| 1 | L1₹45.8 LAccepted-AOC MALBASSA WEST DALAK AMARPUR GOMATI TRIPURA 799104 | GOMATI | TRIPURA | 799104 | L1 | Accepted-AOC Lowest tender accepted by the competent authority of TSECL | |
| 2 | L2₹53.2 L+₹7.4 L (16.1%)Rejected-Finance JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L2 | Rejected-Finance Quote price is more than L1 | |
| 3 | L3₹60.4 L+₹14.6 L (31.8%)Rejected-Finance | L3 | Rejected-Finance Quote price is more than L1 and L2 | |
| 4 | L4₹65.1 L+₹19.3 L (42.0%)Rejected-Finance SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | L4 | Rejected-Finance Quote price is more than L1, L2 and L3 | |
| 5 | Rejected-Technical DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | - | Rejected-Technical GTP of 11 KV Feeder Pillar (KIOSK) is not submiited as per NIT |
| Sl No | Description | Qty | Unit | KAJAL DAS L2 | M/S GHOSH ELECTRICAL ENGINEERING L3 | RANJAN BHATTACHARJEE L4 | SAJAL DAS L1 |
|---|---|---|---|---|---|---|---|
| 2.00Schedule A : Erection of the following: | |||||||
| 3.00 | Manually digging /drilling horizontally or diagonali direction for road crossing / Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI/HDPE pipe direct into the earth at a depth of minimum 1100mm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering In Charge.(11 KV Grade for 70 Sq mm XLPE) | 150 | Mtr | 50 ₹8,850 Lowest | 400 ₹70,800 | 493 ₹87,261 | 300 ₹53,100 |
| 4.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size through Machine Boring including laying HDPE Pipe as required Upto 70 sq. mm | 6,220 | Mtr | 320 ₹23,48,672 Lowest | 400 ₹29,35,840 | 423 ₹31,04,650.8 | 446 ₹32,73,461.6 |
| 5.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the Existing RCC/HUME/GI Pipe as required Upto 70 sq. mm | 150 | Mtr | 50 ₹8,850 | 100 ₹17,700 | 243 ₹43,011 | 20 ₹3,540 Lowest |
| 6.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation,sand cushioning, protective covering and refilling the trench etc as required.
TrenchSize:-Width-350 mm,Hieght-1200 mm/Sand (Couhioning) Hieght-250mm,Width-350 mm/protection:-Double layer Brick.
Upto 70 sq. mm | 200 | Mtr | 70 ₹16,520 Lowest | 450 ₹1,06,200 | 443 ₹1,04,548 | 300 ₹70,800 |
| 7.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of all Size in the GI Pipe/HDPE for riser including tieup of pipe with pole by the MS flat clamp(excluding cost of clamp and Nut & bolts) as required.
up to 70 sq.mm. | 430 | Mtr | 30 ₹15,222 | 50 ₹25,370 | 43 ₹21,818.2 | 20 ₹10,148 Lowest |
| 8.00 | Supplying and Making Outdoor cable termination with heat shrinkable jointing kit complet enc with all accessories including lugs suitable fo following size of 3 core, XLPE aluminium conduct cable of 11KV grade as required:
upto 70 sqmm | 39 | Nos | 2,800 ₹1,28,856 | 2,900 ₹1,33,458 | 4,903 ₹2,25,636.06 | 2,000 ₹92,040 Lowest |
| 9.00 | Supplying and Making Indoor cable termination with heat shrinkable jointing kit complet enc with all accessories including lugs suitable fo following size of 3 core, XLPE aluminium conduct cable of 11KV grade as required:
Upto 70 sqmm | 3 | Nos | 2,800 ₹9,912 | 2,900 ₹10,266 | 5,803 ₹20,542.62 | 1,900 ₹6,726 Lowest |
| 10.00 | Erection of 4 way (1 incoming and 3 out goining feedero H.T KIOSK/11 KV Outdoor type feeder pillar made of 10 SWG MS Sheet complete with aluminium busbar, HT insulator etc as required provided with locking system and painting to be fitted on structure of MS Angle(50 X 50 X6 mm) and MS flat (40X6 mm) including supply of MS Angle and Flat as required and cocreting of ration 1:2:4 with excavation of earth centering shuttering disposal of excess soil | 1 | Nos | 800 ₹944 Lowest | 1,000 ₹1,180 | 3,503 ₹4,133.54 | 1,000 ₹1,180 |
| 11.00 | Erection of 9.0 Mtr long Steel pole | 18 | Nos | 250 ₹5,310 | 200 ₹4,248 Lowest | 503 ₹10,683.72 | 300 ₹6,372 |
Tender Value
₹91.2 L
EMD Value
₹1.8 L
Closing Date
20 Nov 2025, 4:30 pmClosed
DGM, Electrical Division Capital Complex
O/O-The DGM, Electrical Division Capital Complex
Renovation of dedicated feeder of Border flood light at BOP Bhagalpur and Durgabari which were damaged during flood/storm within the jurisdiction of ESD- Durjoynagar.
2025_POWER_67073_1
DGM/EDCC/2025-26/08, dated 13/11/2025
Open Tender
Electrical Works
Works
40 days
ESD-Durjoynagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹10,000
₹1.8 L
O/O-The AGM, EC-I, Agartala, TSECL
4 Dec 2025
14 Nov 2025
20 Nov 2025
14 Nov 2025
20 Nov 2025
15 Nov 2025
14 Nov 2025 - 15 Nov 2025
15 Nov 2025
Amount
Schedule A : Erection of the following:
Manually digging /drilling horizontally or diagonali direction for road crossing / Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI/HDPE pipe direct into the earth at a depth of minimum 1100mm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering In Charge.(11 KV Grade for 70 Sq mm XLPE)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size through Machine Boring including laying HDPE Pipe as required Upto 70 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the Existing RCC/HUME/GI Pipe as required Upto 70 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation,sand cushioning, protective covering and refilling the trench etc as required. TrenchSize:-Width-350 mm,Hieght-1200 mm/Sand (Couhioning) Hieght-250mm,Width-350 mm/protection:-Double layer Brick. Upto 70 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of all Size in the GI Pipe/HDPE for riser including tieup of pipe with pole by the MS flat clamp(excluding cost of clamp and Nut & bolts) as required. up to 70 sq.mm.
Supplying and Making Outdoor cable termination with heat shrinkable jointing kit complet enc with all accessories including lugs suitable fo following size of 3 core, XLPE aluminium conduct cable of 11KV grade as required: upto 70 sqmm
Supplying and Making Indoor cable termination with heat shrinkable jointing kit complet enc with all accessories including lugs suitable fo following size of 3 core, XLPE aluminium conduct cable of 11KV grade as required: Upto 70 sqmm
Erection of 4 way (1 incoming and 3 out goining feedero H.T KIOSK/11 KV Outdoor type feeder pillar made of 10 SWG MS Sheet complete with aluminium busbar, HT insulator etc as required provided with locking system and painting to be fitted on structure of MS Angle(50 X 50 X6 mm) and MS flat (40X6 mm) including supply of MS Angle and Flat as required and cocreting of ration 1:2:4 with excavation of earth centering shuttering disposal of excess soil
Erection of 9.0 Mtr long Steel pole
Erection of Disc insulator Set for 11KV line along with necessary fittings.
Erection of 11KV pin insulator along with Pin
Erection of 9 KV KA Lightning arrestor.
Erection of MS Channel Cross arm, 1.3 to 2.8 Mtr of 75X40X40X6mm MS Channel (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of MS Angle Cross arm, 1.3 to 2.8 Mtr of 65x65X6mm MS Angle (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of MS Channel Cross arm, 0.3 to 1.2 Mtr of 75X40X40X6mm MS Channel (Excluding the cost of Back Clamp, Nuts & Bolts)
Laying & strining of 1KM (Single Conductor) ACSR 6/1/2.59 Wease Conductor including hoisting & binding et Complete as required.
Erection of 11 KV GOS (3-Ph)
Fabrication of Cross arm by Channel/Angle as per specification
Schedule B : Earthing
Earthing with G.I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.I.Pipe, Salt & Charcoal, Gi wire, nuts &bolts, etc. as required)
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Supply of 60Kg Salt & 55Kg Charcoal (For 1 Pit).
Supply of 2.5mtr. Long, 40mm dia G.I.Pipe Make: TATA/ JINDAL)
Supply of MS Nuts & Bolt ic Washer of assorted size ISI Marked machine made
Schedule C : Supply
Supply , Erection testing and Commissioning of 11 KV Vaccuum circuit Breaker 1250 Amp continously current 350MVA complete indoor VCB With Metering Arrangement as per technical specification including supply of 2 nos Vaccuum interrupter, 2 nos closing and 2 nos tripping coil, 2 nos auxiliary switch etc. as spare.
Providing of of Pre-cast cement concretecable identification route marker (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement: 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, ELECTRIC POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint. (1 cement: 2 coarse sand: 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement: 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits.
Supply HDPE pipe PE 100 Grade, PN 8(SDR) 110 mm outer dia wall thichness Minimum 6.5mm Maximum 7.3 mm.(6 Mr long Each)
Supply of febricated clamps of assorted size of MS flat (50 X 6 mm) with double coat of red oxide primer coating
Supply , Erction testing and Commissioning of 11 KV HT 4 way outdoor type 14 feeder pillar- Kiosk withnecessary fittings and structures complete as per technical Specification.
Schedule D : Civil Work
Grouting of 18 No steel tubular poles of ratio 1:2:4 ( 1 cement : 2 river sand : 4 Jhama brick aggregate of 20mm nominal size) inchluding supply of cement sand and brick aggregate complete with excavation, refilling of earch, ramming alongwith centering & shuttering as reqd. @ 0.273 Cum per pole.
Cable Trench (750x800 mm)
Schedule E : Carrige of Materials : -
Carriage of Line materials such as cable, ACSR, G.I. Wire Cross-Arm, Stay Set, insulator etc. By Mechanical Transport from A.D. Nagar Store Sub-Division to work site.
Carriage of G.O.S,D.O.F,LA,etc by Mechanical Transpot from from A.D. Nagar Store Sub-Division to work site.
Carriage of 9mtr. Long Steel Tubular Pole from AD Nagar/Bodjungnagar Store to to work site.Formaximum 8 poles
Carriage of 9mtr. Long Steel Tubular Pole from AD Nagar/Bodjungnagar Store to to work site.Beyond 8 poles
KAJAL DAS (BID ID -193280)
M/S GHOSH ELECTRICAL ENGINEERING (BID ID -193338)
RANJAN BHATTACHARJEE (BID ID -193281)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.56 MB
Document
1.92 MB
BOQ
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .