Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 163 SWARN JAYANTI PURAM GHAZIABAD GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹14.4 L
Closing Date
11 Mar 2020, 1:00 pmClosed
SE CANDP 2
SE CANDP2 DEHRADUN
Supply Erection and Testing and Commissioning of 80 MVA 132 33 KV Transformer at 132 KV S s Manglore
2020_PTCU4_22769_1
PTCUL/CandP-II/SS-05/2019-20
Open Tender
Electrical Works
300 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,600
MD PTCUL
₹14.4 L
8 Jun 2020
18 Feb 2020
12 Mar 2020
18 Feb 2020
11 Mar 2020
18 Feb 2020
Amount
Part-A (Supply)
80 MVA Transformer 132/33 KV
145 KV CT 400/200/1, 5 Core, (1 ph.) 0.2s Acc. Class with J.B.
36 KV SF-6 Circuit Breaker (1600 Amp Complete with Structure)
33 KV Isolator without Earth switch 1600 Amp. Capacity (Mettalic & Insulator)
36 KV CT 1600/800/1 Amp. (1 ph.) 0.2s Acc. Class with J.B.
P.V.C. Control Cable 2.5 mm2, 2 Core
P.V.C. Control Cable 2.5 mm2, 4 Core
P.V.C. Control Cable 2.5 mm2, 6 Core
P.V.C. Control Cable 2.5 mm2, 10 Core
HT & LT Bushing Connector for Twin Zebra Conductor for 1600 Amp.
4- Hole Pad Connector Twin Zebra Conductor 1600 Amp.
T Connector Twin Zebra to Single Zebra Conductor 1600 Amp.
CT Clamp for Twin Zebra Conductor 1600 Amp.
Description of Work / Item(s)
Amount
Part-B (Erection )
Dismantling of 40 MVA T/F 132/33 KV( Radiator, Conservator, All Bushings Packing in Wooden Box, Marshelling Box, all accessories etc.)
Dragging & Shifting of 40 MVA T/F from plinth to safe place in S/s (App. 100 Mtr.) with Proper Safety
Dragging & Shifting of 80 MVA T/F from store to T/F Plinth (App. 100 Mtr.) with Proper Safety
Erection of 80 MVA T/F including Centrifuging, Cable connection, feruling, complete work, Earthing, Testing & commissioning complete
Dismantaling of 145 KV Old CT from the structure
Dismantaling of 36 KV Old VCB with structure
Dismantaling of 36 KV Old CT from the structure
Dismantaling of 36 KV Old Isolator from the structure
Erection of 145 KV CT 400/200/1, 5 Core, (1 ph.) 0.2s Acc. Class with J.B.
Erection of 36 KV SF-6 Circuit Breaker (1600 Amp Complete with Structure)
Erection of 33 KV Isolator without Earth switch 1600 Amp. Capacity (Mettalic & Insulator)
Erection of 36 KV CT 1600/800/1 Amp. (1 ph.) 0.2s Acc. Class with J.B.
Laying of P.V.C. Control Cable 2.5 mm2, 2 Core
Laying of P.V.C. Control Cable 2.5 mm2, 4 Core
Laying of P.V.C. Control Cable 2.5 mm2, 6 Core
Laying of P.V.C. Control Cable 2.5 mm2, 10 Core
Work of Testing & Commission of 132 & 33 KV Bays including all concern testing of New Transformer.
Work of Excavation of Earth for making pit for foundation of Equipments.
Work of CC 1:1.5:3 for making foundation of Equipment including all shattering work.
Description of Work / Item(s)
Amount
Total Part-A (Supply ) from BoQ1 sheet WITHOUT GST
Total Part-B (Erection ) from BoQ2 sheet WITHOUT GST
Add GST* Amount on (Total of Part-A + Total of Part-B above)
Padmavati Infrastructure Company
Modern Transformers Pvt. Ltd.
Modern Transformers Pvt. Ltd.
Padmavati Infrastructure Company
Modern Transformers Pvt. Ltd.
Padmavati Infrastructure Company
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid