Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.7 LAccepted-AOC H NO 107 A RAJENDRA NAGAR DIGARI KALAN JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹82.6 L+₹3.1 L (3.94%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹86.7 L+₹7.2 L (9.11%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹89.0 L+₹9.5 L (12.0%)Rejected-Finance OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | Rejected-Technical PLOT NO 28 B NAHAR SINGH JI KA HATTA BHATI CIRCLE RATANADA JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | - | Rejected-Technical Not Eligible bidder as being two class below of eligible class therefore not satisfies the eligibility criteria as per NIT. |
Tender Value
₹91 L
EMD Value
₹1.6 L
Closing Date
31 May 2024, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
SPECIAL REPAIR WORK FOR BLDG NO. 695 (BLOCK NO. V AND VI) ORS LIVING ACCN AND PROVN OF LIFT (06 PERSON) AT BLDG NO. P-1709 AT MIL STN JODHPUR UNDER GE (ARMY) NO. 01
2024_MES_641188_2
82324/106/E8
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (ARMY) NO. 01 JODHPUR
₹1.6 L
Yes
25 Jul 2024
6 May 2024
7 Jun 2024
6 May 2024
31 May 2024
14 May 2024
7 May 2024 - 13 May 2024
Amount
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) including removal of debris to out side MD land complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any description and in any position not otherwise specifically provided for including removal of debris to out side MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for 15 to 18 mm thick udaipur green stone slab, as in cooking plateform/ WHB counter top / treads of staircase (single piece), machine cut, (table rubbed and polished) best quality as per sample, including & over 10 mm thick screeding in CM1:4 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed.
All as per item No. 4.00 here-in-above, but as in verticle surfaces i.e. skirting/dado/riser of steps in single piece
M&L for 18 to 20 mm thick (telephone black shade) granite stone, as in WHB counter top, machine cut, (table rubbed and polished) best quality as per sample, over & including 15 mm thick screeding in CM1:4 including rounding & double mouldlng with jointless finish of the edges, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed.
M&L for 25 mm thick cement concrete 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregate), to receive floor finishes, complete all as specified & directed.
M&L for glazed colour ceramic tiles (premium quality) of size 250X450X6-7mm / 300X450X6-7 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including M&L 10mm thick backing coat in CM (1:3) complete all as specified and directed.
M&L Machine cut kota stone slab 18 to 20mm thick as in floor laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including M&L 20mm thick screed bed in CM 1:6, complete all as specified and as directed.
All as per item No. 9.00 here-in-above, but as in skirting / dado/ verticle surfaces (single piece for steps), over & including M&L 10 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles (premium quality) of size ( square, rectangular ) area of each tiles exc 0.11 sqm but n exc 0.18sqm & 6 to 7 mm thick, as in floors etc., (colour and pattern as approved by GE) set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
M&L for joint free coloured ceramic tiles (premium quality) of size ( square, rectangular ) area of each tiles exc 0.11 sqm but n exc 0.18sqm & 6 to 7 mm thick, as in floors etc., (colour and pattern as approved by GE) set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and as directed.
All as per item No. 12.00 here-in-above, but as in skirting / dado/ verticle surfaces (single piece for steps), over & including M&L 10 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Taking down cement plaster on stone masonry, RCC surfaces, dado surfaces etc complete including racking out joints, hacking for key scrubbing down with water, complete all as specified and directed.
M&L for 15 mm thick rendering in CM 1:6 on stone masonry or brick masonary or PCC block masonary surfaces or or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed. Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.
Rendering 10mm thick in cement mortar 1:4 on concrete ceiling surfaces / sunsheds / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed. Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed.
M&L keyed pointing in cement mortar (1:3) to squared rubble masonry regular coursed or un coursed complete all as specified & directed.
M&L for applying 2 mm thick wall care putty on wall surfaces including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper paint on wall surfaces as per manufacturer’s instruction, complete all as specified and directed. Note -i)- Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. ii)- Paint shall be in one or more colours/ shades all as approved by GE.
M&L for Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash on ceiling surfaces complete all as specified and as directed.
M&L for preparation of old decorated ceiling surfaces plastered or unplastered, by brooming down or steel wire brushing, scrapping down moulds, moss and efflorescent salts and trading oil & greasy spots, including cornices etc and applying two coats of white wash on ceiling, complete all as specified and directed.
M&L preparation of new/old plastered or un-plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement as primer, complete all as specified & directed
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area not exc 1.5 Sqm each, complete all as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. complete all as specified and directed. Note: (i)-M.S. hold fast/ lugs or SS dash fasteners shall be measured paid for separately. (ii)- + 5mm tolerance in dimension i.e. depth and width of profile (frames) shall be acceptable, variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L Pressed steel frames of size 105X60mm of 1.25mm thick for doors with one or more rebates including necessary fixing lugs. hinges, lock strike plate,etc., complete all as specified and as directed.
M&L Pressed steel frames of size 165X60mm of 1.25mm thick for doors with one or more rebates including necessary fixing lugs. hinges, lock strike plate,etc., complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in coping/ benching, DPC, pier caps, bed blocks, for hold fast etc., including mixing with WPC and necessary form work, complete all as specified and as directed. Note:- WPC shall be measured and paid separately.
Taking down steel windows and ventilators ( glazed / fly proof) of any description complete all as specified and as directed.
S&F factory made box type windows (steel) (BWM) with side hung shutter with cooler opening as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded, complete all as specified and as directed. Note : (i)-Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same. (ii)- Guard bar, Glass panes & wirecloth shall be measured and paid seperately.
All as per item No. 30.00 here-in-above, but without glazing bars
All as per item No. 30.00 here-in-above, but without cooler opening
All as per item No. 31.00 here-in-above, but without cooler opening
S&F of Box type steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete with glazing bars, complete all as specified and as directed.
All as per item No. 34.00 here-in-above, but without glazing bars
M&L for rolled mild steel sections like Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165, complete all as specified and as directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm, complete all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N / m2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fie retardant WPC to be laminated with PVC foil of minimum 14 micron thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, , complete all as specified and as directed. Note : Stainless steel butt hinges and necessary SS screws shall be measured & paid separately.
M&L factory Made flush shutters, 35 mm thick solid core with block board core constructionand plywood face panels, decorative sunmica on both sides as per IS 2202(part-I, 1999) . The stiles & rails shall be with out any joint and made with non- coniferous timber hard wood (Hillock/ Mirantee/ Bosum/ Benteak) with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process. The over all finished thickness of face panel shall not be less than 35mm while the thickness face veneer shall not be less than 0.6 mm complete all as specified and directed.
M&L 35mm thick factory made 2nd class HW glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I Section 8 Clause 8.24 (a) complete all as specified and as directed.
M&L pre powder coated coloured aluminum anodized door frame (minimum thickness of powder coating 50 micron) and shutters for door/windows, etc or as approved by GE including jointing cleats for fixing etc as per manufacturers instructions complete all as dire+2051:2061cted. Note : (i) Weight of all aluminum members shall be measured(ii) Hinges, handles etc shall be measured and paid separately. (iii) Glass pan and rubber beading shall be measured and paid separately. (iv) Fixing of shutters with fittings shall be as per manufacturers instructions.
S&F of stainless steel butt hinges 100mm size, include screws or bolts, nuts and washers to match the butt hinge, complete all as specified and as directed.
S&F of aluminium anodised, barrel tower bolt 200 mm long complete all as specified and directed.
S&F of aluminium alloy anodised sliding door bolt woth hasp and stalpe (bolt type and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long, complete all as specified and directed.
S&F in repairs of Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminum alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty & fixed, complete all as specified and directed.
S&F aluminum anodised handle extruded section of size 150mm long, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame incld punching or drilling out old glazing pins/ spring clips and provding and fixing new ones, complete all as specified and as directed.
S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed.
S&F for 4 mm thick figurred, pin headed glass ordinary quality & glazing with oil putty in square n exc 0.50sqm ineach pane, complete all as specified and as directed by Engr-in-Charge.
M&L for Preparation of new or old steel surfaces of any description over 10cm width or girth not otherwise described and apply two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed .
M&L for preparation of new/old or previously untreated wooden surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) complete all as specified and directed.
Taking up or down 15/20mm bore steel tubing/CPVC PIPE, fixed to wall/ceiling or laid in trenches/floor and connections including cleaning for refixing or credited to contractor complete all as specified and as directed.
Taking up or down 25mm bore steel tubing/CPVC PIPE, fixed to wall/ceiling or laid in trenches/floor and connections including cleaning for refixing or credited to contractor complete all as specified and as directed.
Supply, laying, testing & commissioning of 16 mm outer dia CPVC pipe,SDR-11, with all fitting (eblow, socket,tee with internal thread of brass) fixed to wall, ceiling or laid on floor, with CPVC solvent, complete all as specified and directed.
All as per item No. 78.00 here-in-above, but size 20/25 mm outer dia
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed.
S&F in replacement of bib cock with flange 15mm dia, chromium plated, cast copper alloy, fancy type, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in replacement CP fancy type brass wall mixer with telephonic shower arrangement ,connecting legs and wall flanges, including overhead shower, crutch and telephone shower complete all as specified and as directed.
S&F in repair Fancy type Chromium plated shower roses 125mm size with arm, with or without swivel joints, 15mm bore, including fixing to steel pipe or union.
S&F in replacement angular stop cock with wall flange, chromium plated, cast copper alloy fancy type, (ISI marked) 15mm dia complete all as specified and as directed.
S&F stop valves cast copper alloy (ISI marked) CP screwed down high pressure with crutch or butterfly handle screwed both ends for 20mm bore of iron pipe or union and fixed in repair complete all as directed.
S&F Pillar taps 15mm bore , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe .
M&L for 6 mm thick bevelled edges high quality looking mirror fancy type fixed to wall with chromium plated screw with cup washers etc complete all as specified and as directed
M&L for 75mm outlet diameter PVC nahani trap, with CP Mild steel grating (with or without hole) including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) using 20mm graded stone aggregate, complete all as specified and as directed.
S&F tubular towel rail 20mm dia brass chromium plated `D' type 60cm long with bracket and fixed complete all as directed .
S&F in repairs decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia with best quality knob metal with double fitting type including stainless steel brackets fixed to walls complete with two nos decorative stainless steel knobs at each end (As approved by Engr -in-charge).
M&L for 7.5cms thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, manehole cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:3 or cement mortar 1:4, complete all as specified and as directed.
S&F of Vitreous China wash basin size 450 x 300mm with padestal, white, flat back, including CP waste coupling, waste pipe, PVC Connection 300 mm long, brackets complete all as specified and directed.
S&F of Vitreous China wash basin size 450 x 300mm white, flat back, including CP waste coupling, waste pipe, PVC Connection 300 mm long, brackets complete all as specified and directed.
S&F in repair vitreous china squatting Pan, Orissa Pattern of size 580X440mm white with integral foot rests and cast iron `P' or `S' trap front or back fixed in repairs Including connection to trap etc and provision of cement concrete bedding and making good to floor, complete all as specified and as directed.
S&F in repair vitreous ware wash down water closet [Pedestal Pattern], white [ETWC] including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap connecting to drain pipe and flushing pipe etc.,& provision of cement concrete making good to as existing floor, complete all as specified and as directed.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 100/110mm bore, complete all as specified and as directed.
Dismantling of cast iron or AC drain pipe/ PVC pipe jointed in cement mortar of size 75mm bore, complete all as specified and as directed.
Supply & laying 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches of suitable size complete all as specified and as directed .
Supply & laying 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in wall/ceiling/floor of suitable size complete all as specified and as directed .
Supply & laying 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in wall/ceiling/floor of suitable size complete all as specified and as directed .
S&F 75 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and as directed.
S&F 110 mm bore (SWR) PVC bends any radius with oval access door complete all as specified and directed.
S&F of PVC (SWR) 110mm bore vent cowl complete all as specified and directed
S&F in replacement 10 ltrs capacity PVC valve less(Super special colors), (ISI Marked) syphonic action type, flushing cistern, low level, with Anti Bacterial Knob, with inlet, ball valve, float and handle including bracket, cistern colour shall be match WC colour, complete all as specified and as directed.
S & F in repair 32 mm bore low density polythene pipe (LDPE) of pressure rating 6 kgf / Sqcm for WHB and sink complete all as specified and directed.
S&F in replacement 15mm bore PVC connection for Flushing cistern 600 mm long best quality with PTMT nuts, complete all as specified and as directed.
M&L 40 mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in flooring/hard standing laid in alternative bays using glass dividing strips or over roof padding to obtain plain surfaces making good depression / undulation including finishing cement concrete surface even and smooth without using extra cement complete all as specified & as directed.
M&L for machine cut sand stone slabs, 5 cm thick, Jodhpur pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and directed.
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster, padding,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same to the places where as directed.
M&L for neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions over the RCC roof slab for laying of water proofing treatment including providing the following as roof treatment complete all as specified and as directed : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 20mm micron HMHDPE, outer film 20 micron each, thickness 1.50mm having weight not less than 2.25 Kg/Sqm using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen conforming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE : Blown type bitumen confirming to IS 702-1988 grade 85/25 @ 1.2 Kg / Sqm
M&L for plain cement concrete 1:2:4, type B-0 (using 12.50mm graded crushed stone aggregate), as in roof padding over roof for making good depression / undulation to make the existing as filling in depression of roof slab, complete all as specified & directed.
Disconnecting existing tanks setting aside [or lowering if required] for repair,cleaning etc., and hoisting if required reconnecting and refixing in position of water tanks of capacity exceeding 500 litres and not exceeding 1000 litres complete all as specified and as directed.
S&F Rotational moulded polythene water storage tanks of 1000 ltrs capacity, white three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I with PTMT ball valve heigh pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms complete all as specified and as directed.
Supply only integral water proofing compound (ISI marked).
Demolition of brick / block or stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed.
M&L precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in solid block masonry, 10cm width and setting in cement mortar 1:4complete all as specified and as directed .
M&L plain cement concrete (1:2:4) type B-1using 20mm graded crushed stone aggregate as in roof kerbs or mud steps, rounded or chamfered on edge, complete all as specified & directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate), as in sub base to floor, complete all as specified and directed.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Taking down carefully cement conc /spalled out concrete from RCC roof projections, cilinigs ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc., and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
S&F in replacement TMT bars 12 mm dia fixed by way of stitching ( welding ot tieing with existing reinf) incl drilling holes etc & securing ends in walls etc ,complete all as specified and as directed.
M&L for cleaning the existing reinf of slabs , chajjas etc & applying a coat of SIKA RUSTOFF 11 to remove the loose rust particles etc & throughly cleaning the surface.,complete all as specified and as directed.
M&L for applying a coat of bond coat made with cement slurry (1 part cement to 1.5 -2 parts water) mixed with admixture LATEX POWER mixed @5 Kg per 50 kg of cement & applying to the conc surfaces @ 200 gm/sqm to obtain tack.,complete all as specified and as directed.
M&L for 15 -20 mm thick rendering in CM (1:1:2) using1 part of cement 1 part 2-3 mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfaces with cement mixed with SIKA PLASTOCRETE SUPER admixture @ 100 gm /50kg of cement & finishing the surface even & rough to receive final rendering coat. ,complete all as specified and as directed.
M&L for 5 mm thick rendering in CM 1:3 & finishing the surface even & smooth w/o using extra cement ,complete all as specified and as directed.
S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc,complete all as specified and as directed.
S&F MS chromium plated peg set of five fixing with wall complete
M&L for Writing letters or figures (Black Roman, Italic or Indian n. exc 30cm high with thick paint complete all as specified
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil all as specified and directed.
Supply, laying, testing & commissioing of 150 mm bore reinforced cement concrete pipes, one end socketed, class NP2, laid in trenches and jointed complete all as specified and as directed .
Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate as in bed to150 mm bore drain pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed.
M&L for Removal of excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Removing of existing filling in sunken floor wc/bath/kitchen and repair to sunken floor with 15 mm thick plastering in CM 1:3 of internal surface with PC than painting with bitumen 30/40 over a coat of bitumen primer putting 50 micron polythene than filling with pcc 1:5:10 type E-1 using 40mm graded stone aggregate and inserting 50 mm bore GI water pipe light grade spout complete all as specified and directed.
S & F floor door stopper of alluminium alloy body and toungue anodised with hard drawn steel spring 150mm long complete all as specified and directed.
M&L for rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars ,barred iron doors; ladders ;framed balusters walk ways railings framed work of water tanks and similar work confirming to Fe-290Gde E-165 complete all as specified and as directed.
M &L in repairs for fabrication of pressed steel cupboard shutters, using 1.00 mm thick MS plain sheet & frame 1.25 MM thick, bent to shape, including applying two coats of synthetic enamel paint on tint surfaces over & including M&L for two coats of hammer tone finish on external surfaces alongwith locking arrangement mortice lock handle etc., including taking down old exisiting shutter, complete all specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition)as in Downward fascia , Roof projectios, sunshades suspended roof slabs railings etc., including removal of debris to out side MD land complete all as specified and directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.
M&L for RCC M-25 design mix as in beam, cantiliver, roof beam, plinth beam, lintel beam/band and the like complete all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide includingrough finished surfaces complete all as specified and directed.
M&L for RCC M-25 design mix as in slabs supported on walls, beams and colunms in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S & F HYSD TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S & F HYSD TMT bar 6 to 8 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
Exposing existing RCC members such as columns, slabs, lintels, beams, etc. up to the main reinforcement carefully by means of Chisel & hammer, hard wire brushes or any other mechanical means, so as to remove all loose concrete and cleaning the surface to remove all dust particles, etc. and make the surface ready for chemical treatment in bone dry condition.
M&L for 30 mm thick guniting in patches on to the required area on RCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc. of all sizes and shapes at any heights from existing ground floor and at any locations with cement and mortar 1:2 (1 cement : 2 sand) under 2 to 2.8 Kg/Cm2 pressure after removing the damaged loose spalt concrete as specified here in before and applying one coat of rust convertor/kp-100 equivalent grade over reinforcement wherever necessary providing and tying in position 25mmx25mmx12 gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc,loose spalt concrete portions by chipping, removal of dust over treated surface ready to receive grouts including 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc, complete operation all as directed removing the debris out side the MOD land in low lying areas and leveling as directed, complete all as directed by Engr-in-charge. Note (i) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and alloy to dry. To this surface apply chemistic polycrete admixture at the rate not less than 2% by weight of cement or as per manufacture’s instructions. (ii) When polymix coating is in tackey condition guniting is done with polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer’s instruction. Polycrete admixture shall be procured from Chemical Adhesive Pvt Ltd Co or their authorized dealer. (iii) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. (iv) Work shall be carried out up to first floor
M&L for laying 40-50 mm thick Machine cut sand stone slabs as in Plinth protections laid over 20 mm thick cement sand screed in CM1:4 over 50 mm thick PCC all as specified and directed incl filling the joints of sand stone slabs with neat cement mixed with pigment to match the shade of slabs, complete all as specified and as directed.
M&L for 3 mm thick Aluminium comosite panel (ACP comprising of painted aluminium sheets & PVC sheet sandwitch ) as per trade pattern in approved color pattern incl forming borders etc in small widths and necessary frame work complete all as specified
S&F 75mm thick Jodhpur type stone slab not exc 2m in length machine cut all face & along exposed edged size faced both sided as in manhole cover, complete all as specified and as directed.
Excavation over areas depth not exceeding 1.5m in deep and getting out in any type of soil complete all as specified and as directed.
Excavation over areas, depth exceeding 1.5m but not exceeding 3.0m in deep and getting out in any type of soil complete all as specified and as directed.
M&L cement concrete (1:5:10) type E2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
M&L forPre-cast cement concrete block masonry using PCC, 1:2:4, type B-1 solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6, straight or curved on plan exceeding 6 m mean radius including demolition of block walling complete all as specified and as directed.
S & F HYSD TMT bar 5mm to 10mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M&L for RCC M-25 design mix as in foundation including footings, foundations beams , bases for columns etc., and the like complete all as specified and directed.
M&L for RCC M-25 design mix aas in columns ,pillars etc., and the like complete all as specified and directed.
Use and waste of Formwork to sides of pillars columns of shape square or rectangular etc. also splays between floors and beams, etc. and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed.
M&L for brickork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM 1 : 6 complete all as directed
M&L 10mm thick rendering in cement mortar (1:3) on fair faces of brick/ concrete surfaces of walls ( incl mixing wpc) , finished even & smooth without using extra cement all as specified.(Note : wpc shall be measred and paid for seperately.
M&L for 15 mm thick rendering in CM 1:4 on stone masonry or or brick masonary or PCC block masonary or surface fair face or on one side of lathing finished surface fair and even without using extra cement, complete all as specified and as directed. Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.
Preparation of new/old external wall surfaces by Brooming down or steel wire brushing, scrapping down mass and efflorescent salts and trading oil & greasy spots, washing rubbing down and stopping distempered surfaces and M&L for applying two coat of exterior acrylic emulsion (apex or equivalent) of approved quality & tint on walls as spd and as directed Engineer-in Charge.
M&L prep of newly/Old plastered surfaces or surfaces from which existing treatment has been completely removed & applying two coats of birla /JK wall putty , sand papering the same & making good to depressions if any to obtain totally smooth surfaces all as directed
Preparation of old/New surfaces by Brooming down or steel wire brushing, scrapping down mass and efflorescent salts and trading oil & greasy spots, washing rubbing down and stopping distempered surfaces and M&L for applying two coats of oil bound distemper (of approved quality & tint) on walls as spd and as directed Engineer-in Charge.
M&L for 12-15 mm thick machine cut white marble stone fixed in flooring/skirting over 15mm screed bed in CM (1:6) including demolition of old stone etc complete incl making good & rounding of the edges complete.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
Taking down carefully UNSV submain wiring of any size and all as directed.
M & L for (concealed) point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed (including Cutting Chases and make good the distrubed surfaces ) conduit of size 20 mm or med grade as required as site, totally of concealed in walls / and surface of ceiling or fixed on surface of columns / beam / tie beam etc by means of saddles and clips etc incl all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc incl 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, all as specified, directed and shown on drgs for The rates of chase cutting on wall done concealed conduit and steel terminal boxes are included in the unit rates, suitable for One light/Fan/Exhaust Fan point controlled by one, one way switch all as specified and directed by Engr-in-Charge.
All as per srl item no. 148.00 here-in-before but suitable for One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
All as per srl item no. 148.00 here-in-before but suitable for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
All as per srl item no. 4 here-in-before but with 2.50 Sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for indpendent 15 Amp point.
S&F Switch piano type, single pole, ISI Marked, one way, 5/6 amps, 230 volts, complete all as specified and directed.
S&F Socket, two-in-one, 5 pin, 5 Amp, universal type, 230 volts, ISI Marked, complete all as specified and directed.
S&F Switch piano type, single pole, one way, 15/16 amps, 230 volts,ISI Marked, complete all as specified and directed.
S&F Socket, 6 pin, 5/16 Amp, multipurpose shutter type, 230 volts, ISI Marked, complete all as specified and directed.
S&F Lamp holder, metal cased, bakelite body, 230 volts, ISI Marked, complete all as specified and directed.
S&F LED lamp 9 W, ISI Marked, complete all as specified and directed by the Engineer-in-Charge.
S&F Ceiling rose, three terminals, bakelite body, 230 volts, ISI Marked, complete all as specified and directed.
S&F LED light fitting 1 X 20 watt (4 feet), T -5 batten fitting, Desinged linear sleek aesthetic PVC housing, PC cover ensures soft an glare free lighting wide angle of 120º, upto (110 Lm/W), complete all as specified and directed.
S&F bldg security LED Light Luminaire of 25 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length(or bracket as approved by GE) including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as directed.
Supply and Fixing LED miror light 8/10 watt, 360º rotation including taking down u/s fitting any type, complete all as specified and directed.
S&F of Heavy duty Exhaust fan 300 mm sweep, 900 RPM, including louvers complete and including taking downd of existing UNSV Exhaust fan Deposit to AGE EM store , complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades deposit to MES store and directed by Engr-in-charge.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor and Complete all as specified and directed by Engr-in-charge.
Supply and fixing as vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 6 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB incl dismantling of old UNSV DB all as specified and directed by the Engr-in-Charge.
S&F MCCB, A Frame, thermal adjustable magnecatic setting, Ics = 75% 16 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, , complete all as specified and directed.
S&F MCB single pole and neutral 240 volts any rating from 40 to 63 amps, with rupturing capacity 10 KA, 'B' curve type, with over load and short circuit protection, complete all as specified and directed.
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed.
Supply and fixing as MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall incl dismantling of old UNSV DB, complete all as specified and directed.
Supply and fixing as MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall incl dismantling of old UNSV DB, complete all as specified and directed.
M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
Earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) wih top edge of the plate not less than 1.5 metres below normal ground level, nnected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in elevtrical plate no. 5 connected to Earthing test point all as ecified or indicated including testing on completion( Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover & GI 15 mm dia protection pipe upto 7.5 mtr. lead etc. complete )
Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 50 Sqmm 3.5 core all as diredted by Engr - in - charge Note : Earth work and brick work measured and paid separately
Excvation in trenches not more than 1.5 meter wide and in depth in loose soil ll as directed by Engr in Charge
M & L for Retuerning and filling of excvated loose soil in treches aall as directed by Engr - in Charge
M & L Removal of surplus loose soil from excavated place and deposting at safe side distance not more than 50 meter from excavated place all as directed
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 300 mm x 180mm x 40mm complete laid over the cable perpendicular to the cable for protection, complete all as specified and as directed.
Supply and lay sand for sand cushioning for cable protection in trenches all as directed and specified in SSR Part - 1.Note:. for the purpose of payment punned thickness will be measured.
Supply and fix in replacement of GI tubing of size 40mm bore, light grade for protection of cables on poles / under road crossing complete all as specified and as directed.
M&L for sub main wiring with 2 run of 4.0 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 2.50 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 4.0 Sq.mm. and one run of 2.50 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
S&F electric storage water heater of capacity 25 litres BEE 5 star rated including proper installing arrangment on wall surface with suitable Anchor bolt fatser and Geyser connections for hot and cold water supply made of stainless steel wire braided connrtector with chrome finish heavy duty nuts of 15 mm size with suitable lengh etc complete all as directed by Engineer-in-Charge.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps
Supply and fixing of 25.00 mm bore GI Steel water tubing, medium grade, Galvanized with screwed and socket joints, with all fittings such as short lengths, tees, bends, unions, elbows, reducers etc concealed in wall or laid fixed in repairs in floors 15mm bore size complete all as specified and directed.
Supply and fixing of 20.00 mm bore GI Steel water tubing, medium grade, Galvanized with screwed and socket joints, with all fittings such as short lengths, tees, bends, unions, elbows, reducers etc concealed in wall or laid fixed in repairs in floors 15mm bore size complete all as specified and directed.
Supply and fixing of 20.00 mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
Supply, install testing & commissioning of 06 passengers lift, the lift shaft speed 1.0 to 1.5 mtr/sec with load capacity 408 kgs electricity operated PM gearless traction machine located above the shaft, the size of cabin car is 950 mm wide x 1100 mm deep x 2100 mm high / suitable to carry 06 (six) persons comfertabaly and clear entrance 800mm wide x 2000mm height, lift with single speed motor 415 volts, 3 phase, AC 50 HZ supply conforming to IS-14665, suitable to serve Ground floor and 02 upper floors (G+02), 3 stops, 03 openings with AC variable voltage & variable frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with / without attendant, centre opening doors with drive (electric motor driven mechanism, sliding stainless steel doors, automatic rescue device (ARD) system 3D infra red sensor in full height of door & built in voice announcing system without hand set in car, machine room & near ground floor with landing door complete all as specified and directed / gearless machine loaded in the shaft on the top of guiderails. Alongwith following accessories /components Make: / SCHINDLER /FUJITEC/ TKE (ELEVATOR TECHNOLOGY)
(a) :- CONTROLLER (LCB): Microprocessor based LSVF closed loop controller with VVVF drive unit for existing duty load, speed, stops and simplex full collective operation with incorporation of features like, Auto Rescue Device (ARD), energy efficiency, non fire lifts, enclosure meeting with the standards of EMC (Electo Magnetic Compatibility), Automatic by-pass, overload device, Automatic self levelling, Alarm bell / buzzer, Anti Nuisance, New reference system in hoist ways suitable for the new LSVF controller including magnets, cams and limit switches with mounting accessories and protection. Features included :- ACVVVF closed loop drive, alaram button in car operating panel with battery back-up, automatic operation for car fan, adjestable door open time, anti-nuisance (empty car), anti-nuisance (car call cancellstion at direction reversal), blower fan in car ventilation, braille on push buttons, car call cancellation by double pressing floor button in car operation panel, door open and door close buttons in car operating panel, door closing retries, door nudging, emergency light, full load by-pass, home landing, infra-red screen for car door, intercon, jammed landing operating panel call button by-pass, motor overheat protection, overload function with autio-visual indication in car operating panel, phase failure and phase reversal protection, automatic rescure device in case of power failure, attendant control,red dot matrix scrolling display in car operating panel, red dot matrix scrolling displayin landing operating panelon all floors, fireman control, fireman emergency return, CCTV Camera Cable.
(b) :- LIFT CAR CABIN : (i) Car frame / sling fabricated from suitable steel angle or channel section all as per IS. (ii) Car roof, provided with a car top rail / balustrade and suitable warning notice for fall hazard. (iii) Car cabin enclosures and false ceiling match with existing size, capacity with stainless steel (SS 304) hairline finish or / and stainless steel (SS 304) Scratch Resistant finish and flooring with granite / marble colour, texture, Design as approved by Engineer-in-Charge. (iv) Noiseless pressure fan or blower provided in lift cabin with supply grill matching with the interior of the cabin.
(v) Car size (inside): Not less than 1.45 sqm, 950 mm x 1100mm x 2100 high / suitable to carry 06 (six) persons comfertabaly and allowable tolerance as per IS 14665. (vi) Recess mounted LED lighting and in addition to normal lighting and emergency light unit using sealed Nickel / Cadmium Maintenance free battery power pack with charger and LED lamp to operate automatically and to illuminate the car for minimum 30 minutes in case of power failure. (vii) Hand rails fabricated with polished stainless steel at height & locations suitable for physically challenged passengers. (viii) SS mirror finish scratch resistant cabin enclosure at least one third of the size at middle portion on rear panel through out the height of the cabin. (c) :- CAR OPERATING PANEL: - Flush type Stainless Steel "Car Operating Panel" with the following devices. (i) Bank of call buttons corresponding to landing served LED touch/ feather touch control panel iluuminated buttons and tonal contrast to the COP & car panels finish with a soft audible signal to confirm operation. (ii) Alarm button, provided with a yellow pictogram to indicate the alarm button provision. (iii) Fan / Blower switch. (iv) Emergency calling phone
(v) Door open and close button. (vi) The main floor / exit floor push button, protruded 5 mm beyond the other floor buttons with illumination. (vii) "Up" & "Down" direction indicators indicating travel direction. (viii) Key operated switch for "Attendant" and "Automatic" operation. (ix) Overload panel along with audio / visual indication. (x) Door hold button, which extends normal door open period by up to 30 seconds. The extended time can be cancelled by actuation of door close button. (xi) Scrolling digital car position indicator with LED / LCD illumination indicating the landing at which the car is stopped or passing. (xii) Hall buttons combined with digital position indicator with SS hairline finish face plate suitable for simplex full collective operation at lobby floor of all landings (G+2 floor).
(d) CAR & LANDING DOORS: (i) The landing doors complete with headers, sills, frames etc. as required and entrances for lifts protected by automatic power operated, center opening, with finishing matching with car (stainless steel (SS 304) hairline finish or / and Stainless steel (SS 304) scratch Resistant finish), single skin construction all as per IS. (ii) Positive acting Door Drive powered by A.C. motor rigidly connected to the door and controlled by a VVVF unit and simultaneously open the car and landing doors and maintain the doors fully open or closed at each landing (G+2 floor), suitable for Attendant / Automatic operation and smooth opening of door without any jerk and closing of door without any banging noise, mounted on steel members forming part of the car sling. (iii) A multiple beam full height infrared electronic door detector, to regulate the closing motion of the doors for entry of the passengers.
(iv) Each landing door (PAX PRIMA), to be provided with an interlock, to prevent movement of the car away from the landing until the doors are locked in the closed position with an electric contact for the door to prevent car movement away from the landing unless the door is in fully closed position. (v) The car and the landing doors are to be provided with two point suspension sheave type hangers complete with tracks. Sheaves and rollers of steel with moulded nylon collar and shielded ball bearings and the tracks of suitable steel section with smooth surface. (e) DRIVING SHEAVES, GOVERNOR ROPES AND SUSPENSION ROPES: (i) Self lubricated, round standard wire ropes as per IS manufactured from high grade steel and special flexible material the combined breaking strength calculated with factor of safety. (ii) The end of the lift ropes, properly secured to the the car and counter weight hitch plates as the case may be with adjustable rope shackles having individual tapers babbit sockets and with a suitable shackle spring, seat washer, shackle nut & lock & shackle nut split pin or any other suitable arrangement.
Note: The Contractor shall to produce test certificate for each ropes as per IS. VOICE SYNTHESIZER: Digital type capable of site programming, giving a choice of background music (with option at the site to choose or reject) and capable of providing following messages in English language. "Arrival at the floor & its designation". (f) HOISTWAY HARNESS AND TRAVELLING CABLES: (i) Hoist way harness and travelling cables suitably suspended to relieve strains in individual conductors suitable for LSVF closed loop controller and fixtures, run from a junction box on the top of the car to a junction box located in the shaft bear mid point of travel and from these junction boxes conductors run to the various locations. (ii) Travelling cables shall be provided for signals, controls, lights, fans, alarm bell, emergency circuit and music. Extra 10 percent of the total capacity. (iii) Hoist way dimensions not less than 1820 mm wide x 1500 mm deep.
(g) PIT LADDER & SWITCHES: (i) Fixed pit ladders between the bottom landing and the pit floor, safe from all falling hazards. (ii) Two pit stop switches, with mushroom red head (it shall be locked off when pushed and reset manually) one at bottom landing level in the shaft & the other on the pit (First stop switch shall be accessible from the lower landing on opening of the landing door and the second switch from the pit floor) which when in the STOP position, shalll prevent any movement of the lift car including movement during inspection operation, until both the switches are set in the run POSITION. (iii) Terminal limit switches, to slow down and stop the car automatically at the terminal landings and final limit switches to automatically cut off power should the car travel beyond the terminal landings. (iv) Fireman switch at lobby floor. (e) Safety operated switch. (v) intercom. Note: (i) The contractor should visit the site to assess the exact scope of work prior to quoting the tender. (ii) The rate quoted shall be inclusive of the following:
(i) Fixing car and counter weight brackets, alignment of guide rails and fixing counter weight frame, car frame with balancing counter weights. Complete machine unit over speed governor (OSG), necessary machine fixing channels. (ii) Additional safety aspects for machine room (First Aid Box, Co2 / Foam based fire extinguisher cylinders, Danger plates, Rubber mats in front of each controller. Electric shock treatment charts and any other safety item that may be required by authorities) and in lift car including lift identification plates and DOS AND DONTS plates made of SS with engraved letters in English language as directed by Engineer-in-Charge. (iii) Two separate earthing with copper plate electrode 600mm x 600mm x ×3.15mm of lift as per SSR Part-I, Plate No. 03, 20x3mm copper Stripe earth strips running all along the hoist way and from machine room to earth pit including connecting from necessary terminals and suitable clamps complete. (iv) Painting of all lift metal work with one shop coat of rust inhibiting paint in the factory and painted with finishing coats on site. (v) Civil works like RCC foundation for fixing machines and PCC for fixing landing operating panel, Landing fascia, guide rails, sills limit switches, embedding in wall etc. complete.
(vi) The charges for obtaining Lift fitness certificate for a period of minimum five years from the Lift Inspector of the Rajsthan state. (vi) Any civil / architectural / structural damage or changes (if any) to walls / floors / architraves / fascades / ceilings / doors that the contractor may cause during work process will have to be rectified to its original form at his own cost, risk and responsibility. (vii) Electric Panel with Switch gear with RCCB and four pole MCB 25 Amps, four pole ELCB 25 Amps 300MA, Two pole ELCB 25 Amps 30 MA, SP MCB 6 to 16 Amps, control 12 way Double Door DB & 10 Sqmm copper cable for internal wiring, three 20 watt tube light fintting with switches at ground floor and machine room including control cable shall be provided. (viii) Buffers. (ix) Lift components / accessories incorporated in wall of Lift shall by provided by OEM along make /model/cat part No for further utilization during maint services.
Earthing complete with copper plate electrode 600 x 600 x ×3.15mm thick copper earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including 20×3 mm copper strip as earthing lead as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm, cast iron frame, funnel with wire mesh, including copper strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: (i) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (ii) GI strip above 7.5m will be measured and paid seperately. (iii) Earth resistance not exceeding 1.0 ohm.
Earth continuity conductor or main earthing lead fixed to wall on recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper Strip all as specified and directed.
Supply, laying testing in on walls /on pillars/ on ceiling LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 16 Sqmm 4.0 core all as diredted by Engr - in - charge Note : 1:- Earth work and brick work measured and paid separately. 2: - Where ever cable required to be laid on wall / ceiling / pillars , it shall be laid by means of saddles at on interval of not more than two feet in proper linear alignment and rates for same shall be deemed to be inclusive in the rates quoted by contractor
M/S KAUTILYA GARG
SNEH CORPORATION
Harsh Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .