Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Quoted Bid.(L1) | |
| 2 | L2₹16.7 L+₹2.7 L (19.6%)Rejected-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L2 | Rejected-AOC Higher Quoted Bid. | |
| 3 | L3₹17.5 L+₹3.5 L (25.4%)Rejected-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-AOC Higher Quoted Bid. | |
| 4 | L4₹21 L+₹7.0 L (50.5%)Rejected-AOC CANADA BUILDING 224 DR D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L4 | Rejected-AOC Higher Quoted Bid. |
Tender Value
₹20.2 L
EMD Value
₹40,387
Closing Date
17 Dec 2019, 6:00 pmClosed
AGM(E-E)
AGM(E-E), Airports Authority of India, Vadodara Airport, Vadodara -390022
Replacement of H-Indicator and SITC of spare CCRs for GLF System at Vadodara Airport.
2019_AAI_36932_1
AAI/BO/EE/NIT02/HIND/2019-20
Open Tender
Electrical Works
Item Rate
90 days
Vadodara Airport
Please refer Tender documents.
16 documents required · 16 mandatory
₹1,180
Airports Authority of India
₹40,387
12 Feb 2020
5 Dec 2019
26 Dec 2019
5 Dec 2019
17 Dec 2019
5 Dec 2019
5 Dec 2019 - 16 Dec 2019
Amount
Supply, Installation, Testing & Commissioning of Landing 'H'direction indicator complying ICAO standard consisting of three rectangular AL limbs having length of 4000 mm each supported with 50mm dia Aluminium frangible pipe of 1350mm length & flanges, suitable wattage linear LED lights with driver (minimum IP65) for each limb , each circuits to operate on 230 V, 50 Hz AC supply ,providing control unit with suitable control transformer, Relay, Contactor, copper wiring upto Junction Box etc. as required for remote operation of landing 'T' from CCR Hall as well as from control tower, connections/ interconnections, civil foundations for each legs along with MS anchor base plate, casting pedestal up to 1mtr outside all around the landing 'H' with 1:2:4 cement concrete of 100mm thick and neat finish top etc. as per tender techncal specification and tender terms and condition etc complete as required.
SITC of FAA compliance indoor type microprocessor based, air cooled constant current regulator of Thyristor controlled electronic type suitable for use on 240/415 VAC; 50/60 Hz, input AC supply with below mentioned output power with 5 steps variation of current output suitable for local and remote control operation with 24/48/60 VDC control supply complete with output current indicated on multifunction digital display, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc. with suitable angle iron foundation and nut bolting as required as per specification of following rating : 4 KW MPCCR at 6.6 Amp, supply voltage 240 VAC
SITC of FAA compliance indoor type microprocessor based, air cooled constant current regulator of Thyristor controlled electronic type suitable for use on 240/415 VAC; 50/60 Hz, input AC supply with below mentioned output power with 5 steps variation of current output suitable for local and remote control operation with 24/48/60 VDC control supply complete with output current indicated on multifunction digital display, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc. with suitable angle iron foundation and nut bolting as required as per specification of following rating : 7.5 KW MPCCR at 6.6 Amp, supply voltage 240 VAC
SITC of FAA compliance indoor type microprocessor based, air cooled constant current regulator of Thyristor controlled electronic type suitable for use on 240/415 VAC; 50/60 Hz, input AC supply with below mentioned output power with 5 steps variation of current output suitable for local and remote control operation with 24/48/60 VDC control supply complete with output current indicated on multifunction digital display, over current, over voltage, earth fault protection and earth leakage meter, positive back indication equipments relay contactor etc. with suitable angle iron foundation and nut bolting as required as per specification of following rating : 30 KW MPCCR at 20 Amp, supply voltage 415 VAC
Supply Installation Testing and commissioning of Brilliancy controller [ 2 Pole 5 Way make before break type rotary wefer brightness control switch with knob and marking anodize plate.] in remote control desk by replacing the existing MS plate with new powder coated 3mm thick MS plate of remote control desk and rearrange the existing brilliancy controllers, indicators and toggle switches etc. with necessary control connections in both side i.e. CCR Side and Remote control desk side etc. complete as per site requirement.
Techno Electricals
Manish Electricals
AMA Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .