Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.2 L+₹1.1 L (13.1%)Rejected-Finance F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | L2 | Rejected-Finance 922720.00 | |
| 3 | L3₹10.6 L+₹2.4 L (29.6%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance 1056620.00 | |
| 4 | Rejected-Technical 104 RASTRA GURU AVENUE DUM DUM NAGERBAZAR KOLKATA 700028 | KOLKATA | KOLKATA | WEST BENGAL | 700028 | - | Rejected-Technical Mismatch of Y Affidavit |
Tender Value
₹9.3 L
EMD Value
₹18,628
Closing Date
28 Jun 2022, 3:00 pmClosed
Executive Engineer PWD Bidhannagar Electrical Divi
Room No 108, Purta Bhavan, Salt Lake, Kol-91
Revamping of AC installation in room no 328 at the WB National University of Juridical Science Sector III Salt Lake Kolkata 700098
2022_WBPWD_384490_1
WBPWD/EE/BED/e-NIQ-10/2022_23
Open Tender
ELECTRICAL WORKS M/R
Item Rate
30 days
Juridacal Science
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,628
Yes
Room No 108, Purta Bhavan, Salt Lake, Kol-91
18 Jul 2022
9 Jun 2022
30 Jun 2022
14 Jun 2022
28 Jun 2022
21 Jun 2022
17 Jun 2022
Amount
Dismantling of unservicable AC equipment and allied accessories.
Supply & Delivery of Ceiling suspended ductable type split airconditioners having Microprocessor based control system and the following specification. Capacity-8.5 Tonnage (upto +1 TR acceptable) Rated Cooling Capacity -102000 BTU/Hr No. of IDU-1 No Air-flow/IDU-3400 CFM No of ODU-1 or 2 Nos Compressor-1/2 No Scroll Compressor Refrigerent-R410A Condenser & Cooling Coil: Copper coil Power Supply: 415v, 50Hz,3 Ph AC (with applicable tolarance) [Make-Carrier/Voltas/Blue Star/Mitsubishi Electric/Hitachi/DIAKIN]
Installation, Testing and Commisioning charges for the following ductable split air conditioner (both indoor and outdoor unit) by making suitable scaffolding arrangement as per site condition and including nitrogen flashing, leak testing & vacuuming, gas charging etc as per direction of E.I.C of the following 8.5 TR
Supply, Installation, Testing and Commisioning of Copper Refrigeration pipe line for Liquid Line suitable for the above ductable units with supports & brackets (as per direction of E.I.C.) including 9 mm thick nitrile rubber insulation with proper tapping and mending good damages to original finish. Make of Cu Pipe - Rajco / Ryoku / Mandev/ Nippon Make of Insulation - Suprime / Accroflex / Armacell. 12.7 (1/2") mm dia with 0.6 mm thick
Supply, Installation, Testing and Commisioning of Copper Refrigeration pipe line for Suction Line suitable for the above ductable unit with proper supports & brackets (per direction of E.I.C.) including 9 mm thick nitrile rubber insulation with proper tapping and mending good damages to original finish. Make of Cu Pipe - Rajco / Ryoku/ Mandev/Nippon Make of Insulation - Supreme / Accroflex / Armacell. 28.6 (1 1/8")mm Dia with 0.6 mm thick
Supply and laying of 1.1 KV grade copper round Cable of the following sizes from IDU Unit to ODU unit for the above mentioned AC units (Make: Polycab/Havells/Gloster/Finolex/RR Cable) 3 core 4 sqmm
3 core 1.5 sqmm
Finishing the end of XLPE/ PVC cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials of following size. 3 core 4 sqmm
3 core 1.5 sqmm
Supply & Installation of PVC/HDPE Drain Pipe Line (25 mm/32 mm OD, HD 1 mm thick )of the following size with 6 mm nitrile rubber insulation and with proper supports & brackets as per direction of E.I.C. (Make: Supreme/Oriplast) 25 mm dia OD
32 mm dia OD
Supplying, fabrication & fixing s. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame/platform for installation of outdoor unit of above mentioned AC machines incl. drilling 2 nos holes in each channel, cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm and supporting angle of 50mm x50mm x 6mm in each platform in the outer edge for transmitting the load centrally through 2 nos (50 mm x50mm x6 mm) angle inserted into the existing wall incl. fiber sheet shade as per Direction of E.I.C. The entire structure must be safe to carry out maintenance of ODU, as per Direction of E.I.C.
Supply & fixing of fire retardant nonporous double layer flexible connection (CANVAS) between each indoor unit and duct as per direction of E.I.C.
Supplying & fixing of powder coated extruded aluminium Air diffuser without aluminium volume control dampers as per specifications. Make - Systemair / Premire / Caryaire / Airmaster
Supplying & fixing of powder coated extruded aluminium Air diffuser with aluminium volume control dampers as per specifications. Make - Systemair / Premire / Caryaire / Airmaster
Air Distribution System Supply, fabrication and installation of GSS sheet metal ducts (rectangular/round) and plenum chamber complete with necessary MS supports, hangers anchor bolts, supply air collars, vanes, splitters dampers duly painted and as per specification for Air Conditioned Areas. 24 SWG
Supply & fixing of 19 mm thick class O fire retardant Nitrile rubber Aluminiun foil face thermal insulation on duct with adhesive for nitrile rubber. The joints shall be sealed with 50mm wide & 3mm thick self adhesive nitrile rubber tape insulation complete as per direction of EIC. (Make-accroflex, K-flex./A-flex/Armacell) as per direction EIC.
Supply & fixing acoustic lining of supply air duct and plenum with 25mm thick resin bonded glass wool having 1.25 mm thick, density 32Kg/m² with 25mm x25mm GI section at 600 mm centre to centre to centre with reinforced plastic tissul paper and 0.5mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc completed as per direction of EIC. (Make- Accroflex,K-flex.)
Supply & Fixing of 22 G GI aerofoil blades type Duct Volume Control Dampers complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Supply and Installation of fresh air arrangements with volume control damper, bird's screen etc complete as required.
Less cost of unservicable dismantled materials of Item Sl. No. 1. (Bidders are requested to quote their buy back rates only without possitve or negative sign in the rate column. Total amount of this item will be automatically be negative by built in formula).
(Note :- Rate should be quoted inclusive of all taxes and duties including G.S.T.)
P. M. COOLING AND ENGINEERING CO
SKY DECORATIONS PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .