Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.2 LAccepted-Finance | L-1 | Accepted-Finance Lowest bidder | |
| 2 | L-2₹29.4 L+₹21,136 (0.72%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L-2 | Rejected-Finance Highest Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Qualified |
Tender Value
₹28.2 L
EMD Value
₹56,400
Closing Date
26 Apr 2026, 11:00 amClosed
EXECUTIVE ENGINEER
ELECTRICAL DIVISION HPPWD PALAMPUR
(SH Providing fire alarm and P.A. system in passengers terminal, fire station and utility building therein).
2026_PWD_134733_1
Electrical Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Palampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹56,400
24 Jul 2026
20 Apr 2026
26 Apr 2026
20 Apr 2026
26 Apr 2026
20 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Autronica/ Honneywell (Gamewell / Bosch | 67 | Each | 4,350 | ₹2,91,450 |
| 2 | Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL/EN/VDS Certified. Make: Autronica/ Honneywell (Gamewell / Bosch | 4 | Each | 6,900 | ₹27,600 |
| 3 | SITC of Loop Powered Sounder cum Strobe with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with 32 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 92.1 dB(A), with flasher having Synchronized flash rate of 1 Hz and Light intensity > 2 cd, should have IP40 or better protection rating be programmed from the panel. Shall be EN54 / Vds/UL Certification. Make: Autronica/ Honneywell (Gamewell / Bosch | 4 | Each | 10,500 | ₹42,000 |
| 4 | Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL/EN/VDS Certified. . Make: Autronica/ Honneywell (Gamewell / Bosch | 2 | Each | 9,975 | ₹19,950 |
| 5 | Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doorsetc.. Shall be EN54/ Vds Certification/UL . Make: Autronica/ Honneywell (Gamewell / Bosch | 2 | Each | 9,975 | ₹19,950 |
| 6 | Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 / Vds/UL Certification. Make: Autronica/ Honneywell (Gamewell / Bosch | 2 | Each | 2,75,000 | ₹5,50,000 |
| 7 | SSupplying & laying of 2x1.5 spmm fire alarm armoured cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheathcomplete as required..Make Finolex/Polycab/ KEI | 2,350 | P/mtr. | 174 | ₹4,08,900 |
| 8 | Supply and erection of 25 mm dia PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. Make Diplast/Polyplast/ | 2,300 | P/mtr. | 125 | ₹2,87,500 |
| 9 | Supply, Installation, Testing and comissioning of Cabinet Speaker Max Power - 9 W ,Rated power (PHC) - 6 W(6-3-1.5), Sound pressure level at rate power /1 w ,(at1kHz,1m) (at 1 kHz, 1 m) - 96dB/ 90dB,Effective frequency range (-10 dB) - 200-15000 Hz,Opening angle (at 1 kHz/4 kHz, - 6 dB),In degrees - 150/70,Rated voltage - 100 V,Rated impedance - 1667 .Make: Autronica/ Honneywell (Gamewell / Bosch | 8 | Each | 2,800 | ₹22,400 |
| 10 | Supply, Installation, Testing and comissioning of 18U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack | 2 | Each | 46,000 | ₹92,000 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_199391.xls
BOQ • 0.30 MB
HeliportPA.pdf
Tender Documents • 4.91 MB
DECLARATION.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .