Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC PAIDI POST FARIDPUR BHOGI NAGINA ROAD BIJNOR UP 246701 | BIJNOR | BIJNOR | UP | 246701 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹18.6 L+₹2.6 L (16.1%)Rejected-Finance C O BHUSHANA COLONY BAREILLY UP 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹28.4 L+₹12.3 L (76.9%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
| Sl No | Description | Qty | Unit | S.M. KAZIM L1 | Janta Constructions L2 | OM SAI ASSOCIATES AND DEVELOPERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | B&R PORTION :
M&L for complete removal of existing treatment by scrapping with mechanical wall sander (mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc all as directed. | 19,000 | Sqm | 4 ₹76,000 Lowest | 4 ₹76,000 Lowest | 8 ₹1,52,000 |
| 2.00 | M&L for preparation of old treated surfaces of walls by scrapping with mechanical wall sander (having mechanical vaccum machanism), scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying three coats of white wash all as specified. | 3,000 | Sqm | 4 ₹12,000 Lowest | 7 ₹21,000 | 25 ₹75,000 |
| 3.00 | M&L for preparation of old treated surfaces of ceiling by scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying three coats of white wash all as specified. | 5,000 | Sqm | 4 ₹20,000 Lowest | 8 ₹40,000 | 27 ₹1,35,000 |
| 4.00 | M&L for preparation of old decorated surfaces of walls and cornices by booming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage certified by paint manufacturer and as mentioned in particular specification including accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface all as specified and directed. | 4,000 | Sqm | 15 ₹60,000 Lowest | 19 ₹76,000 | 37 ₹1,48,000 |
| 5.00 | M&L for applying 2mm (average) thickness white cement based putty including sand papering the puttied surfaces to form an even and smooth surface all as specified. | 16,000 | Sqm | 19 ₹3,04,000 | 21 ₹3,36,000 | 15 ₹2,40,000 Lowest |
| 6.00 | M&L for preparation of wall surfaces scrapped by wall sander and applying two coats of oil bound distemper over a coat of alkali resistant primer on wall using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified. | 16,000 | Sqm | 25 ₹4,00,000 Lowest | 30 ₹4,80,000 | 48 ₹7,68,000 |
| 7.00 | M&L for preparation of old surface of ceiling including brooming down or steel brishing, scrapping down smoke, soot, moulds, moss and efflorescent salts, dust and loose paint etc and applying one coat of oil bound distemper on complete all as specified. | 700 | Sqm | 15 ₹10,500 Lowest | 20 ₹14,000 | 30 ₹21,000 |
| 8.00 | M&L for preparation of old treated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified. | 5,200 | Sqm | 25 ₹1,30,000 Lowest | 31 ₹1,61,200 | 62 ₹3,22,400 |
| 9.00 | M&L for preparation of old treated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified. | 2,000 | Sqm | 24 ₹48,000 Lowest | 29 ₹58,000 | 65 ₹1,30,000 |
| 10.00 | Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete including removing the debris from site to out side MoD land | 140 | Sqm | 12 ₹1,680 Lowest | 20 ₹2,800 | 20 ₹2,800 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Feb 2026, 6:00 pmClosed
GE (AF) Bareilly
GE (AF) Bareilly-243002 (UP)
MAINTENANCE OF CERTAIN B/R ASSETS IN SMQ OF TV AREA AT AF STN BAREILLY UNDER GE(AF) BAREILLY
2026_MES_751241_1
GE(AF)/BLY/T-59 OF 2025-2026
Open Tender
Civil Works
Item Rate
180 days
Bareilly
Class-D Category a(i)
8 documents required · 8 mandatory
₹500
GE (AF) Bareilly
₹60,000
Yes
6 Apr 2026
4 Feb 2026
27 Feb 2026
4 Feb 2026
25 Feb 2026
19 Feb 2026
B&R PORTION : M&L for complete removal of existing treatment by scrapping with mechanical wall sander (mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc all as directed.
M&L for preparation of newly surfaces of walls by scrapping with mechanical wall sander (having mechanical vaccum machanism), scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying three coats of white wash all as specified.
M&L for preparation of newly surfaces of ceiling by scrapping with mechanical wall sander (having mechanical vaccum machanism), scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying three coats of white wash all as specified.
M&L for preparation of old decorated surfaces of walls and cornices by booming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage certified by paint manufacturer and as mentioned in particular specification including accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface all as specified and directed.
M&L for applying 2mm (average) thickness white cement based putty including sand papering the puttied surfaces to form an even and smooth surface all as specified.
M&L for applying two coats of oil bound distemper over one coat of alkali resistant primer on wall using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified.
M&L for preparation of old surface of ceiling including brooming down or steel brishing, scrapping down smoke, soot, moulds, moss and efflorescent salts, dust and loose paint etc and applying one coat of oil bound distemper on complete all as specified.
M&L for preparation of old treated wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
M&L for preparation of old treated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete including removing the debris from site to out side MoD land
M&L for rendering 15mm thick in cement mortar (1:6) on concrete or brick masonry surfaces including finisheing surface even and smooth without using extra cement all as specified.
M&L for 5 mm thick rendering in cement mortar (1:3) on concrete surfaces on ceiling including finishing surface even and smooth without using extra cement all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding/ terrazo dado (but not backing) including removal of debris from site to outsite MoD Land
M&L for 25mm thick cement concrete in 1:2:4, type B-0 using 12.5mm graded stone aggregate as in sub base for floor finishes all as specified.
M&L for vitrified ceramic light shade tile first quality 10 mm thick (square/ rectangular) polished area of each tile not exc. 0.36 Sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 complete all as specified. [Note: The colour / shade / design of tiles shall be as approved by GE.]
M&L for Glazed ceramic coloured tiles joint free first quality of size 350 mm x 250x 7 mm/ 450X 350X 7mm thick on vertical surface such as dado,skirting, wall etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick first quality (Square/ Rectangular) shed area of each tile exc. 0.11 Sqm but not.exc. 0.18 Sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including over 15 mm thick screed bed in cement mortar (1:6) all as specified.
M&L for taking down shutter of any description exc 1.00 Sqm and not exc 2.00 Sqm each including easing and adjusting, refixing builders hardware and refixing in same opening complete all as specified.
Taking down chowkats or frames with shutter (without taking off shutter from frame) including fittings area exc 1.5 Sqm but not exc 4 Sqm each.
Taking down shutter from frame with fittings area exc 1 Sqm but not exc 2 Sqm each.
M&L for 35 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, commercial type on one side and one face is covered with decorative face veneer with lipping/frame to match all as specified.
M&L for 35 mm thick factory made second class hard wood glazed and skeleton door shutter, open rebated and prepared to receive glass, gauze etc fitted with cut and mitred beads for securing glass, gauze etc for door shutters; sizes of members of shutters as specified in SSR Part-I, Section 8. clause 8.24 (a); supplied and fitted to chowkats all as specified.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
M&L in repair 18/19mm prelaminatd particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified.
M&L in repair 12 mm prelaminatd particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work all as specified.
S&F for continuous (piano) hinges, mild steel, bright finish width of flaps (when open) in 30 mm electrogalvanised all as specified.
M&L for preparation to newly wooden surfaces of any description not otherwise described over 10 cm wirdh or girth and applying two coats of synthetic enamel paint (1st quality) over one coat of pink primer all as specified
S&F for factory made PVC door frame of size 50 mm x 47 mm with a wall thickness of 5mm grid PVC sheet mitered at corner and pinned with two members 150 mm long brackets of 15 x 15mm MS Square tube 19 gauge EPDM rubber gasket weathered sheet to be provided through the frame, door frame to be fixed to the wall using MS screw of 65/100mm size as per manufacturer's specification all as specified.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in bed block, hold fast etc including necessary from work all as specified.
S&F for mild steel for bends, straps, supports or stays for rainwater, hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified.
S&F for 100 mm long stainless steel butt hinges with stainless steel hinge pin ISI marked all as specified.
S&F for 150 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed all as specified.
Hacking out old broken glass of any description from old wooden/ steel/ concrete or brick surface any thickness or size all as specified.
S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified.
S&F in repairs 15 mm dia bib tap, brass chromium plated, fancy type with crutch or butterfly handle screwed down, screwed all as specified.
S&F in repairs vitreous china sqautting pan orissa pattern size 580 x 440 mm white with intergral foot rest including cast iron "P" or "S" trap and PVC flush pipe including making good floor as per existing all as specified.
S&F in repairs vitreous china wash down water closet pan (pedestal Pattern) white colour, including 10 ltr capacity PVC syphonic action type flush low level with inlet, ball valve float and handle, flush pipe 32 mm dia, brackets, plastic seat cover white complete all as specified.
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing all as specified.
S&F for 15 mm bore galvanised steel tubing medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified.
S&F for 20mm CPVC pipes SDR 11 & plain CPVC 11 fittings on walls/ ceilling or laying in floors all as specified.
S&F for brass elbow (3/4 inch X ½ inch) all as specified.
S&F for brass Tee 20 mm size all as specified.
S&F in repair 32 mm dia waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm-45 gms/ 40 mm-60 gms all as specified.
S&F in repair 15 mm dia stop valve cast copper alloy, chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all as specified.
M&L for fly ash brick works, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 all as specified.
M&L for cleaning and removing all scale and dirt etc from tank of capacity exc 500 ltrs & not exc 1000 ltrs complete all as specified.
M&L for cleaning and removing all scale and dirt etc from tank of capacity exc 250 ltrs & not exc 500 ltrs complete all as specified.
S&F in repair 20 mm dia gun-metal, glove or gate valve with iron wheel head, screwd both end or iron pipe and fixed all as specified.
S&F in repair 15mm brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed all as specified.
Demolition of cement concrete in ground floor and paving not exc 15 cm thick below or above ground level all as specified.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor all as specified.
S&F for factory made chequered cement concrete tile of size 200 mm x 200 mm x 25 mm thick with grey cement and no pigment, set jointed and pointed in neat cement slurry in floor over 20 mm screed bed or bedding layer for laying floor finish (1:6) all as specified.
E&M PORTION : Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings and making good disturbed surfaces of walls, floors etc to match with existing surface all as specified.
Taking down old unserviceable sub main wiring any type and size (aluminium/ copper) including batten/ conduit and making good disturbed surface to match with existing surface all as specified.
M&L for point wiring using approved colour coding as per IS with 1100 volt grade 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through and including rigid non-metallic PVC conduit heavy duty of size not less than 20 mm dia with all fittings, concealed in wall, roof, ceiling etc including pressed steel concealed terminal boxes 1.2 mm thick 60 mm deep of required size with modular white cover plate with frame for housing switches, sockets, regulators etc. duly earthed with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as continuous earthing wire for one light/ fan/ bell point controlled by one switch one way all as specified.
All as per item No. 58.00 above but for one 3 pin 6 Amp socket outlet on independent board all as specified.
All as per item No. 58.00 above but for one 3 pin 6 Amp socket outlet on same board with other switches all as specified.
All as per item No. 58.00 above but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one 3 pin 15 Amp socket outlet point on independent board all as specified.
S&F in replacement of wall/ surface mounted type LED light fitting batten type complete with LED 1x 20 Watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cableall as specified.
S&F in replacement of wall / surface mounted type LED light fitting batten type complete with LED lamp 10 Watt (2 feet long), poly carbonate body and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable all as specified.
S&F in repalcement of LED bulk head light fitting 10W with IP-65 protection including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to fitting all as specified.
S&F in repalcement of LED Bldg light fitting 25W, IP 65 made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP65 protection, roadway luminaire with high power LED as light source 1 x 25 Watt with all accessories internally pre-wired all as specified.
S&F in repair switch piano flush type single pole one way 5/6 Amp all as specified.
S&F in repair switch piano flush type single pole 2-way 5/6 Amp all as specified.
S&F in repair bell push, flush type, 5 Amps, Single pole, one way, 230 Volts AC circuit.
S&F in repair socket outlet 2 in 1, 3 pin, 5/6 & 15/16 Amp flush type
S&F in repair socket outlet 2 in 1, 3 pin, 5/6 Amp flush type.
S&F in repair switch piano flush type single pole one way, 15/16 Amp.
S&F in repair ceiling rose PVC/ Poly carbonate isolated body three terminals, 230 volts AC all as specified and directed.
S&F in repair rotary type electronic fan regulator 5 Step AC, 230V, single phase.
S&F in repair electric bell 230 Volts AC all as specified.
M&L in repair angle holder, insulated body with back plate with & including LED Lamp 7 watt suitable for batten fitting all as specified.
M&L for submain wiring with two single core 1100 volt grade FRLSH PVC insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25 mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces.
S&F for sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 08 way, double door with 100 Amp rated copper bus bar and metal door with IP - 43 and flush to wall including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified.
S&F in replacement of MCB single pole 240 volts, 'C' curve of rating from 6 to 32 Amps with rupturing capacity 10 KA.
S&Fin replacement of MCB TPN 415 volts, 'C' curve of rating from 63 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables all as specified.
S&F in replacement of MCB SPN 40 to 63 Amps 240 volts, 'C' curve of rating with rupturing capacity 10 KA.
S&F in repair the Industrial laminated hylam sheet of 3 mm thick ISI marked of size 250 mm x 200 mm all as specified.
All as per item No. 81.00 above but for 175 mm x 100 mm.
All as per item No. 81.00 above but for 100 mm x 100 mm.
S&F in repair iron rectangular block for mounting, switches, sockets, fan regulator etc. with 1.6 mm thick of size 100 mm x 100 mm x 50 mm deep all as specified.
All as per item No. 84.00 above but for 175 mm x 100 mm x 50 mm deep.
All as per item No. 84.00 above but for 250 mm x 200 mm x 50 mm deep.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_841383.xls
BOQ • 1.27 MB
TENDER59.pdf
Tender Documents • 1.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .