Amount
Dismantling plain corrugated steel sheeting of any gauge/thickness including Nainital and similar pattern all as specified and directed.
Dismantling of wall and ceiling board of any thickness including cover fillets all as specified and directed.
Dismantling of frame work of timber in scantling 40 sqcm and over in section in any position all as specified and directed.
Dismantling of frame work of timber scantling in fillets, rails, posts, rafters, purlins under 40 sqcm in section all as specified and directed.
Taking down chowkat with shutters (without taking off shutter from the frame) area exc 1.5 sqm but nexc 4 sqm each all as specified and directed.
Taking down door/window shutter/cupboard shutter with frame (without taking off the shutters from the frame) area up to1.5 sqm each all as specified and directed.
Demolition of cement concrete in ground floor and paving nexc 15 cm thick (below or above ground level) all as specifed and directed.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for all as specified and directed
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises all as specified and directed.
Demolition of concrete block walling, stone masonary built in cement mortar including all quoins arches pillars etc and pre-cast block walling all as specifed and directed.
Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store all as specifed and directed.
Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store all as specifed and directed.
Dismantling water tank and removing to store capacity exc 250 but nexc 500 litres all as specifed and directed.
Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for all as specified and directed..
Dismantling of 150 mm dia CI pipes jointed in cement mortar and taking out of trenches if required all as specified and directed.
M&L PCC 1:4:8 type D 2 , (using 40mm graded crushed stone aggregate) in foundation all as specified and directed.
S&F ERW or Induction butt weld M.S. tube black conforming to IS 1161-1979 grade Yst 240 including fabrication and erection and fixed in position all as specified and directed.
S&F rolled mild steel section in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W (Gde E-250,quality- A) all as specified and directed.
S&F 11 to 15 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and nexc 15cm long all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specifed and directed.
M&L RCC M-25 grade design mix ( using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-rammed piles and mass concrete all as specified and directed.
M&L RCC M-25 grade design mix (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m clear span all as specified and directed.
M&L RCC M-25 grade design mix (using 20 mm graded crushed stone aggregate) as in chajjas all as specified and directed.
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter, finshed flat for rough finished surfaces of concrete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, finshed flat frough finisor fair finished surfaces all as specified and directed.
M&L formwork to chullah hoods, chajjas, troughs and similar items including edges, finshed flat fair finished surfaces of concrete all as specified and directed.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
All as per Item No. 28 here-in-before but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed.
M&L precast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in solid building blocks, exc. 10 cm in width and setting in CM (1:6) all as specified and directed.
M&L precast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in solid building blocks 10 cm thick and setting in CM (1:4) all as specified and directed.
M&L for providing precast cement concrete type 1:2:4 type B-1, ( using 20 mm graded crushed stone aggregate) as in landing, cover slab (for manholes) chullah hoods, chajjas, water trough mangers, shelves, and similar articles with plain faces and set in cement mortar 1:4 all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channel and drain all as specified and directed.
Extra for forming fair finished drain and channel 30 cm inner grith in cement concrete finished even and smooth using extra cement in forms mould mitred/stopped ends all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished surfaces even and smooth without using extra cement in internal surfaces of walls all as specified and directed.
M&L rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in CM (1:6) finished surfaces even and smooth without using extra cement in external surfaces of walls all as specified and directed.
M&L preparation of newly plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of 3 mm thick wall care putty all as specified and directed.
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of suitable primer all as specified and directed.
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) of 25 mm thick as in leveling course ,finished surfaces even and rough to receive floor finish all as specifed and as directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 but nexc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles laid over a screed bed of 15 mm thick in CM 1:6 all as specified and directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting over and including 10mm thick rendering in CM 1:4 as in backing coat of tiles all as specifed and directed.
M&L non skid ceramic coloured tiles 300x300x7 mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15 mm thick cement mortar 1:6 all as specifed and directed.
M&L glazed ceramic coloured tiles size 350x 250x 7 mm/ 450X 350X 7mm thick thick laid over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specifed and directed.
M&L prepolished chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed in neet cement slurry in floor with grey cement and pigment and including laid over screed bed or bedding layer of mortar 20 mm thick laying floor finished in cement mortor 1:6 all as specified and directed.
S&F frame work only for suspended false ceiling, GI exposed ceiling suspension system of grid size 600mm x 600mm with main runner 38mmx24mm, cross tee 29mmx24mm and wall angle 24mmx24mm. to form a grid of GI system duly suspended with 4mm dia GI/MS bar hanger fixing with steel dash fastner or iron purlins from the roof with adjustment clip providing in position for light fixture all as specified and directed.
S&F false ceiling of everest designer boards of size 595 mm x 595 mm x 4 mm thick fixed on GI snap grid all as specified and directed.
M&L PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) as in plinth protection, 75 mm thick finished surfaces even and smooth without using extra cement all as specified and directed.
S&F pressed steel frames for doors with one or more rebates (size of frame 125x60mm) including necessary fixing lugs, hinges, lock strike plate, etc., all as specified and directed.
S&F pressed steel frames for doors with one or more rebates (size of frame 105x60mm) including necessary fixing lugs, hinges, lock strike plate all as specified and directed.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F 35mm thick IInd class hard wood glazed and skelton door shutter divided into square, open rebated and prepared to receive glass/gauge etc (without sash barsi) edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass/gauge etc sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.20 (a) all as specified and directed.
S&F solid PVC door frame of size 50 mmx47 mm made out of 5 mm plain colour PVC sheet re-inforced with M.S square tube, suppyling and fixing in opening as per specification and drg all as specified and directed..
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for styles and plain colour of PVC sheet for top rail lock rail and bottom rail, on either side & gap insert for top rail bottom rail panelling of plain colour PVC sheets to be fitted in MS frame welded/ sealed to the styles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppying and fixing in the frame at site as per specification & drawing all as specified and directed.
S&F powder coated aluminum section for making frame and shutters of doors, windows, partition wall, shutters etc including styles & rails with standard anodized aluminum section, with one or more rebates including aluminium snap beading all as specified and directed (Glazing, rubber beading,hinges etc shall be measured and paid separately)
S&F Aluminium anodised DG 102 "DECO" grill of size 100mm x 10mm x7mm thick, approved design for windows/ventilators with and including F/U channel all as specified and directed.
M&L rubber beading for fixing glass panes in aluminium frame work all as specified and directed.
S&F 4.8mm thick sheet glass ordinary quality and glazing fixed to aluminium shutters in square nexc 0.5sqm in each pane all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specifed and directed.
S&F 0.56 mm nominal dia wire galvanised mild steel wire cloth and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple all as specifed and directed.
S&F butt hinges stainless steel 100mm size all as specifed and directed.
S&F butt hinges medium weight cold rolled mild steel 100mm all as specifed and directed.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
S&F 150 mm long anodised extruded aluminium alloy handles, fabricated type all as specified and directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F in repair floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size) all as specified and directed.
S&F in repair 20 mm dia chromium plated pipes for curtain rods all as specified and directed.
S&F in repair chromium plated brackets and knobs for curtain rods all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint on roof over a coat of red oxide primer all as specified and directed.
M&L for preparation of old painted steel surfaces by complete removal of existing treatment of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint on roof over a coat of red oxide primer all as per specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specifed and directed.
S&F 15mm bore GI tubing medium grade with all fittings fixed to wall and ceiling or laid in floor all as specifed and directed.
S&F 20mm bore GI tubing medium grade with all fittings fixed to wall and ceiling or laid in floor all as specifed and directed.
S&F in repair vitreous china squatting pan 'Orissa' pattern of size 580x440mm with white integral footrest (excluding flushing cistern and flush pipe including making good the disturbed surfaces) all as specifed and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt, flushing cistern and flush pipe) including making good the disturbed surfaces all as specifed and directed.
S&F in repair plastic water closet seat, black and white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device all as specifed and directed.
S&F 15mm dia CP jet with CP flexible pipe 90cm long including necessary fittings all as specified and directed .
S&F for 15mm bore Health faucet with CP felxible pipe of 90cm long incl necessary fittings complete all as specified and directed .
S&F in repair vitreous china wash hand basin (550X400mm) white, flat back excluding taps, waste chain and plug and porcelain stopper but including brackets all as specifed and directed.
S&F in repair 32mm bore waste fittings brass chromium plated for glazed ware sinks basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and othter end fixed all as specifed and directed.
S&F in repair 10 litres capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float, flush pipe and handle including brackets and fixed all as specifed and directed.
S&F in repairs PVC connection 15mm dia and 600mm long all as specifed and directed.
S&F in repair PVC waste pipe 32mm dia all as specifed and directed.
S&F in repair 15 mm dia bib tap CP fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrules all as specifed and directed.
S&F in repairs 15mm bore chromium plated brass angle cock screwed for iron pipe or union and fixed all as specifed and directed.
S&F in repair 15mm bore chromium plated brass, fancy type 2-in-1 angle cock screwed for iron pipe or union all as specifed and directed.
S&F in repair 15mm bore brass chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall all as specifed and directed.
S&F in repair 15mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to wall all as specifed and directed.
S&F rotational moulded polyethylene water storage tanks of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia HD polyethene float (ball) and epoxy coated aluminium rod (fly nut) screwed for iron pipe or brass ferrule all as specifed and directed.
S&F in repair CP towel rail with hook 600mm long all as specifed and directed.
M&L PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to 150 mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested all as specified and directed.
M&L 150 mm dia CI pipe (sand cast) soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floor all as specifed and directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor all as specifed and directed.
M&L 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed.
Cutting into existing manholes for 110 mm dia pipes, connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required all as specified and directed.
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc removing materials from site and keeping in safe custudy for taking as sch of credit (credit for above items should be made as per conditions separately) and depositing to MES store yard and making good to the disturbed surface of walls, floors roof etc all as specified and directed.
Dismantling unserviceable old existing submain wiring of any size all as specified and directed.
Dismantling unserviceable old existing XLPE/ Service cable of any size all as specified and directed
Dismantling unserviceable distribution boards all as specified and directed.
Excavation in trenches nexc 1.5 m wide and not exc 1.5metre in depth for foundationfor laying under ground cables in hard/dense soil and getting out all as specified and directed.
M&L sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and punning to proper required cover all as specified and directed.
Supply and laying old size sub-class ’B’ bricks laid flat length equal to width of bricks, perpendicular to UG cable laid over the dry sand cushioning for cable protection all as specified and directed. .
Returning, filling in, including spreading, leveling, watering and well ramming in layers nexc 25cm in soft loose soil all as specified and directed.
Removal of surplus soil to a distance nexc 50 metre and depositing where directed at a level nexc 1.5metre above the starting point all as specified and directed.
M&L in repairs of 32 mm dia steel tubes light grade galvanised with fittings, laid in trenches/wall/pole for protection of underground cable when crossing the road/fixing all as specified and directed. MAKE: JINDAL/ PRAKASH/SURYA)
Supply and lay in trenches, fixed to wall/pole UG cable XLPE insulated screened PVC bedded galvanised steel strip or wire armed heavy duty electric cable with multi stranded Aluminium conductor, 1100V grade of size 10 sqmm 4 core all as specified and directed.
M&L point wiring in PVC conduit or conceled in some places as per required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade complete with all fittings such as elbow, bends, junction boxes, saddles including MS sunken box 2.0 mm thick board (ISI Marked) including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches socket/regulator etc including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for One light/fan/bell point controlled by one ,one way switch with cable 1.5 sqmm size.
All as per item No 108 above but one socket outlet 3 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 108 above but One socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 108 above but for socket out let, 15/16 Amps on independent board with 4 sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dully all as specified and directed.
M&L sub main wiring in PVC conduit/conceled of required size 2x4 sqmm PVC insulated multistrand copper conductor with 01x2.5 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Make : Havells/Plaza/ Polycab Note:- For the purpose of payment two runs of 4sqmm conductors and one run of 2.5 sqmm conductor with conduit will be measured as one length.
M&L sub main wiring in PVC conduit/conceled of required size 2 x 2.5 sqmm PVC insulated multistrand copper conductor with 01x1.5 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Make : Havells/Plaza/ Polycab Note:- For the purpose of payment two runs of 2.5 Sqmm conductors and one run of 1.5 sqmm conductor with conduit will be measured as one length.
M&L switch socket combination 5A/16A, 5 in 1 flush type with fuse and neon indicator all as specified and directed. Make -Havells /Anchor / Legrand / HPL.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F switch socket combination 5 pin 5/6 Amps all as specified and directed. Make : Havells/Anchor/legrand
M&L ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and directed. Make : Havells/Anchor/legrand
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. Make : Havells/Anchor/legrand
S&F 9/10 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make -Surya/philips, CG,Havells, syska.
S&F surface and wall mounted LED tube light fitting with polycarbonate housing & interated electronic driver with tube rod of 18 watt. slim elegant design.and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make, Havells, CG, Philips, Bajaj.
S&F in replacement building security light fitting complete with 35 watt LED type IP 66 pressure die cast aluminium housing and heat resistant toughened glass with flame protection and better optics for uniform distribution etc complete with fixed bracket made out by GI pipe light grade of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make : Havells/Philips/Bajaj
S&F surface and wall mounted LED tube light fitting mirror type with high out put diffuser 2 feet ,10 watt 220 volt AC decorative type with driver holder and LED lamp/rod including connecting up with three core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make: Havells, CG, Philips, Bajaj.
S&F in repairs MCB DB box 20 Amps 240 volt, 20 A, MCB with top suitable for geyser with blanking plate all as specified and directed. Make Havells/Legrand/HPL/Anchor
Taking down serviceable Electric storage water geyser 25 litres capacity and refixing same location electric storage water heater of capacity 25 litres of five star rating, AC 230 volts with PVC connection pipe 15 mm dia heavy duty approx length 450/600mm long -02 Nos, Hole fastener nut & bolts made of iron approx length 6 cm long -04 Nos after complete work of building all as specified and directed.
S&F in repairs MCB DB SPN, 8 way 240 volt, double door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/ single pole with blanking plate all as specified and directed Make: Havells /Legrand/HPL/ABB
All as per item No 125 above but MCB DB SPN,12 way 240 volt with blanking plate all as specified and directed. Make: Havells /Legrand/HPL/ABB
Supply and fixing in repairs MCB single pole with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistance moulding suitable for single phase circuit of 6 to 40 Amps as specified and directed. Make: Havells /Legrand/HPL/ABB
All as per item No 127 above but MCB DP 40 Amps. Make: Havells /Legrand/HPL/ABB
All as per item No 127 above but MCB TP 100 Amps. Make: Havells /Legrand/HPL/ABB
M&L in replacement of earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2020 and as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
S&F exhaust fan AC single phase 230/240v, 50 HZ of size 300 mm sweep 900 RPM MS body heavy duty operating with louvers shutter complete grouting the ragged bolt in wall fixing the frame and exhaust fan fix including louver shutter with frame on the exhaust side and connecting with PVC insulator 3 core 23/0.0076 copper wire rubber insulated from ceiling rose to exhaust fan motor all as specified and directed. Make: Havells/Legrand /CG/Bajaj/Anchor
M/S BHAWANI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .