Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Accepted amount | |
| 2 | L2₹48.9 L+₹91,888 (1.92%)Rejected-Finance MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Rejected other than L1 | |
| 3 | L3₹52.7 L+₹4.8 L (9.92%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Rejected other than L1 | |
| 4 | L4₹53.0 L+₹5.1 L (10.6%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L4 | Rejected-Finance Rejected other than L1 |
Tender Value
Refer Docs
EMD Value
₹99,900
Closing Date
16 Jul 2024, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Roorkee
REPAIR MAINT /REPLACEMENT OF SUBMERSIBLE VERTICAL TURBINE CENTRIFUGAL PUMP MOTORS AND ELECTRIC/ STARTER PANELS AND SWITCH GEARS OF WATER SUPPLY SWIMMING POOL AND SEWAGE SYSTEM INSTALLATIONS INCL REPAIR/MAINTENANCE OF DISING PLANTS INCL REPAIRS TO CI/
2024_MES_660269_1
8392/393/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Roorkee
As per tender documents
9 documents required · 9 mandatory
₹500
GE (MES) ROORKEE
₹99,900
Yes
3 Sept 2024
18 Jun 2024
18 Jul 2024
18 Jun 2024
16 Jul 2024
2 Jul 2024
Amount
M & L for assembling, installation, Lifting / lowering of deep well Vertical Turbine or Submersible pump set assembly of capacity 10,000-30,000 gallon per hour in existing bore well after carrying out necessary repair / replacement work including connecting column pipes, line shaft with guide spiders and rubber bushes etc. duly installation, commissioning and connected with hollow shaft electric motor or submersible of any capacity including making all necessary adjustments and electric connections as required for satisfactory performance of the pump complete all as specified and directed. Notes: (i) All type of T & P and transport is to be arranged by the contractor for lifting and lowering of the Pump sets. (ii) All electrical connection of the motor shall be removed and then connected very carefully with the help of suitable joint and insulation tape . (iii) Contractor shall carryout the repair forthwith after getting the massage from AGE E/M /JE E/M either verbal or telephonically. A sum of Rs 200.00 per day per pump shall be deducted from the contractor due payment on account of willfull delay on contractor part in the opinion of the Engr-in- charge. (iv) Spare parts will be measured and paid separatly in respective schedule as supply only item.
S&F in replacement the following spare parts of submersible pump set having discharge capacity 10000 to 30000 gallons per hour at 60 mtr head complete all as specified and as directed. :- Note (If any item not consumed during contract period the same has been taken on ladger charge through Receipt Voucher/Credit USR.
M & L for cutting of 150 / 125 / 100 mm bore column pipes in required length and rethreading upto 80 mm from end complete all as specified and directed.
Supply & Making column pipe with Mild steel cold ERW column pipe 100 mm bore, 10 feet long, 5.20 mm wall thick and threading upto 80 mm from end including supply & fix / welded 10 mm thick mild steel flanged both ends duly drilled for fixing 06 Nos nut bolts & washers and Supply & fixing nut bolt of size 75 long & 12mm dia with 02 nos washer and suitable size of rubber gasket, including welding of three Nos 150 mm long 40x6 mm flat iron pieces one side with flanged and other side with column pipe complete all as specified and directed
All as per item no 4.00 above but for 80mm dia
Supply & Fix / Lowering PVC insulated and PVC sheathed flexible, flat, nominal size 35 Sqmm 1100 volts grade, ISI Marked three core, stranded copper conductor cable complete all as specified and directed.
All as per item No- 6.00 above but of size 16 Sqmm
Taking out existing non clogging defective deep well vertical turbine pump set assembly / centrifugal pump set of any capacity from existing sewage sump well including dismantling and removal of blockage from pipe, Non return valve, foot valve, vertical turbine pump etc, including lowering of the same after proper assembling, testing and commissioning at sie complete all as specified and directed.
Supply only item :- Note ( If any item not consumed during contract period the same has been taken on ladger charge through Receipt Voucher/Credit USR complete all as specified and directed.
Ball bearing No. 6306 / 6311 make - SKF / NBC.
Ball bearing No. 6208 / 6210 make - SKF / NBC.
Gun metal bush of required size for pump.
Stainless steel shaft for pump as per existing at site.
Steel iron impeller of existing size
Steel iron sleeve for bearing housing and pump shaft.
Gland box / stuffing box complete with gland plate.
Gland plate struts of existing size with one nut.
Mild steel coupling of required size drilled with nut-bolts, rubber bushes and key for pump and motor.
S&F Rubber star coupling as per site requirement all as specified and directed.
M & L for cleaning of existing sewage sump of size 5 metre dia and Approx. 8.5 metre deep including taking out of all sludge, night soil, foreign materials found inside the sump after de-watering of sewage water, cleaning of all existing valves, sides & bottom of sump with wire brush & clear water and than pumping out balance water from the sump complete all as specified and directed.
M&L for disconnecting & dismantling of three phase, 415 volts, 50 Hz, 1460-1500 RPM electric motor of any make and model from pumps type like vertical turbine motor, non clogging vertical turbine sewage motor, centrifugal pump motor for water or sewage from installation, transporting the same to workshop, removing all burnt / worn out coils, cleaning of stator slots, insertion of insulating paper in the slots of appropriate size and rewinding with supper enameled copper wire ISI marked with existing size, applying two coats of insulating varnish including transporting back the same and re-installation of motor at site complete all as specified and directed for the following capacities: -
Capacity 50 HP.
Capacity 40 HP.
Capacity 30 / 35 HP.
Capacity 10 / 15 HP.
Capacity up to 7.5 HP.
M&L for rewinding of submersible motor 3 phase 30/40 HP capacity with PVC insulated copper conductor cable of appropriate size alongwith necessary packing and winding material with and including taking out burnt winding complete all as specified and directed.
All as per Sl item no 13.00 but for 15/20/25 HP capacity
Cleaning complete inside RCC/steel tank capacity of 1.00,000 gallons including removing deposit sand / stains from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution & wire brush and making surface free from any fungus, filling of cavaties inside of tank with CM 1:2 and applying one coat of white washing inside the tank dome complete including writing date of cleaning, for smooth functioning of rising main, washout, overflow up to satisfaction complete all as specified and directed.
All as per item No -15.00 but capacity 50,000 Gallons
Dismantling and disconnecting of electric motor any sizeor capacity de-assembling of all part and taking out unserviceable bearing and replaced the same with new bearing including reassembling the motor and fix back to its original position after testing and commissioning complete all as specified and directed :- Note :- Bearing will be measured and paid separatly in respective schedule as supply only
Supply only item :- Note (If any item not consumed during contract period the same has been taken on ladger charge through Receipt Voucher/Credit USR.
Ball bearing 6313 / 6314 of make – SKF / NBC.
Ball bearing 6311 / 6312 of make – SKF / NBC.
Ball bearing 6310 of make – SKF / NBC.
Ball bearing 6308 / 6309 of make – SKF / NBC.
M&L for Turning / cutting on lathe machine including transportation of existing bearing cover seat of motors of capacity up to 50 HP of any make/ model and fixing of cast iron sleeve of appropriate size of motor cover to make bearing including necessary transportation from site to workshop and back complete all as specified and directed.
M & L for re-metaling of motor rotor shaft by means of electric welding and turning to required size of bearing fixed in position suitable up to 50 HP motor of any make / model complete all as specified and directed.
Supply & Fix ratchet assembly suitable for 30 to 75 HP capacity electric motor complete all as specified and directed.
Disconnecting carefully old unserviceable Ammeter from panel board and Supply & Fix of new 96 mm size square digital type ammeter of range 0-100 Ampere with set of CTs of suitable rating complete all as specified and directed.
Disconnecting carefully old unserviceable Voltmeter from panel board and Supply & Fix of new 96 mm size square digital type Voltmeter of range 0-500 Volt complete all as specified and directed.
Supply only stable bleaching power grade I (ISI marked) in 25 kg polythene bag confirming to IS -1065(1989) of fresh stock with in 60 days of its packing complete all as specified and directed.
Supply only aluminium ferric white crystal clear packed in 25 kgs polythene bags complete all as specified and directed.
Supply only copper sulphate clean crystal clear packed in 25 kgs polythene bags complete all as specified and directed.
Supply only Hydreded lime packed in 30 kg polythene bags complete all as specified and directed.
Supply only casting soda packed in 50 kg polythene bags make KCI / ISI marked complete all as specified and directed.
Supply & Fix / lowering of Power driven Submersible pump set of capacity 15 HP suitable for 60 mtr head 1000 LPM, water cooling type complete with elctric motor of suitable size all as per manufacturer’s design including Supply & Making all fixing arrangement as per site requirement like NRV, reducer and flange of suitable size and making electrical connection with jointing material complete all as specified and directed. Make :-KSB item code BPD 273/08, or equivalent makes as approved by GE. Note:-The rate quoted in inclusive of removing unserviceable submerable pump set and depocit in E/M store yard.
Dismantling and taking up or down unserviceable / cracked steel tubing and fittings with all fittings including stop valves or gate valves of the following sizes including cleaning for re-fixing or transportation to MES store yard and depositing where directed complete all as specified and directed.
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, laying, jointing and testing GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches or wall/ceiling/floor as specified and as directed at site of the following sizes :- (Notes : (i) The laying and jointing of pipes are required to be carried out in short streches catering to specific requirements of a purticular quarter, building block or a group of blocks.)
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Re-laying, jointing old steel tubing after cleaning and connections in new or old position including supply & Fix new fittings such as bends, elbows, union, tees, reducers etc; as required at site laid in trenches or on floors complete all as specified and as directed of the following sizes :-
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Taking up DI/CI/MS pipe water mains (including all fittings), with spigot and socket ends and tyton joints/lead joints including burning out joints and recovering lead for the following sizes complete all as specified and directed.
100 mm bore
150 mm bore
Supply and lay in trenches in replacement of Ductile iron pipes K-7/K-9 Spigot and Socketed ends, centrifugally cast suitable for tyton joint in different lengths including rubber tyton joint complete as per site condition of following sizes all as specified and directed.
100mm bore
150mm bore K-7
150 mm bore K-9
Excavation in trenches not exc 1.5mtr wide and not exe 1.5 mtr in depth for laying GI pipe/ CI Pipe etc. and getting out in soft/loose soil complete all as specified and directed.
Returning fillingin soil from excavation including spreading, leveling, watering and well ramming in layers n.exe. 25 cm thick complete all as specified and directed.
Removing excavated (surplus soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M&L for repairing leakages of CI pipes with spigot and socket ends, de-watering of pipe lines and trenches, burning out joints to recover lead and making new lead joint with retrieved material and any additional quantity of lead required as per site requirement complete including all other materials such as spun yarn, fire wood etc and testing complete all as specified of the following sizes (Excavation and earth work shall be measured and paid seperately):-
80 mm bore
100mm bore
150mm bore
M&L cast iron special and fittings for cast iron up to 150mm dia such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing, or double socket etc).Tee pieces, single branch, Y junction, double branch, cross (all socket or socket and spigot) collars, caps, tail pieces, flange and plugs complete all as specified and directed
M & L for "D" joints complete with nut bolt & washers etc suitable for the following sizes of water mains complete all as specified and directed.
80mm bore
100mm bore
150mm bore
Labour only for cutting of cast iron water mains of following sizes carefully in repairs for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed.
80mm bore
100mm bore
150mm bore
M&L for drilling / boring and tapping on existing CI / DI /MS /GI pipe 80 mm to 300 mm dia size for branch connections of 15mm to 50mm dia by fixing of MS clamp of size 50x4mm cut to length and bent to shape, drilled and welded with GI socket of suitable size including rubber packing, nut, bolt & washr etc and testing complete all as specified and direted.
Taking out unserviceable sluice valve including S & F sluice valve, class PN-1.6, heavy duty, both ends flanged with gun metal spindle & check nut and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes (Note :- for these sluice valves which are fixed with pillar of over head tank work involve such as breaking of PCC/Lead flange joints will be deemed to include in the rate quoted & contractor will also repair the damaged floor etc,to match with existing. ( joints shall be measured & paid for seprately).
80 mm bore
100mm bore
150mm bore
Taking out unserviceable Non return valve supply and fixing connecting and testing non return valve horizental flow both and flanged class 'B' as PN 1.6 IS specification and conforming to IS -5312 including flange joints etc for the following sizes Make : Zoloto
80 mm bore
100mm bore
150mm bore
Supply & Fix gun metal gate/globe valve with iron wheel head screwed both end for iron pipe complete all as specified of the following sizes including dismantling the old unserviceable existing valve complete.
15mm bore
20 mm bore
25 mm bore
40mm bore
50 mm bore
M&L for construction of brick masonry valve chamber of internal size1.05x1.05x1.05 mtr with sub class 'B' bricks in CM (1:6) with 3mm thick MS Sheet cover and angle iron frame made out of 40x40x6mm with 2 Nos MS hinges welded to angle iron frame including lifting hook & locking arrangement duly painted with one coat of black bituminous paint over a coat of red oxide primer complete with necessary earth work, brick work, PCC bed, cement plastering, finishing including dismantling and removal of old unserviceble valve pit remains from site complete all as specified and directed.
Supply only Calcium hypochlorite 65-70% (Hight strength calcium based granual chlorination chemical) more stable thanchlorine gas and stronger than bleaching powder free from toxicity and safe for water. Test report of chemical must be drwn by Govt Lab) Note :- Contractor / Supplier must submit toxicity free from Govt. institute test report of calcium hypochloride alongwith each delivery. (Pakage in 45 Kg plastic drum)
Supply only TCCA 90 (Trichloroisacyanuric acid) granular chloine suitable for swimming pool water sanitation (treatment) each 50 Kg per drum complete all as specified and directed.
Supply and fixing Float / Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
15mm bore
20 mm bore
25 mm bore
M&L for cutting of grass, vegitation, bushes and tree branches running/ touching to ground by manually or machine and depositing where directed and cleaning the area in installation or along the pipe line complete all as specified and directed.
M&L for developing existing tube well using air compressure of 400 PSI and not less than 900 CFM and over pumping to give yield to make sand free water in 80 hours process and testing the yield for the first 40 hours by using air compressure including proper arrangement for back pressure at 4 stages of course sand/gravel/medium sand complete all as specified and directed. Note :- All types of T&P and transportation etc as required at site to complete the Job to be arranged by the contractor and cost/hire charges etc shall be deemed included in the quoted rates.
Complete overhauling ,repair and recommissioning of existing filtration units of the filtration plant of swimming pool of copacity 22000 gls /hrs including supply and filling of 15 to 20 %filter media of each stage for make up as well as replacement of US complete all as specified and directed constisting of following:- (a) Opening the man hole top cover of filtration dome , removal of existing exhausted filter media from the vessal , cleaning and scrubbing the internal surface of vessal to make the surface smooth, welding of damaged plates and painting two coates of water proof black bituminous paint on inner side of vessal complete all as specified and directed (b) Supply and filling 50% new filter media and filling after cleaning and washing remaining 50% in different layers as directed of under mentioned sizes:- (i) Pebbles size 6mm to 12 mm in mass thickness 100 mm complete all as specified and directed (ii) Gravels size 3mm to 6 mm in mass thickness 100 mm complete all as specified and directed (iii) Coarse sand size 1.2mm to 2.5mm in mass thickness 100 mm complete all as specified and directed (iv) Sand size 0.8mm to 1.2mm in mass thickness 990 mm complete all as specified and directed (c) Closing the man hole with cover for smooth functioning of filter plant complete all as specified and as directed. (d) Painting external surface of entire filter, booster pumping set and connected pipes, pipe line inside the swimming pool building with one coat of synthetic enammalled paint complete all as specified and directed .
Routine repairing/Maint of vertical turbine motor pump, submersable pump motor, centrifugal pump motor of water supply installation and non clog cetifugal sewage pump of sewage installationof any capacity for day to day mainetance and making it serviceable in all respect including necessary gland packing,nut bolt , gressing and minor leckage in pipe etc complete as directed. Note :- (a) Contractor / repersantive Machanic will report to Engr-in-charge/JE E/M (W/S) daily at for noon and after noon to collect routine/urgent work related to water supply like (gland leakage or any probleme in starter or in electrical panel or chlorine doging system or any probleme in rising mains etc) till completion of contract. The work shall be attended by the contractor immediately. The controctor will ensure availability of manpower equipped with all sort of petty items such as gland packing, nut bolt, gress etc required to accomplish the job. The controctor will also ensure as availability of every type of requisite T & P and Mobile phone to his trade man. iv) In case any maintenance / complaint informed to the contractor by means of telephonic or verbal or on complaint slip and not been rectified within 24 hours then the contractor shall be liable to pay the penality @ Rs 750 per day and the same penalty will be recovered from his RAR) Contractor or his representative will report to the concered JE E/M daily in the morning at 9.30 AM and in after Noon to collect the complaint and same will informed after rectification on same day.
Supply only following items for day to day maintenance :- (Item shall be taken on Ladger charge through RV/Credit USR )
Tee reducer GI 40 x 40 x 25 mm
Tee reducer GI 50 x 50 x 25 mm
Tee equal GI 25x25x20 mm
Tee reducer GI 20 x 20 x 15 mm
Tee equal GI 25x25x25 mm
Tee equal GI 20x20x20 mm
Tee equal GI 15x15x15 mm
Union GI 50 mm
Union GI 40 mm
Union GI 25 mm
Union GI 20 mm
Union GI 15 mm
GI Barel nipple 15 mm 6 inches long both end screwed
GI Barel nipple 15 mm 4 inches long. both end screwed
GI Barel nipple 20 mm 6 inches long. both end screwed
GI Barel nipple 20 mm 4 inches long both end screwed
GI Barel nipple 25 mm 4 inches long both end screwed
GI screwed Plug 15 mm
GI screwed Plug 20 mm
GI screwed Plug 25 mm
GI Elbow 15 mm
GI Elbow 20 mm
GI Elbow 25 mm
GI Elbow 40 mm
GI Elbow 50 mm
GI Socket 15 mm
GI Socket 20 mm
GI Socket 25 mm
GI Socket 40 mm
GI Socket 50 mm
Reducer Elbow GI 40 x 25 mm
Reducer Elbow GI 20 x 15 mm
Reducer Elbow GI 25 x 15 mm
Rubber inserting sheet of 3 mm thick up to 150 mm make – Jyoti or equivallent
Galvanized steel nut-bolts, washers of any size and shape or as per existing sample
Ball bearing grease in 1 Kg packing make – Castrol / Veedol / HP
Cotton waste
Gland packing in stranded sealed packing ISI marked upto 4,8,10 &12 mm size. Make Turner or equivalent
Chromium plated Bib Tab of size 15mm as per sample Make : Prayag/Parryware/Jainko
Chromium plated Angle cock of size 15mm as per sample Make : Prayag/Parryware/Jainko
Star Delta Starter Complete with Power Contactor's, Relay, Timer in Factory built Sheet Metal enclosure suitable for 50 HP Submersible / VT pump Motor.
Power contactor 3 pole of capacity 80 Amps, Ac 430 volt, 3 phase 50 Hz, MNX 80 series of L&T Make L&T cat pt no- CS97077 or equivalent in Legrand.
Power contactor 3 pole of capacity 50 Amp , AC 430 Volt 3 phase 50 Hz, MNX 50 series of L&T Make Cat Pt No CS97075 or equivalent in Legrand
Power contactor 3 pole of capacity 40 Amp , AC 430 Volt 3 phase 50 Hz, MNX 40 series of L&T Make Cat Pt No CS94190 or equivalent in Legrand
Power contactor 3 pole of capacity 32 Amp , AC 430 Volt 3 phase 50 Hz, MNX 32 series of L&T Make Cat Pt No CS94111 or equivalent in Legrand
Side mounting add on auxilaery block 01NO+01NC (Rght or left) suitable for of 3 pole L&T MNX series contactor AC 430 Volt 3 phase 50 Hz of L&T as per site requirement Make : L&T
S&F Single Phase perventer, phase reversible with under voltage, over voltage preventer relay - Make :Minilac / L&T
Supply Gramoxone and Roundup each one bottle chemical for grass dryer spray.
Day to day maintaince / repair / rectifiction of any type of water supply complaints like No water Supply or building mounted PVC OHT or any size and any type by digging along with the length upto 2 mter of water pipe line and in any type of soil upto the bottom of pipe to locate the exact pin point location of fault including rectification of fault with the help of plumber, returning filling of same by tightening and including replacing of GI union, elbows, sockets, tees, nipple, check nuts barrel nipple or cast iron special and fittings etc of any size and type by providing one plumber and his one helper on daily basis complete all as specified and directed Note: (i) Exacavation shall measured & paid separately under relevant items of this schedule. (ii) The items required to replace shall be measured & paid seperately under relaevant items of Schedule iii) Contractor is fully responsible to provide necessary, transportaion, T&P and safty equipment to his Plumber & helper to prevent any type of accidents and department will not responsible to provide any type of compensation to the contractor or his labour in case of any type of accidents / miss-happening or any type of casualty to his labour / plumber. iv) In case any maintenance / complaint informed to the contractor by means of telephonic or verbal or on complaint slip and not been rectified within 48 hours then contractor is penalised of Rs 500 per complaint per day and the same penalty will be recovered from his RAR. v) Contractor or his representative will report to the concered JE E/M daily in the morning at 9.30 AM and collect the complaint and same will deposite back to his office after rectification, duly obtaining the signature of concern user / occupant of affected accn or area on same day.
Cutting of road/dismantling of any interlocking paver blocks from pathways making good as per existing disturbed surface complete all as specified and directed.
S & F MCCB Three Pole 63 amps 415 volts rupturing capacity 25 KA, inculding taking out old and providing thimble for out going cable complete all as specified and directed.
All as per item no 58 but for 125 Amps.
Re-laying, jointing old CI/DI pipe dia 80/100/150 mm after cleaning and connections in new or old position including transportation, lead joint and laid in trenches or on floors complete all as specified and as directed. (excavation & earth work shall be measured and paid separetly)
M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string course lacing courses, parapets and railing upto 60cm in height copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as directed
S&F bib taps 20 mm bore, Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
M&L painting cast iron/MS water mains external surfaces with one coat of synthetic paint over existing painted surfaces of rising main supply for the following completed all as specified and directed.
150 mm bore
100 mm bore
80 mm bore
S&F 3-layer PP-R (Polypropylene random copo-lymer) concealed pipes SDR 7.4 (PN16) UV stabi-lized and antimi-crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded olypropylene including taking out and all fittings laid in trenches/wall/floors in following size.
20 mm dia bore
25 mm dia bore.
50 mm dia bore
75 mm dia bore
A ONE BUILDERS AND ENGINEERS
M/s badrinath Traders
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .