Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 CrAccepted-AOC | ₹12.5 Cr Quoted ₹12.6 Cr | L1 | Accepted-AOC Accepted being lowest and quoted amount found reasonable. |
| 2 | L2₹13.2 CrRejected-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹13.2 Cr | L2 | Rejected-Finance Rejected being not lowest. |
| 3 | L3₹13.5 CrRejected-Finance 602 6TH FLOOR BNG HOUSE D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹13.5 Cr | L3 | Rejected-Finance Rejected being not lowest. |
| 4 | L4₹13.6 CrRejected-Finance EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹13.6 Cr | L4 | Rejected-Finance Accepted being lowest and quoted amount found reasonable. Schedule of Credit amount of Rs. 1867605.00
to be deducted to derive amended contract sum. |
| 5 | L5₹13.8 CrRejected-Finance | ₹13.8 Cr | L5 | Rejected-Finance Rejected being not lowest. |
Tender Value
₹14.3 Cr
EMD Value
₹10.4 L
Closing Date
3 Jun 2024, 6:00 pmClosed
CE NW Kochi
Military Engineer Service Naval Base Post Kataribagh Kochi 682004
ADDITIONS/ALTERATIONS AND SPECIAL REPAIR TO BLDG NO P-66 AND P-68 AT SMA RAMESWARAM, KOCHI
2024_MES_650287_1
891060
Open Tender
Civil Works
720 days
Kochi
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
GE Fort Kochi
₹10.4 L
Yes
5 Jul 2024
17 Apr 2024
5 Jun 2024
18 Apr 2024
3 Jun 2024
20 May 2024
Amount
SPECIAL REPAIRS (B/R)
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removal of debris outside MoD land complete all as specified
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including removal of debris outside MoD land complete all as specified
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area e. exc 150 sqcm but n exc 400 sqcm
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required superficial area n. exc 150 sqcm.
Demolition of stone slabs and tiles of any description or thickness laid bedded & pointed in any mortar in floors, aprons etc including removal of debris outside MoD land complete all as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises
Taking up or down 40/50 mm bore steel water tubing and connections
Taking up or down 20 mm bore steel water tubing and connections
Taking up or down 25/32 mm bore steel water tubing and connections
Dismantling of cast iron drain pipes, of 100mm dia fixed to wall or laid under floors complete all as directed.
Dismantling of cast iron drain pipes, of 75mm dia fixed to wall or laid under floors complete all as directed.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) including removal of debris outside MoD land complete all as specified
Dismantling single layer Mangalore pattern, or similar tiles, any size in roofing/ chajjas in small patches from 9th to 12th floor height.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Taking down chowkhat with shutter (without taking off shutters from the frames) not exc 1.5 sqm each
Taking down chowkhat with shutter (without taking off shutters from the frames) exc 1.5 sqm each.
Taking down shutter of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after repair complete all as specified
Dismantling of PVC water tanks n exc. 250 ltrs capacity
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc including removal of debris outside MoD land complete all as specified
Cement concrete tiles 30cmx30cmx25mm thick, machine pressed with grey cement with no pigment, set jointed and pointed in 3 mm epoxy over and including cement screed bed in CM 1:4, 20 mm thick complete all as specified and as directed
Cement concrete, 1:5:10, type E2, using 40mm graded stone aggregate as in filling under sunken floors complete all as specified.
40 mm thick PCC 1:2:4, type B1, using 20 mm graded stone aggregate as padding concrete in Sunken floor finished even and smooth without using extra cement complete all as specified
25mm thick PCC 1:2:4, type B0, using 12.5 mm graded stone aggregate as levelling course under flooring complete all as specified
Apply two coats of brushbond of M/s Fosroc or equivalent on all sides and bottom of sunken slab and providing rendering 10 mm thick CM 1:3 with water proofing liquid. Mix the part A and part B of the polymer modified cementitious coating mechanically using an electrically operated drilling machine fitted with mix paddle. Apply the same in two coats over the prepared surface one after the other dries up with a minimum interval of 4 hours between the coats. Providing pressure grouting in suspected areas of vertical and horizontal joints. The rate shall include for all materials, machinery, labour etc. complete. NOTE : Contractor shall submit 10 years guarantee certificate for the water proofing treatment carried out.
Polished black granite stone slab 18-20mm thick cladding over 10mm thick backing coat in CM 1:3 on entrance of lift wall with fastners of stainless steel; including rounding of edges complete all as specified and as directed. Note : Screed bed/backing coat shall be measured and paid separately.
Polished black granite stone slab 18-20mm thick over 10mm thick backing coat in CM 1:3 as in cooking platform; including rectangular cutting for sink, making circular hole for gas pipe and rounding off exposed edges complete all as specified and as directed. Note : Screed bed/backing coat shall be measured and paid separately.
Screed bed or bedding layer of mortar in CM 1:4,15 mm thick for laying floor finishes complete all as specified
Rendering/backing coat 10mm thick in CM 1:3 on brick work or concrete surfaces to receive wall tiles complete all as specified
Non - skid Ceramic coloured tiles 7 to 9 mm thick ,area of each tile exceeding 0.18 sqm and not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement to match complete all as specified
Non - skid Ceramic coloured tiles 600x300x 7 to 9 mm thick ,a in floors etc. set in neat cement slurry and pointed in white/ coloured epoxy joint filler 3mm width to match colour of tiles complete all as specified
Glazed ceramic coloured tiles in vertical surface 600x 300x 7 mm thick set in neat cement slurry and pointed in white or colour epoxy joint filler 3mm to match complete all as specified
All as per item No 34 here-in-before but as in skirting complete all as directed.
Machine cut kota stone slab flooring / treads, 15mm thick over CM 1:4, 10mm thk cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror/beeswax polishing in small patches to replace existing broken pieces complete all as specified
All as per item No 36 here-in-before but as in riser of steps in single piece, skirting, dado and pillar.
Beeswax polishing to existing kota stone flooring including preparation of surfaces complete all as specified and directed.
40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floors & pavings complete all as specified
38mm wide glass dividing strips, 3 mm thick inserted in position conform to design complete all as specified
All as per item No 42 here-in-before but from 5th floor to 8th floor
All as per item No 42 here-in-before but from 9th floor upto 12th floor
Rendering 5mm thick in CM 1:3 on brick work or concrete surfaces finished even & smooth without using extra cement as on ceiling complete all as specified.
Preparing newly plastered surfaces of wall & applying two coats of distempering with 1st quality acrylic distemper (ready mixed) , of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resitant primer over one coat of wall care putty (minimum thickness 1mm) and complete all as directed by Engineer-in-Charge.
Preparing newly plastered surfaces of ceiling & applying two coats of distempering with 1st quality acrylic distemper (ready mixed) , of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resitant primer and complete all as directed by Engineer-in-Charge.
Preparation of new plastered surface of wall and applying two coats of Acrylic exterior emulsion paint over a coat of alkali resitant primer using rollers made from foam or synthetic fibres over a coat of external cement putty (minimum thickness 1 mm), to get a smooth and tint free surface, upto 4 storey height complete all as specified and directed by Engineer-in-Charge.
All as per item No 48 here-in-before but from 5th floor to 8th floor
All as per item No 48 here-in-before but from 9th floor upto 12th floor
Complete removal of existing treatment surfaces by brooming down or steel wire brushing; scrapping down smoke , moulds, moss and efflorescent salts and , filling the cracks properly and finally washing with water jet of wall and applying two coat of Acrylic exterior emulsion paint over a coat of alkali resitant primer using rollers made from foam or synthetic fibres over a coat of external cement putty (minimum thickness 1 mm), to get a smooth and tint free surface, upto 4 storey height complete all as specified and directed by Engineer-in-Charge.
All as per item No 51 here-in-before but from 5th floor to 8th floor
All as per item No 51 here-in-before but from 9th floor upto 12th floor
Preperation of surfaces by brooming down or wire brushing; scrapping down smoke , moulds, moss and efflorescent salts and, filling the cracks properly, finally washing with water jet and applying two coat of Acrylic exterior emulsion paint over a coat of alkali resitant primer using rollers made from foam or synthetic fibres, to ceiling surface (chajjah bottom) upto 4 storey height complete all as specified and directed by Engineer-in-Charge. Note : Painting work on wall including preparation of surfaces shall be carried out using hand held mechanical sanding machines only. The work shall be executed through paint manufacturer/ authorized applicator of manufacturer’s only.
All as per item No 54 here-in-before but from 5th floor to 8th floor
All as per item No 54 here-in-before but from 9th floor upto 12th floor
Supply only liquid water proofing compound all as specified
110mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors all as specified
75mm bore PVC (SWR) pipes single socketed in any length fixed to walls with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls / laid in floors all as specified
S&F in repairs Unplasticised PVC pipes 40mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls any type of pipe incl taking up or down steel tubing and connections complete all as specified
CPVC pipes 20mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls complete all as specified
All as per item No 61 here-in-before but 50mm dia.
S&F in repairs Unplasticised PVC pipes 25mm of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls any type of pipe incl taking up or down steel tubing and connections complete all as specified
75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified
110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified
75mm bore PVC (SWR) bends any radius with access door complete all as specified
110mm bore PVC (SWR) bends any radius with access door complete all as specified
110mm bore PVC (SWR) vent cowl complete all as specified
75mm bore PVC (SWR) vent cowl complete all as specified
S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white including 'P' or 'S' trap 100mm dia plastic water closet seat, black or white, closed pattern with flat bottom, seat cover and mild steel chromium plated or aluminised hinging device.(including fixing bolts but excluding flushing cistern and flush pipe) complete all as specified
S&F in repair vitreous China wash basin, white, flat back, size 580x450 excluding taps, waste, chain and plug and porcelain stopper but including brackets and Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm45gms/40mm-60 gms V
Toilet paper holder of CP fixed to walls with chromium plated (CP) brass screws complete all as specified
S & F in repair 75mm PVC (SWR) floor trap, with CP square grating including jointing with solvent cement complete all as specified
S & F in repair 75mm PVC (SWR) multi floor trap, with CP square grating including jointing with solvent cement complete all as specified
S & F in repairs 10 litres capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets & flush pipe complete all as specified
S&F in repairs 32mm bore bottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260 gms/40mm-270 gms) complete all as specified
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified
15mm bore CP fancy type pillar tap for wash hand basin complete all as specified of Make : Jaquar, Cat Part No CON 021KN or equivalent in other approved makes
Supply and fix in repairs, Health faucet (ABS body) with 1mtr long easy flex tube in chrome finish & wall hook complete all as specified of Make : Jaquar, Cat Part No ALD 573 or equivalent in other approved makes
Supply and fix in repairs, Soap dish any type fixed to plug with chromium plated fitted to walls with CP/ Brass screws all as specified of Make : Jaquar, Cat Part No CAN 1131N or equivalent in other approved makes
Supply and fix in repirs, Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified of Make : Jaquar, Cat Part No ACN 1173 or equivalent in other approved makes
Supply and fix in repair tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges all as specified and as directed of Make : Jaquar, Cat Part No CAN-1111SM or equivalent in other approved makes
S & F in repair brass chromium plated shower rose 125 mm dia with 190 mm long arms, swivel joints including fixing to steel/ cpvc pipe or union of Make : Jaquar Cat Part No 495 & 483 or equivalent in other approved makes
S&F in repairs chromium plated bib taps 15mm bore fancy type, screwed down, screwed for iron pipe/ cpvc pipe or for brass ferrule and fixed. Make : Jaquar Cat Part No CON 107KN.
2 way long body CP bib cock quarter turn,15mm with wall flange of Make : Jaquar, Cat Part No CON 041KN or equivalent in other approved makes
S&F in repair 15 mm bore chromium plated fancy type stop cock with long shank and cup(concealed type) of Make : Jaquar, Cat Part No CON 069FTK & ALD 069FT or equivalent in other approved makes
S&F in repairs 15mm bore chromium plated fancy type angle stop valve, single lever with wal flange complete of Make : Jaquar, Cat Part No CON 053KN or equivalent in other approved makes
Chromium plated single lever wall mixture with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges complete all as specifed of Make : Jaquar, Cat Part No CON 273 KNUPR or equivalent in other approved makes
S&F in repair 50 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for CPVC pipes complete all as specified
S & F in repair ball brass valves, high pressure, with polyethene float and flynut complete screwed for CPVC pipe of 50mm dia complete all as specified
4 way PVC gully trap 200mm with PVC grating of approved make complete all as specified
Demolition of precast cement concrete articles and precast concrete block walling built in cement mortar including removal of debris outside MoD land complete all as specified
Precast cement concrete masonry type C4 as per IS-2185 Part-I 2005 with solid blocks having minimum average compressive strength of 4 N/Sqmm and minimum strength of individual unit is 3.2N/Sqmm not exc 10cm in width and setting in CM 1:4 all as specified
75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection, finished even and smooth w/o using extra cement complete all as specified
Reinforced cement concrete 1;2;4 type B1 (using 20 mm graded stone aggregate) for slabs supported on walls , beams and columns, in floors , roofs, landings and in shelves and the like complete with all necessary formwork etc complete all as specified
Reinforced cement concrete type B1 1:2:4 (using 20mm graded aggregate) as in parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates water troughs, hold fast bed block, filling in pressed steel frame, window cills, and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified
Mild steel TMT bars 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified
Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with fair finished flat surfaces complete all as specified
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter to flat surfaces including fair finished surfaces complete all as specified
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors hung as gates, including pintle hinges, stops, hand-made sliding bolts, handles etc.; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified
Mild steel, plain, black sheet 1.6mm thick in wall cladding, steel gates and similar work, cut to size, fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required mild steel gates complete all as specified
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required & hold fasts confirming to Fe-290 Grade-E-165 complete all as specified
6mm dia expansion screws closed eye hook anchors bolts to masonry/ concrete walls all as specified and as directed
4mm thick PVC coated GI wire as in balcony cloth dryer having 2.5mm thick GI wire coated with 1.5mm thick standard PVC coating complete all as specified and as directed
S&F in repairs aluminium single ladder 16' having capacity of carrying load of not less than 120 kg conforming to IS 3696 (Part 2) - 1991 complete.
UPVC white sliding window with flyproof section No AP-102 sliding frame with mesh track, AP-104 sliding window sash, AP-108 sliding window mesh, AP-106 inter lock, AP-110 Glazing bead fitting touch lock complete all as specified. (Note : Glazing and fly proofing shall be measured and paid separately.)
Anodised aluminium frame for cupboards and shutter including joining cleat for fixing & push button handle set with key locking arrangement for shutter as approved by GE etc. complete all as specified
Anodised aluminium Deco grill (DG 101, 7 mm thick) (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved F channel section and fixed to the window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
Standard door eye viewer brass / CP of size 30/16 complete all as specified and directed
Floor door stopper overall length of 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor including vulcanised rubber piece complete all as specified
S&F in repairs, floor door stopper overall length of 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor including vulcanised rubber piece complete all as specified
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete as specified. (Size of the frame is 105x60mm)
All as per item No 114 here-in-before but size of the frame is 125x60mm
2nd class hard wood ,plain,solid,straight chowkats and frames wrought framed rebated on the solid ,rounded or chamffered put together with glue pinned at joints supplied and fixed. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation.
Flush door shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
2nd class hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with 8 panels with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelaminated PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded prelaminated PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelaminated PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side prelaminated PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails feathered at edges, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified
S & F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified
4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane complete all as specified
S & F in repairs 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane complete all as specified
S & F in repairs 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane exc .5 sq. m in each pane complete all as specified
4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane exc .5 sq. m in each pane complete all as specified
4mm thick figured sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane complete all as specified
S & F in repairs 4mm thick figured sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n exc .5 sq. m in each pane, complete all as specified
Butt hinges 125 mm , medium weight, cold rolled and mild steel and fixed complete all as specified
Butt hinges 100mm , medium weight, cold rolled and mild steel and fixed complete all as specified
200 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified
150mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified
300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
150mm aluminium handles, cast type, anodised complete all as specified
100mm aluminium handles, cast type, anodised complete all as specified
Preparation of new or previously untreated wood or wood based surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described applying with two coats of Poly Urathene paint over a coat of Poly Urathene primer complete all as specified
S & F in repair curtain rods fancy type aluminium powder coated drapery rod 25mm dia complete all as specified
S & F in repair fancy type aluminium powder coated bracket and finials suitable for 25mm curtain rods fancy type complete all as specified
Dismantling boarding, any description, fixed in any position with nails complete all as specified
17.5mm thick Solid plain PVC Sheet suitably fixed as in shelves & partitions in cupboards with stainless steel screws & glue complete all as specified & directed.
Pre lalminated high density fibre board, 9mm thick, exterior grade, fixed to aluminium frame etc. complete all as specified
100 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified
S&F in repairs 100 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
MS continuous hinges (Piano hinges), 30mm wide, bright finish or electro galvanised complete all as specified
S&F in repairs MS continuous hinges (Piano hinges), 30mm wide, bright finish or electro galvanised complete all as specified
SS magnetic door catches of locally avaiable best quality with screws complete all as specified
S&F in repairs SS magnetic door catches of locally avaiable best quality with screws complete all as specifieds.
Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specified
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint, treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each complete all as specified
Post construction anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified
Stainless steel Kitchen Plate Rack of size 600 mm x 600 mm x 250 mm of 0.5mm thick fixed with plugs screws, washers and waster, including necessary Chipping/drilling holes to fix on wall suitable size in wall as per IS specification complete all as per specified and directed.
S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washer and waste coupler embedded in cooking platform overall size 600 x 510 mm bowl size 530 mm x 430mm x 190mm complete all as specified
Labour only for taking down and refixing of existing sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washer and waste coupler embedded in cooking platform overall size 600 x 510 mm bowl size 530 mm x 430mm x 190mm complete all as specified
Complete removal of existing treatment and Preparation of old treated surfaces of wall by brooming down or wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling the cracks properly and applying two coat of acrylic distemper over over a coat of cement putty (minimum thickness 1 mm), to get a smooth and tint free surfacea over coat of alkali resitant primer using rollers made from foam or synthetic fibres, to get a smooth and tint free surface complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Preparation of old painted steel & iron surfaces of any description, over 10cm in width or girth,and applying two coat of Poly Urathene paint over a coat of PU primer complete all as specified.
Complete removal of existing treatment on celing surfaces by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling the cracks properlyof ceiling surfaces and applying two coat of acrylic distemper over a coat of alkali resitant primer using rollers made from foam or synthetic fibres to get a smooth and tint free surface complete all as specified and directed by Engineer-in-Charge.
Post construction anti treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors etc in ground floor complete all as specified and as directed by Engineer-in-Charge.
PCC 1:3:6 type C0 using 12.5 mm graded stone aggregate as in filling of pressed steel door frames complete all as specified
75mm long stainless steel handle for loft door shutter complete all as specified
STRUCTURAL REHABILITATION NOTE : Work shall be carried out in two blocks of G+9 configuration. Quantities considered in the BoQ are for the entire floor. Bidder shall quote his rates against the items considering the cost of scaffolding for the entire building. Nothing extra shall be given on this account.
Scaffolding : Providing, erecting and dismantling safe Pipe scaffolding and / or H frame including working platform for external and internal area of building to facilitate all works with proper arrangements etc. complete. Measurement for payment shall be made in square meter of Scaffolding carried out.
Surface Preparation : Labour charges for Chipping off the corrosion damaged areas on the structural members. Clean reinforcement using Reebaklens RR of Fosroc or equivalent and make sure that there are no traces of rust on the surface of existing rebars. Check for the depth of carbonation using the phenolphthalein indicator and make sure that the contaminated concrete is removed completely. Clean the surface and make sure that surface is clean and free from loose particle. The rate shall include all materials, machinery, labour etc. complete.
Surface Preparation for Protective Coating of Wallgaurd: Removal of concrete/mortar spatters or protrusions on the wall surface using power grinding, removal of laitance, curing compounds, oil, grease, wax, algae & fungal growth and dirt/ dust accumulation on the entire wall surface to be coated with protective coating by using high pressure water jetting to achieve a wall Surface Profile compatible with primer coat, making the surface completely dry to receive the coating etc. The rate shall include all materials, machinery, labour etc. complete.
Anchoring column Main Reinforcement : Mark the position of holes to be drilled for anchoring the rebar into the floor/slab and beam. Drill 20mm dia holes in the marked places using rotary hammer drilling machine of reputed make to a depth of 75mm into the floor/slab and beam. Clean the holes neatly and wash the same with jet of water. Allow it to dry and make sure that no fine dust particles are present in the holes. Mix the base and hardener of the polyester resin Make Lockfix-S of M/s Fosroc or equivalent using a spatula and push the same in to the holes with a proper tool so that the bottom most point of the hole receives the material. The filling is to be done for a minimum portion of 1/3rd of the hole depth. Now insert the rebar to be anchored for the provision of main reinforcement, gently and finish the surface around the rebar area using the same material which comes out of the hole excessively. The rate shall include all materials, machinery, labour etc. complete
Anchoring beam Main Reinforcement : Mark the position of holes to be drilled for anchoring the rebar into the floor/slab and column. Drill 20mm dia holes in the marked places using rotary hammer drilling machine of reputed make to a depth of 75mm into the floor/slab and column. Clean the holes neatly and wash the same with jet of water. Allow it to dry and make sure that no fine dust particles are present in the holes. Mix the base and hardener of the polyester resin Make Lockfix-S of M/s Fosroc or equivalent using a spatula and push the same in to the holes with a proper tool so that the bottom most point of the hole receives the material. The filling is to be done for a minimum portion of 1/3rd of the hole depth. Now insert the rebar to be anchored for the provision of main reinforcement, gently and finish the surface around the rebar area using the same material which comes out of the hole excessively. The rate shall include all materials, machinery, labour etc. complete
Additional Reinforcement : Check the diameter of the existing rebars and if the diameter is less than 30% of the original diameter, provide additional reinforcement. Cut 12mm dia bars as main reinforcement to the required length with proper development length. Tie them to the prefixed shear connectors so that the additional rebar acts monolithically with the existing ones and core concrete. In the case of the shear reinforcement also, if the diameter of the rebars is reduced, provide 8mm dia stirrups in the form of 2 "U" shaped bars. Tie them properly so that it has a tight contact with the main bars. The rate shall include all materials, machinery, labour etc. complete.
Shear Connectors : Drilling 12mm dia holes up to a depth of 75mm maximum and fixing 8mm dia L shaped anchor rods as shear connectors at every 300mm c/c on the surfaces of the columns/beams or any other structural member as the case may be. Clean the same using water and make sure that there are no fine particles present in the hole. Mix the base and hardener of the polyester resin Make Lockfix-S of M/s Fosroc or equivalent with the spatula thoroughly. Fill the drilled and cleaned holes to a minimum depth of 1/3rd of the hole with the prepared polyester resin. Make sure that the resin has reached till the end of the hole. At this stage push the shear connector gently in to the hole and finish the excess resin which comes out of the hole and allow the shear connectors not to be disturbed for minimum 20 minutes - complete. The rate shall include all materials, machinery, labour etc. complete.
Anti-corrosive Coating : Clean the rebars using the rust remover if there exists any rust, otherwise clean the rebar free of foreign material. Mix the base and hardener of the anti-corrosive coating like Nitozinc Primer of Fosroc or equivalent mechanically using a slow speed heavy duty drilling machine fitted with mixing paddle. Apply the mixed materials to the cleaned rebar and allow it to dry complete. The rate shall include necessary scaffolding and platform and cost of all the operations and etc complete. The rate shall include all materials, machinery, labour etc. complete.
Epoxy Jointing Compound : Clean the concrete surface, remove the loose particle if any. Make sure that the form work is ready for positioning. Mix the base and hardener of the epoxy resin jointing compound and apply the same to the prepared surface. Care should be taken that the micro concrete needs to be done within 5 hours maximum from the time of application of epoxy jointing compound Nitobond EP of Fosroc or equivalent. The materials should have the fallowing properties: Specific gravity of which is 1.15 to 1.2 gm/cc, Compressive Strength (BS 6319 Pt 2) is 50MPa (@ 7day), Flexural Strength (BS 6319 Pt 3) is 35MPa (@ 7day), Shear Strength (BS 6319 Pt 4) is 10MPa (@ 7day). The rate shall include all materials, machinery, labour etc. complete.
High Strength Polymer Mortar (SP40) : Renderoc SP40 75 mm thick of Fosroc or equivalent, ready to use blend of dry powders which is formulated for application, repair mortar suitable for most structural and load bearing repairs as per manufacture specification. The rate shall include all materials, machinery, labour etc. complete.
Polymer Modified Mortar : Wet the surface with potable water and make sure that the surface is kept moist so that the water cement ratio in the polymer modified mortar 40 mm thick is maintained. Supply and application of Nitobond SBR or equivalent as per manufacture specification. The rate shall include all materials, machinery, labour etc. complete.
Curing Compound : Immediately after striking the form work or after completion of the repair works, the surface should be sprayed water once and followed by application of membrane based curing compound like Concure WB of Fosroc or equivalent diluted with water in the ratio of 1: 1 as a curing membrane - Complete. The specific Gravity of which is 1.025 to 1.04 gm/cc and Slant Shear (BS 6319) is 20 MPa. The rate shall include all materials, machinery, labour etc. complete.
Water Proofing with Brushbond : All the surfaces which are to receive the waterproofing coating like Brushbond, must be free from dirt or any other form of foreign matter which might affect adhesion. Acid wash and water wash the surface and allow it to surface dry condition. Mix the part A and part B of the polymer modified cementitious coating mechanically using an electrically operated drilling machine fitted with mix paddle. Apply the same in two coats over the prepared surface one after the other dries up with a minimum interval of 4 hours between the coats. Providing pressure grouting in all the vertical and horizontal joint including the suspected areas. The rate shall include all materials, machinery, labour etc. complete. Note : 10 years Guarantee certificate to be submitted by contractor.
Protective Plastering : Prepare cement sand mortar in the ratio 1:4 with waterproofing liquid (Conplast X421 IC manufactured by M/s Fosroc Chemicals or equivalent) as per the dosage of the manufacturer and apply the same as protective screed to prevent mechanical damage while laying the weathering course, tiles etc.
Protective Coating Wall guard : Clean the surface with wire brush and remove all dirt and dust. The surface should also be completely dry. The contents of Nitocote Wallguard shall be thoroughly stirred for atleast 2 minutes using a slow speed (300 - 400 RPM) drilling machine attached with a mixing paddle. Apply Nitocote Wallguard with a nylon brush, or a felt roller, to the primed substrate. Allow Nitocote Wallguard first coat to dry for 5-6 hrs at 300 C and then apply the second coat. Nitocote Wallguard shall be applied at theoretical application rate 3 to 3.5 m2/ litres for 2 coats. The rate shall include all materials, machinery, labour etc. complete.
INTERNAL ELECTRIC SUPPLY
Taking down copper/aluminium point wiring from(light,fan, socket or power) complete including fixture and fitting such as switches, ceiling roses,pendants, regulators, sockets etc. removing meterials to store for keeping in safe custody or for taking cerdit (credit for above items should be made as per conditions seperatly) and making good distrurbed surface of wall, floors etc.
Taking down old unserviceable single phase sub main wiring of any size including making good the disturbed surface of wall/ floors matching the existing surface of wall or floors.
Taking down old unserviceable MCB DB TPN/ SPN with MCBs including making good the disturbed surface of wall/ floors matching the existing surface of wall or floors.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked including medium grade PVC Conduit of suitable dia with accessories open on wall/roof/floor etc, ISI marked including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S.H. cable as earth continuity conductor to common earth and connecting to earth dolly complete for One light/fan/exhaust fan point controlled by one switch complete all as specified.
All as per item No 183 here-in-before but for One 5 Amps socket outlet point on same board alongwith other switch.
All as per item No 183 here-in-before but for One 5 Amps socket outlet point on independent board controlled by one switch.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked including medium grade PVC Conduit of suitable dia with accessories open on wall/roof/floor etc, ISI marked including PVC insulated multi-stranded copper conductor 2.5 Sqmm nominal cross sectional area single core F.R.L.S.H. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn in existing concealed/open rigid non metallic PVC conduit medium grade with 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded copper conductor for phase and neutral alongwith 1.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper conductor for earth wire complete for One light/fan/exhaust fan point/ point controlled by one switch complete all as specified.
All as per item No 187 here-in-before but for one Exhaust Fan controlled by one switch
All as per item No 187 here-in-before but for One fan point by one switch and regulator
All as per item No 187 here-in-before but for One bell point controlled by one switch
All as per item No 187 here-in-before but for One 5 Amps socket outlet point on same board alongwith other switch.
All as per item No 187 here-in-before but for One 5 Amps socket outlet point on independent board controlled by one switch.
All as per item No 187 here-in-before but for one light point controlled by two way switch
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn in existing concealed/open rigid non metallic PVC conduit medium grade with 2.5 Sqmm PVC insulated unsheathed FRLSH multistranded copper conductor for phase and neutral alongwith 2.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper conductor for earth wire complete for One light/fan/exhaust fan point/ point controlled by one switch complete all as specified.
Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Modular switch 1 way 6A,1 module, all as specified and directed.
Modular switch 1 way 16A,1 module, all as specified and directed.
Modular switch 2 way 6A 1 module all as specified and directed.
Socket, 6A - 3 pin combined 2 module all as specified and directed.
Socket 6A/16A - 3 pin combined 2 module all as specified and directed.
ceiling rose three terminals 230 V (ISI marked) surface bakelite comlete all as specified and directed.
Modular Bell push 6A 1 module all as specified and directed.
Buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed.
Modular metal flush box of 1/2 module complete all as specified (Note : Rate deemed to be inclusive of rate for cutting/chipping to existing wall for fixing the modular frames and making good the surfaces.)
All as per item No 205 here-in-before but Modular metal flush box of 3 module
All as per item No 205 here-in-before but Modular metal flush box of 4 module
All as per item No 205 here-in-before but Modular metal flush box of 6/8 module
Modular white cover plate with frame 1 Module complete all as specified
Modular white cover plate with frame 2 Module complete all as specified
Modular white cover plate with frame 3 Module complete all as specified
Modular white cover plate with frame 4 Module complete all as specified
Modular white cover plate with frame 6 Module complete all as specified
Modular white cover plate with frame 8 Module complete all as specified
LED Tube Lights of 20W(+/- 10% Tolerance) with PVC body linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, powerfactor>0.95,THD</=10%, rated life of 50,000 hours, system efficacy greater than or equal to 125 lm/w, including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 2 Year Warranty for the fixture should be provided by the contractor). Note: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required at site is deemed to be included in the rate ).
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified
Supply and fix in renewal of Decorative wall light fixture made up of Polycarbonate 9 watts with IP 20 protection comprises of polycarbonate housing, high efficiency diffuser polycarbonate cover,Lamp 9 watts warm white, etc and all accessories pre-wired including connecting up complete all as directed.
Labour for removing and refixing of existing wall mounted light fittings back in position all as specified and as directed.
LED bulb of 9 Watts 6500 K suitable for fixing in lamp holder all as specified and as directed
Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and directed.
Modular type Fan step regulator, 120W - 2 module all as specified and as directed
Disconnection of electrical wire from exhaust fan any type / size and make, dismantling the exhaust fan, wahsing and removing of old lubricating substance from bearing/bush using Kerosine oil, painting ,carrying out fresh lubrication using grease and to make the exhaust noise free for smooth functioning, including replacement of worn out/unserviceable spares as required, replacement of PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired exhaust fan and testing to the entire satisfication of engineer in charge and hanging at position with nut , bolts washers etc, connection with point wiring & testing complete. (Replacement of Spares flexible wire etc/rewinding of exhaust fan/shall be measured and paid seperately under respective item for material and labour cost .)
Material and labour for rewinding of ceiling fan 1200/1400 MM sweep by dismantling of fan motor, cutting and removing of burnt windings, cleaning the motor slots, rewinding the motor with supper enameled copper wire of appropriate gauge, provision of insulation paper, applying of varnish, heating / baking the motor to acheive the proper insulation resistance and reassembling & renewal of bearings including taking down and refixing the fan in original location complete all as directed.
Preparation for old surface of LT panels and busbar trunk by applying two coats of Eppoxy painted siemens grey any size of panel all as specified and directed
SPN sheet metal enclosure Double door flush type 8 way distribution board with 100 Amps rated bus bar to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
TPN Vertical distribution board factory made Double door flush type all as per IS 8623 made from sheet metal duly powder coated 4 way 200 Amps rated bus bar to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
TPN MCB, FP 63 Amps,10 kA including taking down existing all as specified and as directed
TP MCB, 40 Amps,10 kA including taking down existing all as specified and as directed
SPN distribution board factory made Double door flush type all as per IS 8623 made from sheet metal duly powder coated 4 way to be fixed flush with wall complete with all accessories all as specified and directed by Engineer-in-Charge.
RCBO of current rating 32 A ,30 ma sensitivity , short circuit current rating 6 KA Double pole all as specified and directed by Engineer-in-Charge.
MCB SPN 40 Amp, 240 volts of 10 KA rupturing capacity, B-curve type as out going complete all as specified and as directed.
MCB SP 6 to 32 Amp, 240 volts of 10 KA rupturing capacity, C-curve type as out going complete all as specified and as directed.
MCCB, FP 63 Amps,25kA with rotary type handle and necessary arrangements for fixing in the bus bar trunking system including taking down existing all as specified and as directed
MCCB, FP 160 Amps,36kA with rotary type handle and necessary arrangements for fixing in the bus bar trunking system all as specified and as directed
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded FRLSH copper conductor of size 6 Sq mm incl provn of PVC conduit fixed on surface and accessories and 6 sq mm FRLSH copper conductor cable as earth continuity conductor and connected to common earth dolly. Note : 03 Runs of 6 Sqmm multistranded copper conductor PVC insulated unsheathed and one run of PVC conduit medium grade shall be measured as one unit.
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded FRLSH copper conductor of size 6 Sq mm drawn through existing conduit and accessories and 6 sq mm FRLSH copper conductor cable as earth continuity conductor and connected to common earth dolly. Note : 03 Runs of 6 Sqmm multistranded copper conductor PVC insulated unsheathed shall be measured as one unit.
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded FRLSH copper conductor of size 4 Sq mm drawn through existing conduit and accessories and 4 sq mm FRLSH copper conductor cable as earth continuity conductor and connected to common earth dolly. Note : 03 Runs of 4 Sqmm multistranded copper conductor PVC insulated unsheathed shall be measured as one unit.
Earthing complete with GI earth plate electrode 600 x 600 x 6mm size burried directly in ground earth pit not less than 2.25Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to GI wire 4 mm as earth lead by means of bolts ,nuts ,checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specfied or indicated including testing on completion with excavation earth pit, PCCcover watering pipe etc., including taking down of old earth plate all as specified and directed by Engineer-in-Charge.
Sub main wiring with 2 single core PVC insulated unsheathed 1100 Volt grade multistranded FRLSH copper conductor of size 2.5 Sq mm drawn through PVC conduit fixed on surface and accessories and 2.5 sq mm FRLSH copper conductor cable as earth continuity conductor and connected to common earth dolly. Note : 03 Runs of 2.5 Sqmm multistranded copper conductor PVC insulated unsheathed and one run of PVC conduit medium grade shall be measured as one unit.
M&L repair to unserviceable storage water heaters (Geyser) of 25 capacity and taking down, replacing defective parts with new parts and refixing after clearing the defects and make it operational complete all as specified and directed. Note: (i) Replacement of parts will be measured and paid as supply only seperately. (ii) The cost of labour and consumables required for replacement of parts, arc or gas welding for tank leakages shall deem to include in unit rate quoted by the contractor.
Supply only thermostat suitable for 25 ltr capacity Geyser complete all as specified
Supply only geyser inlet and outlet assembly for 25 liters capacity geyser compete incl all fixing accessories complete all as specified
Supply only pressure release valve suitable for 25 ltr capacity Geyser 8 bar complete all as specified
Supply only heating element 1.5KW/2KW suitable for 25 Itr capacity Geyser as per site requirements compatible with any brand of geyser complete all as specified
Supply only mounting bracket assy suitable for 25 ltr capacity Geyser complete all as specified
Supply only SS inner tank suitable for 25 ltr capacity Geyser complete all as specified
Supply only 3 core 2.5 sqmm PVC flexible copper condutor suitable for Geyser complete all as specified
Supply only connection pipe 15mm dia 450mm long for hot/cold water both end connected with screwed brass nut complete all as specified
Supply only neon indicating lamp suitable for 25/50 ltr capacity complete all as specified
Building security light luminaries 25 W LED 6 K environment friendly long life versatile pressure die cast aluminium IP 65 luminaire with high power LEDs light source and electronic driver complete watts including GI brackets GI tube of suitable dia and mounting accessories all as specified a
Rewinding of exhaust fan 230 mm sweep 230 volts , of any make/type a with super enamelled copper wire of appropriate gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator/rotor, connection & testing complete. Note : exhaust fan before fix at site RPM should be checked and match as per manufactures specification till entire satification of Engineer-in-Charge
FIRE FIGHTING
Supplying, fixing, testing and commissioning of Gunmetal Ball valve 25mm dia PN 1.6 with rubber insertion nuts, Steel Ball with hand lever operated screwed end conforming to IS 554 including taking down old material all as specified and directed by the Engineer in Charge.
Supplying and fixing of weather proof Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with doubledoor with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard and looking arrangements suitable for accommodate internal hydrant with 2 Nos 15 Mtrs long hose pipe, 2 No. branch pipe, fittings etc.The cabinet shall be painted with one coat of primer and 2 coatts of synthetic enamel paint of post office red externally and white internally and shall be suitably mounted on concrete bases including taking down old material all as specified and directed by the Engineer in Charge.
Supplying, fixing, in repair testing and commissioning 63mm dia 15 mtr long Hose Pipe (Hose Pipe shall be of synthetic fibre) confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and directed
Supply, installation in repair stainless steel 63mm dia short Branch Pipe with 15mm bore nozzle of gunmetal having screw threaded and hexagonal head conforming to IS903 with ISI mark
Supplying, fixing in repair First Aid Hose Reel wall mounting swinging type complete with drum, bracket, gate valve/ stop cock and 19mm dia 30mtr long high pressure hose reel tubing of Thermoplast Type II hose conforming to IS12585 with ISI mark with gunmetal shutt off nozzle with 5mm orifice
Supplying, fixing in repair stainless steel Fire Brigade Inlet 4 way connection for connecting to external fire hydrant ring main consisting of four nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories.
Supplying, fixing, in repair testing and commissioning of Industrial type Pressure Switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc complete as required
Supply only in repair Pressure Gauge 100mm dia with ball valve of pressure of 14Kg/Sqcm , 3/8" BSP bottom entry,weather proof with stainless steel internals,siphon tube and ball valve including fittings complete all as specified and directed.
Supply , laying, testing and commissioning of 'C' class heavy duty 100 mm dia MS pipe conforming to IS:1239 I/c fittings like elbows, tees, flanges, tapers, nuts, bolts,gaskets etc fixing the pipe on the wall/ ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete incl taking down old unsv pipe as required.
Supplying, fixing,in repair horizontal type Cast Iron Dual plate Non-return valve 100 bore of approved quality conforming to API-594 standards with nuts, Bolts, Washers etc complete as required.
Supply & fix in repair yard hydrant post / stand post 80mm Dia GI / MS both flanged type 1.5mtr height incl taking down old unsv complete
Supply & fix in repair air release valve 50mm dia suitable for fire fighting wet raiser system incl taking down old unsv complete
M&L for scrubbing of existing paint from all mettalic surfaces of existing fire fighting system per building and applying two coats of scarlett red synthetic enamelled paint over a coat of mettalic primer complete
Supplying, fixing, in repair Fire Hydrant Landing Valve type A (Single Head Outlet) type with SS female coupling valve conforming to IS:5290-1993 having 80mm dia inlet with PVC Cap and locking mechanism.
Supply and fix Fire Alarm sounders / Sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 500 meter range including taking down old material all as specified and directed by the Engineer in Charge.
Supply and fix Addressable manual call point resettable type with relay module with hammer including taking down old material complete all as specified and directed by the Engineer in Charge.
Supply and fix 2 core 1.5 sqmm armoured FR LS copper condutor suitable for fire Alarm including taking down old material complete all as specified and directed by the Engineer in Charge.
Supply and fix in repairFire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed by the Engineer in Charge.
Supply and fix in repair 4 Watt ceiling Speaker with box complete all as specified and directed by the Engineer in Charge. Make : Ahuja or equivalent make as approved by GE.
Supply and fix in repair 250 Watt Amplifier complete all as specified and directed by the Engineer in Charge. Make : Ahuja or equivalent make as approved by GE.
M&L for Servicing of induction motor 10 HP coupled with pump complete including re-winding with same gauge of copper wire as per OEM recommendation inl greasing replacement of wornout rubber packing, bearing wornout nuts and washers etc and complete
Supply and fix three phase DOL starter 415V suitable for 10 HP motor provided with protection degree IP54 complete all as specified and directed
Detectors Complying with and type certified to EN - 45 Addressable type heat and smoke combination detector Photoelectric /Optical with base with self built intelligence as per IS:11360 including taking down old material complete all as specified and directed
Supply and Fix in wall mounted LED emergency exit signage luminarie lit up using regular mains supply and with a unique rechargable Ni-Cd battery capable of emergency backup upto 05 hours complete all as specified and directed
LIGHTNING PROTECTION
Taking down old GI/Al strip any size with connecting accessories like insulator, air termination rod screws etc complete all as per direction of Engr - in - charge
Air termination, single pointed, aluminium rod 12 mm dia and 300 mm long complete all as specified
Galvanised iron strip 32 x 6 mm buried in ground /fixed on wall complete all as specified.
Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified.
Refixing of aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. by painting with corrosive resistant paint for roof conductors and down conductors above ground complete all as specified. NOTE : Strip retrieved from item No 279 here-in-before will be reused.
Llight grade galvanised iron pipe 40mm bore with all fitting and fixed to walls/laid in floors/trench complete including taking down old material.
Light grade galvanised iron pipe 20mm bore with all fitting and fixed to walls/laid in floors/trench complete including taking down old material.
Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 03 Nos, 8 mm dia 25 mm long hex head screw in smc enclosure/junction box including taking down old material complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI strip 32x6mm mm by means of bolts, nuts , check nuts and washers of GI and GI tubing 40 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I including taking down old materials of earthing all as specified and directed by the Engineer in Charge. NOTE : Quantity is inclusive of External Electric Supply.
AVIATION OBSTRUCTION LIGHT
Hot press moulded SMC enclosure/junction box, 200 mm x 140 mm x 95 mm size, door fixed with hinge on one side for fixing of test terminal block including taking down old junction box/ enclosure.
Integral LED aviation obstruction light comprising of aluminium housing with polycarbonate enclosure Make/ model- Bajaj BGAV 302 LED or equivalent in other approved makes, along with programmable lux base timer switch of make Nature TS/Kakatiya/ABB and one MCB SP 32A, including one contactor of 04 pole 25 Amps AC, 240 volts of 06 Amps fixed in a wall bracket enclosure including taking down old U/S material.
Supply, laying testing cable XLPE insulated, screened, PVC RM bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6.0 sqmm 2 core including taking down old unserviceable material
EXTERNAL WATER SUPPLY
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40 mm complete all as specified and directed.
CPVC pipes, SDR 11, 50 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adoptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc
S&F in repair ball valves of 50 mm dia with rotating spindle complete all as specified.
Supply and fix in repairs Ball brass valves, high pressure, 50 mm bore with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified
EXTERNAL ELECTRIC SUPPLY
Excavation in trenches n exc 1.5m wide and n exc 1.5m deep for laying /removing of cable/ erection of poles in Soft loose soil all as specified
Supply and filling riddled soil to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified. Note : 1. Earth shall be obtained from outside MoD land. 2. Punned thickness shall be measured and paid.
Supply and lay sub class "B" burnt bricks of size 23x11.5x7.5 cm, as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
Returning and filling in of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete all as specified.
GI pipe, light grade of dia 50 mm, as in cable protection complete all as specified.
XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 150 Sqmm, 3.5 core, 1100 volt grade , Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. Note : Necessary earth works sand cushioning cable protection cover GI pipe etc will be measured and paid separately under relevent items.
All as per item No 304 here-in-before but of cross sectional area 50 Sqmm, 3.5 core
MCCB, FP 250 Amps,36kA with rotary type handle and necessary arrangements for fixing in the bus bar trunking system all as specified
Synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 K for electrical purpose as per IS15652-2006 (superseding IS 5424)suitable for electrical shock safety including taking down of existing mat complete all as specified and as directed.
Painting on old surfaces chequred plate/iron structure by spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats of paints all as specified and as directed
Fabrication by cutting to required sizes as trench covers, Mild steel plates, chequered, 3/5 mm thick or over in thickness in available sizes Fe 410-W(Gde E-250) quality B including taking down of existing item all as specified and as directed
Cutting of road /concrete portion including excavation , returning, filling in,spreading levelling,well ramming in layers,soling with broken boulders / stones and aggregate to match with existing surface complete all as specified and as directed by the Engineer-in- Charge.
Supply, install and connection LT outdoor loop-in loop-out terminal box with sloping canopy of size 600x450x300mm made out of 3.15mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, front and rear hinged doors mounted on 25x25x4mm MS angle iron frame 60cms height, erected in ground with PCC foundation (1:4:8) type D-2 (using 40mm graded stone aggregate) including Supply and fix in repair insulated aluminium bus bar of current carrying capacity 400 Amps for 3 phase and neutral respectively mounted on insulators and terminating with suitable cable with glands including taking down old terminal boxes complete all as specified and as directed. Note : Rate deemed to be inclusive of rate of foundation and any excavation works required at site
FUTURE ONE FACILITY MANAGEMENT
Star Construction Co.
Powertech Engineers
ROY CONSTRUCTION CO
M.J.JOY AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid