| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.6 L+₹3.0 L (13.9%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.7 L+₹3.1 L (14.5%)Rejected-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L3 | Rejected-AOC L3 | |
| 4 | L4₹25.0 L+₹3.4 L (15.9%)Rejected-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹28.0 L+₹6.4 L (29.7%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
25 Jan 2020, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015 Tele 0361 2841626
REPAIR REPLACEMENT AND PERIODICAL MAINT OF TRANSFORMER POWER TRANSFORMER COMPACT SUBSTATION HT CABLE VCD CT PT RMU VOLTAGE STABLIZER AND ALLIED WORKS AT AIR FORCE STATION TEZPUR UNDER GE AF TEZPUR
2019_MES_310259_1
CWE (AF)/TEZ/TOKEN-31 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Tezpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF Tezpur
₹48,000
Yes
6 Mar 2020
30 Dec 2019
27 Jan 2020
30 Dec 2019
25 Jan 2020
13 Jan 2020
Amount
Testing and calibration of 11 KV HT VCB panel protection relays over current/ earth fault, tripping and closing circuits by primary and secondary injection method for their optimal tripping and closing performance including resetting of the time whenever required including submission of test report in duplicate complete all as directed. Note: (i) Measuring instrument required for calibration and testing has to be supplied by the contractor. (ii)Testing and Calibration should be done through State Government approved License holder only.
Supply only LED type indicator lamps of red/yellow/blue/green/Amber with bulb complete all as directed. Make: C&S/ L&T/AE
Supply only digital type ammeter of 0 to 400 Amps capacity, square type of size 96x96mm with CTs of suitable ratio complete all as directed. Make: AE/MECO/L&T
Supply only TNC (Trip neutral close) switch for HT VCB complete all as directed. Make: Seimens/AE/GE
Supply only panel type strip heater 80W capacity with thermostate complete all as directed. Make : Siemens/AE/GE
Supply only 11 KV single phase indoor resin cast CT of ratio 300-150/5+5 A Class 1.0/5P10, Burden 15 VA STC:13.1 KA for 1 sec Complete all as directed. Make CG/AREVA
Supply only intrrupter for vaccum circuit breaker of 11 KV Voltage rating , 400/630/800 Amps, 3 phase, 50 cycles from the 11 KV HT panel board complete all as directed. Make : Siemens/AE/GE/L&T
Supply only HT 11 KV VCB spout assembly on existing location complete all as directed. Make : Siemens/AE/GE/L&T Note: - Cost of HT insulation shall deemed to be included in quoted rate.
Disconnecting and cutting down the existing unserviceable /burnt out HT cable end joints, outdoor type (Heat shrinkable) 11kV grade suitable for XLPE cables of size 120 Sqmm,3 core and supply and jointing new HT cable end joint of size 120 Sqmm, 3 core, outdoor type (Heat shrinkable) including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable end joints, indoor type (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm,3 core and supply and jointing new HT cable end joint of size 120 Sqmm, 3 core, indoor type (Heat shrinkable) including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnecting and cutting down the existing unserviceable /burnt out HT cable straight through joints of 120/180 Sqmm 3 core, supply and jointing HT cable straight through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120/180 Sqmm,3 core including testing complete all as directed. Make : RAYCHEM/M-SEAL/3M
Disconnection the HT ,LT & Earth Connection of Transformer of capacity 300 KVA to 630 KVA and lifting it from its installation place and transportation to civil workshop at Tezpur for repair and transporting back to its existing installation and install at its original foundation including connecting the HT,LT & Earth connection of transformer foundation bolts etc including removing old painting by scraping and applying two coats of synthetic enamel paint by sparay machine, writing of SM No/MES No complete all as directed. NOTE: (a) Spare parts will be mesured and paid seprately under relevant items. (b) Cost of Transformer oil for cleaning by hoisting down shall be deemed to be included in the qouted rates.
Rewinding of transformer of 300 KVA capacity by supper enamelled copper wire as per existing gauge of primary coil with E class insulation varnishing and baking the coil properly fixing on core and making connection to achieve rated voltage and current complete all as directed.
Rewinding of transformer of 630 KVA capacity by suprer enamelled copper wire as per existing gauge of primary coil with E class insulation varnishing and baking the coil properly fixing on core and making connection to achieve rated voltage and current complete all as directed.
Supply only supper enameled copper strip of approved quality and suitable gauge for LT side of transformer as per the rated KVA requirment of the transformer of 11/0.433 KV grade complete all as directed.
Supply only approved quality copper wire of suitable gauge and size suitable for winding HT side of transformer to achive required rated KVA 11/0.433 KV grade complete all as directed.
Supply only gasket set for transformer top lid cover 6 to 8 mm thick ,LT and HT terminal bushing suitable for transformer of capacity 300 KVA to 630 KVA complete all as directed.
Supply and fix gasket set for transformer top lid cover 6 to 8 mm thick , cork sheet, LT and HT terminal bushing suitable for transformer of capacity 5 MVA complete all as directed.
Taking down the defective air breathers from the transformers, supply and fix new breathers suitable for step down distribution transformers of any make and capacity ranging from 63 KVA to 250 KVA including filling of new silica gel in breathers complete all as directed.
Taking down the defective air breathers from the transformers, supply and fix new breathers suitable for step down transformers of any make and capacity ranging from 315 KVA to 500 KVA including supply and filling of new silica gel in breathers complete all as directed.
Taking down the defective air breathers from the transformers, supply and fix new breathers suitable for power transformers of any make and capacity 5 MVA including supply and filling of new silica gel in breathers complete all as directed.
Supply and topping up transformer oil conforming to IS: 335(1993), dielectric strength not less than 45 KV for 60 Sec at 2 mm gap in various capacities distribution transformers installed at various indoor and outdoor sub stations complete all as directed. Make: Power oil/SERVO/Castrol/Shell.
Dehydration of transformer oil of various capacities distribution transformers installed at various indoor and outdoor substations with ultra high vacuum filtration machine to obtain the dielectric strength of 45 KV for 60 Sec at 2 mm gap complete all as directed.
Supply & fix in repair silica gel in packet use for breather assembly of transformer complete all as directed.
M&L for carrying out following testing/checking, calibration of power transformer 33/11KV for 2 times during period of contract :- (a) IR value of winding. (b) Checking for the operation of alarm/triping function bucholtz relay, PRV, oil & winding temperature contacts/relays, overload and earth fault relay and calibrate the same. (c) Earth Resistance checking Note: (a) Proper record of testing, checking shall be maintained duly signed by contractor & Engr-in-charge. (b) Each test shall be carried out twice in the contract period and cost for complete tests shall be considered as one job for particular transformer. (c)T&P required for testing shall be arrangd by the contractor at his own cost and nothing extra shall be admissible . (d) Test report of each test shall be submitted by the contractor on completion of test. (e) Test shall be carried out at site only and nothing extra shall be paid toward transportation charges & T&P required for testing.
Servicing , calibration , trouble shooting , repairing , adjustment & cleaning of fixed and moving contacts, checking of vacuum of interrupter, IR value etc. of the 33KV HT VCB outdoor type by qualified technical personnel to make functional in all aspect and complete the Job as directed. Note: (i) Cost of release ,closing coil is excluded in the unit rate of this item , however same shall be paid under relevent item as supply only . (ii) Unit rates of this items includes the labour charge and T&P required for completion of the job and cost of this item also include element of taking out of defective parts. (iii) Other material required for completing job except release & closing coil shall be arrange by the contractor at his own cost & nothing extra is admissible on this account . (iv) Contractor shall provide the calibration certificate on completion of this particular job.(v) Work against calibration shall be carried out at site & necessary arrangement shall be provided by the contractor at own cost (vi) T&P required for this job shall also be arranged by the contractor and nothing extra shall be admissible on this account .
Supply only Release and Trip coil 30V DC suitable for 33KV HT VCB outdoor complete all as directed. Make :- ABB/Schenider/Crompton
Material & Labour for carrying out testing, calibration of relays and resetting complete of breaking capacity of VCB of 33KV with Current Injection Machine of suitable capacity complete all as directed. .Note: (a) Proper record of testing ,checking shall be maintained & sign by contractor & Engr-in-charge. (b)T&P required for testing shall be arrangd by the contractor at his own cost and nothing extra shall be admissible (c) Test report of each test shall be submitted by the contractor on completion of test. (d) Test shall be carried out at site only and nothing extra shall be paid toward transportation charges of T&P required for testing.
Supply and fixing in repair new alluminium pad clams including nut & bolts complete all as directed.
M&L for applying Anti corrosive gel to pad clamps, bolts and nuts complete all as directed.
Dismantling existing PT/CT outdoor type 33 KV/110V and rewinding with insulated wire/strip as per existing, Re-fixing and testing complete all as directed.
Supply and installation in repair 33 KV single phase outdoor ODVT type STD IS2705 CT of ratio 200-100/5A Class 1.0/5P 10, Burden 15 VA STC:18.4 KA for 1 sec complete all as directed.
Supply and installation in repair 33 KV single phase outdoor ODVT type STD IS 3156 PT of ratio 33000/√3/110/√3 V 200 VA 1 CL 18.4 KA for 1 sec complete all as specified and directed
Supply and fixing in repair 33 KV Lightining arrester expulsion type with all fittings ,transmission class , discharge capacity 65 kilo amp complete all as directed.
Supply fix in repair HT ceramic bushing for 5 MVA Power Transformer complete all as directed
Supply fix in repair LT ceramic bushing for 5 MVA Power Transformer complete all as directed
Trimming of tree branches over to O/H conductor of 33 KV/11 KV line,Transformer in 33 yard and removing the same at a distance upto 50 mtrs with the 4 Nos unskilled labour per day with required tools and safety equipments complete all as directed. Note. (a) Proper shutdown shall be taken before trimming of tree branches. (b) The rate of T&P used in trimming of Tree branches included in quoted rate. (c) Over head line distance from daputa to the AF station upto 33 yard is 8.5 Km and inside the station.
Repairing, servicing and testing of battery charger with automatic float boost suitable for charging the 110 V battery bank 2 V 120 AH VRLA type battery of 55 Nos total 110 V DC by replacement of Amp/Voltmeter winding of transformer, control wiring , control circuit complete all as directed.
Repair/replacement of male & female contact blade of horizontal operation air break isolator 630 A 33 KV at OH gang way for set of 3 Nos complete all as directed.
KAILSON
kabitaconstruction
MAHANTA ENTERPRISES
M/S A K MITRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .