Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹2.2 Cr Quoted ₹2.5 Cr | L1 | Accepted-AOC Work Awarded |
Tender Value
₹2.3 Cr
EMD Value
₹1 L
Closing Date
23 Jun 2023, 3:15 pmClosed
Chief Executive Officer
Felicity Square 4th Floor Statue Thiruvananthapuram Kerala
Development of Smart Roads and Underground Ducting Including Utility Shifting of Water Supply and Power lines in ABD area Under Smart City Mission Corporation Roads in Thiruvananthapuram Pazhayasalai Road Road ID 44 Electrical Works
2023_SCTLT_559043_2
SCTL/PRJ/210/2019/MPMM/RFP39
Open Tender
Electrical Works
Item Rate
180 days
Thiruvananthapuram
Refer Tender documents
2 documents required · 2 mandatory
₹9,757
₹1 L
30 Jan 2024
16 Jun 2023
24 Jun 2023
16 Jun 2023
23 Jun 2023
16 Jun 2023
Amount
PART A - UTILITY SHIFTING OF ELECTRICAL POWER SUPPLY LINES-MATERIAL
Supply of Metallic feeder pillar box with 300 amp LB SW on both ends 24 nos of O/G terminals (1ph)with SFU for giving service connections (16amp to 62amp as per requirement).provision for cable entry on both sides, cable connecting facilities, phase indicators, volt meter and ammeter, danger labeling etc< Make: Subjected to approval from KSEB
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 2x4 sq.mm
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5x6 sq.mm
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5 x 50 sqmm
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5 x 185 sq.mm
Supply of one number armoured aluminium XLPE power cable of 1.1KV grade of the following sizes 3.5 x 150 sq.mm
Supply of one number PVC insulated single-core copper conductor cable of the following size 2.5 sq.mm
Supply of one number PVC insulated single-core copper conductor cable of the following size 4 sq.mm
Supply of one number PVC insulated single-core copper conductor cable of the following size 6 sq.mm
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 32mm dia
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 40mm dia
Supplyof following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 60mm dia
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 90mm dia
Supply of following size HDPE pipe ISI marked along with accessories like socket, bend, couplers etc. 110mm dia
Provision for feeder pillar earthing (earth pipes, gi wires/plates, earthing Chemicals)
Supply of 1Ph dust & vermin proof and weatherproof FRP meter box with 16 Amps cut out fuse and neutral link
Supply of 3Ph dust & vermin proof and weather proof FRP meter box with 32 Amps cut out fuse and neutral link
Supply of 3Ph CT dust & vermin proof and weatherproof FRP meter box with 32 Amps cut out fuse and neutral link
Supply of 1.5mtr earth pipe for meter box earthing
Supply of 10SWG Copper earth wire
Supply of LT heat shrink straight jointing kit suitable for cables of size 6 sq.mm to 16 sq.mm.
Supply of LT heat shrink straight jointing kit suitable for cables of size 70 sq.mm to 120 sq.mm.
Supply of LT heat shrink straight jointing kit suitable for cables of size 150sq.mm to 240 sq.mm.
PART B- UTILITY SHIFTING OF ELECTRICAL POWER SUPPLY LINES-LABOUR
Laying of one number armoured aluminium power cable of 1.1KV grade of the following sizes in the existing HDPE pipe/duct as per the direction of the engineer in charge. 3.5 x 150 / 3 x 150 sq mm.
Laying of one number armoured aluminium power cable of 1.1KV grade of the following sizes in the existing HDPE pipe/duct as per the direction of the engineer in charge. 3.5 x 185 sq mm
Excavation of cable trench in all classes of soil and backfilling of the trench after laying cable (3.5x120mm sq), (3.5x150mm sq), (3.5x185mm sq)
Additional rate for excavation of cable trench in exceptionally hard condition(like ordinary rock)(3.5x120mm sq) , (3.5x150mm sq), (3.5x185mm sq)
Digging and laying LT 3.5 x 50 sq mm cable including providing HDPE pipe for looping cables from pillar box to consumer premises etc as per the directions of engineer in charge.
Digging and Laying LT cable 3.5x6 sq mm (Three-phase service connection & Street light) including providing HDPE pipe for looping cables from pillar box to consumer premises etc as per the direction of engineer in charge.
Digging and Laying LT cable 2x4 sq mm (Single-phase service connection) including providing HDPE pipe for looping cables from pillar box to consumer premises etc as per the direction of engineer in charge
Charges for giving street light connection
Charges for the erection of feeder pillar box (24 nos outgoings) including Plinth and earthing
Shifting of single phase connection on newly erected meter box, including erection of meter box, earthing, wiring up to DB and other connections
Shifting of three-phase wp service connection on newly erected meter box, including erection of box, earthing, wiring up to DB and other connections
Surveying the cable route, Collecting consumers data, measuring cable length to consumers, Pole var details collection, Pillar box and Distribution box marking, preparing Sketch etc.
Doing straight joint on cables of sizes beyond 3.5x6 sqmm and upto and incl. 3.5x16 sq mm using the cable jointing kit
Doing straight joint on cables of sizes beyond 3.5x70 sqmm and upto and incl. 3.5x120sq mm using the cable jointing kit
Doing straight joint on cables of sizes beyond 3.5x150 sqmm and upto and incl. 3.5x240 sq mm using the cable jointing kit
PART C - UTILITY SHIFTING OF ELECTRICAL POWER SUPPLY LINES
Supply and fixing of 20mm size of medium class PVC conduit along with accessories in surface / resess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply, Installation, Testing and commissioning of LED steet light with output 120 lumen/W ,3000-6000 K with IP 66 protection, total output of 8000 lumen above LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters
Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 160 mm dia (OD-160 mm & ID-135 mm nominal
Supplying,installation,testing and commissioning of Astronomical time switch capable of following output in feeder pillars I Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply
OPERATION AND MAINTENANCE
Maintenance charges of road work and other components except land scaping per month for fourth year
Maintenance charges of road work and other components except land scaping per month for fifth year
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .