Loading…
Loading…
Tender Value
₹8.4 Cr
EMD Value
₹8.4 L
Closing Date
19 Jun 2026, 6:00 pm
Chief Officer, Mansa Nagarpalika
Bid Document for Construction Of Protection Wall & Miscellaneous Work At Malav Lake(Part-II).
309984
01 of 2026-27
Open
Civil - All
Gandhinagar
3 documents required · 3 mandatory
₹14,160
Chief Officer, Mansa Nagarpalika, Mansa
₹8.4 L
30 May 2026
30 May 2026
30 May 2026
19 Jun 2026
30 May 2026
CONSTRUCTION OF PROTECTION WALL (PART-2) AT MALAY LAKE AT MANSA, FOR MANSA NAGAR PALIKA, DISTRICT: GANDHINAGAR.
Sr. Description Quantity Unit Rate Amount
(With LC) (2024-25)
Demolition and disposal of unserviceable
material with all lead and
lift.(ii)unreinforcement cement concrete.
Excavation for foundation upto 1.5 m depth
including sorting out and stacking of useful Pg.67,
2 materials and disposing of the excavated 1743.00 Cu.M. 121.91 123.13 It no,
stuff upto 50.Mtr lead(A) loose 04001A
Excavation for foundation upto 1.5 mt. to
mt. including sorting out stacking of useful Pg.67,
3 material & disposing of excavated stuff upto 1743.00 Cu.M. 168.81 170.50 It. no
50.Mtr lead(B) Dense or Hard 04002B
Excavation for foundation for depth from
m to 5.0 m including sorting out and stacking Pg.68,
4 of useful materials and disposing 8 off the 2158.00 Cu.M. 181.13 182.95 It. no
excavated stuff upto 50 Meter lead.(B) Dense 04003B
Extra for additional depth more than 5.0 m
for excavation for foundation including
sorting out and stacking of useful materials
and disposing off the excavated stuff upto
m lead.(B) Dense or Hard soil
Providing and laying cement concrete 1:2:4
(1 cement : 2coarse sand :4 graded stone Pg.74,
6 aggregates 20 mm nominal size) and curing 323.70 Cu.M. 3720.98 3758.19 It.no-
complete excluding cost of formwork in(A) 05010AA
Foundation and plinth
Providing and laying cement concrete 1:3:6
(1- Cement . 3- Coarse sand : 6- Graded brick
bat aggregate 40mm normal size) and curing
complete excluding cost of formwork in (A)
Foundation and Plinth
Providing and laying controlled cement
concrete work M250 and curing complete
including the cost of forrr work but excluding
the cost of reinforcement of reinforced
8 concrete work in foundation, footings base of 2061.00 Cu.M. 4473.58 4518.32 RA-1
column and mass concrete. (A) Footing/ Raft
Providing and laying M.S. side rail of road
thickness with necessary nut bolt plates.
9 Fixing as per width ,applying plate vibrator 1290.00 Sq.M. 160.00 161.60 M.R
electric or diesel on channel complete with
V.D. system (trimix) by using the all
necessary equipment and materials and
Supplying premoulded bituminous joints Pg.179,
filler(i)12 mm thick. It.no-
Providing and laying controlled cement 26017A
concrete work M250 and curing complete
including the cost of form work but
excluding the cost of reinforcement of RA-2
11 reinforced concrete work in Walls from top 750.20 Cu.M. 6281.49 6344.31
of foundation level upto floor two level. Wall
Providing and laying controlled cement
concrete M.250 exposed work with curing RA-3
12 etc. complete including the cost of formwork 1753.38 Cu.M. 8184.11 8265.96 Exposed
but excluding the cost of reinforcement for RCC Wall
R.C.C. work in Wall
Providing and fixing premoulded
compressible filler board in black colour
confirming to MoRT&H Specifications
(Clause 1015), having minimum density
95kg/cum. non-staining with less than 1% Pg.85
13 water absorption & compression recovery of 33.80 Sq.M. 795.27 803.23 It. No,
93% minimum as per specification for 20
mm wide expansion joint including cutting to
required size and shape at all levels
etc.complete as directed.
Providing TMT Bar FE 500D reinforcement
for R.C.C. work including bending, binding Pg.75
14 and placing in position complete upto floor 596511.00 Kg 76.52 77.29 It. No,
two level 05014C
Filling available excavated earth (excluding
rock) in trenches. Plinth, sides of foundations
etc. in layers not exceeding 20 cm. in depth Pg.69,
15 consolidating each disposited ayer by 11703.00 Cu.M. 135.56 136.92 It no
ramming and watering. ._...
Demolition of Brick work and stone masonry
including stacking of serviceable materilas
and disposal of unserviceable materials with
all lead and lift. (i) In Lime
Filling in foundation and plinth with murrum
or selected soil in layers of 20cm. thickness It.:
including watering, ramming and Code-
consolidating etc. complete. 4008A
providing and mixing water proofing It.:
material in cement in mix proportion Code-
recommended by the manufacturers.
Providing and fixing to wall ceiling and floor
10.0kg F/cm2 working pressure poluthene
pipes of the following outside dia low density It.:23.8
complete with specials flange compresion Code-
type fittings, wall clips etc. including making 23004F
good the wall ceiling and floor P.:
SUPPLYING AND ERECTION OF FLOOD LIGHT POLE FOR MALAV LAKE AT MANSA.
Sr. No. Description Quantity Unit Rate Amount
Making trench in Hard Murrum / Tar Road of
suitable width of 90 cms or required depth
for laying any size of cable or locating the It No.-
1 fault all over the run and back filling the 660.00 R.Mt. 62.00 62.62 4-5-2
same and making the surface as normal
Supplying & erecting Steel tubular pole
(Swaged) confirming to IS - 2713 (Part-II)
1980. Manufacturing process of steel tubular
pole should be as per IS specification. Basic
steel tube should be ISI Marked. Pole should
be painted by one coat of Zinc comet Primer
and two coat of Aluminium /approved paint
to be erected on / in existing Foundation.
The length of poles are as below.
(F) 12.00 mtr. Long Swaged Steel tubular
pole as per IS code 410-SP-58 with 450 X
X 6 mm base plate with necessary G.I. J Bolts
(Approximate weight 186 Kg) For burial It No.-
erection with ladder on pole at minimun 6-1-3-F
distance between two step is 1 ft to 2 ft. with
suitable 6 Nos flood light with brackat (ii)
ADD Extra for M.S. Base plate 400 X 400 X
mm for pole, mounting on surface of
foundation on GI foundation bolt. with
required stiffeners. (iii) Add Extra for PU
base primer and PU Paint on pole.
Supplying and erecting LED street light /
Flood light fittings with High power White
LEDs wattage of 1Watt and above assembled
on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die
cast aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate
optics/ lenses with company mark/name
engraved or embossed
120 to 300 V,Power Factor more than 0.95,
THD < 10 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaire efficacy>
3 85 lumens/watt . LED driver efficiency > 85 9.00 Nos. 9552.00 8489.00 It-2-16-2
CREE / OSRAM / PHILIPS Lumileds / NICHIA
/ SEOUL/ BridgeLux (U.S.A.) make LED used
for luminaire. ( Each fittings required LM-79
& LM-80 certificates)
(B) Flood Light (IP-65), Surge protection -
4KV integral and ,Light must have 440VAC
line supply with over-voltage protection.
(vi) above 160 to 200 watts
Supplying and erecting LED street light /
Flood light fittings with High power White
LEDs wattage of 1Watt and above assembled
on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die
cast aluminum housing with smooth finish
powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate
optics/ lenses with company mark/name
engraved or embossed
120 to 300 V,Power Factor more than 0.95,
THD < 10 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaire efficacy>
4 85 lumens/watt . LED driver efficiency > 85 9.00 Nos. 10711.00 10818.11 It-2-16-2
CREE / OSRAM / PHILIPS Lumileds / NICHIA
/ SEOUL/ BridgeLux (U.S.A.) make LED used
for luminaire. ( Each fittings required LM-79
& LM-80 certificates)
(B) Flood Light (IP-65), Surge -4KV
(d) 200 to 250 watts
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv grade
ISI marked copper wires of following size to It No.-
be erected as directed. 1-4-5 ( h)
h) 2.50 Sq.mm 3 core round PVC sheathed
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
6 necessary clamps or in existing trench / pipe 792.00 R.Mt. 130.00 131.30
of following size of cables. (D) 3 core 10 Sq.
“ B ” class Galvanised iron pipe having
smooth finished bore of the pipe on both
ends erected nuts and bolts along the pole / It No.-
wall shaping the pipe as per site 6-5-5 ( C )
requirement. Pipe dia as following.
(c ) 40 mm dia.
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
insulated armoured cable complete with out It No.-
going tails, insulating tape etc for following 4-6-3
size of cables.
(b) 3x1/2 core 35/50 Sq. mm
Cast iron earth plate size 30 X 30 X 0.35 cms.
buried in specially prepared 2.5 Mtr. deep
earth pit complete with necessary G.I. strip
9 in G.I. pipe 2 Mtr. long with coupling and G.I. 1.00 Each. 679.00 685.79
plug for earthing of switch gear, conduit run
or power plug etc.
ADD Extra for excavation in Hard rock by dry
10 and wet blasting and chiselling for funnel 1.00 Each. 380.00 383.80
type earthing of above .
For using salt and charcoal / coke as It No.-
11 required for pipe type earthing. 1.00 Each. 170.00 171.70 3-14-6 (C
Providing and erecting Annealed bare It No.-
Copper wire 8 to 16 SWG. 3-14-4
Supplying & erecting IP 55 grade following
size section pillar fabricated from joint less
M.S. Sheet with angle iron legs made from
jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate
erection to work uniform until erected with
cement concrete foundation and 45 cms high
bricks work finishing with plaster etc. hinged
double door internally supported on both
side, with internal and outside looking
arrangement with look and keys in duplicate
35 x 35 x 5 mm M.S. Angle of Two Nos. one is
welded and other with nut and bolt for It No.-
erecting bakelite sheet. Painting the Section 6-6-1
Pillar inside and out side with three tank
powder coated paint. section pillar roof
should be without joint with water leakage
proof & tested as per IP 55 test & followed by
(A) 150 X 90 X 75 cm section pillar fabricated
from 14 Guage MS Sheet with angle iron legs
95 cms long made from 40 X 40 X 6 mm thick
Supplying and erecting bakelite sheet 8mm
14 thick HYLAM make on existing angle iron 1.44 Sq.Mtr 1526.00 1541.26
Approved make Four pole moulded case
circuit breaker having breaking capacity ICU
of 35 KA. at 415 V. having normal current
rating up to 125A. with Fixed thermal &
magnetic release suitable to work on
A.C.supply 50 c/s. with all internal
connections & complete erected in existing
16 G.M.S. housing.
Supplying & erecting power contactor for
time switch complete erected as per It No.-
direction Cat III 6-7-5
[D] 4 pole 440V 40 Amp.
Erection & connection Charges for 63A/100A
TP as following It No.-
(b) Erection on angle iron frame duly 3-1-7
painted with Red Oxide
Providing and erecting busbar chamber
confirming to IS-375 fabricated from
G.M.S. sheet, dust & vermin proof having
hinged door with rubber gasket and
necessary busbar supports with COPPER
busbar having current density not more than
1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour
18 insulation tape for phase sequence, three 3.00 Rmt. 5675.00 5731.75
phase & neutral each suitable for following
current capacity with necessary painting
mounted on wall or pedestal frame of
required size with necessary connections.
(B) Suitable for 200 Amp. capacity
Providing Approved make Triple Pole Metal
Clad Switch Fuse Unit 415/500 V. with HRC
19 fuse of suitable load and neutral link 3.00 Nos. 2085.00 2105.85
confirming to IS.
(a) 32 A Cat III
Providing and fixing Terminal board of size
5.0 x 127 x 152.4 mm.bakelite sheet with
Amp. kitkat pattern porcelain fuse unit with
20 suitable brass studs with nuts, washers and 1.00 Nos. 145.00 146.45
clamps of size 25mm x 3mm suitable for pole
painted with one coat of red lead paint.
Providing and erecting cable clamp of 25 mm
X 3 mm M.S. flat suitable for fixing 2 Nos.of
21 armoured cable with nuts and bolts. 2.00 Nos. 111.00 112.11
(c) for 140 mm dia. Pole
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II
)with necessary connecting accessories of
22 same material at required depth in existing 660.00 Rmt. 73.00 73.73
trench for laying of cable. below ground /
road surface for enclosing cable
(B)63mm outer dia
Pipe type earthing having 150 cms.long and
2.5 cms. dia. galvanised iron pipe with
23 coupling and buch buried in specially 1.00 Nos. 365.00 368.65
prepared earth pit complete with necessary
8 SWG earth wire.
Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of
following size evenly crimped with high
24 pressure tool & connected to switchgear 40.00 Nos. 20.00 20.20
terminals with brass/cadmium plated nut
bolts in an approved manner.
Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of
following size evenly crimped with high
25 pressure tool & connected to switchgear 12.00 Nos. 15.00 15.15
terminals with brass/cadmium plated nut
bolts in an approved manner.
Supplying & erecting approved make Digital
time switch having lithium cell 6 years
operative and operate battery backup
channel day clock with 14 memory
programme, suitable to operate on 240V +
5%, 16A with, floating contacts Minimum
switching setup time 1 minimum & LCD It No.-
display. Also comprised permanent ON/OFF 6-7-2
switching. Programming switches & housed
in fire proof thermoplastic enclosure &
transparent cover erected as required with
necessary connection erected as directed.
MANSA NAGAR PALIKA
SUPPLY AND ERECTION WORK OF CCTV CAMERA AT MALAV LAKE AT MANSA.
Sr. Description Quantity Unit Rate Amount
(With LC) (2024-25)
4 MP BULLET VERYFOCAL NETWORK
Image sensor-1/2.9' cmos,resolution-
2688(H) x 1520(V),min illumination-0.006
[email protected] ( color, 30 ire),0.0006 [email protected] (
b/w, 30 ire),0 lux ( illuminator on
),illuminator distance- up to 60 m ( 196.85 ft)
( ir led ), pan: 0-360, tit: 0-90, Video
mjpeg, certificaion:- CE-LVD : EN62368-
CE-EMC : ELECTROMAGNETIC
COMPATIBILITY DIRECTIVE
2014/30/EU; FCC: 47 CFR PART 15, SUB
PART B; ,UL/UCL: UL62368-1 & CAN/CSA
3 16 PORT POE SWITCH 2.00 Nos 10980.00 11089.80 M.R.
4 HARD DISK 4 TB 1.00 Nos 12536.00 12661.36 M.R.
6 HEAVY CAMERA BOX 24.00 Nos 150.00 151.50 M.R.
7 CAT 6 CABLE WITH PVC PIPE LAYING 800.00 MTR 75.00 75.75 M.R.
FIBER CABLE WITH HDPE PIPE LAYING
9 INSTALLATION CHARGE 20.00 Nos 750.00 757.50 M.R.
10 SFP MODUAL 6.00 Nos 2250.00 2272.50 M.R.
Computer System
Processor-12th Gen Intel® Core™ i7-12700
(25 MB cache, 12 cores, up to 4.8 GHz
Turbo), Operating System- Windows
Home, Graphic card - Intel® UHD Graphics
770 with shared graphics memory, RAM -
8GB DDR5, 1x8GB, at 4400 MT/s, ROM-
512GB M.2 PCIe NVMe Solid State Drive,
Realtek Wi-Fi 6 RTL8852BE, 2x2, 802.11ax,
MU-MIMO, Bluetooth® wireless card, 22"
LED Monitor, Key board and Mouse with
basic software and 1 year anti virus software
SUPPLYING AMPLIFIER SSA5000DP
RCA to Sockat for CD player perallel to Aux-2
Built in MP3 player with remote control, for
USB, SD MMC card.
Pller and Line Output for connBC: Amplifier.
Line input for connecting the output for
midia any external mixer another amplifier.
In Watt 16fot to DC power (cat Battery) in
Box Speekan'D"-' Unit swithch. Bass boost
defeated at drum Unit.
SUPPLYING PROJECT SPEAKER SP-6305TD
Compact & elegant controlled directivity
sound projector inaeshetically beautiful
white plastic cabinet, water resistant
16 speaker used SP-5251T is suitable for 20.00 Nos 2950.00 2979.50 M.R.
outdoor application also
11.43 cm full range speaker 25w/100v easy
Supplying of SPEAKER CABLE 1.5SQMM
2CORE Specification:
Conductor – No/ Size of Wire-48/0.20mm
Insulation Dia. -2.90mm
DC resistance @20 °C – Conductor- 13.7.0 Ω /
17 Operating Voltage- 600v 1000.00 Rmt 42.00 42.42 M.R.
Inductance – (1kHz at 20 °C) -0.7 μH/m
Capacitance – (1kHz at 20 °C) -97pF/m
Insulation resistance -10000 M x m Min. at
Dielectric Strength -2 (KV/1 Min.) DC
Design, supply, Testing and Commissioning
Multi-Purpuse Micophone, Excellent
sound quality. Ideal for spoken word,
karaoke, multimedia, and instrument use,
18 Frequency Response 50-15000 hz, 2.00 Nos 2200.00 2222.00 M.R.
impedance 600 ohms, output level -
52dbv.Multipurpuse Microphone Approved
make :-Shure/TOA/ Audix
CABLE LAYING / SPEAKER INSTALLATION/
19 AMPLIFIER CONFIGRATION 1.00 Job 10000.00 10100.00 M.R.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DTP.pdf
Price Bid.pdf
Schedule B.pdf
2.1 Material specification.pdf
2.1 Specification for building works (1).pdf
2.1Electrification Specification Work.pdf
05 Plumbing Specification.pdf
DTP-R.pdf
Download all tender documents and submit your bid