pipe and joints and fixing the same with adhe-
sive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the
189 wall with the help of clamp at every two metre C/C or shall be Rmt
concealed as directed including necessary fittings etc. includ-
ing testing of pipe and joints and fixing the same with adhe-
sive solvent, including cost of all materials
Providing laying and jointing in true line and level 50mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the
190 wall with the help of clamp at every two metre C/C or shall be Rmt
concealed as directed including necessary fittings etc. includ-
ing testing of pipe and joints and fixing the same with adhe-
sive solvent, including cost of all materials.
Providing, laying and jointing in true line and level 160 diame-
tre U.P.V.C (Type B) conforming to IS 13592-1992 with one
end plain and other end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with
191 rubber lubricant, pipe shall be fixed on wall using of PVC Rmt
clamp of the size 160 mm diametre x 210 mm length x
mm heigh at every 2000 mm center to center or shall be con-
cealed in walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all ma-
Providing, laying and jointing in true line and level 110 diame-
tre U.P.V.C (Type B) conforming to IS 13592-1992 with one
end plain and other end socketed with rubber ring, & fittings
conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of PVC
clamp of the size 110 mm diametre x 149 mm length x
mm heigh at every 2000 mm center to center or shall be con-
cealed in walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all ma-
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
100 mm diameter with jali of the following nominal diameter
of self cleansing design with C.I scread down or hinged grat-
ing including the cost of cutting and making good the walls.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
75 mm diameter with jali of the following nominal diameter of
self cleansing design with C.I scread down or hinged grating
including the cost of cutting and making good the walls.
Providing and laying Cement concrete 1:5:10 (1-Cement : 5-
Fine sand :10-Graded stone aggregate 40mm nominal size)
195 bedding for stoneware pipes of following internal diameters Rmt
with necessary formwork and curing complete.(A) 100 mm
dia. (112 mm Ave.bed thickness)
Providing and laying Cement concrete 1:5:10 (1-Cement : 5-
Fine sand :10-Graded stone aggregate 40mm nominal size)
196 bedding for stoneware pipes of following internal diameters Rmt
with necessary formwork and curing complete.(B) 150mm dia.
(166mm Ave. bed thickness)
Providing and laying lime concrete 1:2:4 (1-Lime putty :2-Fine
samd : 4-Graded brick aggregates 40mm nominal size) bed-
197 ding for stoneware pipes of following internal diameters with Rmt
necessary formwork and curing complete.(A) 100 mm dia.
300mm width (112 mm Ave.bed thickness)
Providing and laying lime concrete 1:2:4 (1-Lime putty :2-Fine
samd : 4-Graded brick aggregates 40mm nominal size) bed-
198 ding for stoneware pipes of following internal diameters with Rmt
necessary formwork and curing complete.(B) 150mm dia.
450mm width (166mm Ave. bed thickness
Providing and fixing S.W. gully trap with C.I. grating brick ma-
sonry chamber and water tight C.I. cover with frame of
300mm x 300mm size (inside) with standard weight.(i) Square
mouth traps. (A) 100mm x 100mm size P type.
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared
for collar joints including testing of joints complete.(B) 150mm
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse
sand) finished with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse
sand :4-stone aggregate 20mm nominal size) finished smooth
complete including curing and festing (i) Inside size 900mm x
1200mm and 1.5M. deep including C.I. cover with frame size
560mm diameter total weight of cover and frame to be not
less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry using brick
having crushing strength not less than 35Kg. / Sq.cm. in Ce-
ment Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth
0.90 Metre for 150mm diameter sewer.
Supplying and fixing C.I. cover 300mm x 300mm without
202 frame for Gulley trap (Standard pattern) te weight of cover to Each
be not less 4.53 Kg.)
Constructing Brick masonry road gully chamber 500mm x
203 450mm x 600mm including 500mm x 450mm C.I. horizontal Each
grating wih frame complete.
Constructing Brick masonry road gully chamber 450mm x
204 450mm x 775mm with vertical gating complete.
Constructing brick masonry chamber for underground C.I. In-
spection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggre-
gate 20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm and 450mm
deep for single pipe line.
Constructing brick masonry chamber for underground C.I. In-
spection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggre-
gate 20mm size) foundation concrete 1:5:10 inside plaster
15mm thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete etc.
complete.(ii) Inside dimensions 500mm x 700 mm and 450mm
deep for pipe line with one or two inlets.
207 Labour Charges half round edge for Granite RMT
208 Labour Charges edge finished for Granite RMT
209 Labour Charge for removing existing block and Refixing. SMT
Providing wood work in frames of false- ceiling, partitions etc
210 sawn and put up in position. (A) Indian Teak Wood
Providing and fixing M.S. grills of required pattern to wooden
frames of windows etc. with M.S. flats at required spacings
and frame alround, square or round bars with round headed
bolts and nuts or by screws (A) Plain Grill.
Providing and fixing 35 mm thick shutters for Doors, windows
and clerestory windows including Indian teak wood frames
212 cm x 7 cm. size including anodized alluminium fixtures and SMT
fastenings including primer coat of approved quality and two
coats of oil painting etc, complete. (i) Fully Glazed.
Providing and fixing 35 mm thick shutters for Doors, windows
and clerestory windows including Indian teak wood frames
213 cm x 7 cm. size including anodized alluminium fixtures and SMT
fastenings including primer coat of approved quality and two
coats of oil painting etc, complete. (ii) Fully Panelled.
Providing and fixing 35 mm thick shutters for Doors, windows
and clerestory windows including Indian teak wood frames
cm x 7 cm. size including anodized alluminium fixtures and
fastenings including primer coat of approved quality and two
coats of oil painting etc, complete. (iii) Partly panelled and
Providing and fixing FRP frame size 125x65 mm and 35mm
thick FRP shutter with wood grain raised panneled design fin-
ish shutter having extra reinforcement on sides & edges in Gel
coat finish. The core of the shutter & frame is to be filed up
with injected polyurethene foam done in situ alongwith em-
bedded wooden pieces for stiffening & also taking hinges &
fintures. The whole FRP frame & shutter is to be water proof
weather proof, termite proof & resistance to mild acid/alkali.
Rates are to be inclusive of S.S hinges with fastener sleeve &
alluminium fixtures & fastenings.
(i) Providing and fixing glazed louvered glass windows and
216 ventilators with teak wood frame 10cm. x 7cm. size including SMT
3 coats of oil painting to wood work etc.complete.
Providing corrugated G.I. sheet of class-3 roofing fixed with
glavanished iron J or L Hooks, Bolts and nuts 8mm diameter
217 with bitumen and G.I. limpet washer or G.I. limpet washer. SMT
filled with white lead complete excluding the cost of purlins,
Rafters and Trusses.(1) 0.80 mm thick sheet.
Providing ridges or hips 600 mm overall in plain G.I. sheet
class-3 fixed with G.I.J. or L Hooks and nuts 8mm dia G.I.
Limpet and bitumen washer complete. (1) 0.80 mm thick
Providing valleys 900mm overall in plain 1.6mm thick G.I.
sheet fixed with G.I. J or L Hooks, Bolts and nuts glavanised
iron J or L Hooks Bolts and nuts 8mm dia G.I. Limpet and bi-
tumen washers complete.
Providing and Fixing 6 mm thick Lexan Polycarbonate multi
wall roofing sheet fixed with hilti screw and rubber silicon
sealer and alluminium strip of size 50 x 3 mm etc complete as
directed by Engineer in charge.
Structural steel work ( Confirming to IS 4923-1997) riveted,
bolted or welded in builtup for all type sections, in framed
work, including cutting, hoisting, fixing in position and apply-
ing a priming coat of approved steel primer all complete as
per the structural designs and directions of Engineer in
charge.Column ( 122 x 61 x 3.6mm )
222 Concealed cock 15 mm Heavy duty with cap Each
providing and fixing Waste Pipe for Wash basin/urinal C.P.
40mm dia 1.5mtr length
Providing and fixing extruded aluminum window, Door, etc
having extruded aluminum Colour Powder Coated section
frame main outer size 127mm x 38.10mm x 1.35mm (of Jindal
Section no:2443,@ Wt.1.384 Kg/mt),horizontal Two / Three
track member size 122.20mm x 31.75mm x 1.10mm (of Jindal
Section no:8787,@ Wt. 1.205 Kg/mt),vertical member of size
122.20mm x 31.75mm x 1.50mm (of Jindal Section
no:8935,@ Wt. 1.398 Kg/mt) with sliding shutters of horizon-
tal member size 40mm x 18mm x 1.29mm (of Jindal Section
no:8949 @ wt.of 0.456Kg/mt),vertical member of size 40mm x
18mm x 1.29mm (of Jindal Section no:8947 @ wt.of
0.456Kg/mt/Section 8948,@ Wt. 0.457 Kg/mt) with 5 mm
thick transparent bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and transparent silicon
sealant glass fixing to frame as per details etc complete for
Providing fitting & fixing partly glazed anodised aluminium
partition using extruded section fabricated by standard
manufactures with framing 7.15cm x4.45cm rectangular sec-
tion & door shutter /panel of partition made from 6.0 cm x
3.75cm aluminium bottom section top & vertical section
6.00x3.75cm size using 5.5mm thick "Triveni"or HB4 plain
glass with glazing deep rubber gasket & hard laminated sheet
3 mm thick panel with door arrangement & locking arrange-
ment(Godrej type) with all fixtures & fastenings of ano-
dised section with aluminium frame mounted door closer with
all labours & materials etc. Complete as per drawing and as
directed by E.I.C.
Providing and fixing eco-friendly light weight calcium silicate
false ceiling tiles having Tegular edge & 15 mm Thick Densi-
fied edges on the Tile Periphery for Extra Strength The Light
weight calcium silicate ceiling tiles shall have , light reflection
85% non-combustible as per B.S.476 part IV, 100% humidity
resistance and also having thermal conductivity 0.043° w/m
KC.for the best thermal Insulation . The Light weight calcium
Silicate tile shall be of approved texture Fine fissured/ Spin-
tone/Cosmos having NRC value of 0.5 & Globe having NRC
value of 0.75 NRC or equivalent of size 595 X 595 mm to be
laid on true horizontal level suspended inter locking metal grid
226 of hot dipped galvanized steel sections (galvanizing @120 SMT
grams per sqm including both side) consisting of main ‘T’ run-
ner suitably spaced at joints to get required length and size of
24X38mm made from 0.30 mm thick (minimum) sheet,
1200mm centre to centre, and cross ‘T’ of size 24X28mm
made out of 0.33mm (Minimum) sheet spaced 1200mm along
spaced between main ‘T’ at 600mm centre to centre to form
agrid of 1200X600mm and secondary cross ’T’ of length
600mm and size 24x28mm made of 0.30 mm thick (Minimum)
sheet to be interlocked at middle of the 1200X600mm panel to
form grid of size 600X600mm resting on periphery
walls/partitions
Removing dry or oil bound distemper by a washing and scrap-
227 ing and sand papering the wall surface smooth including nec-
essary repairs to scratches complete.
Extra over item 134 for removing dry oil bound distemper on
ceilings and sloping roofs.
Aldrop 20mm. dia Size with necessary fitting Iron Oxidised
Aldrop 20mm. dia Size with necessary fitting Iron Oxidised
Aldrop 20mm. dia Size with necessary fitting Iron Oxidised
232 S.S. Stopper 20 Cm long of ASIS 304 Each
S.S. Pipe Handle for door 30 Cm size o ASIS
234 Labour charges - Carpentar 1st Class Each
235 Labour charges - Mason 1st Class days
236 Unskilled Labour days
Towel Rail Pair of C.P. Brass Brackets 60mm x
238 Towel Rail Pair of C.P. Brass Brackets 60mm x 20mm Each
Providing and filling rubbles including hand packing and filling
239 interstices with quarry spalls behind abutments and between CMT
returns as directed.
240 Supply of black/white Glass 12 mm thick with border moulding SMT
241 Supply of black/white Glass 10 mm thick with border moulding SMT
242 Supply of black/white Glass 8 mm thick with border moulding SMT
Providing and fixing rolling shutters of approved make made
of 80 mm wide M.S. laths inter-locked together through their
entire length and jointed together at the ends by end locks
mounted on specially designed pipe shaft with bracket plates,
guide channels and arragements for inside and outside locking
with push-pull operation including the cost of hood cover and
spring etc. complete. (B) Shutters having width 3.5 M. and
Steel work, riveted in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat
of red lead paint. (A) In beams and joists, channels angles
Tees, flats, with connecting plates or angle cleats as in main
and cross beams. Hip and jack rafters, purlins connected to
common rafters and the like
Cutting, pulling out and removing thick jungle grass,shrubs,
bushes and unwanted vegetations/pants from their roots and
up-rooting from the area of Khadi i.e. natura drain channel or
gutter filled-up with sewage water, earth,coal and storm water
including removing of silted stuff of mud, sewage, earth etc.
by digging or lifting out all materials by engaging hydraulic
excavator of one Cu.M.bucket and dispose off all stuff and cut
245 vegetations as directed by the Engr.-in-charge. Also making Hour
sewage & storm water flow in smooth flowing condition by
preparing @ 3.0 mtr wide channel for the smooth water flow
as per the instruction of the E.I.C. The rate includes all require
dmachineries, tools & tackles, materials, labours, loading &
unloading, transportation, equipments etc. complete at the
risk and cost of the contractor. Payment will be made for the
actual work done hours at site.
Tractor Trip (As per requirement)
Providing composite water proofing treatment to floor and
walls of water tank, w.c.bath area, through approved agen-
cies preparing floor and wall for water proofing work/ by chas-
ing/cutting as per the companies requirement. First by provid-
ing and applying cementitious crystalline based waterproofing
for concrete rafts, walls, water tanks, slabs, concrete floors
etc. with Krystol T2 or equivalent system. Cementitious
based dry Krystol T2 Crystalline powder capable of creating
Crystals to seal the pores, intercises and micro cracks in the
concrete. The application to be done from positive side on a
wet open pore concrete surface with brush @ to 1 kg/ sqm as
per mfg.'s specification. After testing with ponding after
days, a layer of plaster with waterproofing compound/ admix-
ture about 25 mm thick in the floor / depression and about
mm on the sidewalls / depression upto the floor level shall be
provided over the surface treated with crystalline powder. The
waterproof plaster about 18 mm thick to be continued on the
walls above the floor level for a height of 600 mm with surface
suitable to receive further finishing treatment all complete as
per companies specifications and instructions and as directed
for all heights and floors. The round vata shall be included in
this in sq.mt. and shall be taken upto top of round on wall
Filling of crack after making necessary groove and applying
248 the water sealent coat and etc. complete as per the instruc- Rmt
Applying weather proof rain coat of preferably Dr.Fixit brand
249 on required area after cleaning the surface and etc. complete Sqmt
as per the directives of EIC.
Chemical water proofing on terrace (For old buildings
where china mosaic is not effective)
Cleaning the application surface with wire brush or grinder as
required. Remove all loose particles and sprinkle water to
make the surface in SSD condition
Opening of cracks in v groove and filling up of the same with
Dr. Fixit Crack-X paste or PMM as per requirement.
Application of Dr. Fixit Newcoat coating as per product’s
specification/method of statement along with all necessary
surface preparations. (Providing & applying 3 coats of Dr. Fixit
Newcoat an acrylic elastomeric waterproof coating for terrace
& sloping roofs at
coverage of 7-8 Sqft / liter/3-coat to achieve DFT of 1000 mi-
crons, on primed surface with Dr. Fixit Primeseal primer dilut-
ed in 2:1 proportion with coverage of 80-100 Sq.ft / litre/
coat. 45 gsm fibre mash to be laid after first coat of New
Coat) as per market refrence attched herewith.
Removing the existing deteriorated china mosaic water proof-
ing tiles and carrying out fresh china mosaic after performimg
he necessary steps and etc. complete as per the instructions
Angle Cock with PVC pipe connection upto WHB
Hose pipe for pillar cock
Wall mounted SS sink tap
Providing and fixing jet spray/hand faucet of W.C. with all
255 necessary fittings as per instruction of EIC Each
Providing and fixing Toilet paper holder (A) C.P brass
Providing and fixing PTMT soap dish holder having length of
257 138mm, breadth 102mm, height of 75mm with concealed fit- Each
ting arrangements.
Providing and fixing alluminium section door lock with all
necessary fittings as per instruction of EIC
Providing and fixing glass door lock with all necessary fit-
tings as per instruction of EIC
Providing and fixing flush tank of W.C. with all necessary
fittings as per instruction of EIC
Providing and fixing in position collapsible steel shutters with
vertical channels 20 x 10 x 2 mm braced with flat iron diago-
nals 20 x 5 mm size with top and bottom rails
of T_rin 40x 40 x 6 mm with 38mm dia, steel pulleys complete
with bolts, nuts, locking arrangements, stoppers handles in-
cluding applying a priming coat of red lead paint.
Providing and fixing Stainless steel pipe railing using round
S.S. pipe of various diameter of approved quality with S.S.
No. 304 consisting 8 % nickel having pipe of 16 gauge includ-
ing Horizontal and vertical pipe as per detailed drawing. Verti-
cal pipe ( posts ) firmly embedded in flooring with concrete to
262 give a proper and tough support, pipe should be inter con- RMT
nected by stainless steel gas welding. All joints having a
smooth finish including required fixtures and fastening of ap-
proved quality. The fabrication should be done as per detailed
drawing and as per instructions given by E.I.C. including all
material and labour required etc. complete.
Removing and Refixing the window after necessary re-
pair/maintenance and if required provide new bearing/busing
or any other part if required including all labour and material
etc. as per instructions of EIC
Removing and Refixing the window with MS Grill after neces-
sary repair/maintenance and if required provide new bear-
ing/busing or any other part if required including all labour
and material etc. as per instructions of EIC
DOOR CLOSER (GODREJ/DORMA / HAFELE) ITS 96 - Providing
and fixing Door Closer Dorma ITS 96 EN -2-4 Cam action door
closure /approved equivalent suitable for max width of
mm or approved equivalent make. The door closer shall be
with integrated in the frame or door leaf, with rapidly decreas-
265 ing opening resistance. Closing sped and latching action ad- Each
justable; mechanically cushioned limit stay. Adaptation to dif-
ferent rebate clearances possible non-handled (i.e. suitable for
right hand & left hand door); max.opening angle 120 degree.
All complete as per detail drawing, as specified and as di-
rected by Architect / Consultant / Project - In - Charge.
DOOR CLOSER (GODREJ/DORMA / HAFELE) TS 71 -
266 Providing and fixing Door Closures Each
Providing and fixing alluminium section door lock with all nec-
267 essary fittings as per instruction of EIC Each
Providing and fixing glass door lock with all necessary fittings
268 as per instruction of EIC Each
Providing and fixing wooden/glass/alluminium door closer with
269 all necessary fittings as per instruction of EIC Each
Double layer Roller Blinds Providing and installing Zebra dou-
270 ble laye rroller blind Polyester corded including all fixtures.
Filling of crack after making necessary groove and applying
271 the water sealent coat and etc. complete as per the instruc- RMT
Applying weather proof rain coat of preferably Dr.Fixit brand
272 on required area after cleaning the surface and etc. complete SMT
as per the directives of EIC.
Providing, laying, spreading and compacting graded stone ag-
gregate to wet mix macadam specification including premixing
the Material with water at OMC in mechanical mix plant car-
274 riage of mixed Material by tipper to site, laying in uniform lay- CMT
ers with paver in sub- base / base course on well prepared
surface and compacting with vibratory roller to achieve the
desired density.
Providing and fixing RBT reinforced barbed wire weighting
275 9.38 Kg. per 100 Metre, strained and fixed to posts with RMT
G.I,staples including fixing the postsin etc complete.
Providing and fixing concertina coil fencing with punched tape
concertina coil 600 mm dia 10 metre openable length ( total
length 90 m), having 50 nos rounds per 6 metre length, upto
3 m height of wall with existing angle iron ‘Y’ shaped placed
2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced
barbed wire, stud tied with
G.I. staples and G.I. clips to retain horizontal, including neces-
sary bolts or G.I. barbed wire tied to angle iron, all complete
as per direction of Engineer-in-charge, with reinforced barbed
tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile
strength of 165 kg/ sq.mm
with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost
of M.S. angle, C.C. blocks shall be paid separately)
Wooden Partition ( Full and Half Height )The scope includes
supply and erection /installation of the item on site. The parti-
tion frame work comprises of 25 X 50 mm MDF Section with
vertical and horizontal sections with necessary gaps for cable
management at regular intervals, The penal are of 8 mm MDF
stuck on both side of grid work with outer side with .8 mm
high pressure laminate, The partition are fixed with tong and
grove arrangement , The framework can be with panels made
of fabric, inboard panel, laminated panels or glass panels, The
fabric panels are made of 8mm. plain partical board/ MDF lad-
ed with desired fabric / laminate, The inboard panels are
made of 12mm. soft board with, clubbed with desired fabric,
The Laminate panels are made of 8mm. plain partical
board/MDF pressed with high pressure laminate of 1 mm,
Wherever necessary the cutouts are provided for mounting
the switches,for details and assembly work refer drawings,
laminate to be approved by client / consultants. The rate in-
cludes cost of all labour, material and with necessary tools,
tackles, adhesive, screws etc. An external beading / visible
teak wood / veneer surfaces shall have matt melamine polish
and internal surfaces shall be finished with French polish.for
satisfactory completion of this item. The rate also includes for
all necessary items required to complete the job as per design
/drawing and client / consultant's instructions.
Supplying, fabricating and installing hermatically sealed 6-12-6
mm double glazed vision panel units as per specifications,
spacers, dessicants, primary and secondary seals etc. includ-
ing structural silicon sealant etc. all complete as per approved
shop drawings and specifications.
( Outer glass - As per approved sample )
a. The glass shall be of approved make having main frame
work of verticals and horizontals out of specially designed ex-
278 truded sections to withstand basic wind pressure of 150 Sqmt
kg/sqm confirming to IS 875 Part III/equivalent BS 6399-Part
II and fabricated, fixed at all levels, elevation & heights.
b. 'The insulated glass (Double Glazed panel) shall have Alu-
minium spacers and primary sealant as Poly-isobutylene (PIB)
and a secondary seal with silicon sealant of Dowcorning 983/
DLLR 3362 / General Electric IGS 3204 or Tremco Proglaze
Two component silicon selant or approved equivalent make.
Same as item above but for providing openable top hung pan-
els with approved stainless friction stays, locking sets, handles
including providing and fixing 70mm sided triangular sign in
film on outer glass syrface etc all complete as per approved
shop drawings and specifications.
Item No. 216, 217 & 218 shall be carried in accordance with
the following two clauses.
1. Entire system shall be designed to accommodate thermal
movement of the aluminium components and glass resulting
from the exterior skin temperature from 15 to 45 deg. celsius
and to accommodate horizontal building movement of maxi-
mum 10mm per bay and vertical movement of maximum
mm between floors and conforming that no aluminium mem-
bers shall be visible from outside etc. complete and as di-
2. The system shall be designed by an expert having experi-
ence of designing structural glazing system and having neces-
sary setup and infrastructure for testing the same as per spec-
Partition glass in Living Room/Bed Rooms/Bathrooms-
Providing & fixing 12mm thk toughened extra clear float glass
partition including doors or opening ( including of floor spring
or doorcloser) using dorma make spider/ patch fittings as per
their specification and requirement upto a height of 13'. Item
to include patch fittings (dorma or equivalent make) as shown
280 in the drawing at all necessary joints and depending on the Sqmt
weight of the glass. Item to include sealant between two glass
panes. Shop drawings to be approved by the Architects before
installation of the glass partitions with all hardware type and
its sizes and placement to ensure the partition is sturdy &
Providing and applying frost film on internal glass partition
panels neatly complete as per the company specification.
FLOOR SPRING (GODREJ/DORMA / HAFELE) BTS 75 - Provid-
ing and fixing floor springs Dorma make BTS 75 V with zero
degree open function or approved equivalent. The floor spring
should be with adjustable closing force and closing speed.
Closing action effective form approx 175 degree, with full hy-
281 draulic sequential control and back check. Including cement Nos.
box, replaceable standard spindle and SS cover plate. Non
handed; also suitable for double action doors cover plate ma-
terial and finish: stainless steel of approved make and specifi-
cation etc. All complete as per detail drawing, as specified and
as directed by Architect / Consultant / Project - In - Charge.
Providing and fixing 18mm thick horizontal shelve made of
commercial plywood in cupboard with both side 1mm thick
white lamination/sunmica (As per requirement) and necessary
fittingand fixtures shall be provided of SS, as per selection of
EIC however work should be executed as per instruction of
The scope includes supply and erection /installation of the
item on site. Tables are made of 25 mm. thick partial board.
The top surface is finished with high pressure laminate of
mm. thickness. To avoid warpage boards are provided with
balancing laminate of 0.6 mm. thickness. The edges of top
surface are finished with 1 mm. PVC / Laminate edge banding.
The quality of edge banding material is ABS with primer with
single colour. The band is stuck to the surface at 200 centi-
grade under high pressure for better adhesion. Mobile Drawer
Unit : The box body except the back of the Mobile Drawer Unit
is made of 18mm. thick particle board. The surface is finished
with 1 mm. thick high pressure laminate. The back is made of
8mm. prelaminated particle board which slides inside the box
body. All the boards have balancing laminate of 1 mm. thick-
ness., The edges of box body is finished with 1 mm PVC /
Laminate edge banding. The quality of edge banding material
is PVC with primer with single colour. The band is stuck to the
surface at 200 degree centigrade under high pressure for bet-
ter adhesion., The box body is assembled with the help of
Nos. of wooden dowels with surressions of 40 X 8 mm. and
with the help of mini-fix. No screws are visible outside on the
box body., The inside drawer body is made of 12mm. prelam-
inated partial board fitted on bottom mounted self-closing
soft roller slides of 400mm. The bottom of drawers are made
of 8mm. prelaminated partical board which slides inside the
body., The Drawer Units are fitted with unpickable front lock-
ing mechanism, made of rim locks. The design of the locking
mechanism is such that only one drawer at time can be
opened for safety. The keys are supplied in duplicate., The
MDUs are fitted with ‘ C ‘ handles of 8 X 75 mm., The MDUs
are fitted with 4 Nos. of twin castors out of which the front
Nos. have locking mechanism. KEY BOARD TRAY : Keyboard
tray is made of 18 mm thickness Prelam Partical board
and Durable telescopic channel both sides. The Colour and
Finish Of Tray will be Matching To Table Finish., Keyboard is
available with or without mousepad. Where required.Sizes
are :710 X 250 X 85 (With mousepad), 530 x 250 x 85 (
With Out Mouse pad ) CPU TROLLY : CPU stand is made
out of C.R.C.A. 12mm thick Gauge with pretreatment
and 45-micron powder coat in approved colour. CPU
stands are provided with four supreme quality of castor
in which two casters are with brake and other two
casters are without brake. Inner wall of CPU stand and
bottom plate is covered up with polyurethene 6 mm
thick sheet to protect the CPU box from damage.,All
steel components are painting. The process consists of
degreasting , derusting, phosphating & drying to attain
proper phosphate coat & crystalling surface. The phos-
phate products are powder coated., Modesty Panel :
mm thk. Prelam partical boad ,Partition : The partition frame
work comprises of 25 X 50 mm MDF Section with vertical and
horizontal sections with necessary gaps for cable management
at regular intervals, The penal are of 8 mm MDF stuck on both
side of grid work with outer side with .8 mm high pressure
laminate, The partition are fixed with tong and grove ar-
rangement , The framework can be with panels made of fab-
ric, inboard panel, laminated panels or glass panels, The fabric
panels are made of 8mm. plain partical board/ MDF laded with
desired fabric / laminate, The inboard panels are made of
12mm. soft board with, clubbed with desired fabric,
The Laminate panels are made of 8mm. plain partical
board/MDF pressed with high pressure laminate of 1 mm,
Wherever necessary the cutouts are provided for mounting
the switches, The rates of this item includes cost of 1200 mm
ht. partitions ( shared / non-shared basis ) as per layout. No
additional cost shall be payable for any changes in the layout,
softboard , laminate, glass panels 2 raceways in all 1200 mm
high partition, for details and assembly work refer drawings,
laminate to be approved by client / consultants. The rate in-
cludes cost of all labour, material and with necessary tools,
tackles, adhesive, screws etc. An external beading / visible
teak wood / veneer surfaces shall have matt melamine polish
and internal surfaces shall be finished with French polish.for
satisfactory completion of this item. The rate also includes for
all necessary items required to complete the job as per design
/drawing and client / consultant's instructions
Table - 1500 x 750 x 760 mm ( T2 )The scope includes
supply and erection /installation of the item on site. Tables are
made of 25 mm. thick partial board. The top surface is fin-
ished with high pressure laminate of 1 mm. thickness. To
avoid warpage boards are provided with balancing laminate of
0.6 mm. thickness., The edges of top surface are finished with
1 mm. edge banding. The quality of edge banding material is
ABS with primer with single colour. The band is stuck to the
surface at 200 centigrade under high pressure for better ad-
hesion., Mobile Drawer Unit : The box body except the back of
the Mobile Drawer Unit is made of 18mm. thick particle board.
The surface is finished with 1 mm. thick high pressure lami-
nate. The back is made of 8mm. prelaminated particle board
which slides inside the box body. All the boards have balanc-
ing laminate of 1 mm. thickness., The edges of box body is
finished with 1 mm. edge banding. The quality of edge band-
284 ing material is PVC with primer with single colour. The band is Nos.
stuck to the surface at 200 degree centigrade under high
pressure for better adhesion., The box body is assembled with
the help of 8 Nos. of wooden dowels with surressions of 40 X
8 mm. and with the help of mini-fix. No screws are visible out-
side on the box body., The inside drawer body is made of
12mm. prelaminated partical board fitted on bottom mounted
self-closing , soft roller slides of 400mm. The bottom of draw-
ers are made of 8mm. prelaminated partical board which
slides inside the body., The Drawer Units are fitted with un-
pickable front locking mechanism, made of rim locks. The de-
sign of the locking mechanism is such that only one drawer at
time can be opened for safety. The keys are supplied in dupli-
cate., The MDUs are fitted with ‘ C ‘ handles of 8 X 64 mm.,
The MDUs are fitted with 4 Nos. of twin castors out of which
the front 2 Nos. have locking mechanism. KEY BOARD TRAY
: Keyboard tray is made of 18 mm thickness Prelam Par-
tical board and Durable telescopic channel both sides. The
Colour and Finish Of Tray will be Matching To Table Finish.,
Keyboard is available with or without mousepad. Where
required.Sizes are :710 X 250 X 85 (With mousepad),
x 250 x 85 ( With Out Mouse pad ) CPU TROLLY : CPU stand
is made out of C.R.C.A. 12mm thick Gauge with pre-
treatment and 45-micron powder coat in any colour. CPU
stands are provided with four supreme quality of castor
in which two casters are with brake and other two
casters are without brake. Inner wall of CPU stand and
bottom plate is covered up with polyurethene 6 mm
thick sheet to protect the CPU box from damage.,All
steel components are painting. The process consists of
degreasting , derusting, phosphating & drying to attain
proper phosphate coat & crystalling surface. The phos-
phate products are powder coated., Modesty Panel :
mm thk. Prelam partical boad ,for details and assembly work
refer drawings, laminate to be approved by client / consult-
ants. The rate includes cost of all labour, material and with
necessary tools, tackles, adhesive, screws etc. An external
beading / visible teak wood / veneer surfaces shall have matt
melamine polish and internal surfaces shall be finished with
French polish.for satisfactory completion of this item. The rate
also includes for all necessary items required to complete the
job as per design /drawing and client / consultant's instruc-
Credenza - 900 x 450 x 760 mm ( C2 )
The scope includes supply and erection /installation of the
item on site., The box body except the back of the credenza is
made of 18mm. thick partical board. The top is finished with
1 mm. thick high pressure laminate. The back is made of
8mm. prelaminated partical board which slides inside the box
body. All the boards have balancing laminate of 1 mm. thick-
ness. ,The edges of box body is finished with 1 mm. edge
banding. The quallity of edge banding material ABS or PVC
primer with single colour. The band is stuck to the surface at
200 degree centigrade under high pressure for better adhe-
sion., The box body is assembled with the help of 8 Nos. of
wooden dowels with surressions of 40 X 8 mm. and with the
the help of mini-fix . No screws are visible outside on the box
body., The credenza is provided with adjustable shelf. The
pitch of adjustment is 32mm. The shelfs are fitted with stiff-
eners made of CRCA steel of 16 G duly powder coated ., The
shutters are fitted with sliding channels made of alluminium
with roller bearing on top and bottom for sliding., The creden-
zas are fitted with unpickable push lock. The keys are supplied
in duplicate., The shutters are fitted with ‘ C ‘ handles of 8 X
75 mm., The credenzas are fitted with 4 Nos. of level adjust-
ers. The range of level adjustment is 15 mm.,for details and
assembly work refer drawings, laminate to be approved by
client / consultants. The rate includes cost of all labour, mate-
rial and with necessary tools, tackles, adhesive, screws etc.
An external beading / visible teak wood / veneer surfaces shall
have matt melamine polish and internal surfaces shall be fin-
ished with French polish.for satisfactory completion of this
item. The rate also includes for all necessary items required to
complete the job as per design /drawing and client / consult-
ant's instructions.
Storage - 1500 x 450 x 760 mm ( S2 )The scope includes
supply and erection /installation of the item on site., 4 shut-
ters , The box body except the back of the Storage is made of
18mm. thick partical board. The surface is finished with 1 mm.
thick high pressure laminate. The back is made of 8mm. pre-
laminated particle board which slides inside the box body. All
the boards have balancing laminate of 0.6mm. thickness.,
The edges of box body is finished with 1 mm. edge band-
ing.The quality of edge banding materials is ABS or PVC with
single colour. The band is stuck to the surface at 160 degree
centigrade under high pressure for better adhesion., The box
body is assembled with the help of 8 Nos. of wooden dowels
with surressions of 40 X 8 mm. and with the help of mini-fix.
No screws are visible outside on the box body., The storage is
supported with adjustable shelves. The pitch of adjustment is
32mm. The shelves are fitted with stiffeners ( on request )
made of CRCA steel of 16 G duly power coated. The thickness
of powder coating is 50 microns., Alternatively the storages
are provided with concealed clip on hinges with the opening of
98 degree., The shutters are fitted with ‘ C ‘ handles of 8 X
160 mm., The storage is fitted with multipurpose lock. The
keys are supplied in duplicate., The storages are provided with
4 Nos. of level adjusters. The range of level adjustment is
mm. ,for details and assembly work refer drawings, laminate
to be approved by client / consultants. The rate includes cost
of all labour, material and with necessary tools, tackles, adhe-
sive, screws etc. An external beading / visible teak wood /
veneer surfaces shall have matt melamine polish and internal
surfaces shall be finished with French polish.for satisfactory
completion of this item. The rate also includes for all neces-
sary items required to complete the job as per design
/drawing and client / consultant's instructions.
Providing and fixing Wooden file storage wall mounted/floor
mounted with openable shutters incl. all necessary joints,
mm th. SF finish laminate , teakwood lipping, SS concealed
handle, sliding lock & necessary hardware materials etc .All
inside and outside ply shall be made of commercial plywood
18mm thick and covered with 1mm thick SF laminate as per
selection of EIC however work should be executed as per in-
struction of EIC.
Details of Wooden file storage: Each storage will be treated as
single unit with 6 sides i.e. front(single/double shutters), Back,
left, right, top and bottom. Each shutter must be fixed on one
of two verticle sides which should not be more than 500mm
width. The depth/bredth of cupboard shall not be more than
500mm for each storage Height of each cupboard shall not be
more than 1200mm, each cupboard shall have to be provide
with 02 handle of SS, 04 magnets, 02 chain, 01 door stopper
of SS and 01 lock. Measurement will be taken only for front
Providing and fixing 18mm thick horizontal shelve made of
commercial plywood in cupboard with both side 1mm thick
white lamination/sunmica (As per requirement) and necessary
fitting and fixtures shall be provided of SS, as per selection of
EIC however work should be executed as per instruction of
Partition glass in Living Room/Bed Rooms/Bathrooms-
Providing & fixing 12mm thk toughened extra clear float glass
partition ncluding doors or opening ( including of floor spring
or door closer)
Providing and fixing horizontal/vertical plywood partition with
all outer and inner plywood surface covered by 1mm thick SF
290 Laminate finish using 18 mm thick waterproof coating,anti SFT
termite, anti fading plywood selected by Engineer in charge
with necessary hardware materials etc.
Providing and fixing vertical soft board partition with frontside
covered by fabric and all other 3 outer and inner sides covered
291 by 1mm thick SF Laminate finish using 12 mm thick soft board SFT
necessary hardware materials etc
Sealing of epoxy between the tiles 4mm thick and filling upto
the top of the tiles including the cleaning of the grooves thor-
oughly before applying the epoxy with all the material and
Providing and fixing double polished MARBLE SHELVES 25mm
thick FOR cupboards, stone racks etc, including making gissi in
brick wall and filling gap with cement slurry and cement mor-
tar etc complete in true line and level as directed by EIC.
Providing & fixing 18 mm thick first quality required shade Pol-
ished Granite stone approved by Client/Architect for Doors -
windows Frame, Lintel, jambs & sill in cement mortar (1:3)
cutting, fixing in cement paste with hairline joint, filling the
joints with white cement / pigments / joint filler,rounding of
edges, edge polishing & finishing as directed by the Engineer.(
fixing the granite in one piece )
P/F 18 mm avg. thick double polished(both side) jet black
granite slab for urinal partition incl. making groove in wall and
fixing properly in line & level incl. all cost of materials & la-
bours etc. complete at all levels
Providing and fixing 12mm Toughened glass Doors in Double
leaf of sizes mentioned in the Architect's drawing / Doors
schedule or as directed by the Engineer Incharge / Architect.
12mm toughened glass doors shall be fixed using S.S. patch
fitting of 316 grade of Dorma / Geze or equivalent make with
prior approval of the Architect / Engineer Incharge. The 12mm
thick temperd glass must meet the safety specification speci-
fied in ANSI Z97.1 CPSC 16 CFR 1201, ASTM C 1036, ASTM C
1048 & shall be free of any manufacturing defect All the edges
glass shall be mirror polished The installation of toughned
glass door shall comply with the recommendations of the
patch fittings manufacturers and shall comply to there stand-
drawings. The door shall be provided with tubular, lockable,
pull handles with tumb turns 84" length and made from S.S.
316 S.S. grade of Geze/ Dorma or equivalent make.The door
provided with floor concealed closer adequately capable of
controlling the door weight. The closers will have selectable
delayed action standard without backcheck. The closer shall
used with sealing compound to prevent water or cleaning sol-
vent from entering the case.The plate finish shall be S.S.
Applying two coats of Birla (white cement based) or Asian
(acrylic lapyputty) or equivalent & two coats of primer of ap-
proved brand and manufacture on new wall surface to give an
even shade including thoroughly brushing the surface free
from mortar dropping and other foreign matter and sand pa-
pered smooth with Wall painting (two coats) of plastic emul-
sion paint of approved brand and manufacture on ceiling to
give an even shade (work for all the floors)
TEXTURE PAINT ON WALL - Providing and applying Texture
Paint including preparing surface, using roller to get approved
texturised surface.(Outside/Inside) Job to include making re-
quired surface preparation, to receive Texture paint finish etc.
All complete as per detail drawing, as specified and as di-
rected by Architect / Consultant / Project - In - Charge
Providing and laying 1000 mm x 1000 mm Anti skid / Glossy
tile as per instruction of EIC
Providing and laying 1200 mm x 600 mm Anti skid / Glossy
300 Vitrified(GVT) full body 10 mm thick tiles as per instruction of SMT
Providing and laying 1200 mm x 800 mm Anti skid / Glossy
301 Vitrified(GVT) full body 10 mm thick tiles as per instruction of SMT
Providing and laying granite slab 18mm thick in skirt-
302 ing,dedo,risers of steps & landing laid on bed of 10 mm SMT
thick(Average) base of C.M. 1:4
misc. work/Unforeseen work if required to be carried out
during execution of the work which are essential and required
at stage of working such as elevation work, flooring work,
303 electrical work, Furniture work, landscaping work, plumbing
requirement requirement
work, false ceiling work, colour work and misc. Civil work as
per instruction of engineer in charge.(payment will be made as
per item & quotation of work).
Total Amount (Excl. GST) in Rs.
Total Amount (Excl. GST) in Rs.
"All royalties, toll tax, local tax, development charges, and any other taxes etc., in respect of
this contract and also any statutory variation in future towards above mentioned taxes & any
other taxes if levied in future by statutory authority applicable to the this contract shall be pay-
able by the con-tractor and DGVCL will not entertain any claim whatsoever in this respect.
The Contractor has to pay 1% Labour Welfare Cess of Bill amount to the concern Government
The contractor shall produce the receipt of payment of 1% welfare cess from the respective
govt. department before submission of final bill, otherwise final bill for the works will not be fi-
The proof of payment made by the contractor to the appropriate department shall be submitted
to DGVCL, failing which appropriate amount shall be withheld on getting information/instruction
from the concerned department.
I /We agree to carry out the above work at
Less (-) _______________% below Rs.
Total cost of work. Rs._____________________
Signature of Tendered Addl. Chief Engineer (P)
Seal of company DGVCL, Surat.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
AMC Tender Notice 310.pdf
AMC Technical Bid -310.pdf
AMC Price Bid Sch-310.pdf
Download all tender documents and submit your bid