Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹9.1 L+₹48,890 (5.68%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹18,300
Closing Date
20 May 2020, 10:00 amClosed
Executive Engineer (Elect.)
Executive Engineer (Elect.), PAU, Ludhiana
Providing and Installation of 100 KVA Genset for Dr. DS Athwal International Scientists Centre at PAU, Ludhiana
2020_PAU_45626_1
Endst. No. 211-20 Dated- 04.03.2
Open Tender
Electrical Works
Multi-stage
122 days
PAU
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Yes
TIA
₹18,300
Yes
25 Jun 2020
5 Mar 2020
21 May 2020
5 Mar 2020
20 May 2020
5 Mar 2020
Amount
Supply and Erection of 3 Phase 100 KVA Silent Genset Remote start panel with battery charger with manual start & auto stop configuration to be, noise level should be less than 75 db within the 1Mtr. Range, Fuel tank suitable for 8 Hrs of operation, 1 no. Battery for starting purpose, base rail , loading unloading & installation, complete set with 2 Year comprehensive warranty in all respect as desired by Engineer -In -Charge at site Compliance with Indian Standards. Make: SUDHIR/JACKSON/KIRLOSKAR) Diesel Engine:- Diesel Engine should be 6 Cylinders,in line,4 stroke cycle,water cooled tubo charged after cooled, developing more than 150 BHP at 1500RPM. Alternator: Alternator suitable for continuous operation generating 100KVA at 1500 RPM ,415 Volts,0.8 Power Factor (lag) suitable for 50Hz,3 Phase,4 wire system.The Alternator should be brushless type screen protected,revolving field ,self excited,self regulated through an AVR. The alternator has the following features: ± 1.0%voltage regulation (max.) in static conditions. IP:23 protection with insulation class H. Permissible overload of 10% for one hours in 12 hoursof operation.
Foundation: Making of Reinforced cement concrete (1:2:4) foundation size (Approx 15'X5') as per size of genset and Approx 2' pathway around genset foundation complete in all respect as desired by Engineer -In -Charge at site.
RAVINDER KUMAR TAKKAR
RAVINDER KUMAR TAKKAR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .