Executive Engineer, Panchayat (R&B) Division, Mahisagar
Construction Of Library At Kharol Gram Panchayat At Post Kharol Ta. Lunavada , Dist. Mahisagar
368630
17 of 2026-27
Open
Civil - All
Works
Mahisagar
8 documents required · 8 mandatory
₹900
Executive Engineer, Panchayat (R&B) Division, Mahisagar
₹13,000
24 Nov 2026
24 Nov 2026
24 Nov 2026
2 Dec 2026
24 Nov 2026
120 days
Name Of Work :- Construction Of Library At Kharol Gram Panchayat At Post Kharol Ta. Lunavada , Dist. Mahisagar
Taluka :Lunavada District : Mahisagar
1 Construction Of Library At Kharol Gram Panchayat At Post Kharol Ta. Lunavada
Bill of Quantities
Item of work Quantities Rate in Amount
Estimated Unit Figures in
1 Excavation for foundation upto 1.5 m depth including sorting out and 31.48 Cu.mt 272.57
stacking of useful materials and disposing off the excavated stuff upto
Meter lead.(B) Dense or Hard soil
2 Excavation for foundation for depth from 1.5 m to 3.0 m including sorting 9.08 Cu.mt 295.10
out and stacking of useful materials and disposing off the excavated stuff
upto 50 Meter lead.(B) Dense or Hard soil
3 Providing and laying cement concrete work 1:2:4 (1- Cement : 2- Coarse 3.15 Cu.mt 4352.09
sand : 4- graded stone aggregates 20 mm nominal size) and curing
complete Including cost of formwork But Excluding The Cost Of
reinforcement for reinforced concrete work in (A) Foundations, footings,
Base or columns and Mass concrete .(For PCC)
4 Provinding and laying controlled cement concrete M -250 and finishing 4.04 Cu.mt 4768.21
smooth with curing etc complete, including the cost of formwork but
excluding the cost of reinforcement for R.C.C. work in(A) Foundations,
footings, Base of Columns and Mass concrete. (For Pad Footing)
5 Providing and laying controlled c.c. M.250 & curing complete including 2.12 Cu.mt 7967.89
the cost of form work but excluding the cost of reinforcement for
reinforced concrete work in Collumns, pillars, posts & struts upto floor
two level for G.F. (For Column Up to PL)
6 Providing and laying controlled cement concrete M.250 and curing 5.05 Cu.mt 6053.94
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C) Slabs, landing, shelves,
Balconies, Lintels, Beams, Girders and Cantilever upto floor two
level.(For Ground Beam)
7 Filling available excavated earth (Excluding rock) in trenches plinth, sides 27.36 Cu.mt 136.92
of foundation etc in layers not exceeding 20 cm in depth consolidating
each deposited layer by ramming and watering.
8 Filling in foundation and plinth with murrum or selected soil in layers of 30.96 Cu.mt 295.15
20cm. thickness including watering, ramming and consolidating etc.
9 Filling in plinth with sand under floors including watering, ramming 2.40 Cu.mt 479.80
consolidating and dressing etc. complete.
4. Library Building Page
Item of work Quantities Rate in Amount
Estimated Unit Figures in
10 Anti-Termite System:Providing and laying of permanent piping technology 48.00 Sq.mt 63.63
anti-termite treatment before flooring work by installing LLDP (Low linear
density polyethylene) tube of 8 mm O.D. & 6.4 mm 1.D. with inbuilt
pressure compensation chip every 30 cm interval in the tube, having
working pressure of 2 Kg/cm2 and release rate of 1.9 Itr/hour fixed by P-
clips and nails. The LLDP pipe shall be installed at the entire periphery of
the building and at internal network of building at a depth of 20 to 200 mm
under floor at every 2 to 3 mtr. c/c distance (adjusted as per building
layout ) & Ends of loop pass through a PVC elbow of minimum 32 mm ID
at junction box of wall and floor level, entering into a steel reinforced
grooved flexible pipe of minimum 22 mm ID leading into junction box and
the loops shall terminate in junction boxes & test every junction during
injecting chemicals for termite control treatment. The anti termite
chemical Imidacloprid 30.5% SC mix as per IS-6313 (part III) shall be
injected by the pressure pump diluted with water @ 10.5 ml/5 ltr of water
at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The contractor shall submit
approved line plan for piping system and junction boxes dully approved
by Engineer-in-Charge with bond of 5 year warranty.(II)Anti Termite
chemical injected area (Chemical injecting incl. labour cost)
11 Providing and laying damp proof course 25mm thick cement concrete 10.96 Sq.mt 321.97
1:2:4 (1-Cement : 2 coarse sand : 4 stone aggregate 10 mm nominal
size) and curing complete
12 Brick work using common burnt clay building bricks having crushing 8.20 Cu.mt 4214.33
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional
13 Brick work using Common burnt clay building bricks having crushing 16.43 Cu.mt 4496.05
strength not less than 35 kg/sq.cm in Super Structure above floor Two
Level in cement mortar 1:6 ( 1 cement : 6 fine sand ) (B) Conventional.(
For B/W Up to GF Slab)
14 Providing and laying cement concrete 1:3:6 (1- Cement : 3- Coarse sand 1.65 Cu.mt 4147.33
: 6- crushed stone aggregates 20 mm nominal size) and curing complete
including cost of formwork in (A) Wall Caps / Coping
15 Providing and laying controlled cement concrete M.200 and curing 1.00 Cu.mt 7821.44
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and Cantilever
upto floor two level. (For Lintel)
16 Providing and laying controlled cement concrete M.200 and curing 0.90 Cu.mt 6907.39
complete Including the cost of formwork But Excluding the cost of
reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and Cantilever
upto floor two level.(For Chajja)
17 Providing and laying controlled c.c. M.200 & curing complete including 2.49 Cu.mt 7934.56
the cost of form work but excluding the cost of reinforcement for
reinforced concrete work in Collumns, pillars, posts & struts upto floor
two level for G.F.(For Column)
18 Providing and laying controlled cement concrete M.200 and curing 5.05 Cu.mt 6560.96
complete Including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and
Cantilever upto floor two level. (For Beam)
19 Providing and laying controlled cement concrete M.200 and curing 7.20 Cu.mt 4877.29
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and Cantilever
upto floor two level.(For Grade slab)
4. Library Building Page
Item of work Quantities Rate in Amount
Estimated Unit Figures in
20 Providing and laying controlled cement concrete M.200 and curing 7.92 Cu.mt 6658.93
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and Cantilever
upto floor two level.(For slab)For GF Slab
21 Providing TMT Bar FE 500D reinforcement for R.C.C. work including 4750.00 Kg 77.29
bending, binding and placing in position complete upto floor two level.
22 Providing and fixing M.S. Fan clamps type 1 to 16mm dia M.S. bar bent to 10.00 Nos 136.75
shape with hooked ends to R.C.C. slabs curing, laying including painting
the exposed portion of loops, all as per standard design complete
23 Providing & fixing 40 mm thick Single shutter flush door solid core 3.78 Sq.mt 7461.88
finished with both side 1 mm thick lamination both side like 'NOVAPAN
'or equivalent, of natural wood grain shade as approved by this office
having telephone black granite 18 mm thick frame with double stone as
per the instruction of Engineer in charge.with necessary SS hinges and
fixtures etc . complete.
24 Providing and fixing window having extruded aluminum colour anodized 11.91 Sq.mt 3199.68
section frame main outer size 95mm x 24mm x 1.17mm (of Jindal section
no.2459 @ Wt. 0.738 Kg/mt), horizontal three track member size 92mm x
31.75mm x 1.30mm (of Jindal section no. 8688, @ Wt. 1.07 Kg/mt),
vertical member of size 92mm 31.75mm x 1.50mm (of Jindal section no.
8933 @ Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size
40mm x 18mm x 1.29mm (of Jindal Section No. 8947 @ Wt. of
Kg/mt), vertical member of size 40mm x 18mm x 1.29 mm (of Jindal
section no: 8949 @ Wt. of 0.456 kg / mt) with 5 mm th transparent bronze
colour tinted float glass with powder coated aluminum fittings and fixtures
and transparent silicon sealant glass fixing Including Granite Frame as
per details etc.
25 Providing and fixing M.S. grills of required pattern to 214.33 KG 147.46
wooden/Marble/Granite/Stone frames of windows etc. with M.S. flats at
required spacings and frame alround, square or round bars with round
headed bolts and nuts or by screws (A) Ornamentle Grill.
26 P & L 24" x 24" vitrified 8 mm thick tile flooring over 20mm (average) 44.28 Sq.mt 1401.38
base of cement mortar 1:6 ( 1 cement: 6coarse sand) on new surface or
fixing on existingflooring by adhesive material including dismentaling
ofexisting flooring and jointed with color cement slurryincluding finised
with flush pointing & cleaning thesurface etc. complete for light shade
27 Providing and laying Marbo Grenite tiles 8 to 10 mm thick , 24'' x 24'' in 6.36 Sq.mt 1195.02
skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-
cement : 3-coarse sand) and jointed with white cement slurry
28 Providing and laying broken china mosaic flooring for terrace 56.40 Sq.mt 779.70
using 12 mm to 20 mm broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to be tempered to bring
mortar creme out upto surface using white cement including rounding
off junctions and extending them upto 15 cm along the wall,clearing with
water and oxalic acid etc. as directed.
29 Providing and laying BBCC of 75mm th. Layer in CM (1:3) including 48.00 Sq.mt 689.83
sparaying two coat of water proofing chemical with selected brand by
enginner incharge .i.e.perma or other with leveling complete for ready
base of china mosaic tratment.
30 Providing and cement vata (10cm x 10cm size) quarter round in cement 28.00 Rmt 24.28
mortar 1:1 including neat cement finishing watering etc. complete.
4. Library Building Page
Item of work Quantities Rate in Amount
Estimated Unit Figures in
31 Providing 15mm thick cement plaster in single coat on Rough 33.27 Sq.mt 175.39
(Similar)side of single or half brick walls for interior plastering upto floor
two level and finished even and smooth in (ii) Cement mortar 1:4 (1-
cement :4-sand) (Interior Plaster)
32 Providing 15mm thick cement plaster in single coat on ceilings and sofits 44.28 Sq.mt 201.44
of stairs upto floor two level instead of plastering on walls and finished
even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) (For
Ceiling Plaster)
33 20mm thick sand faced cement plaster on walls upto height 10 metres 172.03 Sq.mt 345.75
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand)With Chiken mesh and 8mm thick finishing coat of C.M.
1:1 (1-cement : 1-sand) etc. complete.
34 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 21.30 Rmt 43.05
35 Applying two coats of putty & two coats of primer of approved brand and 33.27 Sq.mt 40.59
manufacture on new wall surface to give an even shade including
thoroughly brushing the surface free from mortar dropping and other
foreign matter and sand papered smooth. (Interior Wall Putty)
36 Applying two coats of putty & two coats of primer of approved brand and 44.28 Sq.mt 42.77
manufacture on new wall surface to give an even shade including
thoroughly brushing the surface free from mortar dropping and other
foreign matter and sand papered smooth. (Ceiling Putty)
37 Wall painting two coats with plastic emulsion paint of approved brand 33.27 Sq.mt 82.85
and manufacture on wall surfaces to give an even shade including
throughly brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth. (Interior Wall Paint)
38 Finishing wall with weather proof exterior emulsionpaint on wall surface 172.03 Sq.mt 120.26
(two coats) to give an requiredshape even shade after thoroughly
brushing the surfaceto remove all dirt, and remains of loose powdered
materials.etc complete (Exterior Wall Paint)
39 Wall painting two coats with plastic emulsion paint of approved brand 44.28 Sq.mt 85.03
and manufacture on wall surfaces to give an even shade including
throughly brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth on ceiling. (Ceiling Paint)
40 Providing laying and jointing in true line and level 110 diameter U.P.V.C. 16.00 Rmt 876.90
SWR Type B pipe confirmng to IS 13592-1992 with one end plain and
other end socketed with rubbering, & fitting conforming to ISI 14735-1999
of approved make for drainage system pipe line, pipe shall be jointd with
each other with rubber lubricant, pipe shall be fixed on wall using of PVC
clamp of the size 110 mm diameter x 149 mm length x 145 mm high at
every 2000 mm center to center or shall be concealed in walls as
directed including necessary fittings such as Cowel vent, bends, shoes
etc. including testing of pipes and joints and jointed with adhesive solvent
cement including cost of all materials.
41 Clearing and grubbing road land including uprooting rank vegetation 0.012 Ha. 84255.99
grass bushes,shrubs,sapling and trees girth up to 300 mm removal of
stumps of trees cut earlier and disposal of unserviceable materials(A) By
manual means in area of light jungle
4. Library Building Page
Item of work Quantities Rate in Amount
Estimated Unit Figures in
42 Providing and fixing eco-friendly light weight calcium silicate false ceiling 48.000 Sqmt 1674.15
tiles having Tegular edge & 15 mmThick Densified edges on the Tile
Periphery for Extra Strength The Light weight calcium silicate ceiling tiles
shall have , light reflection 85% non combustible as per B.S. 476 part IV,
100% humidity resistance and also having thermal conductivity0.043°
w/m KC.for the best thermal Insulation . The Light weight calcium Silicate
tile shall be of approved texture Fine fissured/ Spintone/Cosmos having
NRC value of 0.5 & Globe having NRC value of 0.75 NRC or equivalent
of size 595 X 595 mm to be laid on true horizontal level suspended inter
locking metal grid of hot dipped galvanized steel sections (galvanizing
@120 grams per sqm including both side) consisting of main ‘T’ runner
suitably spaced at joints to get required length and size of 24X38mm
made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre,
and cross ‘T’ of size 24X28mm madeout of 0.33mm (Minimum) sheet
spaced 1200mm along spaced between main ‘T’ at 600mm centre to
centre to form agrid of 1200X600mm and secondary cross ’T’ of length
600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to
be interlocked at middle of the 1200X600mm panel to form grid of size
600X600mm resting on periphery walls/partitions on a perimeter wall
angle pre-coated steel of size (24X24X3000mm made of 0.40mm thick
(minimum) sheet with the help of rawl plugs at 450mm centre to centre
with 25mm long dry wall screws @ 230mm interval and laying 15mm
thick Densified edges light weight calcium silicate ceiling tiles of approved
texture (Fine Fissured/Cosmos/Spintone) in the grid including, cutting
/making opening for services like diffusers, grills, light fittings, fixtures,
smoke detectors etc., wherever required, Main ‘T’ runners to be
suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm
fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I.
adjustable rods with galvanized steel level clips of size
85X30X0.8mm,spaced at 1200mm centre to centre long main ‘T’ bottom
exposed with 24mm of all T-sections shall be pre-painted with polyester
baked paint, for all heights, as per specifications, drawings and as
directed by engineer-in-charge.Note:- Only calcium silicate false ceiling
area will be measured from wall to wall. No deduction shall be made for
exposed frames/opening (cut outs) having area less than 0.30 sqm. The
calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) for
Fine fissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection
85% non-combustible as per B.S. 476 part IV, 100% humidity resistance
and also having thermal conductivity. 0.043° w/m KC.for the best thermal
43 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm Each 13.00 485.81
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of pipe erected
with 6A Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed
in wall/ceiling complete
4. Library Building Page
Item of work Quantities Rate in Amount
Estimated Unit Figures in
44 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) Each 4.00 674.68
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected with 6A
Modular type switch and hum free EME step type electronic fan regulator
mounted and accessories with earth continuity of following type erected
on PVC / Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling rose / H.D.Connector as
(f) with medium class Rigid PVC pipe and accessories erected concealed
in wall/ceiling complete
45 Point wiring for on board Looped Plug with 6A Modular type switch & 5 Each 8.00 257.55
pin socket erected on PVC / Metallic/Wooden box, single mounting base
frame covered with textured / metallic/white front plate modules erected
on / in wall / ceiling with following type accessories
46 Providing & erecting insulated socket 3P+N+E with Plug16A rating which Each 3.00 1706.90
is comprised of Four pole MCB slot and insulated socket IP40 cat-III
47 Supplying and erecting led lamps with following wattage capacity of 220 Each 6.00 80.80
to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22
lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser suitable LAMP holder
(ii) 5 to 8 watts
48 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt Each 5.00 427.23
to 0.5 Watt assembled on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. &
corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV - Cat III
49 Providing and erecting Street Light pole bracket comprising main B Class Each 1.00 683.77
GI pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I.
sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /80mm /
required size of pole top having sufficient fasteners for fixing the brackets
and having spread of 1.5.mtr. length with 110 deg.with vertical plane &
suitable welded stays, reducer and with check nuts complete painted with
one coat of Red oxide / PU base primer and two coats of Aluminium / PU
paint. paint with following nos of arms.
[A] Single Arm Bracket 1.5 Mtr
4. Library Building Page
Item of work Quantities Rate in Amount
Estimated Unit Figures in
50 Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with Each 3.00 1948.29
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium blades with , canopy & 30 cm.
down rod erected with earthing.(Make shall be approved by Engineer in charge))
Rs. Twelve Lakh Twenty Two Thousand Five Hundred Thirty Two Rupees And Fifteen N.P. Only
I / We am / are willing to carryout the work at ………..% above/Below percent (………………………. Percent above/Below)
(Should be written in figure and words) of the estimated rates mentioned above. Amount of my / our tender worked out as
Estimated amount put to tender Rs: ……………. Estimated amount put to tender Rs: …………...
Deduct……% below Rs: …………………………. Add……% above Rs: ………………………….…
(Please strike out which ever is not applicable.)
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra
payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost of
difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Quantities rate and wordings of items are as per estimate and calculation in the Sch. - B are airthmatically checked.
Above all items of "Schedule-B" with Item Description, Unit, Rate & Amount have verified by me and found
Sr.Divisional Account Officer Dy.Executive Engineer
Panchayat (R&B) Division Panchyat (R & B) Sub Division
Mahisagar Lunavada
Signaturre of contractor Executive Engineer
with seal Panchayat (R&B) Division
4. Library Building Page
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
8 Electrical Tender General Specificatioin.pdf
11.All GR and Special Condition.pdf
2.SBD.pdf
BOQ Library Building.pdf
Specifications for Library.pdf
Testing schedule.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .