| 1 | L1₹1.2 CrAdmitted-Finance S NO 65 4 GALA 1 5 BLDG 5 RADHE KRISHNA IND PARK PIMPLAS VILLAGE MUMBAI NASIK ROAD BHIWANDI THANE THANE MAHARASHTRA 421302 | THANE | MAHARASHTRA | 421302 | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹8.3 L (6.88%)Admitted-Finance | ₹1.3 Cr+₹8.3 L (6.88%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹15.7 L (13.1%)Admitted-Finance | ₹1.4 Cr+₹15.7 L (13.1%) | L3 | Admitted-Finance |
| 4 | L4₹1.6 Cr+₹35.1 L (29.2%)Admitted-Finance | ₹1.6 Cr+₹35.1 L (29.2%) | L4 | Admitted-Finance |
| 5 | L5₹2.2 Cr+₹1.0 Cr (84.0%)Admitted-Finance D 95 SECTOR 47 NOIDA UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹2.2 Cr+₹1.0 Cr (84.0%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ALL GAS SOLUTIONS INFRA PRIVATE LIMITED L3 | ALIKA GREEN TECH L2 | GREENGLOBE FUEL SOLUTIONS PVT LTD L1 | GREEN ENERY SOLUTIONS L4 | PLS Automobile Services Pvt. Ltd. L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Services: | ||||||||
| 1.01 | Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 3000 WL capacity CNG Stationary Cascade with 40 Cylinders of 75 Ltrs each.
(Including Hydra charges) | 43 | Nos. | 86,999 ₹44,14,329.26 | 66,000 ₹33,48,840 Lowest | 1,00,000 ₹50,74,000 | 99,000 ₹50,23,260 | 1,50,000 ₹76,11,000 |
| 1.02 | Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 3000 WL capacity CNG Mobile Cascade with 40 Cylinders of 75 Ltrs each.
(Including Hydra charges) | 34 | Nos. | 86,999 ₹34,90,399.88 | 66,000 ₹26,47,920 Lowest | 1,00,000 ₹40,12,000 | 99,000 ₹39,71,880 | 1,40,000 ₹56,16,800 |
| 1.03 | Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 3000 WL capacity CNG Stationary Cascade with 24 Cylinders of 125 Ltrs each.
(Including Hydra charges) | 6 | Nos. | 90,500 ₹6,40,740 | 46,800 ₹3,31,344 Lowest | 1,00,000 ₹7,08,000 | 81,000 ₹5,73,480 | 1,80,000 ₹12,74,400 |
| 1.04 | Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 8800 WL capacity CNG mobile Cascade with 34 Cylinders of 264 Ltrs each.
(Including Hydra charges) | 2 | Nos. | 1,85,000 ₹4,36,600 | 83,300 ₹1,96,588 Lowest | 2,75,000 ₹6,49,000 | 2,89,000 ₹6,82,040 | 2,75,000 ₹6,49,000 |
| 1.05 | Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 4500 WL capacity CNG mobile Cascade with 60 Cylinders of 75 Ltrs each.
(Including Hydra charges) | 4 | Nos. | 1,03,500 ₹4,88,520 | 99,000 ₹4,67,280 Lowest | 1,40,000 ₹6,60,800 | 1,33,000 ₹6,27,760 | 2,25,000 ₹10,62,000 |
| 1.06 | Transportation, Loading & Unloading of cascade from CNG station/store to another CNG station/store (excluding de-commissioning & re-commissioning, testing etc).
(Inclusive of Hydra charges) | 10 | Trips | 21,000 ₹2,47,800 | 18,000 ₹2,12,400 Lowest | 20,000 ₹2,36,000 | 25,000 ₹2,95,000 | 75,000 ₹8,85,000 |
| 1.07 | Additional charges for deployment of Telescopic Crane (with Boom) for sites with space constraint (at the discretion of EIC), as and when required. | 10 | Nos. | 18,500 ₹2,18,300 | 17,000 ₹2,00,600 Lowest | 20,000 ₹2,36,000 | 20,000 ₹2,36,000 | 50,000 ₹5,90,000 |
| 2.00Note: 3000 WL 1 no. 4500 WL 1 no. of additioanl quantity is considered for emergency purpose incase of any incident. | ||||||||
| 3.00Supply of Materials & Spares: | ||||||||
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
26 Dec 2022, 3:00 pmClosed
Chief Manager (C and P)
Pride Purple Coronet, 2nd Floor, Baner Road, Baner, Pune-411045
Tender for refurbishment, testing, certification and replacement of defective cascade spares of various capacity CNG cascades for a period of 02 (Two) years for CNG and CGD Project of MNGL Nashik GA.
2022_MNGL_137286_1
MNGL/CP/2022-23/148
Open Tender
Miscellaneous Services
Works
730 days
Nashik GA
As per tender document
16 documents required · 16 mandatory
₹0
₹2 L
Yes
MNGL, Baner, Pune Office
10 Mar 2023
5 Dec 2022
27 Dec 2022
5 Dec 2022
26 Dec 2022
5 Dec 2022
12 Dec 2022
Amount
Services:
Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 3000 WL capacity CNG Stationary Cascade with 40 Cylinders of 75 Ltrs each. (Including Hydra charges)
Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 3000 WL capacity CNG Mobile Cascade with 40 Cylinders of 75 Ltrs each. (Including Hydra charges)
Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 3000 WL capacity CNG Stationary Cascade with 24 Cylinders of 125 Ltrs each. (Including Hydra charges)
Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 8800 WL capacity CNG mobile Cascade with 34 Cylinders of 264 Ltrs each. (Including Hydra charges)
Loading/Unloading, Transportation, re-commissioning/de-commissioning, testing etc as per scope of work for 4500 WL capacity CNG mobile Cascade with 60 Cylinders of 75 Ltrs each. (Including Hydra charges)
Transportation, Loading & Unloading of cascade from CNG station/store to another CNG station/store (excluding de-commissioning & re-commissioning, testing etc). (Inclusive of Hydra charges)
Additional charges for deployment of Telescopic Crane (with Boom) for sites with space constraint (at the discretion of EIC), as and when required.
Note: 3000 WL 1 no. 4500 WL 1 no. of additioanl quantity is considered for emergency purpose incase of any incident.
Supply of Materials & Spares:
Cylinder valve(Manual lever type-Indian) (Vanaz)
Cylinder Valve Knob (Vanaz)
3/4" SS Ferrule Set (Swagelok/Parker)
1/2"OD SS Nut and Ferrule set (Swagelok/Parker)
1/4" SS Ferrule Set (Swagelok/Parker)
3/8" Ferrule Set SS 316 (Swagelok/Parker)
3/4" Nut SS 316 (Swagelok/Parker)
1/4" Nut SS 316 (Swagelok/Parker)
3/8" nut SS 316 (Swagelok/Parker)
Bull nose fitting (Vanaz)
Pressure Gauge Adapter (Swagelok/Parker)
4" Dial Glycerin Filled Pressure Gauge (Range 0 to 420 kgf/cm2 With 1/4" NPT-M Bottom End Connection) Wika/Waree/GI
Burst Disc (Vanaz)
SS Tube 3/4" OD(Parker/Sandvik)
SS Tube 1/2" OD(Parker/Sandvik)
1/4" OD SS Tube(Parker/Sandvik)
Stainless Steel Swagelok Tube Fitting, Reducer, 1/2 in. x 3/4 in. Tube OD
Union Tee 3/4" (Swagelok/Parker)
1/4" Union SS 316 (Swagelok/Parker)
3/4" OD 4 way fitting SS316 (Swagelok/Parker)
Bleed Valve 1/4" (Swagelok/Parker)
3/4" OD NRV Check Valve (Swagelok)
3/4" OD NRV Check Valve (Parker)
Male Connector 3/4" OD-1/4" NTP(M) (Swagelok/Parker)
Male Connector (1/4" OD tube x1/4" NPT Male) (Swagelok/Parker)
Female Bulkhead Connector (1/4" OD Tube x 1/4" NPT-F) (Swagelok/Parker)
3/4" x 3/8" NPT Male Connector (Swagelok/Parker)
3/8" x 1/4" NPT Male Connector (Swagelok/Parker)
Two-way Ball Valve Knob Swagelok NY-5K AFS-BK Black Nylon Handle Kit For AFS
Two-way Ball Valve Knob Parker
Two-way Ball Valve 3/4" Parker
Two-way Ball Valve 3/4" Swagelok
1/4"OD Safety relief Valve SS316
Copper Tube- 3/8" OD
Copper Tube- 3/4" OD
Brass Nut and ferrule set 3/8" OD
Brass Nut and ferrule set 3/4" OD
Fabrication Work of Gauge / Valve Panel:
Cascade Capacity 3000 WLC Fabrication of Cascade Gauge/Valve Panel (Including Door, Frame, angle metal sheet, glass and hinges etc. ) Size of Panel 27 inch X Width 54 inch X Height 11 Inch
ALIKA GREEN TECH
ALL GAS SOLUTIONS INFRA PRIVATE LIMITED
GREEN ENERY SOLUTIONS
PLS Automobile Services Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .