Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹51.1 L+₹4.8 L (10.5%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Accepted | |
| 3 | L3₹51.9 L+₹5.7 L (12.4%)Rejected-AOC 5D 32B GALI NO 8 VISHNU GARDEN TILAK NAGAR WEST DELHI 110018 | DELHI | WEST DELHI | DELHI | 110018 | L3 | Rejected-AOC Accepted |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
23 Feb 2022, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Special repair to roof of bldg No P-97,P-52 A, P-53 A, Provn of fencing, hard standing and vehicle parking shed for bldg No-T-41 beacher road, santry post in Acita trg area, 05 toilet block at bldg No-T-37, RCC framed structure with barbed wire fence
2021_MES_489076_3
8370/A/E8
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹94,000
28 Feb 2022
4 Feb 2022
26 Feb 2022
4 Feb 2022
23 Feb 2022
12 Feb 2022
Amount
Surface excavation/dressing not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Rough excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in any type of soil for cutting in slope for laying of pipe etc and getting out complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in any type of soil for foundation, etc. or for shafts, wells, cesspits, manholes, pierholes, cable etc. and getting out complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.50 cum,in any type of soil getting out soil, removing to a distance n exc 50 m & making good surface complete all as specified.
Returning, filling in soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed
M & L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete as in sub base floor complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:6) complete all as specified and directed (using old size bricks).
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:4) complete all as specified and directed (using old size bricks).
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls but in in cement mortar 1:4 (using old size bricks) complete all as specified.
M&L for cement concrete 1:2:4 type B-0 (using 12.5 mm size graded stone aggregates) 40mm thick in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L for broken stone hard core of gauge n. exc. 63mm deposited, spread and levelled in layer n. exc. 15cm thick watered and rammed to a true surface complete all as specified and directed
M&L for moorum/ red bajari filling in floor or pavings, laid in layers n exc 15 cm thick. Spreading,levelling and well ramming including watering and rolled to a true surface, complete all as specified and directed
Taking down cement or cement lime plaster on walls of any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work in CM 1:6 and finished surfaces even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 15mm thick in cement mortar 1:4 on walls (fair / unfair finished faces of brick/concrete), finished even and smooth without using extra cement complete all as specified.
M&L 5mm thick plaster in CM (1:3) on fair faces of concrete ceiling surfaces,finished surfacese even & smooth without using extra cement complete all as specified.
M&L non skid ceramic coloured tiles joint free tiles 7 to 8mm thick ,area of each tile exc. 0.11 Sqm but not exc. 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with & over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic digital coloured tiles of size 375 x 250 x 6 to 7mm as on vertical surfaces such as skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished roung to fix tiles complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350 x 250 x 6 to 7mm/ 450mm x 350 mm x 6-7 mm thick as on vertical surfaces such as skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished roung to fix tiles complete all as specified and directed.
M & L for coloured prepolished rubber moulded chequred cement concrete tile 30 cm x 30 cm x 20 to 22 mm thick with spacers 3mm , set, jointed and pointed in neat cement slurry as in floor with grey cement and pigment over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness , M- 35 grade, set, jointed and pointed in neat cement slurry in floors with grey cement & pigments complete all as specified and directed .
M&L for heavy duty skid proof vitrified coloured parking tiles n.exc0.18 sqm each tiles , 10 mm thick (square/rectangular) in floor, parking, path etc, jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed..
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection, finishing the surface even & fair without using extra cement the plinth protection shall be laid in alternate bays n exe 2 Sqm, 10mm joints shall be provided, joints shall be filled with bitumen mastic, bitumen mastic comprise of 1 Part of Hot bitumen 85/25 grade and 3 parts of sand all by weight complete all as specified & directed.
M&L mirror finish machine cut kota stone slab18-20 mm thick flooring in step, floor etc over and including 15mm CM 1:6 screed bed laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing, rounding of edges & polishing complete all as specified
M&Lmirror finish machine cut Kota stone slab 12 to 15 mm thick, as on vertical surfaces such as riser of steps, skirting, dado etc. over & including 10mm thick rendering (bedding layer) in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, rounding of edges and polishing complete all as specified.
M&L for taking down existing roof treatment of felt etc any thickness or description including cleaning all upto roof slab incluing removing spoil form site and M&L for providing roof treatment as per the following steps :- i) Filling cracks of roof slab with approved chemical sealing compound and applying 15mm thick renedering in CM 1:4 over neat cement slurry @ 3.00 Kg/Sqm over cleaned roof surface with use of approved water proofing compoung. ii) Applying a coat of polymeric primer @ 0.30 Kg/Sqm followed by APP based polymeric water proofing membrane 3mm thick, minium weight 3.60 Kg/Sqm reinforced with plyester non-woven fabric (weight not less than 150 gms/Sqm) centre core including coating the surface with the compatible primer and torch application of membrane with 10 cm overlap as required there of, (iii) applying one coat polymeric bitumen85/25 gde @ 1.2 kg/ sqm complete laid as per the manufacturers instruction Note : (i) The work of water proofing treatment shall be got executed through manufacturer or authorised applicator only. (ii) Water tanks if any on roof surface will be taking down & re-fixed in same position after roof treatment work with out any extra cost.
M & L for 25 mm thick Cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub floor,levelling course,kerb on roof slab / chajjas/ junction of parapit etc with chicken wire mesh netting etc complete all as specified and directed.
M & L for Cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floor base,padding on roof slab etc complete all as specified and directed.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor for laying floor finish complete all as specified and directed.
M&L for 75mm thick cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in sub base of floor for laying floor finish complete all as specified and directed.
M&L RCC 1:2:4, type B1(using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified.
M&L RCC 1:2:4, type B1(using 20 mm graded stone aggregate) as in beams, cantilevers, bressumers, lintel over 1.5 m clear span etc, complete all as specified.
M&L RCC 1:2:4 ,type B-1(using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M & L RCC 1:1.5:3 type A1 using 20 mm graded stone aggregate as in column footing including raft footings, foundation, plinth beam, bases of columns etc. complete all as specified and as directed.
M & L RCC 1:1.5:3 type A1 using 20 mm graded stone aggregate as in columns, pillars, posts and struts etc. complete all as specified and as directed.
M & L RCC 1:1.5:3 type A1 using 20 mm graded stone aggregate as in roof beam, cantilevers, lintel chajjas etc. complete all as specified and as directed.
M & L RCC 1:1.5:3 type A-1 using 20 mm graded stone aggregate as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L for form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work for fair finished surface of concrete complete all as specified and directed.
M&L for form work to columns , pillers and similar work, square,rectangular or polygonal for fair finished surface of concrete, complete all as specified and directed.
M&L for form work to soffit and sides of concrete slabs supported on walls and similar work for fair finished surface of concrete complete all as specified and directed.
M&L for form work to soffit and sides of beams and similar work for fair finished surfaceof concrete complete all as specified and directed.
M&L for form work to edges of concrete floors ,break in floors , window cill,concrete railling etc for fair finished surface of concrete, exc 10 and n exc 20 cm wide , complete all as specified and directed.
S & F mild steel work in angle iron or other stock section or core for wooden hand - rail straight portioon, drilled and countersunk for balusters, nosing of steps, including embeding in concrete and screwing etc. wind ties for foof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe – 290 Gde E -165 complete all as specified and directed.
S&F mild steel TMT bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia as specified .
M&L TMT bars 5mm dia and over upto and including 10 mm dia, as in stirrups, spacers, binders etc, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F TMT MS bar 6 to 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as specified and directed .
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping, benching,roof kerb,bed blocks etc including necessary weathering, slightly rounded or chamfered angles and throating,form work etc complete all as specified and directed.
M&L in repair rendering 15mm thick in cement mortar 1:3 mixed with water proofing compound on fair faces of chajjas, roof projection,facia ,finished even and smooth with out using extra cement , complete all as specified. (Note:- Water proofing compound where ever ordered shall be added and the same will be measured and paid separately)
Supply only liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed.
S&F in repair aluminium powder coated windows and ventilator shutters, without sash bars aluminium section weighing 0.55Kg/ Sqm including necessory joining cleats, glazing clips, rubber packing ,anodised aluminium beading,screws, glass ,aluminium hinges, handle tower bolt etc including making good the disturbed surface complete all as specified.
S&F factory made 100% solid wood plastic composite (WPC) door frame of size 75 mm x 50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof termite proof fire retardant and having good screw holding capacity all as specification and drawing complete all as specified and as directed
S&F 24 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified and as directed.
S&F powder coated aluminium grill with mesh size 75 mm and aluminium bar 6 mm XPM type including all accessories such as channels for fixing grill screws etc. aluminium section 15 micron thick anodizing complete all as specified and directed.
S&F powder coated aluminium ventilator fixed type half glazed and half gauged with and including hardware fittings, glazing, wire gauge, rubber packing, aluminium beading etc. as specified below , complete all as specified : - Frame : 44.5 x 44.5 mm x 1.80 mm thick Middle rail : 44.5 x 44.5 mm x 1.80 mm thick Glazing: 5 mm thick frosted glass fixed with rubber gasket and aluminium beading. Wire gauge: stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium beading.
S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or weldedcomplete all as specified & directed.
S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified & directed.
S&F 150 mm long,aluminium,anodised, barrel tower bolts of extruded section ISI marked complete all as specified and directed.
S&F alluminium anodized handle, fabricated type,size150mm, ISI marked complete all as specified and directed .
M&L stainless steel butt hinges, medium weight ,100 mm size ,gde-202, complete all specified.
Supply and fix 300 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F mild steel framed work for such as grills, grating,door frames etc with end of bars shouldered and/ or riveted forged into spikes, framed guard bars barred iron door, railings and similar work complete conforming to Fe-290 Gde E 165 complete all as specified & directed.
S&F structural steel work as in roof trusses (framed), trussed, purlins crane gantries, rails & fastenings & heavy brackets framimg (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc. Structural steel conforming to Fe-410W, Grade-E 250, Quality 'A' .
S&F structural steel work in tubular trusses ,posts/poles, including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1998 grade ST -240 quality - A complete all as specified
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed .
M&L Pre-painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strangth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Acrylic PVC sheeting 2-3 mm thick fixed with screw and washer in gate/ fencing,roof, wall etc complete all as specified and as directed .
Dismantling of disstressed concrete by chiseling from RCC members (Beam, column, Slab, Chajja, facia, Wall, etc) and exposing the reinforcement without disturbing the core of RCC member and cleaning the surface with wire brushing including cleaning the reinforcement free from rust by sand blasting and reinforcing the surface with and including 100 mm x 100 mm x 3 mm welded mesh and anchoring it with 1.35 m centre to centre and cleaning the surface with water under compressed air pressure and Guiniting pressure @ 20-30 N/SqCm with Admixture (One part of cement and 3.5 part of sand) of thickness 40 mm average incl stripping, floating with wooden strippers for proper dimension and necessary form work, scaffolding & removing of waste material etc all as directed . Note: (i) All precautionary measures shall be taken to avoid damage of existing structure otherwise contractor shall be responsible to make good of the existing structure.
M& L for Cutting of existing road by mechanically/ manually for any size pipe for the sewage/drain pipe / cable protaction pipe etc and making good surface with PCC1:3:6 type C-1 and road patchment material etc to match existing surface complete all as specified and directed.
Supply only MS chain link fencing 3mm dia, GI plain wire, 50x50mm mesh or type weight n.exc 4 kg per square meter complete all as specified and directed.
Fixing only chain link fencing, including line wire any mesh, size & type to any type of standard rail, straining bolt etc, including provision of binding wire.
S&F mild steel screw bolts 11 to 15 mm dia (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 15 cm but n exc 22.50 cm long complete all as specified.
S & F galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, straining bolts at ends, staples or steel pins etc. ( Each line wire to be measured) complete all as specified and directed.
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10cm girth in Brick/ RCC complete all as specified and directed.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F vitreous china wash hand basin with brackets, white, size 550 x 400 mm including CP brass 32mm waste fitting with long screwed shank and fly-nut, 32 mm PVC waste pipe including cutting for and pinning in ends of brackets complete all as specified and directed.
S&F vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest fixed with cement joint and providing lime concrete bedding and connecting to flusing cistern including 'P' or 'S' trap of CI complete all as specified and directed.
S&F Vitreous China urinals, half stall, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe complete all as specified and as directed.
S&F chromium plated stop valves/ angle valve 15 mm bore ,cast copper alloy, screwed down high pressure, with crutch or butterfly handle, screwed both ends , complete all as specified .
S&F PVC connection 15mm size with PTMT nuts, of 450 mm length complete all as specified and directed..
S & F 15 mm bore bib taps, chromium plated cast copper alloy long body, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F 20mm dia brass chromium plated tubular towel rails, D type, 60cm long between flanges, complete all as specified.
S&F 75 mm dia PVC (SWR) multi floor trap, with CP grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
S&F110mm PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches/ wall with PVC clamp and holder bats complete all as specified.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches/ wall with PVC clamp and holder bats complete all as specified.
S & F PVC (SWR) bends, reducer any radius with rubber ring joints, fixed to wall / floor / in trenches complete all as specified and directed for 110 mm dia pipe complete all as specified and directed.
S & F PVC (SWR) bends, reducer any radius with rubber ring joints, fixed to wall / floor / in trenches complete all as specified and directed for 75 mm dia pipe complete all as specified and directed.
S & F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F Bib tap long body15 mm dia standard of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified.
S&F 15 mm dia swan neck pillar taps, cast copper alloy , chromium plated screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe , complete all as specified and directed.
S&F 10 ltr capacity PVC low level flushing cistern including PVC syphon and float valve with PVC long band for out let connection of cistern with WC complete fixing the cistern with wall in pressured connecting with WC complete all as specified and directed
S&F gun metal globe or gate valve of size 20mm dia with iron wheel head screwed both ends and for iron pipe & fixed complete ISI marked complete all as specified and directed.
S&F rotational moulded polyethylene 500 Ltrs Capacity water storage tanks three layered, (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball valve 20 mm size PTMT, with polythelene float and fly nut and 20mm dia GI medium grade wash out pipe , approx lenght 0.45 mtr, with pluged at one end complete all as specified and directed.
S & F 150 mm bore UPVC (SWR) pipe 4 kgf/cm2 single socketed in any length with rubber ring, fixed on wall/floor/trenches including Tee,bend,socket and packing in cement morter,etc complete all as specified.
S & F soap dish, brass, 100x100x60mm chromium plated,fixed to wall with rawl plugs and chromium plated screws complete all as specified and directed.
M&L for precast RCC (1:2:4) type B1 (using 20mm graded stone aggregate),as in cover slabs of manholes, open drains etc inclusive of form work and set in CM (1:4) complete all as specified and directed. (Note:- Reinforcement shall be measured and paid separately).
S&F, laying, jointing and testing salt glazed stone ware drain pipe 150 mm Internal dia, grade ‘A’ confirming to IS–651–1980 laid in trenches and jointed in cement mortar 1:1 complete all as specified.
S&F, laying, jointing and testing salt glazed stone ware drain pipe 200 mm Internal dia, grade ‘A’ confirming to IS–651–1980 laid in trenches and jointed in cement mortar 1:1 complete all as specified.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe complete all as specified and directed.
M&L for cutting into existing manholes/septic tank for removing existing branch connecting 200mm bore pipe including removing existing branch drain pipes of 200/150mm bore & benching to form branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) surface finished and reforming benching as required and making good surface with plaster etc to match existing , etc complete all as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer including preparation of new steel or iron surfaces of any description exc 10 cm width or girth, complete all as specified and directed.
M&L for preparation of wall and applying exterior grade wall care putty 2 to 3mm thick to make the surface smooth complete all as specified and directed.
M&L for three coats of white wash on new untreated wall surfaces of any description including preparation of surfaces complete all as specified and directed.
M&L for three coats of white wash on new untreated ceiling surfaces of any description including preparation of surfaces complete all as specified and directed.
M&L for complete removal of existing treatment of old walls etc including corneces with scrapping, wire brushing and washing with water and applying two coats of exterior grade weather proof paint over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for two coat of cement base paint on external already putty surfaces of walls etc complete all as specified and directed.
M&L for two coat of cement base paint over a coat of suitable primer on external surfaces of walls etc including preparation of new surfaces of any description,complete all as specified and directed.
M&L for preparation of plastered/unplastered surfaces of walls and applying two coat of cement base paint on external old wall surfaces complete all as specified and directed.
M & L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC surface conduit not less than 19 mm dia, clip, complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including MS Box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified including lugs required for following :-
One light point point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
S&F switch piano flush type single pole, 5 Amps, one way all as per specified & directed.
S&F socket outlet 6 Amps, 5 pin, 2 in 1 complete all as specified and directed.
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm. complete all as specified & directed.
S&F wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 4000K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make:Wipro Cat part No LL20-281-XXX-65AL1/ Philips cat part No BN021C LED20S PSU CWGR S2/Havells Cat No ENDURA LINEARNEOBS20W LED840SPCWH.
S&F LED light fitting 1x10 watt bulk head LED type luminaries and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed.
S&F MCB single pole 240 volt 10 KA 5 to 40 Amp,"C"series conforming to relevant IS complete all as specified & directed.
S&F MCB SPN 240 Volt 10 KA 32 Amp , "C" series ,conforming to IS complete all as specified and directed.
Supply & fixing vibration free exhaust fan AC single phase 230/240V of size 300mm sweep double ball 900RPM with louvers making necessary fixing arrangements on wall with hold fasteners 4 Nos nut bolts connecting with three core flexible copper conductor cable (23/0.0060) from ceiling rose complete all as specified and directed.
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 m below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 20 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch all as shown in electrical plate No 3 of SSR Part-I 2009 including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia), with 40x40x6mm MS angle iron frame including necessary earth work and testing on completion, complete all as specified and as directed.
Supplying fixing jointing testing in replacement LT under armoured electric power cable 10 sqmm 2 core XLPE insulated, Screned PVC bedded galavanised steel strip or wire armoured conforming to IS 7098 (Part-I) 1985 ISI marked with aluminium multi stranded heavy duty 1100V laid in trenches / under floor, roads path or fixed on walls / on poles in heavy duty etc. as specified and directed of following size including lugs / thimbles / Glands including connecting testing & commissioning all bare conductor duly insulated 1.1 kv grade heat shrinkable sleeve at both ends complete all as directed by E-in-Charge.
M&L for sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed .
M&L for GI tubing light grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40mm dia complete all as specified and directed.
S&F electric water heater/Geyser vertical mount type 25 ltrs capacity five star rated shockproof and rust proof metal body compact size including tow nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified and directed.
M&L for Distribution board SPN 4 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection.Note:- DB and MCCB/MCB shall be of same make.
Dismantling and taking out/down carefully DI/CI pipe line 150 mm bore including all fittings and cleaning for re- fixing with spigot and socketed with tylon joints , complete all as specified and directed .
Re- laying of DI/CI pipe line 150 mm bore including all fittings with spigot and socketed with tylon joints , complete all as specified and directed .
S & F and testing DI/CI pipe 150 mm bore SS class "K7",ISI marked as per IS-8329 complete all as specified and directed. Make-TATA/ Electrosteel as approved.
M&L tylon rubber gasket joints for 150 mm boreDI/CI pipe ,complete all as specified.
S&F and testing 50 mm bore steel water tubing galvanised 'medium grade' ISI marked,with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches complete all as specified and directed. (Note:- Excavation and earth work shall be measured and paid separately under respective item of schedule )
M&L for construction of brick masonry valve pit of size1200mm x 1200mm x 1200mm (Internal dimension) with necessary excavation , returing filling in, PCC in foundation and flooring , plastering, coping, steel work for cover using MS sheet 3 mm thick welded/hinged MS angle iron 40x40x6mm forged flat iron hinges, sliding type lifting handle of MS bar 12 mm dia all as per shown in drawing No TD/EM/12 ,complete all as specified and directed.
Supply and fixing in replacement new CI sluice valve 150 mm bore ,both end flanged dully drilled for both ends with stainless steel spindle and nuts, stuffing box etc. Type PN-1.6, ISI marked complete all as specified.
M&L for cutting of iron pipe mains for insertion of tees,colars, sluice valves etc including de-watering work for pipe line upto 200 mm bore ,complete all as specified.
S& F in repair CI mechanical joint socket type with jointing materials such as rubber gasket, nut bolts & washers for cast iron pipe of 150 mm bore ,complete all as specified.
S& F CI/DI fitting for spigot & socket end pipe such as bends,(any type,angle and radius) upto 200 mm bore including dismantling/removing of old CI fittings ,complete all as specified.
S & F mild steel work in angle iron or other section including nut-bolts, washers,wire mesh etc , including cutting , screwing,bending,welding,drilling holes, etc.as in pit covers/tank covers etc including two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M/s Anil Kumar
ANANYA CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .