Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 19 PAOTA C ROAD JODHPUR | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
27 Jun 2024, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
Repair and maint of SWTs Tubewell Borewells and misc work in tech and domestic and cleaning of water filtration plant and allied work under AGE EM GE (AF) No 02 Jodhpur and repair maint of solar water heaters and allied works at AFS Jodhpur
2024_MES_657117_1
8463/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) No 02 Jodhpur
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (AF) No 02 Jodhpur
₹1 L
Yes
2 Jul 2024
31 May 2024
29 Jun 2024
31 May 2024
27 Jun 2024
15 Jun 2024
7 Jun 2024 - 14 Jun 2024
Amount
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth water supply pipe lines etc. in soft /loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Taking up or down 25mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately.
All as per Srl item No 4 above but 50 mm dia bore.
All as per Srl item No 4 above but 80 mm dia bore.
All as per Srl item No 4 above but 100 mm dia bore.
S&F 25mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 9 above but 80 mm dia bore.
All as per Srl item No 9 above but 100 mm dia bore.
Supplying, fixing and testing in replacement of 80mm bore cast iron sluice valve with langed ends drilled ISI marked class PN - 1.6 conforming to IS 14846-2000 with stainless steel spindle with iron wheel, CI gate with brass nut, bolts, washers and rubber packing for connecting pieces etc complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 12 above but 100 mm dia bore.
S&F in replacement gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 14 above but 50 mm dia bore.
M&L for replacement of ball valve , high pressure ,with polythene float and fly nut complete for iron pipe of 25 mm bore.
M&L for Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
M&L for cleaning of SWTs upto 15000 GLN capacity by continues dewatering till the complete cleaning of SWTs by using suitable capacity non clog diesel engine pump set and removing all the accumulated sediments, foreign particles etc including scrubbing, brushing and removing all the dirt/sludge accumulated on the walls/floor etc as required all as directed by Engr In Charge.
M&L for MS framed work as in doors or gates of angle or other section with gusset plates,rails,braces, etc , complete ,drilled for fixing of steel sheeting or other covering, cover of SWTs / UG sumps and covers of valve chambers etc fabricated from structural steel incl nuts,bolts,welding, bending, drilling etc complete all as directedincl painting over a coat of red oxide all as directed by Engr In Charge.
M&L for Construction of brick masonry valve pit of internal size 90cm x 90cm x90cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed by Engineer - in - Charge Note :-(i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B-1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Two coats of white wash to internal surfaces of valve pit. (vi) Depth of wall pit shall be reckoned from the top of PCC in foundation.
Material and labour for 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped,wired and laid in position,including closing after filling all as directed by Engr In Charge.
M&L for taking out defictive submersible pump set of capacity 10 / 12.5 HP Capacity from bore well after disconnecting electrical connections, transportation to workshop for repair, dismantling the pump set for detection of repair such as rewinding of motor, replacement of iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key, thrust bearing, replacement of unserviceable nut-bolts, washer, lugs, terminal plate, reassembling, lowering in well in its original position, making proper electrical connections, commissioning & testing complete all as specified and directed by Engineer-in-charge. Note : - (i) Cost for transportaion to workshop and carry back to site after repair is inlcuded in the unit rate of item nothing extra shall be paid on this acount. (ii) Rewinding of submersible motor, Iron stainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key and thrust bearing if required for replacement shall be paid separetly against respective items of Schedule as "Supply only". (iii) Cost of new nuts, bolts, washers, lugs and terminal plate required to be replaced is included in the unit rate of this item nothing extra shall be paid on this account.
M&L for rewiding of submersible pump set of capacity 10 / 12.5 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge
Supply only Iron stainer suitable for submersible pump of capacity 10/ 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for submersible pump of capacity 10 /12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Thrust bearing (Gun metal) suitable for submersible pump of capacity 10 / 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 6 Sqmm 3 core complete all as specified & as directed by Engineer –in-charge.
M&L for Cleaning of RCC overhead reservoir upto 25000 gallon capacity at 60 feet staging by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge with and including writing capacity of tank , date of cleaning of tank with synthetic enamel paint on outer surface of the tank complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 28 above but RCC overhead reservoir of capacity exceeding 25000 gallon and not exceeding 0.5 Lakh gallon capacity at 60 feet
All as per Srl item No 28 above but RCC overhead reservoir of capacity exceeding 50000 gallon and not exceeding 1.5 Lakh gallon capacity at 60 feet
M&L for Cleaning of RCC underground sump upto 20000 Lakh gallon capacity at 20 feet depth by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge with and including writing capacity of tank , date of cleaning of tank with synthetic enamel paint on outer surface of the tank complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No 31 above but RCC underground sump of capacity exceeding 0.5 lakh gallon and not exceeding 1 Lakh gallon capacity at 20 feet depth
All as per Srl item No 31 above but RCC underground sump of capacity exceeding 1 lakh gallon and not exceeding 2.5 Lakh gallon capacity at 20 feet depth
M&L for Cleaning of clarifloculator of Cap 100000 Glns by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and Greasing all components by replacing the worn nut bolts of non clogging pump motor, and removing all the sludge dirt and deposits of any foreign materials etc. , painting of all the steel member channels, angles of the scrappers and mixers with two coats of bituminous based paint after preparation of old painted surface all as specified and directed by Engr-in-Charge.
M&L Cleaning of RCC raw water (back wash) sumps cap 25000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
M&L Cleaning of RCC sedimentation sumps cap 50000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
M&L for replacing of existing filter media consisting of gravel and sand in filter bed having filtration capacity 40000 Gallon per hr, cleaning of filter bed, refilling of filter bed with existing groves after carrying out necessary cleaning as per details given below all as directed by Engr-in-Charge. gallon
Removing the existing filter media consisting of grounds and sand, spreading and leveling out side for refilling, cleaning the surface, walls, bed sand Nozzles with wire brushes and cleaning the walls with bleaching power solution, washing with fresh water and finally washing the complete filter bed twice with Anti bacterial spray and ultra violet radiation treatment etc complete all respect, Anti bacterial spray and ultra violet radiation treatment, Vacuum cleaning etc complete. Refilling the filter media in the filter bed, gravels (pebbles) removed from the existing filter media after the washing pebbles with 5% concentrated solution of Hydrochloric Acid (HCL) and treatment with 10% concentrated solution of NAOH (sodium Hydro Oxide) and laying and stacking in different layers into filter beds as per details given as under :- (i) Filter gravels (pebbles) 1/8” to 1/4" - 0.6 Cum (ii) Filter gravels (pebbles)1/2" to 3/4" - 0.6 Cum NOTE : Additional sand and pebbles of different sizes required for refilling into filter bed shall be paid separately as material only under relevant item.
Supply only for filling the following filter media in filter bed duly cleaned and washed with 5% concentrated solution of HCL and treatment with 10% concentrated solution of NAOH all as directed by Engr-in-Charge.
Filter gravels (pebbles) 1/8” to 1/4".
All as per item No. 39.01 here-in-before but 1/4" to 3/8”
All as per item No. 39.01 here-in-before but 1/2" to 3/4"
All as per item No. 39.01 here-in-before but ¾” to 1 ½”
All as per item No. 39.01 here-in-before but 1 ½” to 2"
Filter sand of size 1/32” to 1/16”
S & F in repair decrin dosing pump model 96 NGQ51 high pressure single head gear motored adjustable dosing pump of specifications , Adjustable high pressure -0 to 100 PSI ,power 240 V ,50 Hz ,HP 1/30 fracional ,output -2 U.S GPD to 40 U.S GPD ,Altoch dosing system model (ADS-1) consisting of 40 ltr -100 liter PE/FRP tank with PE/FRP ltd and level gauge along with agitator with shaft & blade in plastic ,mounted on tank with accessories i.e lead tubing ,connecting nuts, injection check valve ,clay weight complete all as specified and as directed.
S&F hot water steel water tubing, 15 mm bore,medium grade, galvanised,with all fittings such as bends,tee,short piece, connectors,back nuts, diminishing pieces,caps ,plugs and union etc fixed complete to walls and ceilings or laid in floors including insulation with glass wool,wiremeshand aluminium cladding complete all as specified and directed.
All as per Srl item No 41.00 above but 20 mm dia bore.
All as per Srl item No 41.00 above but 25 mm dia bore.
All as per Srl item No 41.00 above but 40 mm dia bore.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 45.00 above but 20 mm dia bore.
All as per Srl item No 45.00 above but 25 mm dia bore.
All as per Srl item No 45.00 above but 40 mm dia bore.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. including taking out old unserviceable cable complete all as specified.
S&F in replacement Rotational moulded polyethylene water storage tanks cap 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
S&Fin replacement Rotational moulded polyethylene water storage tanks cap 2000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
Supply and fixing as in repairs Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe 25 mm dia (minimum weight 455 gms) complete all as specified and as directed.
S&F in replacement gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 54.00 above but 40 mm dia bore.
S&F in replacement Brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F 25mm bore stop valve, cast copper alloy,fancy type,chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F 20mm bore bib tap standard of chromium plated, high pressure, screwed for iron pipe and fixed complete all as specified and as directed.
Supplying & laying in trencies Polyethylene (PE-AL-PE) 15mm dia bore compositc pressure pipes includin all Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.) complete all as specified and as directed.
All as per Srl item No 59.00 above but 25 mm dia bore.
All as per Srl item No 59.00 above but 40 mm dia bore.
S&F sheet metal enclosure comprising with socket plug ,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and as directed.
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amp all as specified and as directed.
S&F in replacement of stainless steel tank of 1000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed
S&F in replacement of stainless steel tank of 2000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed
M&L servicing and maintenance of complete solar water heater plant of capacity 1000 LPD installed at single/double story buildings including carrying out repair to minor leakage, brazing work ,cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed.
M&L servicing and maintenance of complete solar water heater plant of capacity 2000 LPD installed at single/double story buildings including carrying out repair to minor leakage, cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed.
M&L disconnecting of hot water, cold water system complete and removing leakage of hot water tank by welding to tank and refixing the same complete in all respect and testing for solar water heater of capacity1000,2000 LPD complete all as specified and as directed
Supply and fixing in replacement Solar Flat Plate Collector (existing size) having made of copper absorber having 2 Sqm area including connected items as required at site to make it fully funtioning complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement gasket set for solar water heater panel suitable for 1000/2000 LPD capacity as per existing sample, including other connected items as required at site to make it fully funtioning complete all as specified and as directed by Engineer-in-charge.
S&F in replacement non return valve 20 mm bore for iron pipes complete all as specified and directed by Engineer-in-charge.
M&L rubber hose pipe 20mm dia between hot water tank & collector including dismantling & taking out existing unserviceable rubber hose pipe complete all as specified and as directed.
S & F in repair heating element of capacity 3KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specifie and as directed by Engineer-in-charge
S & F in repair heating element of capacity 2KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specifie and as directed by Engineer-in-charge
Supply and fixing in replacement of thermostatic switch (ISI marked) of range 0˚C to 80˚C suitable for solar water heater as per existing sample .
Taking up or down 15mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge. Note :-Excavation and earthwork shall be measured and paid for separately.
All as per Srl item No 4 above but 20 mm dia bore.
All as per Srl item No 4 above but 25 mm dia bore.
All as per Srl item No 4 above but 40 mm dia bore.
Rajendra Engineering Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .