Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC | ₹4.2 Cr | L1 | Accepted-AOC L1 Bidder. |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
19 Apr 2025, 6:00 pmClosed
Additional Principal Chief Conservator of Forests
Office of the Additional Principal Chief Conservator of Forests ETW wing 4th Floor FHQ Vazhuthacaud Trivandrum
Supply Installation Testing and Commissioning of Hanging Solar Power Fencing Along the Forest Boundaries of Wayanad North and Wayanad South Forest Divisions Wayanad District
2025_FD_740870_2
KFD/SFDA/ETW3-87/2024/(3)
Open Tender
Civil Works - Others
Item Rate
270 days
Wayanad
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹8,850
Yes
₹1 L
Yes
20 May 2025
25 Mar 2025
21 Apr 2025
25 Mar 2025
19 Apr 2025
25 Mar 2025
Amount
Palvelicham ( 1.32 KMS)
od206733/2023_2024: Energizer with following specifications 12 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od204303/2023_2024od204304/2023_2024: : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od204304/2023_2024:Module stand with housing box to accomodate 2 no 100 AH battery
od204305/2023_2024: battery with at least 3 years guaranty
od204306/2023_20245 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od204307/2023_2024: Earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od204308/2023_2024: Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od204310/2023_2024: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od204311/2023_2024: Stainless steel 1.2 mm 304 grade non resting quality
od204312/2023_2024od139642/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od204313/2023_2024 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od204314/2023_2024od139644/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od204315/2023_2024 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od204316/2023_2024 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od204317/2023_2024 : Warning signs poly-ethylene plastic with statutory colors and signs
od204318/2023_2024 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od204319/2023_2024: Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Aranamala to Kallady (4.60 KMS)
od138815/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138816/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138817/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138818/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od138819/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138820/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138820/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138822/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138823/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138824/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138825/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138826/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138827/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138828/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138829/2024_2025 : Warning signs poly-ethylene plastic with statutory colors and signs
od138830/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138825/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139197/2024_2025 Labour engaged for coolie for shifting materials by head load
Channakkolly to Kappikkunnu (4.60 MS)
od138200/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138201/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138202/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138203/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od138204/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138205/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138206/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138207/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138208/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138209/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138210/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138211/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138212/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138213/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138214/2024_2025 : Warning signs poly-ethylene plastic with statutory colors and signs
od138215/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138216/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od138335/2024_2025 Labour engaged for coolie for shifting materials by head load
Kanthanpara to Anadykkap (1 KM)
od138617/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138618/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138619/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138620/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od138621/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138622/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138623/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138624/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138625/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138626/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138627/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138628/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138629/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138630/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138631/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od138632/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138633/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139205/2024_2025 Labour engaged for coolie for shifting materials by head load
Kappikkunnu to Karyampathy (3.25 KMS)
od138340/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects.
od138341/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138342/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138343/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od138344/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138345/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138346/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138347/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138348/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138349/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138350/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138351/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138352/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138353/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138354/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od138355/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138356/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od138464/2024_2025 Labour engaged for coolie for shifting materials by head load
Kommenchery to Subramanyamkolly (3.50 KMS)
od138509/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138510/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138511/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138512/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od138513/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138514/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138515/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138516/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138517/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138518/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138519/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138520/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138521/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138522/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138523/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od138524/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138525/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od138608/2024_2025 Labour engaged for coolie for shifting materials by head load
Kunnumpuram to 10th mile (3.00 KMS)
od139399/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od139400/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od139401/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od139402/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od139403/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139404/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od139405/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od139406/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od139407/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od139408/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od139409/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od139410/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od139411/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od139412/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od139413/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od139414/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od139415/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139454/2024_2025 Labour engaged for coolie for shifting materials by head load
Kuppachi Colony (1.50 KMS)
od139005/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od139006/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od139007/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od139008/2024_2025 : Battery must have 12 Volt 100 AH solar battery with at least 3 years guaranty
od139009/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139010/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od139011/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od139012/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od139013/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od139014/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od139015/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od139016/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od139017/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od139018/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od139019/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od139020/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od139021/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139175/2024_2025: Labour engaged for coolie for shifting materials by head load
Kurichipatta to Channakkolly (5.25 KMS)
od138078/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138079/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138080/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138081/2024_2025 battery with at least 3 years guaranty
od138082/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138083/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138084/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138085/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138086/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138087/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138088/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138089/2024_2025od139016/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138090/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138091/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138092/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od138093/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138094/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od138188/2024_2025: Labour engaged for coolie for shifting materials by head load
Kuttiyamvayal to Meenmutty (3.00 KMS)
od139311/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od139312/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od139313/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od139314/2024_2025 : battery with at least 3 years guaranty
od139315/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139316/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od139317/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od139318/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od139319/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od139320/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od139321/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od139322/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od139323/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od139324/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od139325/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od139326/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od139327/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139329/2024_2025: Labour engaged for coolie for shifting materials by head load
Meenmutty to Bappanam (3.50 KMS)
od139311/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od139312/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od139313/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od139314/2024_2025 : battery with at least 3 years guaranty
od139315/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139316/2024_2025 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od139317/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od139318/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od139319/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od139320/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od139321/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od139322/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od139323/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od139324/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od139325/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od139326/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od139327/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139329/2024_2025: Labour engaged for coolie for shifting materials by head load
Pathramoola to Kakkodan block (3.27 KMS)
od138357/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138358/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138359/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od138360/2024_2025 : battery with at least 3 years guaranty
od138361/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139362/2024_2025 : 5earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138363/2024_2025 : Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138364/2024_2025 : Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138365/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138366/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138367/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138368/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138369/2024_2025: Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138370/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138371/2024_2025: Warning signs poly-ethylene plastic with statutory colors and signs
od138372/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138373/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od138494/2024_2025: Labour engaged for coolie for shifting materials by head load
Rattapuzha to Melmury (6.00 KMS)
od139133/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od139134/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od139135/2024_2025 : Module stand with housing box to accomodate 2 no 100 AH battery
od139136/2024_2025 : battery with at least 3 years guaranty
od139137/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139138/2024_2025: Earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od139139/2024_2025: Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od139140/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od139141/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od139142/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od139143/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od139144/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od139145/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od139146/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od139147/2024_2025 : Warning signs poly-ethylene plastic with statutory colors and signs
od139148/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od139149/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139213/2024_2025: Labour engaged for coolie for shifting materials by head load
Vellolipara to Pathekkarpara (2.00 KMS)
od138708/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od138709/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od138710/2024_2025 Module stand with housing box to accomodate 2 no 100 AH battery
od138711/2024_2025 : battery with at least 3 years guaranty
od138712/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od138713/2024_2025: Earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od138714/2024_2025: Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od138715/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od138716/2024_2025 : Stainless steel 1.2 mm 304 grade non resting quality
od138717/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od138718/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od138719/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od138720/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od138721/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od138722/2024_2025 : Warning signs poly-ethylene plastic with statutory colors and signs
od138723/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od138724/2024_2025 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139203/2024_2025: Labour engaged for coolie for shifting materials by head load
Vengakkode to Chembra (5.00 KMS)
od139633/2024_2025: Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting (4) solar panel option to re charge 12 V Battery (5).Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on 15 kv soak load (2) o/o energy 3.5 }/ minim (3) pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak corrent 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od139634/2024_2025 : Solar Module with following specification(1) 150 wats 12 Volt rating with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od139635/2024_2025:Module stand with housing box to accomodate 2 no 100 AH battery
od139636/2024_2025: battery with at least 3 years guaranty
od139637/2024_2025 : Lightning diverter must be capable of diverting stray lightning the diverted assembly must be adjustable for spark gaps adequate earthing to be provided
od139638/2024_2025: Earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od139639/2024_2025: Super strain insulator
50.10.2 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od139640/2024_2025: Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od139641/2024_2025: Stainless steel 1.2 mm 304 grade non resting quality
od139642/2024_2025 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line and protection of post by hanging 6 nos hanging line around the post.
od139643/2024_2025 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od139644/2024_2025 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od139645/2024_2025 : Digital volt meter must display fence voltage in Kilo vat up to 9.9 KV including all cost
od139646/2024_2025 : Toolkit ( Cutting pliers, twisting tool kit, multi meter, double ended providing spanner )
od139647/2024_2025 : Warning signs poly-ethylene plastic with statutory colors and signs
od139648/2024_2025 : Lead out cable must be double insulated with standing 15 KV voltage and inner core wire must be GI
od139649/2024_2025: Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od139665/2024_2025 : Labour engaged for coolie for shifting materials by head load
Bidder Name
NATURE FENCE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .