Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC Being reasonable | |
| 2 | L2₹11.0 L+₹1.8 L (19.1%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹11.0 L+₹1.8 L (19.3%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹14.5 L+₹5.2 L (56.7%)Rejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L4 | Rejected-Finance Not being L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Please refer Tech Bid Evaluation Summary |
Tender Value
₹15.4 L
EMD Value
₹30,900
Closing Date
14 Nov 2023, 6:00 pmClosed
Lt Col Shilpam Bharali
Garrison Engineer (AF) Military Engineer Services, Bareilly 243002 (UP)
8758 SPECIAL REPAIRS TO CERTAIN FIRE ALARM SYSTEM OF 111 HU AT AF STATION BAREILLY
2023_MES_624166_1
8758/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
Class E
Category c(vi)
8 documents required · 8 mandatory
₹500
Garrison Engineer (AF) Bareilly
₹30,900
Yes
8 Jan 2024
19 Oct 2023
16 Nov 2023
19 Oct 2023
14 Nov 2023
2 Nov 2023
Amount
Supply, installation, testing and commissioning of Fire Alarm main control panel 2 loop microprocessor based addressable intelligent type and compatible with detector for communication to detectors and response indicators together with mimic diagram made on Auto CAD and pasted on Acrylic sheet with data logging facility and 2 X 16 character LDC, conforming to IS:2189 of capacity from 99 detector and 99 modules up to 200 detector and modules complete with PA based evacuation system and suitable for 415 Volts, three phase, 50 Hz having its own standby power backup supply with batteries, battery charger etc. complete. The panel shall also have an auto dialing facility and potential NO & NC contacts and a 80 watts PA amplifier. The panel shall have a capacity of not less than 4 zones complete all as specified including disconnecting and taking out existing unserviceable panel. NOTE:- The complete job includes all type of controls, connected wiring, addressable connections wire of suitable type as required for system (2-conductor cable, 3-conductor cable, networking cable, tripping cable, security cable, alarming wiring etc. up to each smoke cum heat detectors, MCP, Hooters etc. as required for the complete working of the whole fire alarm system as single unit. The PVC copper wiring shall be FLPR rated PVC jacketed cables of required sizes. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Supply, installation, testing and commissioning of Smoke cum Heat Detectors complying with and type certified to EN-45 addressable type micro processor based programmable intelligent type, multi sensor detector with heat and smoke combination with base complete including necessary connection complete all as specified and as directed including disconnecting and taking down old unserviceable detector. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Supply and fixing of addressable type Manual call point break glass type compatible with main fire alarm control board microprocessor based as per IS-2189 and including chain hammer facility and blinking facility complete all as specified and directed including disconnecting and taking down old unserviceable MCP. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Supply and replace Linear Heat Detection Cable including necessary connections complete all as specified and directed. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Supply, commissioning and testing of response Indicator complete all as specified and directed including taking out old unserviceable necessary connections complete all as specified and directed. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Supply and laying sub main FRLS electric cable 02 run of two Core 1.50 Sq.mm multi-stranded armoured copper conductor for wiring of fire detectors with all accessories and cable pointers or shall be painted with FIRE RED tags at an interval of every 1.00 Metre complete all as specified and directed including disconnecting and taking down old unserviceable cable. Make:- Havells/ Polycab/ Anchor
S&F in repairs rigid non metallic PVC conduit including of all tees, bends, elbow, reducer, bell mouth tube ends and fixing accessories such as couplers, locks nuts, saddles, pipe hooks etc of size 25 mm complete all as specified and directed. Make:- Finolex/ AKG/ Sudhakar
Supply, commissioning and testing of addressable control module complete mounting wall/roof/ceiling including taking out old unserviceable module complete all as specified and directed. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Supply, commissioning and testing of addressable fault detector complete mounting wall/roof/ceiling including taking out old unserviceable detector complete all as specified and directed. Make:- ASES Security Pvt Ltd./ Apollo / Advanced (UK)/ Honeywell
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 16 of tender document i.e. Rs. 25,050.00
Sumit Enterprises
Continental Engineers and contractors
D K THUKRAL AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .