Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
PROVN OF HIGH MAST AND SECURITY LIGHTS, SPL REPAIR / REPLACEMENT TO OLD U/S LT PANELS, PROVN OF CENTRFUGAL PUMP AT BOOSTER PUMP HOUSE AND CONNECTED ITEMS OF WORKS AT 7A MAP ACCN AT MIL STN PITHORAGARH.
2024_MES_664810_1
8624/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Pithoragarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹64,000
Yes
19 Nov 2024
9 Jul 2024
11 Sept 2024
9 Jul 2024
4 Sept 2024
24 Jul 2024
10 Jul 2024 - 17 Jul 2024
Amount
DESCRIPTION OF ITEMS
M&L for erection, installation , commissioning & testing of high galvanised high mast light of height 12.5 Mtr suitable for 06 lantern symmetrically fitted along with their control gear and having two point suspension system suitable for 44 m/sec wind speed bearing capacity along with head frame, luminiaries carriage suitable for 06-08 luminiaries in symmetrical arrangement and other accesories manufactured in factory with raising & lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool torque motor, manual handle, junction box, lightening finial, Wiring material from Junction Box to individual luminiare & MCB in base compartment , with supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and connection of incoming cable with 01 No outdoor stand mounted feeder pillar and raise lower push button, Incoming cable 16 sq. mm and out cable 16 & 2.5sq.mm terminals including one number aviation obstruction light (along with reqd wiring) & lightening arrester spike (along with 6 sq mm copper cable connect to earthing) with following accessoroes and components complete all as specified and directed. Contd.....
Note : 1. Contractor has to submit complete Manufacturer's Tech Drawing of High Mast Poles and lighting along with its technical specfications and Drawing of RCC foundation d and get it approved by Engr-in-Charge and GE before executing the work as per approved drawing and OEM recommendations. 2. Rates of RCC foundation including exacavation & earth work included in the quoted rates. 3. Rates of other left out accesories required during successful operation of HIGH mast light will be paid by the contractor without any claim to the department. Contd.....
HIGH MAST SYSTEM MAKE : Approved Make Height of mast : 12.5 Meter No. of Section : Two Plate Thickness : Top - 3 MM, Bottom- 3 MM Material Construction : S355 Grade as per BS-EN10 025 Base dia and top diameter (A/F): Top : 100 mm Bottom : 360 mm Cross section of Mast : 20 sides Polygon or as per OEM Standard for Galvanisation : A per BS EN ISO 1461 Size of Opening door at base : 1200 x 250 mm Diameter of base plate : 520 mm Thickness of base plate : 25 mm Lighting protection finial : GI single spike of length 1200mm Max. wind speed : 44m/s as per IS 875 (Part III) Number of foundation bolts : 12 No or 06 Nos as per OEM PCD of foundation bolts : 445mm Type / diameter / length of foundation bolts : TS 600/24mm dia/750 mm long Contd.....
: FOUNDATION DETAILS as per follows or as per OEM and the drawing of foundation of High Mast to be approved by the GE before execution of work 1. Excavation dimensions 2800 x 2800 x 1500mm size 2. Lean Concrete 100 mm thick PCC ( 1:4:8) D2 (using 40mm graded Aggregate) 3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers 4. RCC (1: 1.5 : 3) 2600 X 2600 X300MM as in footing 5. RCC (1 : 1.5 : 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) 6. 8 Nos 16mm dia TMT Bars 4 at corners 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars 7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. 8. 10mm dia TMT bars @ 100mm C/C as Stirrups Contd.....
9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. 10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanised nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFL removal of surplus earth, foundation concrete,external finishes and all other unforeseen items all as directed by Engr - in- Charge. LUMINAIRES CARRIAGE Material of construction : 50 NB ERW Class B-M.S Pipe Diameter of carriage ring (mm) : 535 mm (ID) Construction : 06 Arm, Welded, 2 Sections Load carrying capacity : 08 Luminaire Contd.....
TRAILING CABLE Conductor : Copper, 5 core, 2.5 Sqmm Insulation : EPR insulated PCP scheathed No.of circuits per mast : One WINCH / POWER TOOL Type /SWL of winch : Single gear, Double drum, SWL 500 Kg Method of Operation : Integral Motor Motor Capacity : 1.5 HP ( Including suitable starter) No of Speeds : 6 Pole, Single speed Torque Limitor : With Mechanical Tripping Facility STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 Construction Number of Ropes : Two Continuous Diameter (mm) : SS304 grade, 6 mm Breaking load Capacity : 2350 Kg x 2
Supply ,fixing ,commisioning and testing of LT feeder Panel outdoor type of suitable size made cubical type weather and vermin proof fixed and including PCC arrangement PCC 1:2:4 type B-2 using 40 mm graded stone aggregrate as in foundation of required/suitable size and as directed at site with angle iron frame of size40x40x5 mm 3 phase 4 wire 415 volts 50 Hz fabricated with MS sheet including two coats of synthetic enemeled paint over a coat of red oxide primer and keeping adequate working space inside the box and double door handle includng locking arrangement as directed before manufacturing the panel . The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same having following electric controls: Incoming: (i) MCCB 63 Amps TPN 415 volts 50 Hz 16 KAconnected with required bus bar connections - 01 Nos (ii) Digital Voltmeter -01 , Digital Ampmeter-01, Indicating Lamp RYB- 01 set Contd.....
Outgoing: (i) MCB 40 Amps TPN 415 volts 50 Hz 16 KA - 02 Nos (ii) Three Phase Timer switch astronomical type with suitable contactors & Relay protection switches- 01 (iii) Auto manual switch for timer operation mode (iv) Push button switch assembly for lowering and raising with torque motor for light fittings structure.
Supply and fixing LED flood light 150 Watt 230 Vols AC outdoor type with thermal management in multiple optics and equipped with IP 66 Protection with inbuilt Surge protection Device (SPD) for protection of surge upto 10 KV, heat resistant toughened glass with excellent thermal management including PVC cable connector, LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95 complete all as specified.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium conductor , 1100 volts grade of size 4 core 16 Sqmm complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 2 core 10 Sqmm complete all as specified and directed.
Supply, fixing & connection of cable twin core PVC insulated and unsheathed solid aluminium conductor of size 2.50 Sqmm inside the steel tubular Poles for connection of street lights to Pole loop in loop out junction box with proper lugs/connectors complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to Galvanized Iron (GI) strip 32x6 mm size protected with GI pipe 40 mm medium grade with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to earthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and directed by Engineer-in-charge.
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in any type soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Cutting of floor/wall/road/footpath for laying of LT U/G cable inside GI Pipe of any size/description and making good the same as per existing specification laying the new cable and all as specified & directed.
S & F GI pipe light grade 40 mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
Supply and fixing powder coated pressure die cast aluminium compact LED street light fitting, heat resistance toughened glass with lens,driver and surge protector suitable for 45 Watt IP 66 Protection with inbuilt Surge protection Device (SPD) for protection of surge upto 10 KV, heat resistant toughened glass with excellent thermal management including PVC cable connector, LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95 complete all as specified and as directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthetic enamel paint in red and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles and making holes for street lights connection wire/conductor cable. as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
Supply and fixing of street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.5 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps complete all as specified and directed.
Supply and fixing of loop-in loop-out box of size 30cmx25cmx20cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25 x 2mm - 4 No fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.
Supply,installing,commissioning and testing in replacement of LT Panel/ LT feeder pillar outdoor type front and rear openable of dimension as per specified by manufacturer ,CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement with angle iron frame of size 50mm x 50mm x 6mm, pedastial type and provided with four Nos of angle iron supports duly embedded in foundation by PCC 1:2:4 type B-1 using 20 mm graded stone aggregate and as directed at site fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box and double door handle including front mounted cabinet, rod operated locking arrangement wih keys & countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors as directed before manufacturing the panel including Bus bar of following capacity and type with stainless steel nut bolts washers and spares holes with nut bolts on each bus bar and duly covered with shrinkable PVC sleeves as per colour coding ie Red, Yellow, Blue and Black & mounted on DMC / epoxy insulator and making connection of cables with appropriate size of lugs and cable glands and also two No danger Notice plate fixed on panel & The panel shall be prewired with suitable size PVC insulated copper conductor cable not less than 1.5 sqmm, multistranded complete all as specified and directed. Contd.....
Note (a) The contractor shall submit the drawing of panels for approval before manufacturing the panels. (b) All the MCCBs fixed in vertical ON/OFF positions (c) All existing cable of any size will be connected with suitable size of cable lugs ,steel glands, nut bolt etc as required at site and as directed (d) Cost of cable lugs, nut bolts, gland etc shall be deemed to be included in the above quoted rates. (e) Panels should be provided with lock of 2 key sets. Contd.....
M & L in replacement for fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 300 mm duly provided with aluminimum busbar of size 50 mm x 6mm fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser with one No incommer MCCB 4 pole 200 Amp 36 KA complete with grouting of bus bar chamber in ground by using angle iron frame of size 40mmX40mmX5mm with legs size of bus bar panel of 450mm , PCC (1:2:4) type C-1 with 20mm graded stone aggregate. all as sepcified and directed incl making connection /thimbles etc complete all as specified and directed.
S&F heat shrink LT end joints for Cable size 70 qmm to 150 sqmm complete all as specified and directed.
S&F heat shrink LT end joints for Cable size 185 sqmm to 240 sqmm complete all as specified and directed.
S&F heat shrink LT end joints for Cable size 300 sqmm to 400 sqmm complete all as specified and directed.
Supply, installation, commissioning and resting of centrifugal pump with motor capacity 120 HP/ 90 Kw , 1480 RPM at 120m head, discharge of 165 .0 M3/hr with Bronze- casing Bronze impeller 40 C8 pump shaft with maechanical seal mounted on a common base plate and coupled directly through CI coupling with suitable capacity of 3 phase electric motor for operation on 1480 RPM , 415 volts 50Hz class B Insulation with all accessories complete all as specified and directed with following ;- (a) Pressure gauge with brass cock -01 nos (b) PCC foundation to install new pump sets should be as per manufacturers design including grouting suitable size of nuts bolts and anti vibration pads for vibration free running of pumps & rate are deemed to be included in this item as directed at site. (c) Air release pipe and primming pipe with gate valve 20mm (d) Any item like cutting welding etc required at site for making connection deemed to be included in this item as directed at site.
Supply and Fixing of PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core of 120 Sqmm size from LT panel to starter and starter to motor including crimping of copper lugs -06 nos, complete all as directed.
Supply and Fixing of CI Sluice valve both end flanged class PN-1.6 of size 150 mm heavy duty ISI marked conforming to IS 14846 9latest revision) with cast iron wheel with brass spindles with rubber gasket nuts, bolts etc complete all as specified and as directed.
Supply and Fixing of cast iron non return valve swing type 150 PSI or PN 1.6, ISI marked, on rising main, both end flanged complete with jointing materials such as rubber gasket, nut & bolts with suitable washer complete of 150 mm dia of pipes including alteration work in pipe line complete all as specified and as directed.
BLANK
Note : Tenderers may note that amount of credit Rs 10,800.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
KP ELECTRICAL AND AUTOMATION (BID ID -3082397)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .