Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 64 INDUSTRIAL ESTATE PERUNGUDI CHENNAI TAMIL NADU 600096 | CHENNAI | TAMIL NADU | 600096 | Admitted-Finance |
| 3 | Admitted-Finance 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | Admitted-Finance |
| 4 | Rejected-Technical 434 ALAGAPURAM POST PERUMAL MALAI ADIVARAM SALEM 636004 | SALEM | SALEM | TAMIL NADU | 636004 | Rejected-Technical offer is technically not acceptable |
| 5 | Rejected-Technical | Rejected-Technical offer is technically not acceptable |
Tender Value
Refer Docs
EMD Value
₹55,000
Closing Date
3 Sept 2020, 2:00 pmClosed
SURYA GAYATHRI M A
MATERIALS DEPARTMENT PD ADMINISTRATIVE BUILDING UDYOGMANDAL P O KOCHI PIN 683501
PROCUREMENT OF RMU PANELS
2020_FACT_575604_1
MM/175/E21895
Open Tender
Miscellaneous Goods
Supply
COCHIN DIVISION, AMBALAMEDU
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹55,000
Yes
17 Feb 2021
11 Aug 2020
4 Sept 2020
11 Aug 2020
3 Sept 2020
11 Aug 2020
SF 6 INSULATED RING MAIN UNIT WITH FOLLOWING SPECIFICATONS: Rated voltage : 12 kV Operating voltage : 11 kV Type : Indoor, SF 6 insulated 3 way Power frequency (Hz) : 50 Standards applicable : IEC 62271-100, 62271-102 and 103,62271-200, 60056,60185 and 60186 Rated current of breaker and LBS : 630 Amps Rated lightning withstand voltage : 95 kVp Rated power frequency withstand voltage : 38 kV for 1 minute Rated peak current : 52.5 kAp Rated short time current : 21 kA for 3 sec SF 6 filling pressure : 0.4 bar No: of compartments : 3 ( one VCB+ 2 LBS) Busbar rating : 630 Amps (EC grade copper) Power cable compartments size : Suitable for 1 x 3 x 300 sq mm LBS pad lock positions requirement : Main and in Earth positions Main tank : IP 67 (3 mm thick- robotically welded SS tank) Type test report from National accredited agencies : Required Breaker spring charging operation : Motorized Capacitive voltage indicator : Required Protective relays required : Self-powered O/C and E/F protection CT specification- Ratio: 50/1, VA: 2.5, Class: 5P10 Battery and its charger are suitable for breaker and relay operations. 3 position mimic diagram with indicator required in front panel. Electrical and mechanical actuators required in VCB panel. Positive mechanical inter locks and gas pressure indicators are also required. Panel auxiliary supply 230V AC Note: PDI required for physical and performance evaluation.
IMPERIAL ENGINEERING COMPANY
ESWARI ELECTRICALS PVT LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .