| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.3 LAdmitted-Finance PUNJABI MOHALLA KATRASGARH DHANBAD JHARKHAND 828113 | DHANBAD | DHANBAD | JHARKHAND | 828113 | L1 | Admitted-Finance | ||
| 2 | L2₹1.4 L+₹3,698.70 (2.75%)Admitted-Finance DEY VILLA MURLI NAGAR KOYLA NAGAR KOYLA NAGAR DHANBAD JHARKHAND 826005 | DHANBAD | JHARKHAND | 826005 | L2 | Admitted-Finance | ||
| 3 | Rejected-Technical 000 HIRAPUR DHANBAD A S GIRLS SCHOOL ROAD HIRAPUR DHANBAD JHARKHAND 826001 INDIA | DHANBAD | JHARKHAND | 826001 | - | Rejected-Technical OFFER NOT FOUND AS PER REQUIREMENT | ||
| 4 | Rejected-Technical 22 12 SIJUA DHANBAD 828121 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828121 | - | Rejected-Technical offer not found as per requirement of nit |
Tender Value
₹1.5 L
EMD Value
₹1,850
Closing Date
10 Sept 2026, 6:00 pmClosed
GM(EandM)I/C
Koyla Bhawan
Restoration of power supply to the entire B III and C III Blocks at Karmik Nagar affected due to heavy rainfall and strong winds as per scope of BOQ.
2026_BCCL_364994_1
BCCL/KB/ENM/PS/OT/26-27/21
Open Tender
Electrical and Maintenance Works
Percentage
5 days
Karmik Nagar
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,850
16 Oct 2026
7 Sept 2026
11 Sept 2026
7 Sept 2026
10 Sept 2026
7 Sept 2026
7 Sept 2026 - 9 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Work of restoration of power supply to the entire B III and C III Blocks at Karmik Nagar affected due to heavy rainfall and strong winds as per scope of BOQ. | - | - | - | - |
| 2 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. (600 mtrs. i.e. 250 Kg Approximately. | 250 | Kg | 25.16 | ₹6,290.28 |
| 3 | Dismantling of pole/ street light standard/ strut embedded in
cement concrete foundation etc. as required. | 3 | Each | 785.94 | ₹2,357.83 |
| 4 | Supplying and erection of 100 mm X 110 mm shackle insulator
with G. I. Bolt, nuts and straps etc. as required . | 15 | Sets | 140.9 | ₹2,113.54 |
| 5 | Supplying and erection of 100 mm X 65 mm pin insulator complete with G. I. Spindle and nuts etc. as required. | 15 | Sets | 59.47 | ₹892.08 |
| 6 | Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required. | 250 | Kg | 78.69 | ₹19,671.43 |
| 7 | Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. | 3 | Nos | 3,016.59 | ₹9,049.77 |
| 8 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. | - | - | - | - |
| 9 | Above 10.00 metre and upto 12.00 metre | 3 | Nos | 3,185.86 | ₹9,557.57 |
| 10 | Erection of cradle guard as required. | 50 | Nos | 42.55 | ₹2,127.26 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.52 MB
BOQ_377915.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .