GE (AF) TECH AREA MAHARAJPUR
GE (AF) TECH AREA MAHARAJPUR
OUTSOURCING OF SERVICES FOR OPERATION OF CERTAIN E/M INSTALLATION IN TECH AREA AT AF STN MAHARAJPUR
2020_MES_324923_1
8900/1223/MJR/E8
Open Tender
Miscellaneous Services
Item Rate
335 days
GE (AF) TECH AREA MAHARAJPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) TECH AREA MAHARAJPUR
₹73,140
Yes
23 Mar 2020
13 Feb 2020
11 Mar 2020
13 Feb 2020
9 Mar 2020
27 Feb 2020
Amount
Outsourcing of services for operation of central AC plants and DG sets round the clock using one operator in each shift (i.e 24 Hours in three shifts each shift of 8 hours) with the operation of following plants/equipments at 25 MMPU and 24 MMPU (old) AF Stn Maharajpur complete all as specified and directed:- Central AC Plant Chiller type of Capacity 2 x 50TR working and 01 x 50 TR Standby at 25 MMPU:- (a) (i) 50 TR capacity chiller unit complete comprising of scroll compressors with Air cooled condensors etc including LT panel with starters- 3 Sets. (ii) Chilled water circulating monoblock Pump with electric motor 7.5 HP-03 Nos. (iii) Hot water genertor 120 KW-01 No. (iv) Hot water pump set 5 HP-02 Nos. (v) Air handling unit 20000 CFM-02 Nos. (vi) LT control panel comprising of starters of all connected equipments-04 Nos (b) DG Set 63 KVA with AMF panel & LT panel - 1set
Outsourcing of services for operation of central AC plants and DG sets round the clock using one operator in each shift (i.e 24 Hours in three shifts each shift of 8 hours) with the operation of following plants/equipments at RDM and MIRAGE 2000 AF Stn Maharajpur complete all as specified and directed:- Central AC Plant Chiller type of Capacity 2 x 50 TR working and 01 x 50 TR Standby at RDM :- (a) (i) 50 TR capacity chiller unit complete comprising of scroll compressors with Air cooled condensors etc including LT panel with starters- 3 Sets. (ii) Chilled water circulating monoblock Pump with electric motor 7.5 HP-03 Nos. (iii) Hot water genertor 160 KW-01 No. (iv) Hot water pump set 5 HP-02 Nos. (v) Air handling unit 20000 CFM-02 Nos. (vi) LT control panel comprising of starters of all connected equipments-04 Nos (b) DG Set 100 KVA with AMF panel & LT panel - 1set (c) Central AC Plant Chiller type of Capacity 2 x 11 TR working and 01 x 11 TR Standby at Mirage 2000
Outsourcing of Services for operation of Central AC Plant and DG Set Installation round the clock using one operator in each shift (i.e. 24 Hours in three shifts each shift of 8 hours) with following plants / equipments at MMS, at AF Stn Maharajpur complete all as specified and directed :- (A) Central AC Plant DX type of Capacity 2 x 35 TR working and 01 x 35 TR Standby at MMS :- (i) 35 TR capacity condensing unit complete comprising of compressor with induction motor & condensor -03 set.(ii) Condenser water circulating pump with electric motor - 02 Sets (iii) FRP induced draft cooling tower of 100% capacity - 01 Set (iv) Air Handling unit complete of 28000 CFM capacity electric blower motor – 01 No. (v) Humidification pump complete driven by electric motor & starter- 01 No (vi) LT Control planel comprising starters of all connected equipments of AC plants - 01 Set (vii) Standby DG Set of 250 KVA capacity including control panel- 01 Sets.(viii) Standby DG Set of 125 KVA capacity including control panel- 01 Sets Note for Item No 1 to 3 :- (i) Payment shall be made as per minimum labour wages fixed by State Govt/ Central Govt whichever is higher. (ii) The quoted rate of bidder shall not be less than minimum fair wages fixed by State Govt/ Central Govt including GST, LWC &n ESIC in any case otherwise such bid shall be rejected and shall not be considered for acceptance. (iii) Contractor shall maintain adequate temperature and relative humidity as per design parameter of each AC Plant. (iv) Cleaning of complete AC plant, Pre metallic filters, cooling towers & surrounding area is also contractor`s responsibility. (v) Checking of electric connections of all components, refrigerant gas leakage, rectification and recharge of refrigerant gas, checking of complete AC plant & checking of LP, HP & Oil pressure.
(vi) Replacement of minor parts such as Flair nuts, LT cable joints with suitable size lugs are contractor’s responsibility. (vii) All operator should have minimum 03 years experience or shall be ITI trained. (viii) Fuel, refrigerant gas and lubricants shall be issued by the department from AGE E/M (AF) Tech Area store yard under Schedule ‘B’ free for filling at Maharajpur and it will be the contractors responsibilities for filling of oil / lubricant in to fuel tank of DG sets all as specified & directed. (ix) Empty containers shall be returned by the contractor to the MES store at Maharajpur. (x) All operator will wear proper uniform as approved by GE and shall be provided by contractor. (xi) Contractor will employ additional employ for rest/leave period. (xii) For panel recovery on account of non-operation of installation/absent of operators from duty etc respective clause of particular specifications shall be applicable. (xiii) Proper handing / taking over of operator to be done and operator should not leave the plant till arrival of next operator. (xiv) Stationery for maintenance of installation record shall be contractors responsibility (Daily Log Sheet, Attendance register, Wages Register, (xv) Insurance of all operator shall be contractors responsibility. Deptt will not be responsible for any accident. (xvi) Contractor submitt the nominal roll of persons to be employed alongwith qualification/experience certificates, Police verification identification certificate to Engineer-in-Charge before employed the staff. (xvii) The contractor shall operate the DG sets and connected panels for proper functioning of AC Plant at the time of power failure and to maintain the system functional as per users requirement.
LUCKY SALES CORPORATION
M/S AUTOMATION AND SWITCHGEAR CONTROL
lodhi builders
M/S YOGANSH CONSTRUCTION CO.
Kumar Sales Corporation
M/s Pal Construction
M/s Mahesh Engineering Works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .